N676NK, cancelled Sep 23, 2026
Service difficulty reports · 36
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N676NK' AND deregistration_id = 'N676NK-2026-09-23' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N676NK' AND deregistration_id = 'N676NK-2026-09-23' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR GTIA2025120439194Fan · failedAMBER FAN INDICATION ON COND PAGE SMELLED SMOKE IN FLT DECK AND CABIN.SDR GTIA2025090839069Unknown · odorFUME EVENT AFTER TAKEOFF. DESCRIPTION OF FUMES/ODOR: TEMPORARY, OTHER SMELL. APPARENT CABIN SOURCE: CABIN AIR SUPPLY VENTS. FWD CABIN, FLIGHT DECK, MID CABIN, AND AFT CABIN. NO VISIBLE SMOKE/HAZE. PERFORMED PACK BURN OUT IAW AMM 05-50-00. NO ODOR DETECTED AC SDR GTIA2025061638960O-Ring · leakingHYR Y RSVR LO LVL. LED TO TURNING OFF ENG 2 PUMP WHICH LED TO EMER LANDING IN EWR. MULTIPLE ASSOCIATED SYSTEM FAILURES.-FOUND CAUSE OF LEAK TO BE DAMAGED O-RING AT ENGINE 2 HYD PUMP PRESSURE SWITH IAW TSM 29-13-00-810-804-A. REMOVED AND REPLACED ENG 2 PRESSURESDR GTIA2024090938363Flashlight · inoperativeCA FLASHLIGHT NEAR FEET INOP-REF SPIRIT AIRLINES EMERGENCY EQIPMENT LAYOUT, REPLACED CA FLASH LIGHT IAW CMM 25-60-13 OPS CHECK GOOD AT THIS TIMESDR GTIA2024042838081Bottle · low pressureDURUNG SERVICE CK FOUND L3 DOOR ASSIST BOTTLE LOW PRESSURE -SERVICE L3 DOOR ASSIST BOTLLE IAW AMM 52-10-00SDR GTIA2023122637717Line · damagedGREEN HYD SYSTEM LOST ALL FLUID.-DURING VISUAL INSPECTION FOUND THE HYD PRESSURE PIPE DAMAGED. R/R HYD PRESSURE PIPE IAW AMM 29-11-49. CORRECTIVE ACTION ON LP 3498363-2. AND SERVICE GREEN HYD SYSTEM IAW AMM 12-12-29. A/C OK TO CONTINUE SERVICE.SDR GTIA2023120137666Probe · fault messageAT FL 340 ENG #1 EGT 273* ENG #2 EGT 403* ALL OTHER INDICATIONS NORMAL NO ECAM FAULT NO EXCEEDED LIMITATIONS-R/R TWO EGT PROBES IAW AMM 77-21-15 ON ENG #1. FAULT STILL REMAINED. FURTHER TROUBLESHOOTING REQUIRED. REF. LOGPAGE 3253000-2 FOR FURTHER TROUBLESHOOTISDR GTIA2023092637500Unknown · unknownR3 DOOR ASSIST BOTTLE LOW PRESSURE-SVCD R3 DOOR ASSIST BOTTLE TO PROPER PRESSURE IAW AMM 52-10-00SDR GTIA2023052537210Sensor · smokeAVIONICS SMOKE -PERFORMED INSP OF AVIONICS COMPARTMENT & E&E BAYS IAW AMM 05-51-00, NO DEFECTS, R&R (25HK) MIXER TEMP SENSOR IAW AMM 21-63-16. OPS CHECK GOOD, NO ODOR, NO DEFECT, A/C OKAY FOR SERVICE.SDR GTIA2023052237204Door Sill · corrodedCORROSION FOUND ON R4 DOOR SILL. RAF 01 CREATED. SDR SUBMITTED-FABRICATED REPAIR ANGLE AND INSTALLED IAW A321 SRM 53-41-14 FIG 003 AND A321 SRM 53-41-14-300-001 FIG 001 AND A321 SRM 53-41-14-300-001 CAT A REPAIRSDR GTIA2023052237203Galley · damagedG4 GALLEY WORKDECK DISBONDED. RAF 01 CREATED-ACCOMPLISHED TEMP REPAIR OF G4 GALLEY WORK DECK PER RDAF 81224907/016/2023#A CAT C REPAIR LIFE LIMIT 12 MO. FROM EMBODIEMENTSDR GTIA2023012336900Valve · faultedENG 1 BEARING 4 OIL SYS HI PRESS-PERFOMRED TSM 79-20-00-810-809-A, R/R NO.4 SCAVANGE VALVE IAW AMM 79-23-51. OPS CHECK GOOD. NO FUALTS NOTED AT THIS TIMESDR GTIA2022072636556None · noneL3 DOOR ASSIT BOTTLE REQUIRES SERVICE-SERVICED L3 DOOR ASSIST BOTTLE IAW AMM 52-10-00SDR GTIA2022030736310None · noneL3 DOOR ASSIST BOTTLE REQ SERVICE-SERVICED L3 DOOR ASSIST BOTTLE TO PROPER LEVEL IAW AMM 52-10-00. LEAK CHECK OKSDR GTIA2022021736289None · noneFA EMERGENCY FLASH LIGHT TESTER INOP ( FLASHLIGHT AND HOLDERS (FLIGHT DECK OR CABIN) )-R/R FA L4 EMERGENCY FLASH LIGHT I.A.W AMM 33-51-11. OPS CHECK OK. THIS CLEARS DMI # 2849262-1. PLACARD REMOVED. MOC NOTIFIED. DMI LOG UPDATED.SDR GTIA2021122736194Megaphone · strippedFWD MEGAPHONE SET SCREW STRIPPED.-RAR FWD MEGAPHONE IAW SPIRIT EMERGENCY EQUIPMENT DRAWING # A321-EMER EQUIP REV IRSDR GTIA2021120636162Solenoid · fault messageEGT OVERLIMIT #2 ON CLIMB OUT, IDLE , TAXI -IN-PERFORMED TSM 73-00-00-810-840-A R/R 10 STAGE SOLENOID VALVE ON ENG#2 FIN: 4023KS IAW AMM 75-32-53. OPS CHECK GOOD NO FAULTS NOTED ACCOMPLISHED HIGH POWER RUN IAW AMM 71-00-00. A/C OK FOR COMTINUE SERVICES. NO FURSDR GTIA2021101836052None · noneL3 AND R3 DOOR ASSIST BOTTLE NEED SERVICE -SERVICE L3 AND R3 DOOR ASSIST BOTTLE IAW AMM 52-10-00SDR GTIA2021071935880Bottle · low pressureR2 DOOR ASSIST REQURIES NITROGEN SERVICE-SERVICED R2 DOOR ASSIST BOTTLE WITH NITROGEN PER AMM 52-10-00SDR GTIA2020110935431Cabin Pressure · malfunctionedDOOR AFT AVIONICS ECAM AT 14.000' PLANE WAS NOT PRESSURIZING NO OVERWEIGHT LANDING. INSPECTED AND LUBRICATED AFT AVC DOOR SEAL INSPECTED AFT AVIONICS DOOR, IAW AMM 52-41-14. PERFORMED PRESSURIZATION CHECK, IAW AMM 05-53-00 & 21-31-00. A/C OK FOR SERVICE, IASDR GTIA2020080635304Proximity Sensor · malfunctionedCREW REPORTS FWD CARGO DOOR SHOWED OPEN, AFTER TAKE OFF. R & R PROXIMITY SWITCH SENSOR AT FWD CARGO DOOR FIN 28WV AND 34WV IAW AMM 52-71-12. PERFORMED AN OPERATIONAL TEST IAW AMM 52-35-00-720-001-A, AND AMM 31-60-00-860-001.SDR GTIA2020062235209Actuator · malfunctionedENG 1 COMPRESSOR VANE ECAM, ACCOMPLISHED FAULT ISOLATION FOR CLM B25TK IAW TSM 75-30-00-810-849 & 847A. REMOVED & REPLACED NR 1 ENG 2.5 BLEED MASTER ACTUATOR (4021KS) IAW AMM 75-31-42 PB401. COMPLIED WITH AMM SUBTASK 72-32-50-210-051-A WITH FLEXIBLE BORESCOPSDR GTIA2020061835205Actuator · faultyRAPID FUEL DECREASE LEFT WING TANK APU INDICATED AMBER ON FUEL SYSTEM DISPLAY. R & R APU FUEL LP VALVE ACTUATOR IAW AMM 28-29-51. NO DEFECTS NOTED. PRECAUTIONARY PERFORMED ENGINE RUN IAW AMM 71-00-00. NO DEFECTS NOTED.SDR GTIA2019102874740Bottle · low pressureL3 DOOR ASSIST REQ SERVICING-SVC L3 DOOR ASSIST BOTTLE IAW AMM 52-22-00 OPS CHECK GOOD LEAK CHECK GOODSDR GTIA2019090134592Bottle · low pressureDURING WEEKLY CHECK FOUND L3 DOOR ASSIST BOTTLE LOW. SRVCD DOOR IAW AMM 52-10-00.SDR GTIA201908054528Bottle · low pressureL3 DOOR ASSIST BOTTLE IN YELLOW BAND-SVC L3 DOOR ASSIST BOTTLE TO GREEN BAND IAW AMM 52-22-00 LEAK CHECK GOOD.SDR GTIA2019020413128Knob · missingMEGAPHONE BY DOOR L1 MISSING VOLUME KNOB.-R&R MEGAPHONE @ L1 DOOR IAW EMERGENCY EQUIPMENT LAYOUT DRAWING A321-EMER. EQUIP REV IR.SDR GTIA2018111952971Bottle · low pressureL-3 DOOR. LOW PRESSURE ON DOOR ASSIST ACCUMULATOR. -SERVICED L-3 DOOR ASSIST ACCUMULATOR AS PER A.M.M. 52-22-00.SDR GTIA2018111502961Bottle · low pressureL-3 DOOR. LOW PRESSURE ON DOOR ASSIST ACCUMULATOR. -SERVICED L-3 DOOR ASSIST ACCUMULATOR AS PER A.M.M. 52-22-00.SDR GTIA2018092402856Flashlight · inoperativeFO'S FLASHLIGHT INOP. R&R FOS FLASHLIGHT PER DRAWING NK321-232-EQ.SDR GTIA2018090602836Bottle · lowL3 DOOR REQS SVC. SVC'D L3 DOOR ASSIST BOTTLE IAW AMM 52-10-00. 1783 PSI.SDR GTIA2018061107687Bottle · low pressureL3 DOOR ASSIST BOTTLE HAD LOW PRESSURE. SERVICED THE DOOR ASSIST BOTTLE IAW AMM 52-10-00.SDR GTIA2018040102556Bottle · low pressureL3 DOOR ASSIST PRESSURE LOW. SERVICED THE L3 DOOR ASSIST BOTTLE IAW AMM 52-22-00-614-002A.SDR GTIA2018010702336Cylinder · low pressureL3 DOOR DAMPING CYLINDER HAD LOW PRESSURE. SERVICED THE L3 DOOR DAMPING CYLINDER IAW AMM 52-10-00.SDR GTIA2017100802187Cylinder · low pressureDURING WEEKLY CHECK OF MAIN CABIN, FOUND THE L1 DOOR ASSIST ACCUMULATOR BELOW PRESSURE LIMITS. SERVICED THE CYLINDER TO PROPER PRESSURES IAW AMM 52-10-00-614-001.SDR GTIA2017073102129Cylinder · low pressureNR 3 EMERGENCY EXIT DOOR ACCUMULATOR REQUIRES SERVICING. SERVICING THE ACCUMULATOR TO PROPER PRESSURE IAW AMM 52-22-00