N672US, cancelled Feb 6, 2019
Service difficulty reports · 44
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N672US' AND deregistration_id = 'N672US-2019-02-06' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N672US' AND deregistration_id = 'N672US-2019-02-06' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR DALA2014080304293Fuse · failedEMERGENCY LIGHT RT OVERWING IS OUT. REPLACED POWER SUPPLY (M7920) FUSE.SDR DALA2014073104271Light · inoperativeEMERGENCY LIGHT NEAR L4 DOOR F/A JUMP SEAT WOULD NOT TURN ON WHEN EMERGENCY LIGHT CHECKED. REPLACED LIGHT ASSY.SDR DALA14016356312Channel · crackedA CRACK WAS FOUND IN THE FWD CHANNEL ON BS 1120 ON THE RT SIDE OF AIRPLANE. CHANNEL REPAIRED IAW SRM 53-40-30, REPAIR 2. HFEC INSPECTED THE CHANNEL CUT OUT EDGE AND FASTENER HOLES, FOUND NO CRACK IAW NDTM PART 6, 51-00-00 FIG 16 AND FIG 23, REPAIR ANGLES SDR DALA13052566312Power Supply · inoperativeRT EXTERIOR EMERGENCY LIGHT AFT OF WING INOPERATIVE. TROUBLESHOT IAW WDM 33-51-42 AND REPLACED POWER SUPPLY AND BATTERY IAW MM 33-51-04, OPS CHECKED GOOD. OK FOR SERVICE.SDR DALA13037466312Fuse · inoperativeDURING INSPECTION, FOUND EMERGENCY LIGHTS AT LT OVERWING FWD INOPERATIVE. REPLACED FUSE IN POWER SUPPLY.SDR DALA13037456312Power Supply · inoperativeDURING INSPECTION, EMERGENCY LIGHTS AT RT OVERWING FORWARD AND AFT WERE INOPERATIVE. REPLACED POWER SUPPLY FOR RT FWD AND RELAMPED RT AFT LIGHTS.SDR DALA12005806312Flap Track · damagedDURING INSPECTION, FOUND LEFT OUTBOARD TRAILING EDGE FLAP NR 2 FLAP TRACK OUTBOARD FORWARD UPPER FLANGE SURFACE CORROSION. MAINTENANCE REMOVED AND REPLACED NR 2 FLAP TRACK AS PER B747-400 AMM 27-51-27.SDR DALA12002336312Lamp · inoperativeDURING INSPECTION FOUND EMERGENCY LIGHTS OUT AT 74, 78, 79. MAINTENANCE RELAMPED, OPS CHECKED OK.SDR DALA12001756312Power Supply · inoperativeDURING INSPECTION FOUND EXTERIOR EMERGENCY LIGHT INOPERATIVE AT RIGHT FORWARD OVERWING. MAINTENANCE REPLACED POWER SUPPLY BPS7-3 AND DEFECTIVE FUSE ON M7919 POWER SUPPLY. PERFORMED EMERGENCY LIGHTS CHECK, OK AS PER B747-400 AMM NR 33-51.SDR DALA12000436312Connector · dirtyDURING INSPECTION, FOUND SEVERAL FLOOR PROXIMITY EMERGENCY LIGHTS INOPERATIVE. MAINTENANCE CLEANED CONNECTIONS AND REPLACED LAMPS.SDR DALA1233376312Fuse · inoperativeDURING INSPECTION FOUND RIGHT OVERWING EMERGENCY LIGHT AT MOST FORWARD WON'T TURN ON. MAINTENANCE REPLACED FUSE ON M7919 POWER SUPPLY AND PERFORMED OPERATIONAL CHECKED OK AS PER AMM 33-51.SDR DALA1226226312Connector · looseDURING INSPECTION FOUND EMERGENCY LIGHTS FROM ROW 51HJK THROUGH 63HJK ARE INOPERATIVE. MAINTENANCE SECURED LOOSE CONNECTION AND TEST OK PER B747 AMM 33-51-12/201.SDR DALA1226206312Connector · looseDURING INSPECTION, FOUND EMERGENCY LIGHTS FROM DOOR 2LT TO ROW 22ABC ARE INOPERATIVE. MAINTENANCE SECURED LOOSE CONNECTION AND TEST OK PER B747 AMM 33-51-12/201.SDR DALA1214956312Connector · looseDURING A MAINTENANCE VISIT, THE EMERGENCY ESCAPE PATH LIGHT BY LAVATORY DOOR 4L WAS FOUND TO BE INOPERATIVE. MAINTENANCE FOUND THE WIRE CONNECTOR LOOSE BY SEAT 43C AND RECONNECTED IT. SYSTEM OPERATION WAS NORMAL AFTER THE CONNECTOR WAS RECONNECTED.SDR DALA1213646312Fuse · openDURING A MAINTENANCE VISIT, THE OVERWING EMERGENCY LIGHT ON THE RIGHT SIDE WAS FOUND TO BE INOPERATIVE. MAINTENANCE FOUND THE POWER SUPPLY FUSE OPEN AND REPLACED IT. SYSTEM OPERATION WAS NORMAL AFTER THE FUSE WAS REPLACED.SDR DALA1204086312Power Supply · inoperativeDURING A MAINTENANCE VISIT, THE FORWARD OVERWING EMERGENCY LIGHT ON THE LEFT SIDE WAS FOUND TO BE INOPERATIVE. MAINTENANCE FOUND THE POWER SUPPLY FUSE AT 3L DOOR DEFECTIVE. MAINTENANCE REPLACED THE POWER SUPPLY. SYSTEM OPERATION WAS NORMAL AFTER THE POWER SSDR DALA1160296312Power Supply · inoperativeDURING A MAINTENANCE VISIT, THE FORWARD EXTERIOR EMERGENCY LIGHT ON THE LEFT SIDE WAS FOUND TO BE INOPERATIVE. MAINTENANCE REPLACED THE POWER SUPPLY. SYSTEM OPERATION WAS NORMAL AFTER THE POWER SUPPLY WAS REPLACED.SDR DALA1154426312Light · inoperativeDURING A MAINTENANCE VISIT, THE EMERGENCY SLIDE LIGHT AT DOOR 4R WAS FOUND TO BE INOPERATIVE. MAINTENANCE REPLACED THE DOOR SLIDE LIGHT PER B747 AMM 33-51-06. SYSTEM OPERATION WAS NORMAL AFTER THE SLIDE LIGHT WAS REPLACED.SDR DALA1104406312Power Supply · inoperativeDURING A LINE CHECK, MX FOUND THE RT 3RD & 4TH OVERWING EMERGENCY LIGHTS INOPERATIVE. MX REPLACED THE POWER SUPPLY M7920 AND BATTERY. OPS CHECK WAS GOOD.SDR DALA1104396312Battery Pack · inoperativeDURING A LINE CHECK, MX FOUND THE RT FWD EXTERIOR EMERGENCY LIGHT INOPERATIVE. MX REPLACED THE POWER SUPPLY M7919 AND BATTERY. OPS CHECK WAS GOOD.SDR DALA1030036312Fuse · blownDURING A LINE CHECK, MAINTENANCE FOUND THE RT MOST FWD OVERWING EMERGENCY LIGHT INOPERATIVE. MAINTENANCE REPLACED A POWER SUPPLY FUSE. OPERATIONAL CHECK WAS GOOD. (2010-00830)SDR DALA1022046312Indicator · odorDURING FLIGHT, THE CAPT'S RADAR DISPLAY EMITTED AN ELECTRICAL SMOKE ODOR AND BECAME ERRATIC. RADAR DISPLAY WAS SHUTOFF AND ODOR DISSIPATED. MX CONFIRMED THE WX RADAR INDICATOR AS THE SOURCE OF THE ODOR AND REPLACED IT. OPS TEST WAS GOOD.SDR DALA1020876312Connector · looseDURING LINE CHECK, MX FOUND THE B ZONE LT EMERGENCY PATH LIGHTS INOPERATIVE. MX SECURED A LOOSE CONNECTOR. OPS CHECK WAS GOOD.SDR DALA1018326312Floor Support · corrodedDURING M-CHECK FOUND CORROSION ON UPPER DECK FLOOR SUPPORT AT BS 980 RBL 20. REPAIRED IAW SRM 53-00-52.SDR DALA1015136312Connector · damagedDURING LINE CHECK, MAINTENANCE FOUND EMERGENCY PATH LIGHTS AT ROW 51HJK THROUGH 65HJK INOPERATIVE. MAINTENANCE REPAIRED CONNECTION AT THE LIGHT ASSEMBLY. OPERATIONAL CHECK WAS GOOD.SDR DALA101030Wire · disconnectedDURING LAYOVER CHECK, MX FOUND EMERGENCY PATH LIGHTS ROW 51-66 RT SIDE INOPERATIVE. MX RECONNECTED THE LIGHT WIRING AT ROW 66. OPS CHECK WAS GOOD.SDR DALA1010146312Light · inoperativeDURING LAYOVER CHECK, MX FOUND EMERGENCY PATH LIGHTS AT DOOR 4L F/A AREA INOPERATIVE. MX REPLACED THE PATH LIGHT ASSY. OPS CHECK WAS GOOD.SDR DALA102736312Light · inoperativeDURING LAYOVER CHECK, MX FOUND THE EMERGENCY SLIDE LIGHT ON PAX DOOR 2L INOPERATIVE. MX REPLACED THE EMERGENCY LIGHT ASSY. OPS CHECK WAS GOOD.SDR DALA100036312Battery Pack · inoperativeDURING LINE CHECK, RT UPPER DECK DOOR BATTERY TEST FAILED. REPLACED BATTERY PACK IAW AMM 52-23-14. OPS CHECKS GOOD.SDR NWAA093266312Power Supply · defectiveDURING AN OVERNIGHT LINE CHECK THE EMERGENCY ESCAPE PATH LIGHTS AT ROWS 77 THROUGH 79 IN THE UPPER DECK WERE FOUND TO BE INOPERATIVE. MAINTENANCE FOUND POWER SUPPLY M5933 TO BE DEFECTIVE AND REPLACED IT. SYSTEM OPERATION WAS NORMAL AFTER THE POWER SUPPLY REPSDR NWAA09836312Connector · damagedMX FOUND THE EMERGENCY LIGHTS FOR THE LT OVERWING EXIT INOPERATIVE DURING AN OVERNIGHT LINE CHECK. MX FOUND THE CONNECTOR FOR THE ASSOC PWR SUPPLY TO BE DAMAGED AND REPAIRED THE CONNECTOR PLUG. SYS OPERATION WAS NORMAL AFTER THE CONNECTOR PLUG WAS REPAIRED. SDR NWAA09746302Power Supply · inoperativeDURING OVERNIGHT CHECK, FOUND LT SIDE OVERWING EMERGENCY LIGHTS INOPERATIVE. MX REMOVED AND REPLACED POWER SUPPLY. OPS CHECKED GOOD, AND ACFT WAS RETURNED TO SERVICE. (K)SDR NWAA080246312Web · damagedDURING "L" CHECK AND ACCOMPLISHMENT OF CREW REST MODIFICATION FOUND FLOOR WEB AT BS 2300 RBL 60-RBL 80 WITH SHORT EDGE MARGIN. REPAIRED PER EA 63-211481.SDR NWAA072636312Battery Pack · inoperativeDURING OVERNIGHT LINE CHECK, CEILING EMERGENCY LIGHT IN AFT CREW BUNK WAS INOP. MAINTENANCE REMOVED AND REPLACCED POWER PACK. OPERATIONAL CHECKED GOOD AND AIRCRAFT RETURNED TO SERVICE.SDR 0700026312Line · leakingDURING CRUISE, HYDRAULIC QUANTITY WENT TO ZERO. FOLLOWED COM PROCEDURE FOR LOSS OF HYDRAULIC SYSTEM. FLIGHT CONTINUED ON TO DTW. YELLOW EMERGENCY WAS DECLARED UPON ARRIVAL IN DTW. AIRCRAFT LANDING WAS UNEVENTFUL. MAINTENANCE REMOVED AND REPLACED RETURN TUSDR 0700016312Light · inoperativeDURING OVERNIGHT CHECK, CABIN EMERGENCY FLOOR LIGHTS INOP LT SIDE ROWS 51-66. MAINTENANCE REMOVED AND REPLACED EMERGENCY LIGHTS. OPERATIONAL CHECKED GOOD, AIRCRAFT RETURNED TO SERVICE.SDR 0402086312Pseu · failedDURING CLIMB, RECEIVED A GEAR DISAGREE AND GEAR DOOR EICAS MESSAGE ACCOMPANIED WITH VIBRATION AND NOISE. AIRCRAFT RETURNED TO DTW AND DUMPED 200,000 LBS OF FUEL AND LANDED WITHOUT INCIDENT. REPLACED THE PSEU. OPERATIONAL CHECK GOOD.SDR 0401426312Oven · overheatedDURING FLIGHT, SMOKE EMITTED FROM THE 2-7 OVEN AS IT OPERATED HOTTER THAN THE MEDIUM SETTING CAUSING THE SMOKE ALARM TO ACTIVATE. THE OVEN WAS TURNED OFF AND THE CIRCUIT BREAKERS PULLED AND THE SMOKE DISSIPATED SILENCING THE SMOKE ALARM. AIRCRAFT CONTINUED TO SDR 0301126312Wire · brokenDURING LINE CHECK FOUND ZONE B-FLOOR PATH EMERGENCY LIGHTS INOPERATIVE. REPAIRED BROKEN WIRE. OPERATIONAL CHECK GOOD.SDR 0300976312Oven · smokeDURING FLIGHT SMOKE EMITTED FROM THE 3-28 OVEN IN THE NR 4 GALLEY. AIRCRAFT CONTINUED TO DESTINATION AND LANDED WITHOUT INCIDENT. REPLACED THE OVEN AND CONTROLLER. OPERATIONAL CHECK GOOD.SDR 0300676312Controller · inoperativeDURING FLIGHT SMOKE EMITTED FROM THE NR1 OVEN IN THE UPPER DECK. PULLED GALLEY CIRCUIT BREAKER, AIRCRAFT CONTINUED TO DESTINATION AND LANDED WITHOUT INCIDENT. REPLACED THE OVEN CONTROLLER, OPERATIONAL CHECK GOOD.SDR 0300466312Pseu · failedDURING CLIMB RECEIVED A NOSE "GEAR DISAGREE" AND "GEAR DOOR" EICAS MESSAGE ACCOMPANIED WITH AIRFRAME VIBRATION DURING LANDING GEAR RETRACTION. AIRCRAFT RETURNED TO DTW AND LANDED WITHOUT INCIDENT. REPLACED THE PSEU AND BOTH NOSE WHEEL ASSEMBLIES. OPERATIONAL CSDR 0003416612Slide · failedDURING SLIDE SHOP TEST AT OPERATING PRESSURE, A MULTIPLE SEAM FAILURE OF THE LOWER AIR HOLDING SILL TUBE OCCURRED AT THE GIRT END. SLIDE WILL BE OVERHAULED AND RECEIVE A NEW INFLATABLE.SDR 0003346612Power Supply · inoperativeDURING OVERNIGHT LINE CHECK, FOUND ''D'' ZONE FLOOR MOUNTED EMERGENCY LIGHTS INOPERATIVE. MAINTENANCE REPLACED THE POWER SUPPLY. OPERATIONAL CHECK OK.
Back to N672US, cancelled Feb 6, 2019