N724SW, cancelled Sep 18, 2024
Service difficulty reports · 311
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N724SW' AND deregistration_id = 'N724SW-2024-09-18' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N724SW' AND deregistration_id = 'N724SW-2024-09-18' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR SWAA2022020265518Light · missingEMERGENCY EXIT ?NOT ARMED? ANNUNICATOR LIGHT MISSING ; / [01] INSTALLED NEW EMER EXIT LIGHT NO ARMED KORRY LIGHT PER 33-18-00 (AMM)SDR SWAA2021092823019Panel · elongatedPANEL#194E HAS WORKING COUNTERSINKS AND ELONGATED HOLES. ; PANEL#194E HAS NUMEROUS WORKING COUNTERSINKS AND ELONGATED HOLES. / [01] REMOVED AND REPLACED PER AMM 53-51-21.SDR SWAA2021092823020Panel · elongatedPANEL#193D HAS NUMEROUS WORKING COUNTERSINKS AND ELONGATED HOLES. ; / [01] REMOVED AND REPLACED PANEL PER AMM 53-51-21.SDR SWAA2021080399484Floor Panel · corrodedWHILE WORKING DISCREPANCY FROM LP 1735036; AFT LAV DOOR IS BROKEN; FOUND CORROSION IN FLOOR BELOW DOOR STRIKE PANEL IN AFT LAVATORY. AFT LAVATORY 'B' WAS REPLACED ON TASK CARDS TTG8Q005ZB06 AND TTG8Q005ZB06.SDR SWAA2021042967350Slat · faultyLE FLAPS TRANSIT LIGHT STAYED ILLUMINATED FLAPS 1-5. PERFORMED QRH PROCEDUE & DID A FLAPS 15 LNDG.. GREEN LE FLAPS EXT LIGHT ILLUMINATED UPON SELECTING FLAPS 15. / R&R #1 SLAT PER MM 27-81-21 INDICATION OPS CHECK GOOD PER MM 27-88-21 SLAT POSITION PN # ON 114ASDR SWAA2021040861675Floor Panel · delaminatedPANEL 193B HAS DELAMINATED CORNER AND SEVERAL OVERSIZED HOLES / R&R PANEL I.A.W. A.M.M. 53-51-21 AND S.R.M. 51-40-02; 51-40-05; 51-40-08.SDR SWAA2020101921639Charger · inoperativeBATTERY CHARGER M1669 TEST BUTTON IS INOPERABLE. REMOVED AND REPLACED BATTERY CHARGER M1669 AND PERFORMED GOOD INSTALLATION TEST, PER AMM 33-51-06-960-806. 81136U 07OCT20.SDR SWAA2020101521641Lens · crackedLT OVER WING EXIT DOOR FWD EMERGENCY EXIT SIGN LENS IS CRACKED. REMOVED AND REPLACED LT OVER WING EXIT DOOR FWD EMERGENCY EXIT SIGN LENS, PER AMM 33-51-01-960-801 STEP 2B(1) 4 AND STEP 2B(4).SDR SWAA2020101920512Battery Pack · inoperativeEMERGENCY EXIT LIGHTS COMMON TO BATTERY PACK M1669 ARE INOPERABLE. REMOVED & REPLACED BATTERY PACK M1669, PER AMM 33-51-06-960-805 AND AMM 33-51-00-710-801. 59924C 06OCT20 PERFORMED GOOD OPERATIONAL TEST.SDR SWAA2020101920510Battery Pack · inoperativeEMERGENCY EXIT LIGHTS COMMON TO BATTERY PACK M1672 ARE INOPERABLE. REMOVED & REPLACED AND OF BATTERY PACK M1672, PER AMM 33-51-06-960-805 AND AMM 33-51-00-710-801 59924C 06OCT20. PERFORMED GOOD OPERATIONAL TEST.SDR SWAA2020101920504Lamp · inoperativeLEFT OVERWING EXTERIOR EXIT LIGHT IS OUT. RELAMPED AND PERFORMED GOOD INSTALLATION TEST OF LT OVERWING EXIT EXTERIOR LIGHT, PER AMM 33-51-04-960-801. LENS ASSEMBLY WILL BE REINSTALLED ON NRC U220200.SDR SWAA2020101920505Lamp · burned outRIGHT OVER WING EXIT LIGHT ABOVE HAS BURNED OUT LAMPS. RELAMPED AND PERFORMED GOOD FUNCTIONAL TEST OF RIGHT OVERWING EXIT LIGHT ABOVE, PER AMM 33-51-01-960-801.SDR SWAA2020101520507Lamp · inoperativeLEFT OVER WING EXIT IDENTIFIER FWD SIDE HAS LAMPS OUT. RELAMPED AND PERFORMED GOOD FUNCTIONAL TEST OF LEFT OVERWING EXIT IDENTIFIER FWD SIDE, PER AMM 33-51-01-960-801.SDR SWAA2020101520506Lamp · inoperativeRIGHT OVER WING EXIT IDENTIFIER FWD SIDE HAS LAMPS OUT. RELAMPED AND PERFORMED GOOD FUNCTIONAL TEST OF RIGHT OVERWING EXIT IDENTIFIER FWD SIDE, PER AMM 33-51-01-960-801.SDR SWAA2021081520490Shield · corrodedSHIELD AFT OF FWD CARGO DOOR HAS CORROSION AROUND NUT PLATE HOLES BS500 TO BS500A RBL23 WL156 / EVALUATED CORROSION ON SHIELD AFT OF FWD CARGO DOOR FOUND TO BE OUT OF LIMITS DUE TO NO SRM LIMITS; REPLACEMENT REQUIRED IAW SRM 51-10-02-0G-0 PARA 9. REMOVED AND RSDR SWAA2021081618859Support · corrodedAFT CARGO BAY R/H FLOOR TO SIDEWALL SUPPORT PLATE HAS CORROSION AROUND NUT PLATE HOLES BETWEEN BS747 AND BS767 RBL21 WL156 / EVALUATED CORROSION ON ACB RH FLOOR TO SIDEWALL SUPPORT; REMOVED; .015' FROM ORIG .040'; FOUND TO BE OUT OF LIMITS; IAW SRM 53-00-53-1ASDR SWAA2021081318860Web · corrodedAFT CARGO BAY VERTICAL WEB BETWEEN BS767 AND BS787 RBL6 WL151 HAS CORROSION AROUND FASTENERS / VERTICAL WEB BS 767 - 787 RBL 6 WL 151; FOUND TO BE OUT OF LIMITS DUE TO NO SRM LIMITS. REMOVED AND REPLACED VERTICAL WEB PER SRM 51-40-02-0G-0; SRM 51-40-05-0G-0; DSDR SWAA2021081218874Seat Track · corroded***CORROSION*** CORROSION IN VARIOUS LOCATIONS ON SEAT TRACK IN WELL; BS 480-520; LBL 45; WL 208. MARKED. / SEAT TRACK TO BE REPLACED ON U129849.SDR SWAA2021042718861Stringer · corrodedCORROSION COMMON TO END OF STR25R IN SNAKE PIT BS536 WL154 / REPAIRED STR 25 R/H IN FCB SNAKE PIT BS 536 WL154 PER ER 20-03337 REV IR AND EA 20-153-01958 REV IRSDR SWAA2020101918862Stringer · crackedSTR 26L IS CRACKED COMMON TO END OF STRINGER IN SNAKE PIT BS 536 WL 152. REMOVED DAMAGED SECTION OF STR 26-L AND INSTALLED REPAIR PARTS AT S-26L BS500D+4'-540, IAW SRM 53-00-03-2R-1 AND DWG 143A3230; 143A1215.SDR SWAA2020101518876Seat Track · damagedMECHANICAL DAMAGE ON SEAT TRACK ON CROWN BS 519-520; LBL 45; WL 208, MARKED. REMOVED DAMAGE ON SEAT TRACK CROWN BS 519-520; LBL 45; WL 208. MAX MATERIAL REMOVED WAS 0.030' 1' X 1' ON TOP, PER SRM 51-10-02-0G-0. DAMAGE FOUND TO BE OUT OF LIMITS, PER SRM 53-SDR SWAA2020091115145Skin · cracked1 EACH CRACK FOUND FUSELAGE CROWN SKIN FS 767 2 RIGHT OF STRINGER 1R AND 11' AFT FS 767 AND CRACK IS 0.75' LONG. REPAIRED PER EA 20-153-01667 INTERIM REPAIR SEE 943.SDR SWAA2020090914363Stringer · crackedDURING INSPECTION IN SI 12095 FOUND 0.75' CRACK 2' R OF STRINGER 1 AND 11' AFT OF BS 767 ON FUSELAGE CROWN SKIN. TRANSFERRED TO LP 1450217.SDR SWAA2021080309775Floor Panel · damagedFWD CARGO FLOOR PANEL 120CF DAMAGED / REMOVED AND REPLACED FWD CARGO FLOOR PANEL 120CF IAW AMM 25-52-01SDR SWAA2020082009773Cover · out of positionAFT SERVICE DOOR EMERGENCY SLIDE; PULL HANDLE COVER IS NOT IN PLACE. REPOSITIONED AFT SERVICE DOOR EMERGENCY SLIDE; PULL HANDLE COVER PER MT 725-61-06.SDR SWAA2020011340437Battery · failedEMERGENCY LIGHT BATTERY FAILED CAPACITY TEST AT LOCATION M1674. / R&R BATTERY PER AMM.SDR SWAA2020011340436Battery · failedEMERGENCY LIGHT BATTERY FAILED CAPACITY TEST AT LOCATION M1673. / R&R BATTERY PER AMM.SDR SWAA2020011340435Battery · failedEMERGENCY LIGHT BATTERY FAILED CAPACITY TEST AT LOCATION M1675. / R&R BATTERY PER AMM.SDR SWAA2020011340434Battery · failedEMERGENCY LIGHT BATTERY FAILED CAPACITY TEST AT LOCATION M1669. / R&R BATTERY PER AMM.SDR SWAA2020011340433Battery · failedEMERGENCY LIGHT BATTERY FAILED CAPACITY TEST AT LOCATION M1672. / R&R BATTERY PER AMM.SDR SWAA2020011340432Battery · failedEMERGENCY LIGHT BATTERY FAILED CAPACITY TEST AT LOCATION M1671. / R&R BATTERY PER AMM.SDR SWAA2020011340386Battery · failedEMERGENCY LIGHT BATTERY FAILED CAPACITY TEST AT LOCATION M1668. / R&R BATTERY PER AMM.SDR SWAA2019042231873Cover · missingAFT SERVICE DOOR FO SIDE LOWER EXIT LIGHT COVER MISSING REPLACED COVER AS REQUIRED REF SIP & AMM 33-51-01SDR SWAA2019030830460Intercostal · crackedINTERCOSTAL CRACKED BETWEEN BS 328 TO BS 344, LBL 45. R&R INTERCOSTAL IAW SRM & DWG.SDR SWAA2019030830459Intercostal · crackedINTERCOSTAL CRACKED BETWEEN BS 312 TO BS 328, LBL 45. R&R INTERCOSTAL IAW SRM & DWG.SDR SWAA2019030830458Intercostal · crackedINTERCOSTAL CRACKED BETWEEN BS 270 TO BS 294.5, RBL 1. R&R INTERCOSTAL IAW DWG & SRM.SDR SWAA2019030830457Floorboard · damagedPASSENGER CABIN, FLOORBOARD 222BF DAMAGED INSERTS. REPAIRED FLOORBOARD IAW SRM & DWG.SDR SWAA2019030830456Floorboard · damagedPASSENGER CABIN, FLOORBOARD 222CF DAMAGED AT EDGE AND INSERTS. REPAIRED FLOORBOARD IAW SRM & DWG.SDR SWAA2019030830454Intercostal · crackedFORWARD GALLEY AREA INTERCOSTAL CRACKED BETWEEN BS 294.5 TO BS 312, RBL 15. R&R INTERCOSTAL PER SRM & DWG.SDR SWAA2019030830453Intercostal · crackedINTERCOSTAL CRACKED BETWEEN BS 312 TO BS 328, RBL 30. R&R INTERCOSTAL IAW SRM & DWG.SDR SWAA2019030830452Floorbeam · crackedFLOORBEAM CRACKED AT BS 328 RBL 20 NEAR FLOOR BOARD SCREW HOLE. REPAIRED FLOORBEAM PER SRM.SDR SWAA2022022572347Intercostal · crackedFOUND INTERCOSTAL CRACKED IN FWD. GALLEY AREA AT LOCATION 15 RBL BETWEEN STA 294.5 AND STA 312 / DEFECT TRANSFERRED TO NON ROUTINE CARD # T918557SDR SWAA2022022572365Intercostal · crackedINTERCOSTAL BETWEEN STA 312 AND STA328 30' RBL IS CCRACKED. / TRANSFERRED TO LOG PAGE 0927735SDR SWAA2022022572367Intercostal · crackedFOUND INTERCOSTAL CRACKED IN FWD GALLEY AREA AT LOCATION 15 RBL BETWEEN STATION 294.5 AND 312. / TRANSFERRED TO LOG PAGE 0927736SDR SWAA2019021329552Module · faultyON APPROACHED WITH GEAR HANDLE DOWN RECEIVED 3-RED & 3 -GREEN GEAR INDICATIONS. RECYCLED GEAR HANDLE GEAR EXTENDED NORMALLY WITH 3-GREEN INDICATIONS. R&R LANDING GEAR CONTROL LEVER MODULE PER AMM.SDR SWAA2019011728598Lens · unsecureR2 DOOR ABOVE EMERGENCY EXIT LIGHT LENS UNSECURE. R&R LIGHT ASSEMBLY IAW AMM.SDR SWAA2022030172865Panel · crackedRIGHT WING LOWER LEADING EDGE PANEL 621NB AFT INBOARD CORNER SEPARATING/CRACKED. / REPAIRED R/H WING LOWER L/E PANEL 621NB AFT IB CORNER IAW B737-700 SRM 57-41-01-2R-1 REPAIR 1 REV 66.SDR SWAA2019011628458Floor Support · corrodedAFT CARGO FLOOR SUPPORT RAIL CORRODED AT BS 767+6, LBL 8. R&R RAIL IAW EA.SDR SWAA2019011527960Guard · damagedCOCKPIT P5 PANEL EMERGENCY EXIT LIGHT SWITCH GUARD DAMAGED. R&R SWITCH GUARD IAW MM.SDR SWAA2022030172852Stanchion · corrodedAFT PIT SIDE WALL EXTRUSION REMOVED FOR WASTE TANK REMOVAL HAS CORROSION AROUND BOLT HOLE / REMOVED DAMAGE ON AFT PIT SIDE WALL EXTRUSION FOR WASTE TANK SIDEWALL EVALUATED DAMAGE REMOVED AND FOUND TO BE 100% MATERIAL LOSS. OUT OF LIMITS. LOCATED AND DRILLED NE
Back to N724SW, cancelled Sep 18, 2024