N671US, cancelled Feb 6, 2019
Service difficulty reports · 93
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N671US' AND deregistration_id = 'N671US-2019-02-06' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N671US' AND deregistration_id = 'N671US-2019-02-06' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR DALA2014090104873Charger · inoperativeSEAT ROWS 51-66 RT SIDE, EMERGENCY LIGHTS INOPERATIVE. R & R CHARGER AND BATTERIES.SDR DALA2014062303689Fuse · inoperativeEMERGENCY ESCAPE PATH LIGHTING INOPERATIVE AT 51H-63H SEAT. REPLACED FUSE.SDR DALA14013436311Frame · crackedFRAME CRACKED AT BS 1140 ON RT SIDE UPPER LOBE TENSION TIE. FRAME REPAIRED IAW SRM 53-40-07, REPAIR 2, HFEC INSPECTED FRAME CUT EDGE AND ALL INITIAL FASTENER HOLES AT REPAIR AREA FOUND NO CRACK IAW NDTM PN 6, 51-00-00, PROCEDURE 23 AND 16, NEW SECTION OF FRASDR DALA14012286311Channel · crackedFORWARD CHANNEL AT L/E BS 1180 UPPER LOBE TENSION TIE FOUND CRACKED FASTENER HOLES. INSTALLED REPAIR ANGLES AND CHANNEL IAW SRM 53-40-30 REPAIR 2.SDR DALA14012276311Channel · crackedONE CRACKED FASTENER HOLE FOUND IN THE FWD CHANNEL AT BS 1180 ON RT SIDE UPPER LOBE TENSION TIE. CRACKED FASTENER HOLE LOCATIONS AT THE UPPER ROW, FIFTH FASTENER HOLE FROM OTBD. INSTALLED REPAIR ANGLES AND CHANNEL IAW SRM 53-40-30, REPAIR 2.SDR DALA14000396311Light · inoperativeEMERGENCY LIGHTS INOPERATIVE. FOUND LIGHT ASSY DEFECTIVE BEHIND 43 HJK. REPLACED EMERGENCY LIGHT ASSY. PERFORMED EMERGENCY LIGHT OPS CHECK OK IAW AMM 33-51.SDR DALA13046206311Battery Pack · inoperativeUNDER DECK RT DOOR BATTERY INDICATION LIGHT TEST MALFUNCTION. REPLACED MPN NW6A24-41484-501 BATTERY PACK IAW AMM 52- 23, TEST OK.SDR DALA13011146311Power Supply · inoperativeRIGHT OVERWING EMERGENCY LIGHT 3RD AND 4TH ROW FROM AFT INOPERATIVE. REPLACED POWER SUPPLY.SDR DALA12005236311Shear Web · crackedDURING INSPECTION FOUND MAIN DECK ZONE 'C' LEFT TENSION TIES SLOPING SHEAR WEB SUPPORTING GUSSET CRACKED AT BS 1120. MAINTENANCE REMOVED AND REPLACED GUSSET AS PER SRM 51-40-02.SDR DALA12004316311Skin · crackedDURING INSPECTION FOUND L2 DOOR CUTOUT FORWARD LOWER REVEAL CRACKED. MAINTENANCE REPAIRED L2 DOOR CUTOUT FORWARD LOWER REVEAL PER SRM 53-60-15.SDR DALA12004006311Shear Web · crackedDURING INSPECTION, FOUND MAIN DECK ZONE 'C' RIGHT TENSION TIES SLOPING SHEAR WEB SUPPORTING GUSSET CRACKED. MAINTENANCE REMOVED RIGHT TENSION TIES SLOPING SHEAR WEB SUPPORTING GUSSET AS PER SRM 51-40-02. FABRICATED NEW GUSSET MATERIAL USED 2024-0-0.050" AS PSDR DALA12005226311Floorbeam · corrodedDURING INSPECTION FOUND CORROSION ON MAIN DECK BS 860, RBL 45-50, FLOORBEAM. REPAIRED PER SRM 53-20-51.SDR DALA12004546311Shear Web · crackedDURING INSPECTION, FOUND ZONE C LEFT TENSION TIES SLOPING SHEAR WEB EDGE CRACKED. MAINTENANCE REMOVED AND REPLACED LEFT TENSION TIES SLOPING SHEAR WEB AS PER SRM 51-40-02.SDR DALA12003996311Shear Web · crackedDURING INSPECTION, FOUND ZONE C RIGHT TENSION TIES SLOPING SHEAR WEB EDGE CRACKED. MAINTENANCE REMOVED RIGHT TENSION TIES SLOPING SHEAR WEB AND REPLACED AS PER SRM 51-40-02.SDR DALA12001736311Battery Pack · inoperativeDURING INSPECTION FOUND UPPER DECK LEFT EMERGENCY DOOR CHECK LIGHT INOPERATIVE. REPLACED POWER SUPPLY, BATTERY AND SWAPED ANNUNCIATOR.SDR DALA12001706311Light · inoperativeDURING INSPECTION, FOUND EMERGENCY LIGHT OUT AT DOOR 1R PURSERS DESK. MAINTENANCE REPAIRED LIGHT ASSEMBLY, OPS CHECKED OK.SDR DALA12001696311Light · inoperativeDURING INSPECTION FOUND 3 EMERGENCY LIGHTS OUT BETWEEN ROWS 77 AND 78. MAINTENANCE REPLACED LIGHT ASSEMBLY. OPS CHECKED OK.SDR DALA1232276311Light · inoperativeDURING INSPECTION, FOUND FLOOR PATH LIGHT OUT. MAINTENANCE REPLACED EMERGENCY LIGHT POWER SUPPLY PER AMM 33-51. OPS CHECKED OK.SDR DALA1232256311Light · missingDURING INSPECTION, FOUND 66H FLOOR PATH LIGHT ASSY MISSING. MAINTENANCE INSTALLED FLOOR PROXIMITY PATH LIGHTING PER AMM 25-27. OPS TESTED OK.SDR DALA1227686311Power Supply · inoperativeDURING INSPECTION FOUND RIGHT OVERWING EMERGENCY LIGHT AT 3RD FROM FORWARD WON'T ILLUMINATE. MAINTENANCE REPLACED POWER SUPPLY PER B747-400 AMM 33-51. OPERATIONAL CHECK OK.SDR DALA1227676311Power Supply · inoperativeDURING INSPECTION FOUND LEFT OVERWING EMERGENCY LIGHT AT 2ND FROM FORWARD WON'T ILLUMINATE. MAINTENANCE REPLACED POWER SUPPLY PER B747-400 AMM 33-51. OPERATIONAL CHECK OK.SDR DALA1224296311Fuse · blownDURING SVC CHECK FOUND U/D FLOOR PATH LIGHT INOP IN FWD AISLE. MAINTENANCE REPLACED R/R FUSE FOR POWER SUPPLY (M5932) AND OPS CKD GOOD PER MM 747400-A-33-51-04.SDR DALA1209766311Power Supply · inoperativeDURING A LINE CHECK, MAINTENANCE FOUND THE LEFT 2ND EXTERIOR EMERGENCY LIGHT INOPERATIVE. MAINTENANCE REPLACED THE POWER SUPPLY. OPS CHECKED GOOD.SDR DALA1208976311Unknown · odorFLT 630, DURING CRUISE AT FL330, A BURNING ELECTRICAL ODOR NOTED THROUGHOUT AIRCRAFT, WITH STRONGEST INDICATION NEAR DOOR 5R. TURNED OFF LEFT & RIGHT UTILITY BUSSES, AND ODOR DISSIPATED. STATUS MESSAGE LAVATORY AND GALLEY FANS DISPLAYED. CONTINUED TO DESTSDR DALA1204326311Wire · looseDURING A MAINTENANCE VISIT, THE EMERGENCY FLOOR LIGHT AT SEATS 1JK TO 2JK WERE FOUND TO BE INOPERATIVE. MAINTENANCE SECURED THE WIRE. SYSTEM OPERATION WAS NORMAL AFTER THE WIRE WAS SECURED.SDR DALA1165376311Battery · dischargedDURING A MAINTENANCE VISIT, THE EMERGENCY FLOOR PROXIMITY LIGHTS AT ROWS 35 THROUGH 65 ON THE RIGHT WERE FOUND TO BE INOPERATIVE. MAINTENANCE REPLACED THE BATTERY IN THE POWER SUPPLY. SYSTEM OPERATION WAS NORMAL AFTER THE BATTERY WAS REPLACED.SDR DALA1165316311Light · missingDURING A MAINTENANCE VISIT, THE EMERGENCY FLOOR PROXIMITY LIGHT AT DOOR 2R WAS FOUND MISSING. MAINTENANCE REPLACED THE LIGHT ASSEMBLY. SYSTEM OPERATION WAS NORMAL AFTER THE LIGHT ASSEMBLY WAS REPLACED. (2011-00735)SDR DALA1165246311Connector · looseDURING A MAINTENANCE VISIT, THE EMERGENCY FLOOR PROXIMITY LIGHT AT ROW 72 WAS FOUND TO BE INOPERATIVE. MAINTENANCE SECURED THE CONNECTION ON THE LIGHT ASSEMBLY. SYSTEM OPERATION WAS NORMAL AFTER THE LIGHT ASSEMBLY CONNECTION WAS SECURED.SDR DALA1159566311Wire · damagedDURING A MAINTENANCE VISIT, THE EMERGENCY FLOOR PROXIMITY LIGHT AT G2A ON THE LEFT SIDE WAS FOUND TO BE INOPERATIVE. MAINTENANCE REPAIRED AND SECURED THE WIRE. SYSTEM OPERATION WAS NORMAL AFTER THE WIRE WAS REPAIRED.SDR DALA1159116311Pin · brokenDURING A MAINTENANCE VISIT, MAINTENANCE FOUND THE EMERGENCY EXIT LIGHT AT DOOR 3R INOPERATIVE. MAINTENANCE FOUND THE NR 8 PIN BROKEN AND REPLACED IT. SYSTEM OPERATION WAS NORMAL AFTER THE PIN WAS REPLACED.SDR DALA1157736311Connector · looseDURING A MAINTENANCE VISIT, THE EMERGENCY ESCAPE FLOOR LIGHT AT LAVATORY DOOT 1L WAS FOUND TO BE INOPERATIVE. MAINTENANCE FOUND THE LIGHT CONNECTOR LOOSE OUTSIDE OF LAVATORY DOOR 1L2 AND RECONNECTED IT. SYSTEM OPERATION WAS NORMAL AFTER THE CONNECTOR WAS RECSDR DALA1157056311Light · inoperativeDURING A MAINTENANCE VISIT, THE EMERGENCY SLIDE LIGHT AT DOOR 1R WAS FOUND TO BE INOPERATIVE. MAINTENANCE REPLACED THE DOOR SLIDE LIGHT. SYSTEM OPERATION WAS NORMAL AFTER THE LIGHT WAS REPLACED. 586578 TPE 2011-00634SDR DALA1150646311Power Supply · inoperativeDURING A MAINTENANCE VISIT, THE OVERWING EMERGENCY LIGHTS AT LEFT FORWARD (2EA) AND RIGHT AFT (2EA) WERE FOUND TO BE INOPERATIVE. MAINTENANCE REPLACED THE POWER SUPPLY AT 3R. SYSTEM OPERATION WAS NORMAL AFTER THE POWER SUPPLY WAS REPLACED.SDR DALA1149226311Wire · looseDURING A MAINTENANCE VISIT, THE EMERGENCY ESCAPE PATH LIGHT WIRES LOOSE AT SEAT 1J. MAINTENANCE ADJUSTED THE PITCH OF THE EMERGENCY PATH LIGHTS AND REINSTALLED TRACK COVERS OVER THE WIRING AT SEAT 1J. SYSTEM OPERATION WAS NORMAL. AIRCRAFT OK FOR SERVICE.SDR DALA1147896311Light · inoperativeDURING A LINE CHECK, MAINTENANCE FOUND THE EMERGENCY PATH LIGHT AT SEAT 9J INOPERATIVE. MAINTENANCE REPLACED THE LIGHT ASSEMBLY AND LENS COVER. OPERATIONAL CHECK WAS GOOD.SDR DALA1145686311Light · inoperativeDURING A MAINTENANCE VISIT, THE EMERGENCY FLOOR LIGHT AT SEAT 9K WAS FOUND TO BE INOPERATIVE. MAINTENANCE REPLACED THE EMERGENCY LIGHT ASSEMBLY. SYSTEM OPERATION WAS NORMAL AFTER THE LIGHT ASSEMBLY WAS REPLACED.SDR DALA1137236311Wire · disconnectedDURING A LINE CHECK, MAINTENANCE FOUND THE EMERGENCY PATH LIGHTS AT SEATS 9J - 10J INOPERATIVE. MAINTENANCE RECONNECTED A WIRE. OPERATIONAL CHECK WAS GOOD.SDR DALA1135116311Lamp · inoperativeDURING A MAINTENANCE VISIT THE EMERGENCY FLOOR LIGHTS FROM SEAT 35C TO 40C WERE FOUND TO BE INOPERATIVE. MAINTENANCE RELMAPED AND SECURED THE CONNECTOR. SYSTEM OPERATION WAS NORMAL AFTER THE CONNECTOR WAS SECURED.SDR DALA1122896311Wire · disconnectedDURING A MAINTENANCE VISIT, THE EMERGENCY ESCAPE PATH FLOOR TRACK LIGHT FROM SEAT 22H TO DOOR 2R WERE FOUND TO BE INOPERATIVE. MAINTENANCE FOUND THE WIRE DISCONNECTED AT SEAT 22H AND RECONNECTED THE WIRE. SYSTEM OPERATION WAS NORMAL AFTER THE WIRE WAS RECONNSDR DALA1107606311Wire · damagedDURING A MX LAYOVER CHECK, THE EMERGENCY PATH LIGHT AT SEAT 9JK WAS FOUND INOPERATIVE. MX REPLACED LIGHT ASSY AND REPAIRED WIRE. SYS OPS WERE NORMAL AFTER LIGHT ASSY WAS REPLACED.SDR DALA1105866311Charger · inoperativeON CHECK FOUND UPPER DECK LIGHT DOOR BATTERY OK. LIGHT WON'T ILLUMINATE WHEN PRESSED/TESTED. TROUBLESHOOTING FOUND BATTERY CHARGER AT FAULT. REPLACED BATTERY CHARGER IAW AMDS 400-A-52-23-14-401-926A-A. SECURED & OPS TEST CHECKED OK. ACFT OK FOR SERVICESDR DALA1125626311Wire · looseDURING A LINE MX CHECK, THE EMERGENCY PATH FLOOR LIGHT FROM DOOR 7R TO SEAT 9J WAS FOUND TO BE INOPERATIVE. MX FOUND A LOOSE WIRE AT SEAT 9J AND RECONNECTED IT. SYS OPS WAS NORMAL AFTER THE WIRE WAS RECONNECTED.SDR DALA1103596311Wire · disconnectedDURING A LINE CHECK, MX FOUND 2 EMERGENCY PATH LIGHTS AFT OF DOOR 1R INOPERATIVE. MX RECONNECTED THE WIRING. OPS CHECK WAS GOOD.SDR DALA1051666311Light · missingDURING A LINE CHECK, MX FOUND THE EMERGENCY PATH LIGHTS AT 10JK AND LAV 2R MISSING. MX REPLACED THE LIGHT ASSEMBLIES. OPS CHECK WAS GOOD.SDR DALA1051116311Wire · damagedDURING A LINE CHECK, MX FOUND THE EMERGENCY PATH LIGHTS BETWEEN DOOR L1 & L2, AND BETWEEN DOOR 1R AND ROW 9 INOPERATIVE (ZONE B). MX REPAIRED THE CONNECTIONS AND THE LIGHT ASSEMBLIES. OPS CHECK WAS GOOD.SDR DALA1034236311Wire · damagedDURING A LAYOVER CHECK, MX FOUND THE EMERGENCY PATH LIGHTS AT SEAT 10AB TO 12AB INOPERATIVE. MX REPAIRED THE WIRING. OPS CHECK WAS GOOD.SDR DALA1031266311Wire · openDURING A LINE CHECK, MAINTENANCE FOUND SEAT 9JK AREA EMERGENCY PATH LIGHTS INOPERATIVE. MAINTENANCE REPAIRED AN OPEN WIRE. OPERATIONAL CHECK WAS GOOD. (2010-00848)SDR DALA1028916311Wire · damagedDURING LAYOVER CHECK, MAINTENANCE FOUND EMERGENCY PATH LIGHTS AT SEATS 9 - 12B INOPERATIVE. MAINTENANCE REPAIRED THE WIRING AT SEAT 9B. OPERATIONAL CHECK WAS GOOD.SDR DALA1027920663Wire · damagedDURING LINE CHECK, MAINTENANCE FOUND THE EMERGENCY PATH LIGHTS BETWEEN DOOR 1L & 2L INOPERATIVE. MAINTENANCE REPAIRED THE WIRING. OPERATIONAL CHECK WAS GOOD.SDR DALA1027066311Light · inoperativeDURING A LINE CHECK, MAINTENANCE FOUND AN EMERGENCY PATH LIGHT NEAR DOOR 1L LAV INOPERATIVE. MAINTENANCE RECONNECTED THE LIGHT. OPERATIONAL CHECK WAS GOOD (2010-00805).