N712SY, cancelled Aug 5, 2015
Service difficulty reports · 29
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N712SY' AND deregistration_id = 'N712SY-2015-08-05' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N712SY' AND deregistration_id = 'N712SY-2015-08-05' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR SCNA20150105001Overheat Sensor · false indicationWHEEL WELL FIRE ILLUMINATED ON CLIMB. AIRCRAFT RETURNED TO DEPARTURE. R & R WHEEL WELL OVERHEAT SENSOR ELEMENT.SDR SCNA20141223227Frame · crackedBS 907 FRAME CRACKED AT STR 9L. REPAIRED THE FRAME.SDR SCNA20141223217Bracket · crackedLEFT WING T/E, CRACKED BRACKET ATTACHED TO INBD SIDE OF FLAP DEFLECTION CONTROL ROLLER BRACKET. REMOVED, LOCATED, DRILLED AND INSTALLED NEW BRACKET.SDR SCNA20141223231Frame · crackedBS 727B FRAME CRACKED AT STR 9R. REPAIRED THE FRAME.SDR SCNA20141223218Frame · crackedBS 360, FRAME CRACKED AT STR 9L. REPAIRED FRAME.SDR SCNA20141223219Frame · crackedBS 440, FRAME CRACKED AT STR 9L. REPAIRED THE FRAME.SDR SCNA20141223234Frame · crackedBS 827 FRAME CRACKED AT STR 9R. REPAIRED THE CRACK.SDR SCNA20141223233Frame · crackedFS 747 FRAME CRACKED AT STR 9R RAIL SUPPORT. REPAIRED THE FRAME.SDR SCNA20141223232Frame · crackedFS 727D FRAME CRACKED AT STR 9R. REPAIRED THE FRAME.SDR SCNA20141223230Frame · crackedBS 500C FRAME CRACKED AT STR 9R. REPAIRED THE FRAME.SDR SCNA20141223229Frame · crackedBS 480 FRAME CRACKED AT STR 9R. REPAIRED THE FRAME.SDR SCNA20141223228Frame · crackedBS 400 FRAME CRACKED AT STR 9R. REPAIRED THE FRAME.SDR SCNA20141223226Frame · crackedBS 867 FRAME CRACKED AT STR 9L. REPAIRED THE FRAME.SDR SCNA20141223225Frame · crackedBS 827, FRAME CRACKED AT STRG 9L. REPAIRED THE FRAME.SDR SCNA20141223224Frame · crackedBS 787, FRAME CRACKED AT STR 9L. REPAIRED THE FRAME.SDR SCNA20141223223Frame · crackedBS 747, FRAME CRACKED AT STR 9L. REPAIRED THE FRAME.SDR SCNA20141223222Frame · crackedBS 727D FRAME CRACKED AT STR 9L. REPAIRED THE FRAME.SDR SCNA20141223221Frame · crackedBS 500C FRAME CRACKED AT STR 9L. REPAIRED THE FRAME.SDR SCNA20141223220Frame · crackedBS 500A FRAME CRACKED AT STR 9L. REPAIRED THE FRAME.SDR SCNA20141223216Bracket · crackedRIGHT WING T/E, UPPER SHELF PANEL BRACKET CRACKED INBD OF FLAP DETECTION CONTROL ROLLER BRACKET FWD SIDE OF BULB SEAL BRACKET. R & R SHELF PANEL.SDR SCNA20141223215Bracket · crackedRT WING T/E UPPER SHELF PANEL BULB SEAL BRACKET CRACKED INBD OF FLAP DEFLECTION CONTROL ROLLER BRACKET. R & R SHELF PANEL BRACKET.SDR SCNA20141223235Strap · corrodedAFT CARGO FLOOR SPLICE STRAPS CORRODED. REMOVED CORROSION AND FOUND TO BE OUT OF LIMITS. FABRICATED NEW STRAPS.SDR SCNA20140915112Power Supply · inoperativeNUMEROUS EMERGENCY LIGHTS FAILED TO TEST. R & R LIGHT POWER SUPPLY & BATTERY PACK NEAR FWD ENTRY DOOR LT SIDE & NEAR AFT ENTRY DOOR RT SIDE.SDR SCNA20140120002Hydraulic System · low pressureENG 1A HYDRAULIC LOW PRESSURE LIGHT ILLUMINATED. TURNED PUMP OFF. HYDRAULIC B LOW PRESS LIGHT ILLUMINATED. TURNED PUMP OFF. QUANTITY INDICATED LOSS AT INITIALLY A SLOW RATE TO 69 PERCENT FOR B SYSTEM, THEN RAPID DECREASE TO 30 PERCENT. QTY RETURNED TO 70 PERCSDR SCNA20130513090Bulkhead · crackedAFT BULKHEAD CRACKED BS 1016. REPAIRED AFT PRESSURE BULKHEAD.SDR SCNA20121212090Fire Loop · shortedDURING FINAL DESCENT FOR LANDING, RIGHT WING BODY OVERHEAT ILLUMINATED. MAINTENANCE FOUND THE LEADING EDGE OUTBOARD FIRE DETECTION, FWD RT STRUT FIRE DETECTION, & FWD RT PACK BAY LOOPS SHORTED. REMOVED & REPLACED. OPS CHECKS OK.SDR SCNA20120423003Window Frame · crackedDURING MAINTENANCE INSPECTION, FOUND R3 WINDOW FRAME CRACKED AT FWD LWR FASTENER HOLE. REMOVED CRACKED R3 WINDOW FRAME. INSTALLED NEW R3 WINDOW FRAME.SDR SCNA20120423002Window Frame · crackedDURING MAINTENANCE INSPECTION, FOUND L3 WINDOW FRAME CRACKED AT FWD LWR FASTENER HOLE. REMOVED L3 WINDOW FRAME. INSTALLED NEW L3 WINDOW FRAME.SDR SCNA10007Light · inoperativeDURING ROUTINE MAINTENANCE, FOUND RT OVERWING EMERGENCY DOOR WINDOW LIGHT INOPERATIVE. PLACED RT OVERWING EMERGENCY DOOR LIGHT ON MEL.