N795FT, cancelled Oct 5, 2005
Service difficulty reports · 205
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N795FT' AND deregistration_id = 'N795FT-2005-10-05' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N795FT' AND deregistration_id = 'N795FT-2005-10-05' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR RRXA010050Transmitter · failedREJECTED T/O AT DAY, GREATER 60 KTS, NR 2 OIL PRESSURE GAUGE SHOWED AT LEAST 15 PSI HIGHER THAN OTHERS, AND APPEARED TO CONTINUE TO CLIMB. REMOVED AND REPLACED NR 2 ENGINE OIL PRESSURE TRANSMITTER IAW M/M 79-32-1. OPS CHECKS GOOD IAW M/M 71-00-00.SDR RRXA010012Control Cable · defectiveON TAXI OUT LOST NOSE STEERING AIRCRAFT WAS TOWED BACK TO EMERGENCY RAMP BY AIRPORT DELTA SUPER TUG. GEAR PIN INSTALLED. REMOVED AND REPLACED RIGHT SIDE NOSE STEERING CABLE IAW DC-8 M/M 22-51-0. OPS CHECK GOOD.SDR RRXA003602Panel · delaminatedDURING A MAINTENANCE VISIT FOUND DELAMINATION DAMAGE TO THE L/H WING BOTTOM T/E PANEL AT STA XRS 419 TO XRS 435, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. RECEIVED PART AND INSTALLESDR RRXA010006Engine · fodON WALK-AROUND FOUND FOD ON NR 3 ENGINE.SDR RRXA010034Mechanism · out of adjAFTER T/O ACFT DIDN'T GROUND SHIFT; COULD NOT RETRACT MLG. ADJUSTED NOSE GEAR GROUND SHIFT MECHANISM IAW DC-8 M/M CH 32-23-01, OP CHKS GOOD.SDR RRXA003799Fitting · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO LT.WW BATHTUB FITTING AT STA. 960 AND L24L FWD SIDE, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. RECEIVED PART AND INSTALLED IAW DSDR RRXA003592Fitting · crackedDURING A MAINTENANCE VISIT FOUND A CRACK TO THE RT WING #1 GROUND SPOILER O/B MOUNT FITTING, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. RECEIVED PART AND INSTALLED IAW DC-8 SRM 51-1-SDR RRXA003591Panel · delaminatedDURING A MAINTENANCE VISIT FOUND DELAMINATION DAMAGE TO THE R/H WING BOTTOM T/E PANEL AT STA XRS 340 TO XRS 419, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. RECEIVED PART AND INSTALLESDR RRXA003595Track · crackedDURING A MAINTENANCE VISIT FOUND A CRACK TO THE "D-PIT" DOOR AFT TRACK (3" CRACK), DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. RECEIVED PART AND INSTALLED IAW DC-8 SRM 51-1-21.SDR RRXA003594Longeron · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE UNDER RT LONGERON 24 SUPPORT FITTING AT STA 920 RT W/W Y-920 X-66, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATD REPAIR AND INSTALLED IAW EO 00-316 WITH SDR RRXA003593Fitting · crackedDURING A MAINTENANCE VISIT FOUND A CRACK TO THE #1 GND SPOILER I/B MOUNT FITTING, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8.RECEIVED PART AND INSTALLED IAW DC-8 SRM 51-1-21 & 51-1-20SDR RRXA003596Fastener · missingDURING A MAINTENANCE VISIT FOUND MISSING FASTENER ON THE RT UPPER WING THRU ACCESS HOLE 505C & THROUGH MID SPAR ACCESS HOLE 560C INSIDE TANK I/B BETWEEN STA 252 & 255, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8.SDR RRXA003603Longeron · crackedDURING A MAINTENANCE VISIT FOUND A CRACK TO THE TOP ON LONGERON JUST FWD OF 'C' PIT DOOR AT STA 1140 AND L33R, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. RECEIVED PART AND INSTALLED SDR RRXA003601Panel · delaminatedDURING A MAINTENANCE VISIT FOUND DELAMINATION DAMAGE TO THE R/H WING BOTTOM T/E PANEL AT STA XRS 5 TO XRS 98, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. RECEIVED PART AND INSTALLED ISDR RRXA003599Door · delaminatedDURING A MAINTENANC EVISIT FOUND DELAMINATION IN 2 PLACES ON THE LEFT MLG TOP DOOR TO WING, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. RECEIVED PART AND INSTALLED IAW DC-8 SRM 51-3-0SDR RRXA003598Angle · crackedDURING A MAINTENANCE VISIT FOUND THE BULKHEAD ATTACH ANGLE BROKEN AND CRACKED ON THE AFT LWR CARGO COMPT AT STA 1320 X35 Z-8, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED RESDR RRXA003597Skin · crackedDURING A MAINTENANCE VISIT FOUND A CRACK TO THE AFT LWR CORNER OF THE "D" PIT DOOR, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8.FABRICATED REPAIR AND INSTALLED IAW DC-8 SRM 52-2-0 FIG.SDR RRXA003608Web · chafedDURING A MAINTENANCE VISIT FOUND A CHAFFED WEB IN COCKPIT BETWEEN FRAMES -52 & -67, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED REPAIR AND INSTALLED IAW DC-8 SRM 53-2-0 & 51-1-21.SDR RRXA003607Panel · delaminatedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE COCKPIT FLOOR PANEL CAPT'S SIDE, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED PART AND INSTALLED IAW DC-8 SRM 51-1-2SDR RRXA003605Pressure Panel · corrodedDURING A MAINTENANCE VISIT FOUND 21 SHEAR RIVETS ON THE FINGER DOUBLER AT THE COCKPIT AREA FLOOR BELOW AFT END OF CAPT'S CHAIR, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED REPAIR AND INSTALLED IAW DC-SDR RRXA003604Floor Panel · brokenDURING A MAINTENANCE VISIT FOUND ELONGATED SCREW HOLES BROKEN OUT ON THE FLOOR PANEL 681, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED PART AND INSTALLED IAW DC-8 SRM 51-1-4SDR RRXA003606Skin · puncturedDURING A MAINTENANCE VISIT FOUND A PUNCTURE HOLE IN THE OUTER SKIN ON THE FUSELAGE AT STA 220 TO 240 AND L25L, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED REPAIR AND INSTALLED IAW DC-8 SRM 51-1-20D & SDR RRXA003800Skin · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION/SHEARED RIVITS DAMAGE TO DOUBLER AT STA. 1697 AND L29L, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED REPAIR AND INSTALLED IAW EO#0SDR RRXA003612Skin · crackedDURING A MAINTENANCE VISIT FOUND A CRACK TO THE MOST O/B HOLE ON THE R/H WING LWR SKIN AT STR 64, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED REPAIR AND INSTALLED IAW DC-8 SDR RRXA003611Fitting · crackedDURING A MAINTENANCE VISIT FOUND A CRACK TO THE BATHRUB FITTING BETWEEN STA 1690 & 1700 AND L34L, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. RECEIVED PART AND INSTALLED IAW DC-8 SRM SDR RRXA003610Fitting · crackedDURING A MAINTENANCE VISIT FOUND A CRACK TO THE FLOOR STRUT FITTING AFT LWR CARGO COMPT AT STA 1160 AND L27R, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. RECEIVED PART AND INSTALLED ISDR RRXA003609Flange · crackedDURING A MAINTENANCE VISIT FOUND A CRACK TO THE FLOOR BEAM R/H O/B LWR LEG ON FWD SIDE AT STA 920, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED REPAIR AND INSTALLED IAW EO#0SDR RRXA003502Intercostal · crackedDURING A MAINTENANCE VISIT FOUND A CRACK TO THE INTERCOSTAL W/W AT STA 940 AND WING STA 69.5 RT W/W, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.SDR RRXA003506Skin · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION BLISTERS ON THE SKIN AT STA 1714 AND L29L, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.SDR RRXA003505Structure · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE REPAIR PATCH RIVETS ON COCKPIT SUB-FLOOR FWD OF L/H AVIONICS RACK, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////OPEN/////SDR RRXA003504Fitting · crackedDURING A MAINTENANCE VISIT FOUND A CRACK TO THE ANGLE SUPPORT FITTING AT STA 960 R/H, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.SDR RRXA003503Web · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE ON WEB ABOVE RT LONGERON 24Y AT STA 879 X=-59 Z=10 INCH, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.SDR RRXA003507Skin · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE "D-PIT" DOOR BOTTOM AFT CORNER, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.SDR RRXA003513Sill · crackedDURING A MAINTENANCE VISIT FOUND A CRACK TO THE REPAIR AFT SIDE OF "C-PIT" DOOR SILL, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////OPEN/////SDR RRXA003512Frame · brokenDURING A MAINTENANCE VISIT FOUND THE AFT SIDE FWD FRAME BROKEN OFF "C-PIT" DOOR SILL, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.SDR RRXA003511Sill · crackedDURING A MAINTENANCE VISIT FOUND A CRACK TO THE "C-PIT" DOOR SILL REPAIR, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.SDR RRXA003510Web · crackedDURING A MAINTENANCE VISIT FOUND A CRACK IN WEB AT RT. CUSP AT STA 1300 Y=1300 X-66 Z-0, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.SDR RRXA003509Floor Panel · damagedDURING A MAINTENANCE VISIT FOUND TORN OUT SCREW HOLES ON THE COCKPIT FLOOR PANEL BETWEEN PILOT & CO-PILOTS SEAT, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.SDR RRXA003508Web · tornDURING A MAINTENANCE VISIT FOUND A TORN STRUCTURE ON 'A' PIT DOOR INTERNAL WEB, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.SDR RRXA003518Track · crackedDURING A MAINTENANCE VISIT FOUND A CRACK TO THE "C-PIT" DOOR DOOR COVER AT TRACK, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.SDR RRXA003517Floor Panel · crackedDURING A MAINTENANCE VISIT FOUND A CRACK AND TORN OUT SCREW HOLES ON THE COCKPIT FLOOR PANEL PILOTS SEAT, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.SDR RRXA003516Floor Panel · crackedDURING A MAINTENANCE VISIT FOUND A CRACK TO THE FLOOR PANEL 678, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.SDR RRXA003515Skin · crackedDURING A MAINTENANCE VISIT FOUND 2 CRACKS ALONG BOTTOM OF MAIN CARGO DOOR, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.SDR RRXA003514Fitting · crackedDURING A MAINTENANCE VISIT FOUND A CRACK TO THE RT LONGERON 24 SUPPORT FITTING FWD EDGE AT STA 902, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////OPEN/////SDR RRXA003806Door Frame · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO A-PIT DOOR FRAME AT STA. 300, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8.FABRICATED REPAIR AND INSTALLED IAW DC-8 SRM 53-2-0 & 51-1-21.SDR RRXA003522Threshold · crackedDURING A MAINTENANCE VISIT FOUND A CRACK AND DENTED EDGES TO THE "D-PIT" THRESHOLD/KICK PLATE, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////OPEN/////SDR RRXA003521Doubler · crackedDURING A MAINTENANCE VISIT FOUND 'C-PIT' DOOR HAS REPAIR CRACKING OFF, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.SDR RRXA003520Bulkhead · damagedDURING A MAINTENANCE VISIT FOUND GILLINER ATTACH ANGLE & BULKHEAD ATTACH HOLES BROKEN OUT ON THE AFT LWR CARGO BILGE AT STA 1320 AND L31L TO L31R, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.SDR RRXA003519Frame · crackedDURING A MAINTENANCE VISIT FOUND A CRACK TO THE "C-PIT" DOOR FWD FRAME (DOOR COVER), DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.SDR RRXA003529Bracket · wornDURING A MAINTENANCE VISIT FOUND A WORN "T-BOLT" RETAINING BRACKET (TOP SIDE) NR 5 BOTTOM, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.