N805WP, cancelled Mar 4, 2023
Service difficulty reports · 45
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N805WP' AND deregistration_id = 'N805WP-2023-03-04' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N805WP' AND deregistration_id = 'N805WP-2023-03-04' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR KPVA2013031201Repair · crackedDURING A SCHEDULED MAINTENANCE INSPECTION IN THE NOSE WHEEL AREA, A CRACK WAS DISCOVERED ON AN EXISTING REPAIR ANGLE "B" AT STA X97.00. INFORMATION SENT TO BOMBARDIER ALONG WITH A REQUEST FOR TEMPORARY CONTINUED OPERATION FOR A MAXIMUM OF 50HRS IN ORDER TO PESDR KPVA201206Strap · crackedCRACK STRAPS (PN: 85711250 & PN: 85711248) ON STR 15 ON THE RT LOWER WING SKIN PANEL BTW YW189.9-YW207.0. REPAIRED PER BOMBARDIER RD 8-57-5485.SDR KPVA 201110Turbine Blades · draggingLT PROP NOT SPINNING FREELY. MAINTENANCE BORESCOPED THE 1ST STAGE POWER TURBINE (PT) AND DISCOVERED THE PT BLADES RUBBING AT LOWER BLADE ROOTS CAUSING THEM TO WEAR TO AN UNSERVICEABLE CONDITION.SDR KPVA20110816001Strap · crackedLT WING STRINGER 14 AT STA YW 196 STRAP PN 85711248 CRACKED.SDR KPVA 201108Strap · crackedLT WING STRINGER 14 AT STATION YW 196 STRAP PN 85711250 IS CRACKED.SDR KPVA 2010 02Propeller · overspeedWHILE DEPARTING RUNWAY 05 FROM MKK EXPERIENCED OVERSPEED ON NR 2 PROPELLER ON CLIMBOUT. COMPLETED APPLICABLE CHECK LISTS, DECLARED AN EMERGENCY WITH MKK TOWER AND RETURNED TO RUNWAY 05 FOR LANDING AND CANCELLED THE EMERGENCY THEN CONTACTED DISPATCH.SDR KPVA 2009-03Warning System · false activationPIREP - ON TAKEOFF ROLL; ROLL SPOILER INBOARD GROUND, ROLL SPOILER OUTBOARD GROUND CAUTION LIGHTS ILLUMINATED. MX PERFORMED OPERATIONAL TEST ROLL SPOILER SYSTEM IAW DHC-8 MM 27-14-00 PG 204-205. COULD NOT DUPLICATE. NO DEFECTS NOTED.SDR KPVA200718Tire · flat(PIREP) UPON DEPARTURE IN JHM, VIOLENT SHAKING FROM NOSE. TAXI CLEAR, REALIZED 2 NOSEWHEEL TIRES FLAT. (MX) REMOVED AND REPLACED NLG WHEEL ASSY NR 1 & 2 IAW DHC-8 MM 32-41-16 PG 201-205. (1) P/N 3-1448 S/N 1323 (2) P/N 3-1448 S/N 2401. INSPECTION OF TIRES SDR KPVA200621Engine · smokeSMOKE IN COCKPIT AND CABIN IN FLIGHT. (MX) MAINT DETERMINED THE CAUSE WAS FROM ENGINE BLEEDS AND AUTHORIZED A FERRY FLIGHT WITH BLEEDS OFF, BACK FOR MAINTENANCE. THE FINDINGS WERE THAT THE SMOKE/FUMES WAS FROM THE NR 2 ENGINE. MAINT REPLACED THE NR 2 ENGINE.SDR 20069Warning Light · low pressure(PIREP) NR 1 ENGINE OIL PRESSURE WARNING LIGHT ILLUMINATED DURING CLIMBOUT. GAUGE INDICATED LESS THAN 20 PSI WHILE IN FLIGHT. AFTER ABOUT 1 MINUTE, GAUGE STARTED FLUCTUATING RAPIDLY. AFTER ADDITIONAL 1 MINUTE, GAUGE READINGS RETURNED TO NORMAL.MECHANIC FOUND SDR KPVA20065Skin · ground damageCOMMISSARY CART HIT AIRCRAFT, MADE A 4 INCH HOLE NEAR THE EXTERNAL POWER RECEPTACLE. REPAIRED FWD PUNCTURE AT STA X136.8 - X151.6 BETWEEN STRINGERS 24P AND 26P IAW BOMBARDIER REPAIR DRAWING 8-53-8934. REPAIRED AFT PUNCTURE AT STA X182.00 - X201.15 BETWEEN STSDR 200514Smoke Detector · intermittent(MX) SMOKE AND MASTER WARNING LIGHTS INTERMITTENT DURING TEST OF NR 2 BAGGAGE SMOKE DETECTOR. REMOVED AND REPLACED NR 2 BAGGAGE SMOKE DETECTOR. INSTALLED CONNECTOR AND SECURED WITH 4 MOUNTING SCREWS. OPS CHECK GOOD IAW DHC-8 MM 26-12-00, PG 201.SDR KPV2005F00002Pcu · failedDURING TAXI OUT NR 1 BETA LIGHT CAME ON WITH THE POWER LEVERS ABOVE FLIGHT IDLE. RETURNED TO GATE. REPLACED NR1 PCU, OPERATIONALLY CHECKS GOOD. (K)SDR 200510Indicator · stuckON TAKEOFF, NR 2 TQ GAUGE STUCK AT 68 PERCENT TQ INDICATION ON BOTH ANALOG AND DIGITAL INDICATIONS. GAUGE STUCK EVEN AFTER ENGINE SHUT DOWN. PERFORMED POWER RUN AND OPS CHECK OF TORQUE INDICATION SYSTEM IAW DHC PSM 1-8-2, 77-10-00 PG 2-3. OPS CHECK GOOD.SDR 20058Line · leakingNR 2 HYD SYSTEM LEAK. NR 2 HYD AND NR 2 ENG HYD PUMP LIGHTS ILLUMINATED. FOUND A LEAK IN NLG WHEEL WELL BEHIND THE DEBRIS GUARD ON LINE (P/N 82910010-207) WHICH EMPTIED NR 2 HYD RES. INSTALLED A TEMP LINE IAW DHC -8 MM CH 20-06-03 PG 6 & SERVICED NR 2 HYD RSDR 20051Packing · cutNR 1 HYD SYSTEM FAILURE (ISO VALVE). CAUTION PANEL DID NOT HAVE NR 1 ISO VALVE CAUTION LIGHT, ONLY A LINE. EMERGENCY LANDING OGG. ENGINE SHUT DOWN ON RUNWAY. INSPECTED NR 1 HYD SYSTEM FOR LEAKS AND FOUND LT OUTER WING FITTING REDUCER PACKING RIPPED. REMOVSDR 200412Engine · fodNR 1 ENGINE PCE 120692, LP IMPELLER FOD DAMAGED BEYOND LIMITS (ENGINE CHANGE). REMOVED AND REPLACED NR 1 ENGINE WITH PCE 120107 IAW FORM AIAM-105. PERFORMANCE ENGINE RUN UP IAW DHC 8 PSM 1-8-2, 71-00-00 MM PG 529-544 SEC 3 TABLE 505.SDR 200411Engine · malfunctioned(PIREP) JUST AS THE GEAR FULLY RETRACTED, THE NR 1 ENGINE TORQUE DROPPED 10 PERCENT, ACCOMPANIED BY A LOW HUMMING NOISE. ALL OTHER INDICATIONS NORMAL, NOISE CEASED AFTER LANDING.MECHANIC PERFORMED ENGINE MAINTENANCE RUN IAW MM 72-00-00 PG. 201. NO DEFECTS NSDR KPVA200338Power Supply · inoperativeHNL - RIGHT AFT EGRESS LIGHT INOPERATIVE. REMOVED AND REPLACED EMERGENCY LIGHT BATTERY AT 3351-PS4 IAW DHC-8 CMM CHAP 33-50-67. OPS CHECK GOOD IAW DHC-8 CHAP 33-51-00 PAGE 201-202. (M)SDR KPVA200329Power Supply · inoperativeEMERGENCY LIGHTS INOPERATIVE, PS2. REMOVED AND REPLACED POWER SUPPLY PS2 IAW DHC MM 33-51-00 PAGE 201-22 SECT 1A. OPS CHECK GOOD IAW DHC MM 33-51-00 PAGE 201-202 SECT 2A. (M)SDR KPVA200327Battery Pack · weakPORTABLE EMERGENCY EXIT LIGHT BATTERY WEAK. REMOVED AND REPLACED PORTABLE EMERGENCY LIGHT. OPS CHECK GOOD IAW DHC 8 MM 33-51-00 PAGE 201-202. NO DEFECTS NOTED. (M)SDR 2003F00355Smoke Detector · malfunctionedSMOKE WARNING LIGHT ON WHILE ON GROUND. TROUBLESHOT SYSTEM, FOUND TOP SMOKE DETECTOR TO BE FAULTY. DISCONNECTED CONNECTOR AND SECURED. DEFERRED PER MEL 26-8-1. PLACARD INSTALLED. CAT C 5/9/03, DUE 5/19/03. CLEARED MEL 26-8-1 SMOKE WARNING LIGHT ON BAGGAGSDR KPVA200315Light · malfunctionedFOUND COCKPIT PORT EMERGENCY LIGHT DIM. REMOVED AND REPLACED LIGHT. (M)SDR 2003F00378Light · malfunctionedPORTABLE EMERGENCY LIGHT DIM. REMOVED PORTABLE EMERGENCY LIGHT AND RE-INSTALLED SERVICEABLE PORTABLE EMERGENCY LIGHT BY RESECURING INTO LOCKING SOCKET. (M)SDR 2003F00377Boot · separatedFOUND LEFT LEADING EDGE DE-ICE BOOT SEPARATED FROM LEADING EDGE. RE-SEALED LEFT LEADING EDGE 513BL DE-ICE BOOT IAW MM 30-10-46 PAGE 225-230. (M)SDR 2003F00376Wheel · wornNR 4 MLG WHEEL ASSEMBLY WORN. REMOVED AND REPLACED NR 4 MAIN WHEEL ASSEMBLY IAW DHC8MM 32-41-11 PAGE 201-205. COMPLIED WITH MM INSPECTION AND NO DEFECTS NOTED. (M)SDR 2003F00374Boot · corrodedDE-ICE BOOT LEADING EDGE 513BL SURFACE CORROSION ALONG TRAILING EDGE TOP AND BOTTOM, LEFT SIDE. REMOVED SURFACE CORROSION AND TREATED. APPLIED PAINT, COATING IAW 8 MM 30-10-46 PAGE 231. (M)SDR KPVA200313Signal Cond Unit · malfunctionedHNL - FLT 1550 - DURING AND AFTER TAKEOFF, AUTO FEATHER DE-SELECTED BUT ARM LIGHT STILL ILLUMINATED. WHEN POWER REDUCED BELOW 80 PERCENT ARM LIGHT OUT, ABOVE 80 PERCENT ARMED LIGHT ON AGAIN. REMOVED AND REPLACED NR 1 ENGINE TORQUE SIGNAL CONDITION UNIT IAW PSDR KPVA200311Light · inoperativeCOCKPIT PORTABLE EMERGENCY LIGHT DIM. REMOVED AND REPLACED PORT EMERGENCY EXIT LIGHT ASSEMBLY AND SECURED IN HOLDING ASSEMBLY AND LATCHED. OPS CHECKED GOOD IAW MM.SDR KPVA200310Battery · inoperativeCOCKPIT PORTABLE EMERGENCY LIGHT BATTERY WEAK. REMOVED AND REPLACED PORTABLE EMERGENCY LIGHT. OPERATIONAL CHECK OF SYSTEM GOOD. WORK IAW MM.SDR KPVA20036Battery · weakHNL - PORT EMERGENCY EXIT LIGHT BATTERY WEAK. REMOVED AND REPLACED PORT EMERGENCY EXIT LIGHT. OPS CHECK GOOD IAW DHC-8 MM 33-51-00 PAGE 201-202. NO DEFECTS NOTED. (M)SDR KPVA20034Battery Pack · inoperativeRIGHT FORWARD EMERGENCY EGRESS LIGHT, RIGHT FORWARD EMERGENCY DOOR EXIT LIGHT AND FORWARD 2ND CEILING EMERGENCY LIGHT INOPERATIVE DURING OP CHECK OF EMERGENCY LIGHT CHECK. REMOVED AND REPLACED EMERGENCY LIGHT BATTERY PACK 3351PS2 IAW DHC-8 MM CHAPTER 33-51-00SDR KPVA200243Lens · dislodgedEXIT SIGN FELL OFF. RESECURED EXIT SIGN OVER GALLEY BY PUSHING INTO POSITION. SECURITY CHECK OF INSTALLATION GOOD.SDR KPVA200242Light · looseEMERGENCY EXIT LIGHT/SIGN BY SEAT 1E, LOOSE. C/A: REMOVED AND REPLACED EMERGENCY EXIT LIGHT/SIGN IAW MM. OPS CHECK GOOD IAW MM.SDR 2003F00158Blade · crackedFOUND CRACK ON NR 1 BLADE OF NR 2 ENGNE PROP ASSEMBLY. REMOVED NR 1 BLADE OF NR 2 ENGINE PROP ASSEMBLY IAW HAMILTON SUNDSTRAND MM 61-10-00, PATE 307-311 PARA 5A. INSTALLED NEW PROP BLADE IAW HAMILTON SUNSTRAND MM 61-10-00, PAGE 705-714 PAR, G/H. GROUND RUN-SDR KPVA200236Blade · crackedMAINTENANCE FOUND CRACK ON NR 1 BLADE OF NR 2 ENGINE PROP ASSY. REMOVED NR 1 BLADE OF NR 2 ENGINE PROP ASSY IAW HAMILTON SUNDSTRAND MM 61-10-00, PAGE 307-311 PARA 5A. INSTALLED NEW PROP BLADE IAW HAMILTON SUNSTRAND MM 61-10-00, PAGE 705-714 PAR, G/H. GROUNDSDR KPVA200235Circuit Card · faultyHNL - FLT 1139 - EMERGENCY LIGHTS COME ON WHEN SELECTED TO OFF POSITION AND STAY ON. ATTEMPTED TO RECYCLED SAME RESULTS. THE ONLY WAY TO TURN THEM OFF IS IN THE ARM POSITION. REMOVED AND REPLACED CIRCUIT CARD IN EMERGENCY LIGHTS CONTROL BOX IAW DHC-8 WIRINGSDR KPVA200225Light · inoperativePORTABLE EMERGENCY LIGHT ABOVE COCKPIT DOOR INOPERATIVE. REMOVED AND REPLACED PORTABLE EMERGENCY LIGHT ABOVE COCKPIT DOOR. OPS CHECK GOOD IAW DHC MM 33-51-00 PAGE 201-202. NO DEFECTS NOTED. (M)SDR KPV2002F00003Control Cable · frayedNOSE WHEEL ALT EXTENSION CABLE FRAYED. REMOVED AND REPLACED NOSE WHEEL ALT EXTENSION HANDLE CABLE, RIGGED NLG ALT EXTENSION RELEASE CONTROL IAW DHC 8 MM. OPS CHECK GOOD IAW DHC8 MM.SDR KPVA200116Control Box · failedHNL - FLT 1639 - EMERGENCY LIGHTS WILL NOT TURN OFF EXCEPT IN 'ARMED' POSITION WITH BATTERY POWER ON. TROUBLE SHOT SYSTEM AND DETERMINED THE SYSTEM CONTROL BOX FAILED. REMOVED AND REPLACED EMERGENCY LIGHTS CONTROL BOX, OPERATIONAL CHCK OF SYSTEM COMPLIED WITSDR 20001122SH005Battery · inoperativeHNL - OVERHEAD EMERGENCY EXIT LIGHT INOPERATIVE AT ROW 4. REMOVED AND REPLACED EMERGENCY LIGHT POWER SUPPLY 3351 PS4 AT AFFECTED POSITIONS. SYSTEMS OPS CHECKED GOOD. WORK PERFORMED IAW AMM 35-51-00, PAGES 201 AND 202. (X)SDR KPVA200026Battery · dischargedHNL - EMERGENCY LIGHT BATTERIES INOPERATIVE AT POSITIONS 2 AND 4, S/N 1351 AND 1998. REMOVED AND REPLACED BATTERY PACK AND AFFECTED POSITIONS. SYSTEMS OPS CHECKED GOOD. WORK PERFORMED IAW AMM 33-51-00, PAGES 201 AND 202. (M)SDR 99ZZZM369Sensor · out of adjustHNL - FLT 1552 - CLIMBING THROUGH 6500-7500 FT, THE AIRCRAFT WAS PRESSURIZED, THE MASTER WARNING LIGHT ILLUMINATED CONCURRENTLY WITH THE 'PASS DOOR' WARNING LIGHT. NOTIFIED ATC AND DECLARED AN EMERGENCY, RETURNED HNL TO LAND. INSPECTED AFFECTED SYSTEM AND DESDR 99ZZZM35Battery · dischargedHNL - DISCREPANCY FOUND DURING MAINTENANCE DAILY INSPECTION, CABIN EMERGENCY LIGHTS DID NOT TEST. REMOVED AND REPLACED EMERGENCY BATTERIES.SDR 99ZZZX153Light · malfunctionedHNL - DURING PRE-FLIGHT INSPECTION ACCOMPLISHED BY THE FLIGHT CREW, THE PORTABLE EMERGENCY LIGHTS WOULD NOT EXTINGUISH WITH THE EMERGENCY LIGHT SWITCH LOCATED IN THE COCKPIT.