N812HK, cancelled May 7, 2019

Service difficulty reports · 128

Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.

Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy
  FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet'
  WHERE n_number = 'N812HK' AND deregistration_id = 'N812HK-2019-05-07'
  ORDER BY difficulty_date DESC"

Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.

SDR RAIA201707170002Fitting · crackedLEFT ENGINE FWD PYLON YOKE LOWER LINKAGE FITTING HAS A CRACK INDICATION. CONFIRMED CRACKED. REMOVED AND REPLACED THE LT ENGINE FWD PYLON YOKE LINKAGE FITTING.Jul 17, 2017 · N812HK · Emb EMB145LR · Engine Mount SectionSDR RAIA201707160001Linkage · crackedRIGHT ENGINE FWD PYLON YOKE LOWER FWD LINKAGE FITTING HAS CRACK INDICATION. PERFORMED NDT, CONFIRMED CRACK. REMOVED AND REPLACED RT FWD YOKE LINKAGE FITTING.Jul 16, 2017 · N812HK · Emb EMB145LR · Nacelle/Pylon, Frame/Spar/RibSDR RAIA201702080001Outflow Valve · malfunctionedAUTO AND MANUAL PRESSURIZATION MODES INOPERATIVE. PRESSURIZATION GOES UP AND DOWN ON ITS OWN WITH ALTITUDE. R & R AUTO OUTFLOW VALVE OPS CHECKED GOOD, R & R GROUND CONNECTION VALVE PERFORMED PRESSURIZATION CHECK. OPS CHECKED GOOD. NO DEFECTS NOTEDFeb 8, 2017 · N812HK · Emb EMB145LR · Pressure Regulator/Outflow ValveSDR RAIA201608010001Pressure Switch · failedRUDDER 1 INOPERATIVE IN FLIGHT. R & R RUDDER NR 1 AND NR 2 SYS PRESSURE SWITCHES. OPS CHECK GOOD.Aug 1, 2016 · N812HK · Emb EMB145LR · Rudder Control SystemSDR RAIA201606100002Condenser · crackedON FINAL APPROACH SMELL OF SMOKE ORIGINATING IN CABIN NO VISUAL. INSPECTED FOUND CRACKED CONDENSER/MIXER. R & R CONDENSER/MIXER. OPS CHECK GOODJun 6, 2016 · N812HK · Emb EMB145LR · Cabin Cooling SystemSDR RAIA201605020002Flashlight · inoperativeF/O FLASHLIGHT WILL NOT HOLD CHARGE. R & R F/O'S FLASHLIGHT ASSY. OPS CHECK GOOD.May 2, 2016 · N812HK · Emb EMB145LR · Emergency EquipmentSDR RAIA201510170001Connector · unsecureEMERGENCY EXIT AISLE FLOOD LIGHT IN CEILING AT ROW 3, LIGHT 16A, IS INOPERATIVE. TIGHTENED LOOSE CONNECTION ABOVE CEILING PANEL AT ROW 3. OPS CHECK OF EMERGENCY EXIT AISLE FLOOD LIGHT AT ROW 3 GOOD.Oct 17, 2015 · N812HK · Emb EMB145LR · Light System WiringSDR RAIA201508010001Sign · inoperativeEMERGENCY EXIT SIGN ABOVE SEATS 12BC, NR 22, IS INOPERATIVE. MAINTENANCE REPLACED EMERGENCY EXIT LIGHT, OPS CHECKED GOOD.Aug 1, 2015 · N812HK · Emb EMB145LR · Emergency LightingSDR RAIA201504050001Apu · overheatedAPU OVER HEAT FOLLOWED BY APU FAIL EICAS MSGS DURING CLIMB, RETURNED TO BLOCK.Apr 5, 2015 · N812HK · Emb EMB145LR · APU Core EngineSDR RAIA201501020004Bulb · inoperativeAISLE FLOOD LIGHT 16A INOPERATIVE. MAINTENANCE REPLACED THE BULB, OPS CHECKED GOOD.Jan 2, 2015 · N812HK · Emb EMB145LR · Emergency LightingSDR RAIA201501020003Bulb · inoperativeSERVICE DOOR EMERGENCY EXIT LIGHT INOPERATIVE. MAINTENANCE REPLACED BULB, OPS CHECKED GOOD.Jan 2, 2015 · N812HK · Emb EMB145LR · Emergency LightingSDR RAIA201412050001Bulb · inoperativeSERVICE DOOR LOWER EMERGENCY EXIT LIGHT IS INOPERATIVE. MAINTENANCE REPLACED SERVICE DOOR LOWER EMERGENCY EXIT LIGHT BULB, OPS CHECK GOOD.Dec 5, 2014 · N812HK · Emb EMB145LR · Emergency LightingSDR RAIA201409240001Placard · deterioratedRT EMERGENCY DOOR EXTERIOR EXIT AND PUSH TO OPEN PLACARDS FADED. MAINTENANCE REPLACED PLACARDS.Sep 24, 2014 · N812HK · Emb EMB145LR · Placards and MarkingsSDR RAIA201403160001Bulb · inoperativeCEILING EMERGENCY EXIT LIGHT AT ROW 17 INOPERATIVE. MAINTENANCE REPLACED BULB AND OPS CHECKED GOOD.Mar 16, 2014 · N812HK · Emb EMB145LR · Emergency LightingSDR RAIA201312050001Structure · corrodedPASSENGER DOOR HAS CORROSION. MAINTENANCE REPLACED CORRODED PARTS OF PASSENGER DOOR.Dec 5, 2013 · N812HK · Emb EMB145LR · Passenger/Crew DoorsSDR RAIA201311260006Structure · corrodedPASSENGER DOOR THRESHOLD U SHAPES CORRODED. MAINTENANCE REPLACED PASSENGER DOOR THRESHOLD U SHAPES.Nov 26, 2013 · N812HK · Emb EMB145LR · Fuselage Miscellaneous StructureSDR RAIA201311260007Channel · corrodedCARGO RAMP ZEE CHANNEL IS CORRODED. MAINTENANCE REPLACED CARGO RAMP CHANNEL.Nov 26, 2013 · N812HK · Emb EMB145LR · Fuselage Miscellaneous StructureSDR RAIA201311260009Floor Support · corrodedCENTER OMEGA BEAM AT FRAMES 22 & 23 CORRODED. MAINTENANCE REPLACED CENTER OMEGA BEAM.Nov 26, 2013 · N812HK · Emb EMB145LR · Fuselage Miscellaneous StructureSDR RAIA201311260008Structure · corrodedLAVATORY WASTE CUP IS CORRODED. MAINTENANCE REPLACED LAVATORY WASTE CUP.Nov 26, 2013 · N812HK · Emb EMB145LR · Fuselage Miscellaneous StructureSDR RAIA201311260005Floorbeam · corrodedCENTER FLOORBEAM HAS CORROSION. MAINTENANCE REPLACED CENTER FLOORBEAM.Nov 26, 2013 · N812HK · Emb EMB145LR · Fuselage Main, Floor BeamSDR RAIA201311260004Floor Support · corrodedRIGHT AFT FLOOR SUPPORT HAS CORROSION. MAITNENANCE REPLACED RT AFT FLOOR SUPPORT.Nov 26, 2013 · N812HK · Emb EMB145LR · Fuselage Miscellaneous StructureSDR RAIA201311260003Doubler · corrodedFWD FLOOR STRUCTURE DOUBLER HAS CORROSION. MAINTENANCE REPLACED FWD FLOOR STRUCTURE DOUBLER.Nov 26, 2013 · N812HK · Emb EMB145LR · Fuselage Miscellaneous StructureSDR RAIA201311260002Floor Support · corrodedRIGHT FWD FLOOR SUPPORT HAS CORROSION. MAINTENANCE REPLACED RT FWD FLOOR SUPPORT.Nov 26, 2013 · N812HK · Emb EMB145LR · Fuselage Miscellaneous StructureSDR RAIA201308290001Bulb · inoperativeSERVICE DOOR LOWER EMERGENCY EXIT LIGHT INOPERATIVE. MX REPLACED BULB AND OPS CHECKED GOOD.Aug 29, 2013 · N812HK · Emb EMB145LR · Emergency LightingSDR RAIA201307270001Bulb · inoperativeAFT SIDEWALL EMERGENCY LIGHT AT 12C INOPERATIVE. MX REPLACED BULB AND OPS CHECKED GOOD.Jul 27, 2013 · N812HK · Emb EMB145LR · Emergency LightingSDR RAIA201306290001Thermostat · failedBLEED 2 OVERHEAT IN FLIGHT DURING ICING CONDITIONS. ACFT RETURNED TO DEPARTURE AND MX INSPECTED AND REPLACED FAN AIR THERMOSTAT, OPS CHECKED GOOD.Jun 29, 2013 · N812HK · Emb EMB145LR · Pneumatic Distribution SystemSDR RAIA201306250001Bearing · failedSMOKE WAS NOTICED IN CABIN AND COCKPIT DURING CRUISE ALTITUDE. MX INSPECTED AND REPLACED THE RT ACM, OPS CHECKED GOOD.Jun 25, 2013 · N812HK · Emb EMB145LR · Cabin Cooling SystemSDR RAIA201306220001Warning Message · illuminatedDURING LANDING, THE FLIGHT CREW RECEIVED A NR E2 NGINE THRUST REVERSER FAIL MESSAGE ON EICAS. CREW SHUTDOWN THE ENGINE ON LANDING. CREW RECEIVED A EICAS MESSAGE STATING THE THRUST REVERSER DEPLOYED. OPENJun 22, 2013 · N812HK · Emb EMB145LR · Engine Thrust ReverserSDR RAIA201305140001Reservoir · lowDURING CRUISE FLIGHT THE FLIGHT CREW GOT A HDY 1 LOW QUANTITY MESSAGE. CREW DECLARED AND EMERGENCY. MAINTENANCE INSPECTED FOR HDY LEAKS, SERVICED AND BLEED THE RESERVOIR. NO LEAKS FOUND AND SYSTEM OPS CHECK GOOD.May 14, 2013 · N812HK · Emb EMB145LR · Hydraulic Reservoir, MainSDR RAIA201208220001Pin · not seatedDURING MAINTENANCE INSPECTION, FOUND EMERGENCY LIGHT IN FRONT OF SERVICE DOOR INOP. MAINTENANCE RESEATED PINS IN CONNECTOR FOR EMERGENCY LIGHT IN FRONT OF SERVICE DOOR, OPS CHECK GOOD.Aug 22, 2012 · N812HK · Emb EMB145LR · Light System WiringSDR RAIA201104190001Wire Harness · burnedDURING PRE-FLIGHT INSPECTION THE FLIGHT CREW REPORTED A BURNING ELECTRICAL ODOR NEAR ROW 11. MAINTENANCE INSPECTED AND DEFERRED THE CEILING LIGHTS AT ROW 11.Apr 19, 2011 · N812HK · Emb EMB145LR · Light System WiringSDR RAIA201104010001APrecooler · leakingDURING CLIMB THE FLIGHT CREW GOT A INDUCTION OF A NR 1 ENGINE BLEED AIR LEAK. AIRCRAFT RETURNED TO THE AIRPORT. MAINTENANCE INSPECTED AND REMOVED AND REPLACED THE PRECOOLER. SYSTEM OPS CHECKED GOOD.Apr 1, 2011 · N812HK · Emb EMB145LR · Engine Bleed Air SystemSDR RAIA201103010002Skin · damagedAIRCRAFT WAS PARKED BY THE STL HANGAR. DURING HIGH WINDS A FUEL BOWSER WAS BLOWN INTO THE AIRCRAFT, CAUSING DAMAGE TO THE FUSELAGE LT SIDE BETWEEN STRINGERS 16L TO 19L. MAINTENANCE INSPECTED AND REPAIRED THE AIRCRAFT IAW EMBRAER ETD2011-145/02251.Mar 1, 2011 · N812HK · Emb EMB145LR · Fuselage Main, Plate/SkinSDR RAIA201010190001Wire · looseDURING PRE-FLIGHT INSPECTION THE FLIGHT CREW REPORTED THE OVERHEAD EMERGENCY EXIT ROW LIGHT INOP. MAINTENANCE INSPECTED AND FOUND LOOSE WIRING. WIRING WAS RE-SECURED AND SYSTEM OPS CHECKED GOOD.Oct 19, 2010 · N812HK · Emb EMB145LR · Light System WiringSDR RAIA201009300002Sign · inoperativeDURING PRE-FLIGHT INSPECTION THE FLIGHT CREW REPORTED THE EMERGENCY EXIT SIGN AT MID CABIN AFT SIDE WAS INOP. MAINTENANCE INSPECTED AND RESET THE EMERGENCY LIGHTS SYSTEM. OPS CHECKED GOOD.Sep 30, 2010 · N812HK · Emb EMB145LR · Emergency LightingSDR RAIA2010021900001Light · inoperativeDURING THE PRE FLIGHT INSPECTION, THE CREW REPORTED THAT THE EMERGENCY LIGHT AT THE MAIN DOOR WAS INOPERATIVE. MAINTENANCE REMOVED AND REPLACED THE BULB AT THE LIGHT ASSEMBLY. OPS CHECKED GOOD.Feb 19, 2010 · N812HK · Emb EMB145ER · Emergency LightingSDR RAIA2009122600001Trim Switch · malfunctionedCREW REPORTED THE MAIN PITCH TRIM AS BEING INOPERATIVE. MAINTENANCE REMOVED AND REPLACED THE PITCH TRIM SWITCHES AND THE HSCU. SYSTEM OPS CHECKED GOOD.Dec 26, 2009 · N812HK · Emb EMB145LR · Stabilizer Control SystemSDR RAIA2009122100003Adc · malfunctionedCREW REPORTED RECEIVING A SPS ADVANCE MESSAGE ON THE EICAS ALONG WITH AN ADC1 FAIL MESSAGE. MAINTENANCE REMOVED AND REPLACED THE NR 1 ADC IAW AMM PROCEDURES. OPS CHECKED GOOD.Dec 19, 2009 · N812HK · Emb EMB145LR · Air Data ComputerSDR RAIA2009122100002Icu · activatedCREW RECEIVED AN SPS ADVANCE, ADC 1 FAIL, AND AIRSPEED COMPARATOR MESSAGE ON THE EICAS. MAINTENANCE REMOVED AND REPLACED THE ICU IAW AMM PROCEDURES. OPS CHECKED GOOD.Dec 19, 2009 · N812HK · Emb EMB145LR · Integrated Flight SystemSDR 2010FA0000146Floorbeam · corrodedFLOORBOARD PROFILE AT FRAME AT STA X 5418 RY .479 HAS CORROSION AROUND NUTPLATE. R & R BEAM IAW SRM.Dec 11, 2009 · N812HK · Emb EMB145LR · Fuselage Main, Floor BeamSDR 2010FA0000145Floor Support · corrodedFLOORBOARD PROFILE AT FRAME AT STA X 5202 AND Y 0 HAS CORROSION. R & R ANGLE IAW SRM.Dec 11, 2009 · N812HK · Emb EMB145LR · Fuselage Miscellaneous StructureSDR 2010FA0000144Floor Support · corrodedFLOORBOARD PROFILE AND INBD SIDE OF FRAME AT LY 479 AT STA X 5433 HAS CORROSION. R & R ANGLE IAW SRM.Dec 11, 2009 · N812HK · Emb EMB145LR · Fuselage Miscellaneous StructureSDR 2010FA0000143Seat Track · corrodedOTBD SIDE OF SEAT RAIL AT LY 479 FROM STA X5418 - X6523 HAS CORROSION. R & R DIGITAL IAS SRM.Dec 11, 2009 · N812HK · Emb EMB145LR · Fuselage, Seat/Cargo Attach FittingsSDR 2010FA0000142Seat Track · corrodedOTBD SIDE OF SEAT RAIL AT LY 479 FROM STA X 5415- X6523 HAS CORROSION. R & R DIGITAL IAW SRM.Dec 11, 2009 · N812HK · Emb EMB145LR · Fuselage, Seat/Cargo Attach FittingsSDR 2010FA0000141Seat Track · corrodedOTBD SIDE OF SEAT RAIL AT LY 479 FROM STA X 5412-5423 HAS CORROSIO. R & R DIGITAL IAW SRM 51-10-02, 51-40-02.Dec 11, 2009 · N812HK · Emb EMB145LR · Fuselage, Seat/Cargo Attach FittingsSDR 2010FA0000140Sill · corrodedLT FLOORBOARD PROFILE AT STA X5633 OTBD OF LY479 HAS CORROSION. REMOVED DAMAGED SILL, LOCATED, DRILLED ALODINED AND PRIMED BARE AREAS, COUNTERSUNK AND INSTALLED IAW SRM.Dec 11, 2009 · N812HK · Emb EMB145LR · Fuselage Miscellaneous StructureSDR 2010FA0000138Gusset · corrodedSUPPORT BEAM AROUND SOME NUT PLATES HAS CORROSION. REMOVED AND REPLACED GUSSET IAW SRM.Dec 11, 2009 · N812HK · Emb EMB145LR · Fuselage Miscellaneous StructureSDR 2010FA0000137Profile · corrodedFRAME TOP PROFILE AT FRAME 62LY .478-844 HAS CORROSION. REMOVED AND REPLACED PROFILE IAW SRM.Dec 11, 2009 · N812HK · Emb EMB145LR · Fuselage Main, FrameSDR 2010FA0000136Profile · corrodedFRAME TOP PROFILE AT FRAME 62 RY .479-644 HAS CORROSION. REMOVED AND REPLACED PROFILE IAW SRM 51-00-000.Dec 11, 2009 · N812HK · Emb EMB145LR · Fuselage Main, FrameSDR 2010FA0000131Doubler · corrodedDOUBLER RT .478 FRAME 22 HAS CORROSION. R & R DOUBLER IAW 145 SRM.Dec 11, 2009 · N812HK · Emb EMB145LR · Fuselage Structure (General)
Back to N812HK, cancelled May 7, 2019