N7508, cancelled Aug 31, 2015

Service difficulty reports · 105

Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.

Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy
  FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet'
  WHERE n_number = 'N7508' AND deregistration_id = 'N7508-2015-08-31'
  ORDER BY difficulty_date DESC"

Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.

SDR AALA20150225001Module · inoperativeFORWARD CABIN SEAT MOUNTED ESCAPE PATH LIGHTS STAYED ON AFTER TEST. REPLACED POWER SUPPLY MODULE & BATTERY. SYS CHECKED NORMAL.Feb 24, 2015 · N7508 · Doug DC982 · Emergency LightingSDR AALA20140615001Battery Pack · dischargedONE STRING OF EMER LIGHTS FROM STATIONS 218 TO 225 INOPERATIVE. REPLACED BATTERY PACK. OPERATIONS CHECKED NORMAL.Jun 15, 2014 · N7508 · Doug DC982 · Emergency LightingSDR AALA20140402004Casting · crackedRIGHT WING, GROUND SPOILER CASTING INBD FWD CORNER CRACKED. REPLACED CASTING IAW AARD 51-00-05.Apr 2, 2014 · N7508 · Doug DC982 · SpoilersSDR AALA20140401009Longeron · crackedAFT ACCESSORY LONGERON 2 LT CRACKED AT AFT SIDE OF BS 1418. INSTALLED LONGERON & SPLICE DOUBLER IAW SRM 53-02-00 FIGURE 18.Apr 1, 2014 · N7508 · Doug DC982 · Fuselage Main, Longeron/StringerSDR AALA20140324005Rib · crackedRT NR 4 SLAT RIB CASTING FOUND CRACKED. INSTALLED DOUBLER REPAIR.Mar 24, 2014 · N7508 · Doug DC982 · Leading Edge DevicesSDR AALA20140324004Rib · crackedLT NR 4 SLAT RIB CASTING FOUND CRACKED. INSTALLED REPAIR DOUBLER.Mar 24, 2014 · N7508 · Doug DC982 · Leading Edge DevicesSDR AALA20130616003Clamp · leakingTAIL COMPARTMENT HIGH TEMPERATURE INDICATION DURING CLIMB. EMERGENCY DECLARED FLIGHT RETURNED DFW LANDED WITHOUT INCIDENT. TIGHTENED LEAKING INBOUND CLAMP AT RT HAND AUGMENTATION VALVE. SYSTEM GROUND CHECKED NORMAL OPERATION.Jun 16, 2013 · N7508 · Doug DC982 · Air Distribution SystemSDR AALA20130608001Clamp · leakingCREW REPORTED TAIL COMPARTMENT HIGH TEMPERATURE INDICATION. EMERGENCY DECLARED, FLIGHT RETURNED TO DEPARTURE, LANDED WITHOUT INCIDENT. ACFT REMOVED FROM SERVICE. SECURED LOOSE CLAMP ON RT ACM TO HEAT EXCHANGER AND SECURED LOOSE BOOT ON DUCT DOWN STREAM OF TEJun 7, 2013 · N7508 · Doug DC982 · Air Distribution SystemSDR AALA20130528013Acm · inoperativeCREW REPORTED TAIL COMPARTMENT TEMPERATURE HIGH LIGHT ILLUMINATED. EMERGENCY DECLARED, FLIGHT RETURNED TO DEPARTURE, LANDED WITHOUT INCIDENT. ACFT REMOVED FROM SERVICE. REPLACED LT AUG VALVE SENSE LINE AND RT AIR CYCLE MACHINE. SYS GROUND CHECK NORMAL OPERMay 28, 2013 · N7508 · Doug DC982 · Cabin Cooling SystemSDR AALA20120927018Cusp Web · crackedCRACK IN RIGHT CUSP AT STATION 803 OUTBOARD OF NUMBER 6 SEAT TRACK. INSTALLED DOUBLER PER AARD 53-20-00-16.Sep 27, 2012 · N7508 · Doug DC982 · Fuselage Miscellaneous StructureSDR AALA20120927017Cusp Web · corrodedCORROSION ON CUSP TEE TAB AT RIGHT STATION 200. INSTALLED DOUBLER PER AARD 53-20-00-14.Sep 27, 2012 · N7508 · Doug DC982 · Fuselage Miscellaneous StructureSDR AALA20120927016Membrane · corrodedCORROSION ON THE SUB FLOOR STATIONS 180 TO 200, 6 INCHES INBOARD OF THE FORWARD SERVICE DOOR SILL. INSTALLED DOUBLER PER AARD 53-20-00-16.Sep 27, 2012 · N7508 · Doug DC982 · Fuselage Miscellaneous StructureSDR AALA20120927015Membrane · corrodedCORROSION ON THE SUB FLOOR STATIONS 200 TO 210, OUTBOARD OF THE NUMBER 5 SEAT TRACK. INSTALLED DOUBLER PER AARD 53-20-00-16Sep 27, 2012 · N7508 · Doug DC982 · Fuselage Miscellaneous StructureSDR AALA20120927014Cusp Web · corrodedLEFT SUBFLOOR AT STATION 1165 CORRODED. INSTALLED DOUBLER PER AARD 53-20-00-16.Sep 27, 2012 · N7508 · Doug DC982 · Fuselage Miscellaneous StructureSDR AALA20120927013Cusp Web · corrodedLEFT SUBFLOOR AT STATION 1155 CORRODED. INSTALLED DOUBLER PER AARD 53-20-00-16.Sep 27, 2012 · N7508 · Doug DC982 · Fuselage Miscellaneous StructureSDR AALA20120927012Cusp Web · crackedRIGHT CUSP CRACKED FROM STATIONS 466 TO 468. INSTALLED DOUBLER PER AARD 53-20-00-16.Sep 27, 2012 · N7508 · Doug DC982 · Fuselage Miscellaneous StructureSDR AALA20120927011Cusp Web · corrodedRIGHT CUSP AT STATION 839 HAS CORROSION UNDER RIVET ABOVE CUSP TEE. INSTALLED DOUBLER PER AARD 53-20-00-16.Sep 27, 2012 · N7508 · Doug DC982 · Fuselage Miscellaneous StructureSDR AALA20120927010Longeron · crackedLONGERON 3 LEFT HAS A CRACK INDICATION AT STATION 180, 1 INCH THE RADIUS OF THE OUTBOARD LEG. INSTALLED SPLICE REPAIR PER SRM 53-02-00 FIGURE 18.Sep 27, 2012 · N7508 · Doug DC982 · Fuselage Main, Longeron/StringerSDR AALA20120927009Cusp Web · corrodedRIGHT CUSP AT STATION 1010 CORRODED AROUND LIGHTENING HOLE. INSTALLED DOUBLER PER AARD 53-20-00-16Sep 27, 2012 · N7508 · Doug DC982 · Fuselage Miscellaneous StructureSDR AALA20120927007Cusp Web · corrodedCORROSION ON CUSP T AT STATION 168, LONGERON 18 RIGHT. INSTALLED DOUBLER PER AARD 53-20-00-14.Sep 27, 2012 · N7508 · Doug DC982 · Fuselage Miscellaneous StructureSDR AALA20120925014Pan · wornPAN WORN UNDER LOWER FORWARD STRAP FITTING. INSTALLED DOUBLER REPAIR PER AARD 52-30-00-01 AND EA COMP-52-026208.Sep 25, 2012 · N7508 · Doug DC982 · Cargo/Baggage DoorsSDR AALA20120919026Mount · corrodedG-2 GALLEY INBOARD MOUNT IS CORRODED ON THE SURFACE AND IN THE BORE STATION 218 RIGHT BUTTLINE 11. INSTALLED NEW SERVICEABLE G-2 GALLEY MOUNT FITTING AT STATION 218, RIGHT BUTTLINE 11 PER SRM 51-00-05-1.Sep 19, 2012 · N7508 · Doug DC982 · Fuselage, Equipment Attach FittingsSDR AALA20120919022Attach Bracket · crackedRIGHT WING NUMBER 5 LEADING EDGE SECOND FROM OUTBOARD TRACK ATTACH BRACKET CRACKED. REMOVED CORROSION AND INSTALLED DOUBLER PER AARD 57-43-00-3.Sep 19, 2012 · N7508 · Doug DC982 · Leading Edge DevicesSDR AALA20120829008Portable Light · inoperativeLEFT NUMBER 1 DOOR EMERGENCY PORTABLE LIGHT INOPERATIVE. REMOVED AND REPLACED PORTABLE BATTERY LIGHT. OPS CHECK NORMAL.Aug 28, 2012 · N7508 · Doug DC982 · Emergency LightingSDR AALA20120829007Battery Pack · dischargedAFT CABIN ESCAPE PATH LIGHT INOPERATIVE. REPLACED AFT CABIN BATTERY PACK. OPS CHECK NORMAL.Aug 28, 2012 · N7508 · Doug DC982 · Emergency LightingSDR AALA20120829006Battery Pack · dischargedFORWARD CABIN ESCAPE PATH LIGHT INOPERATIVE. REPLACED FORWARD BATTERIES PACK. OPS CHECK NORMAL.Aug 28, 2012 · N7508 · Doug DC982 · Emergency LightingSDR AALA20120829005Light · damagedESCAPE PATH LIGHT SIGN ACROSS FROM FIRST CLASS LAVATORY. FOUND LAMPS AT SEAT 20D DAMAGED, CREATING DEAD SHORT. REPLACED LAMP FOR SEAT 20D ESCAPE PATH LIGHT. OPS CHECK NORMAL.Aug 28, 2012 · N7508 · Doug DC982 · Emergency LightingSDR AALA20120829004Battery · not seatedRIGHT AND CENTER CEILING EMERGENCY LIGHTS, BETWEEN AFT LAVATORIES INOPERATIVE. RESEATED EMERGENCY LIGHT BATTERY (AFT). OPS CHECK NORMAL.Aug 28, 2012 · N7508 · Doug DC982 · Emergency LightingSDR AALA20120829003Battery · not seatedCEILING EMERGENCY LIGHTS FROM ROWS 28 TO 30 INOPERATIVE. RESET EMERGENCY LIGHT BATTERY. OPS CHECK NORMAL.Aug 28, 2012 · N7508 · Doug DC982 · Emergency LightingSDR AALA20120829002Battery · not seatedCEILING EMERGENCY LIGHTS FROM ROWS 13 TO 16 INOPERATIVE. RESEATED EMERGENCY LIGHT BATTERY (MID). OPS CHECK NORMAL.Aug 28, 2012 · N7508 · Doug DC982 · Emergency LightingSDR AALA20120829001Battery Pack · dischargedCEILING EMERGENCY LIGHTS FROM ROWS 3 TO 6. REMOVED AND REPLACED BATTERY PACK. OPS CHECK NORMAL.Aug 28, 2012 · N7508 · Doug DC982 · Emergency LightingSDR AALA20110719LGA01Battery Pack · dischargedEMERGENCY EXIT LIGHTS IN COCKPIT, BOTH FORWARD DOORS AND 1ST ROW INOPERATIVE. REPLACED FORWARD OVERHEAD BATTERY PACK. OPS CHECK NORMAL.Jul 19, 2011 · N7508 · Doug DC982 · Emergency LightingSDR AALA20110711TUL08Battery · not seatedTAIL CONE EMERGENCY LIGHTS INOPERATIVE. RESEATED BATTERIES FOR EMERGENCY LIGHTS AT TAIL CONE EMERGENCY LIGHTS. OPS CHECK NORMAL.Jul 8, 2011 · N7508 · Doug DC982 · Emergency LightingSDR AALA20110711TUL07Terminal · looseRIGHT AFT OVERWING EXIT SIGN INOPERATIVE. SECURED LOOSE TERMINAL AT RIGHT AFT OVERWING EXIT SIGN. OPS CHECK NORMAL.Jul 8, 2011 · N7508 · Doug DC982 · Light System WiringSDR AALA20110709LGA01Power Supply · inoperativeSEVERAL EMERGENCY LIGHTS AT ROWS 18 TO 21 INOPERATIVE. CLEANED POWER SUPPLY CONTACTS FOR ROWS 18 TO 21 EMERGENCY LIGHTS. OPS CHECK NORMAL.Jul 8, 2011 · N7508 · Doug DC982 · Emergency LightingSDR AALA20100817TUL09Fitting · corrodedCORROSION ON RIGHT WHEEL WELL FITTING. REMOVED CORROSION AND INSTALLED STRAP REPAIR PER EA MD80.53.012501.Aug 17, 2010 · N7508 · Doug DC982 · Fuselage Miscellaneous StructureSDR AALA20090702LGA07Light · inoperativeFORWARD PORTABLE EMERGENCY LIGHT INOPERATIVE. REMOVED AND REPLACED FORWARD PORTABLE EMERGENCY FLASHLIGHT PER MM, OPS CHECK OK.Jul 1, 2009 · N7508 · Doug DC982 · Emergency LightingSDR AALA20090702LGA06Battery Pack · dischargedEMERGENCY LIGHT AT FORWARD LOWER EMERGENCY OVERWING DOOR INOPERATIVE. REPLACED BOTH BATTERY PACKS AT BIN 20, OPS NORMAL.Jul 1, 2009 · N7508 · Doug DC982 · Emergency LightingSDR AALA20090702LGA05Battery · dischargedEMERGENCY LIGHT AT FORWARD LOWER EMERGENCY OVERWING DOOR INOPERATIVE. REPLACED BOTH BATTERY PACKS AT BIN 20, OPS NORMAL.Jul 1, 2009 · N7508 · Doug DC982 · Emergency LightingSDR AALA20090702LGA04Battery · not seatedEMERGENCY LIGHTS OVER RIGHT AFT EMERGENCY DOOR INOPERATIVE. RESEATED BATTERY AT ROW 19 AND 20, OPS NORMAL.Jul 1, 2009 · N7508 · Doug DC982 · Emergency LightingSDR AALA20090702LGA03Battery Pack · not seatedEMERGENCY LIGHTS IN AFT GALLEY CEILING AREA INOPERATIVE. RESEATED BATTERY PACK AT ROW 27, OPS NORMAL.Jul 1, 2009 · N7508 · Doug DC982 · Emergency LightingSDR AALA20090702LGA02Battery Pack · not seatedEMERGENCY LIGHTS IN AFT CABIN AND TWIL COMPARTMENT INOPERATIVE. RESEATED BOTH BATTERY PACKS IN CEILING OF AFT RIGHT LAVATORY, OPS NORMAL.Jul 1, 2009 · N7508 · Doug DC982 · Emergency LightingSDR AALA20090702LGA01Battery Pack · dischargedEMERGENCY LIGHTS IN FORWARD CABIN AND COCKPIT INOPERATIVE. REPLACED BATTERY PACK IN FORWARD CEILING, OPS NORMAL.Jul 1, 2009 · N7508 · Doug DC982 · Emergency LightingSDR AALA2009041100759Battery Pack · unsecureLGA - TAIL COMPARTMENT EMERGENCY LIGHTS INOPERATIVE. SECURED TAIL COMPARTMENT EMERGENCY BATTERY PACK.Apr 11, 2009 · N7508 · Doug DC982 · Emergency LightingSDR AALA2009032100620Light · missingTPA CLEAR EMERGENCY PATH LIGHT AT SEAT 19D MISSING LAMP. REPLACED LAMP FOR CLEAR EMERGENCY PATH LIGHT AT SEAT 19D.Mar 21, 2009 · N7508 · Doug DC982 · Emergency LightingSDR AALA2009032100619Lens · missingTPA CLEAR EMERGENCY PATH LIGHT AT SEAT 19D MISSING LENS. REPLACED LENS FOR CLEAR EMERGENCY PATH LIGHT AT SEAT 19D.Mar 21, 2009 · N7508 · Doug DC982 · Emergency LightingSDR AALA2009012900396Battery Pack · dischargedLGA - EMERGENCY LIGHTS AT FORWARD GALLEY AREA INOPERATIVE. REPLACED BATTERY PACK AT FORWARD GALLEY AREA.Jan 29, 2009 · N7508 · Doug DC982 · Emergency LightingSDR AALA2009012900395Battery Pack · dischargedLGA - EMERGENCY LIGHTS INOPERATIVE. REPLACED BATTERY PACK.Jan 29, 2009 · N7508 · Doug DC982 · Emergency LightingSDR AALA200810552Floor Support · corrodedCORROSION ON AFT END OF FLOORBOARD SUPPORT ON RT SIDE.(AFT CARGO) INSTALLED A SERVICEABLE SUPPORT IAW SRM 51-10-1.Dec 6, 2008 · N7508 · Doug DC982 · Fuselage Miscellaneous StructureSDR AALA200802572ACsd · failedMSY INFLIGHT DFW TO TPA. CREW REPORTED RIGHT HAND CONSTANT SPEED DRIVE LOW PRESSURE INDICATION. APU WOULD NOT START. DIVERTED TO MSY AND LANDED WITHOUT INCIDENT. REPLACED CONSTANT SPEED DRIVE. SYSTEM GROUND CHECKED NORMAL OPERATION. (CLOSED)Nov 23, 2008 · N7508 · Doug DC982 · Airborne Auxiliary Power Unit (APU) System
Back to N7508, cancelled Aug 31, 2015