N741AS, cancelled May 1, 2007
Service difficulty reports · 319
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N741AS' AND deregistration_id = 'N741AS-2007-05-01' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N741AS' AND deregistration_id = 'N741AS-2007-05-01' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR ASAA9910118Support · crackedPHX - DURING D-CHECK, FOUND THE R-1 SERVICE DOOR FRAME SUPPORT, TOP AFT LOCATION 332 RT CRACKED. REPAIRED PER SB 737-53-1108, REV 5. (X)SDR ASAA9910117Skin · gougedPHX - DURING D-CHECK, FOUND THE FUSELAGE AT STA 685 BETWEEN STR 4L AND STR 5L GOUGED. REPAIRED PER SRM 53-30-3, FIG 2. (X)SDR ASAA9910116Seat Track · corrodedPHX - DURING D-CHECK, FOUND THE PASSENGER CABIN SEAT TRACK CORRODED ON TOP AND BOTTOM SIDES AT BS 727A TO BS 727B, RBL 62.5. REPAIRED PER SRM 53-10-5, FIG 7. (X)SDR ASAA9910115Floorbeam · corrodedPDX - DURING C-CHECK, FOUND THE PASSENGER CABIN STUB FLOORBEAM CORRODED AROUND FASTENER HOLES ON TOP SIDE, BS 727, RBL 54.0. REPAIRED PER DWG 65-46547; SRM 53-10-1. (X)SDR ASAA9910114Skin · corrodedPDX - DURING D-CHECK, FOUND THE EXTERNAL FUSELAGE SKIN FROM BS 787 TO BS 907, STR 20R TO STR 26R LIGHTLY PITTED WITH CORROSION. REPAIRED PER SRM 51-10-1 AND SRM 51-30-2. (X)SDR ASAA9910113Support · corrodedPHX - DURING D-CHECK, FOUND THE LONGITUDINAL SEAT TRACK SUPPORTS CORRODED AT BS 580 - BS 727B, LBL 24.5, BL ZERO, RBL 24.5 AND RBL 45.5. REPAIRED PER EA 5320-01373. (X)SDR ASAA9910112Floorbeam · corrodedPHX - DURING D-CHECK, FOUND THE MAIN CABIN FLOORBEAM CORRODED ON TOP AND BOTTOM SIDES OF FLANGE AT BS 727B, BL ZERO TO 56. REPAIRED PER SRM 51-40-3. (X)SDR ASAA9910111Keel Beam · corrodedPHX - DURING D-CHECK, FOUND THE EXTERNAL FUSELAGE LOWER SIDE, KEEL BEAM 27L BETWEEN STA 727 - STA 727A CORRODED ON BOTTOM SIDE. REPAIRED PER EA 5310-01687. (X)SDR ASAA9910110Keel Beam · corrodedPHX - DURING D-CHECK, FOUND THE EXTERNAL FUSELAGE LOWER SIDE, KEEL BEAM 27R BETWEEN STA 727 - STA 727A CORRODED ON BOTTOM SIDE. REPAIRED PER EA 5310-01687. (X)SDR ASAA9910109Frame · corrodedPHX - DURING D-CHECK, FOUND AFT CARGO PIT FRAME AT BS 987 CORRODED FROM STR 18L TO STR 18R. REPAIRED PER SRM 51-30-2. (X)SDR ASAA9910108Stringer · corrodedPHX - DURING D-CHECK, FOUND AFT CARGO PIT STRINGER 24R, AT APPROXIMATELY BS 962, CORRODED. REPAIRED PER SRM 53-10-3. (X)SDR ASAA9910107Frame · corrodedPHX - DURING D-CHECK, FOUND EXTERNAL FUSELAGE, LOWER SIDE FRAME AT STA 727 FROM STR 26L TO STR 26R CORRODED ON BOTTOM SIDE. REPAIRED PER SRM 51-30-2. (X)SDR ASAA9910106Stringer · corrodedPHX - DURING C-CHECK, FOUND AFT CARGO PIT STR 27L CORRODED FROM BS 947 TO BS 987. REPAIRED PER SRM 53-10-2, FIG 9. (X)SDR ASAA9910105Skin · gougedPHX - DURING C-CHECK, FOUND EXTERNAL FUSELAGE SKIN AT BS 907, STR 10L, GOUGED. REPAIRED PER SRM 53-30-3, FIG. 16. (X).SDR ASAA9910104Stringer · corrodedPHX - DURING D-CHECK, FOUND STR 25R, BS 294.5 TO BS 348, CORRODED. REPAIRED PER SRM 53-10-3. (X)SDR ASAA9910103Stringer · corrodedPHX - DURING D-CHECK, FOUND STR 26R, BS 322 TO BS 326, CORRODED. REPAIRED PER SRM 53-10-3. (X)SDR ASAA9910102Bulkhead Chord · damagedPHX - DURING D-CHECK, FOUND BS 178 BULKHEAD VERTICAL CHORD, LBL 5.7 AND WL 195, PUNCTURED AND CRACKED. REPAIRED PER SRM 53-10-11, FIG 8. (X)SDR ASAA9910098Beam · corrdoedPHX - DURING D-CHECK, FOUND THE PASSENGER CABIN FLOOR SUPPORT I BEAM CORRODED ON TOP AND BOTTOM SIDES, BS 663, RBL 45.5 TO 61.0. REPAIRED PER SRM 51-30-2 AND 51-30-3. (M)SDR ASAA9910097Skin · crackedPHX - DURING D-CHECK, FOUND EXTERNAL SKIN CENTER LINE BS 422 TO 426 BETWEEN STRINGER 28L AND 28R CRACKED. REPAIRED PER SRM 53-30-3 AND 53-30-4. (M)SDR ASAA9910001Snubber · inoperativeANC - PRIOR TO FLT 22, THE LT AFT ENTRY DOOR HANDLE WAS DIFFICULT TO OPERATE. REPLACED SNUBBER AND LUBRICATED DOOR, DOOR OPERATED NORMALLY. ACFT TT: 51,541 HOURS. ACFT TC: 45,577. (X)SDR ASAA9810112Pin · crackedANC - FLT 147 - THE CAPTAINS SLIDING WINDOW WAS FOUND TO BE HARD TO CLOSE. INSPECTED AND FOUND THE GUIDE PIN CRACKED. REPLACED THE CAPTAINS SLIDING WINDOW AND THE WINDOW OPERATED NORMALLY. (M)SDR ASAA9810110Battery · dischargedANC - DURING MAINTENANCE CHECK, THE SMOKE BARRIER EMERGENCY LIGHT WAS FOUND TO BE INOPERATIVE. REPLACED BATTERY AND LIGHT OPERATED NORMALLY. (M)SDR ASAA9810102Battery · dischargedSEA - DURING MAINTENANCE CHECK, THE EMERGENCY EXIT FLOOR TRACK LIGHTS WERE FOUND TO BE INOPERATIVE AT ROW 12. REPLACED BATTERY AND LIGHTS OPERATED NORMALLY. (M)SDR ASAA9810100Battery Pack · dischargedANC - PRIOR TO FLT 124 - THE EMERGENCY EXIT FLOOR TRACK LIGHTS ILLUMINATED. REPLACED BATTERY PACK AND LIGHTS OPERATED NORMALLY. (M)SDR ASAA9810039Battery Pack · dischargedSEA - DURING MAINTENANCE CHECK, THE FIRST CLASS EMERGENCY EXIT FLOOR TRACK LIGHT LEFT TRANSMITTER WAS FOUND TO BE INOPERATIVE. REPLACED BATTERY PACK AND LIGHTS OPERATED NORMALLY. (M)SDR ASAA9810037Battery Pack · dischargedANC - DURING MAINTENANCE CHECK, THE EMERGENCY EXIT FLOOR TRACK LIGHTS AT ROW 2 WERE FOUND TO BE INOPERATIVE. REPLACED BATTERY PACK AND LIGHTS OPERATED NORMALLY. (M)SDR ASAA9810034Battery Pack · dischargedANC - FL 43 - DURING PREFLIGHT, CREW REPORTED THAT THE EMERGENCY EXIT TRACK LIGHTS AT PALLET 6-2 WOULD NOT EXTINGUISH AFTER TEST. REPLACED BATTERY PACK AT PALLET 6-2 AND LIGHTS OPERATED NORMALLY. (M)SDR ASAA9810031Rib · wornSEA - DURING C-CHECK, WEAR WAS FOUND AT THE HORIZONTAL STABILIZER TRAILING EDGE RIBS AT STATION 66.54, 94.07, AND 121.9. REPAIRED PER EA 5510-01066 AND BOEING TELEX'S ASA-SEA-91-0202RR AND ASA-SEA-97-004RR. (M)SDR ASAA9810030Floorbeam · corrodedSEA - DURING C-CHECK. FOUND CORROSION WAS FOUND IN THE LOWER FORWRD FLANGE OF THE FLOORBEAM AROUND A FASTENER HOLE AT STATION 500, LBL 9. REPAIRED PER EA 5310-01579. (M)SDR ASAA9810029Angle · crackedSEA - DURING C-CHECK, CRACKS WERE FOUND IN THE LEFT UPPER WING TO BODY DRAG ANGLE AND FRAME SPLICE ANGLE. REPLACED ANGLE PER EA 5310-01572. (M)SDR ASAA9810016Battery · dischargedANC - FLT 30 - PRIOR TO FLT, THE EMERGENCY EXIT TRACK LIGHTS WERE FOUND TO BE INOPERATIVE AT PALLET POSITION 9. REPLACED BATTERY AND LIGHTS OPERATED NORMALLY. (M)SDR ASAA981009Battery · dischargedSEA - DURING MAINTENANCE CHECK, THE SMOKE BARRIER EMERGENCY EXIT LIGHTS WERE FOUND TO BE DIM. REPLACED BATTERY TO SMOKE BARRIER LIGHT ASSEMBLY AND LIGHTS OPERATED NORMALLY. (M)SDR ASAA9810004Light · inoperativeANC - DURING MAINTENANCE CHECK, AN EMERGENCY EXIT FLOOR TRACK LIGHT WAS FOUND TO BE INOPERATIVE AT ROW 20. RELEASED PER MEL 33-19. SUBSEQUENTLY REPAIRED LIGHT ASSEMBLY AT ROW 20 AND LIGHT OPERATED NORMALLY. (M)SDR ASAA9710138Mechanism · lack of lubeANC - DURING MAINTENANCE CHECK, THE L2 DOOR WAS FOUND DIFFICULT TO MOVE THROUGH FULL TRAVEL OF OPEN TO CLOSE. CLEANED AND LUBRICATED L2 DOOR AND DOOR OPERATED NORMALLY. ACFT TT: 48,253 HOURS. ACFT TC: 42,759. (X)SDR ASAA9710135Latch Mechanism · lack of lubeANC - FLT 46 - DURING GROUND OPERATIONS, THE LEFT AFT ENTRY DOOR, AIRSTAIR WAS VERY DIFFICULT TO CLOSE. INSPECTED LEFT AFT DOOR HINGE AND LATCH MECHANISM, NO DEFECTS NOTED. LUBED DOOR HINGES AND LATCH MECHANISM, DOOR OPERATED NORMALLY. (M)SDR ASAA9710097Wire · brokenANC - DURING RECON, FOUND THE LAST FIVE EMERGENCY EXIT FLOOR TRACK LIGHTS WERE INOPERATIVE. REPAIRED BROKEN WIRE AND LIGHTS OPERATED NORMALLY. (M)SDR ASAA9710092Battery Pack · dischargedSEA - DURING MAINTENANCE CHECK, THE EMERGENCY EXIT FLOOR TRACK LIGHTS WERE FOUND TO BE INOPERATIVE AT ROWS 6 AND 7. REPLACED BATTERY PACK AND LIGHTS OPERATED NORMALLY. (M)SDR ASAA9710065Battery Pack · dischargedANC - DURING MAINTENANCE CHECK, THE EMERGENCY EXIT LIGHTS ON PALLET 4-5 WERE FOUND TO BE INOPERATIVE. REPLACED BATTERY PACK AND LIGHTS OPERATED NORMALLY. (M)SDR ASAA9710037Module · inoperativeSEA - DURING MAINTENANCE CHECK, THE EMERGENCY EXIT FLOOR TRACK LIGHTS CYCLED ON AND OFF. REPLACED FORWARD CONTROL MODULE AND LIGHTS OPERATED NORMALLY. (M)SDR ASAA9710029Battery · dischargedSEA - DURING MAINTENANCE, THE EMERGENCY EXIT FLOOR TRACK LIGHTS WERE FOUND TO BE INOPERATIVE AT PALLET 2. REPLACED BATTERY AND RECEIVER AND LIGHTS OPERATED NORMALLY. (M)SDR 97ZZZM577Receiver · inoperativeSEA - DURING MAINTENANCE, THE EMERGENCY EXIT FLOOR TRACK LIGHTS WERE FOUND TO BE INOPERATIVE AT PALLET 2. REPLACED BATTERY AND RECEIVER AND LIGHTS OPERATED NORMALLY. REFERENCE ASAA9710029.SDR ASAA9710020Transmitter · inoperativeSEA - DURING MAINTENANCE CHECK, THE MID CABIN EMERGENCY EXIT FLOOR TRACK LIGHT TRANSMITTER WAS FOUND TO BE INOPERATIVE. REPLACED TRANSMITTER AND LIGHTS OPERATED NORMALLY. (M)SDR ASAA9710017Slide Bottle · low pressureSEA - DURING SCHEDULED MAINTENANCE, THE L1 DOOR EMERGENCY EVACUATION SLIDE INFLATION BOTTLE PRESSURE WAS FOUND LOW. REPLACED THE EMERGENCY EVACUATION SLIDE. (M)SDR ASAA9710015Support Beam · wornSEA - DURING C-CHECK, THE RIGHT MAIN LANDING GEAR SUPPORT BEAM WAS IDENTIFIED WITH A WEAR MARK ON THE RIGHT SIDE UPPER FLANGE, FORWARD EDGE. REPAIRED PER EA 5740-01126 AND BOEING TELEX ASA-SEA-97-0037RR. (M)SDR ASAA9710014Skin · crackedSEA - DURING C-CHECK, THE FUSELAGE SKIN WAS FOUND CRACKED AT THE AFT END OF THE CUTOUT FOR THE COOLING EXHAUST DUCT, BS 380, BL 0. REPAIRED PER EA 5330-01275 AND BOEING SERVICE BULLETIN 737-53-1117. (M)SDR ASAA9710013Floor Beam · corrodedSEA - DURING C-CHECK, THE FLOOR BEAM UPPER FORWARD FLANGE AT BS 344 WAS FOUND TO BE CORRODED. REPAIRED PER EA 5310-01509 AND BOEING TELEX ASA-SEA-97-0039RR. (M)SDR ASAA9710012Floor Beam · corrodedSEA - DURING C-CHECK, THE FLOOR BEAM UPPER FORWARD FLANGE AT BS 1006 WAS FOUND TO BE CORRODED. REPAIRED PER EA 5310-01508 AND BOEING TELEX ASA-SEA-97-0038RR. (M)SDR ASAA9710011Chord · crackedSEA - DURING C-CHECK, THE COMPENSSION CHORD AT BS 727 WAS FOUND CRACKED IN THE RADIUS AT BL 0.0. COMPLETED INTERMIN REPAIR PER EA 5310-01506 AND BOEING SERVICE BULLETIN 737-53-1072. CHORD REQUIRES REPLACEMENT AT NEXT D-CHECK. (M)SDR ASAA9710010Evac Slide · wornSEA - DURING CHECK, THE FORWARD ENTRY DOOR EMERGENCY ESCAPE SLIDE GIRT LOWER SIDE WAS FOUND TO BE WORN IN FABRICATED. REPLACED FORWARD ENTRY DOOR EMERGENCY ESCAPE SLIDE. (M)SDR ASAA9710005Hinges · lack of lubeSEA - FLT 65 - PRIOR TO DEPARTURE, CREW REPORTED THE L1 DOOR WAS HARD TO CLOSE. MAINTENANCE CLEANED AND LUBED THE UPPER AND LOWER DOOR HINGES, AND THE DOOR OPERATED NORMALLY. (M)
Back to N741AS, cancelled May 1, 2007