N815EX, cancelled Feb 14, 2022
Service difficulty reports · 148
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N815EX' AND deregistration_id = 'N815EX-2022-02-14' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N815EX' AND deregistration_id = 'N815EX-2022-02-14' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR HNAA2016102400332Unknown · odorELECTRICAL ODOR IN COCKPIT. INSPECTED THE WINDSHIELD HEAT WIRING AND INVERTERS FOR DEFECTS. NONE FOUND. GROUND RAN ENGINES WITH BLEEDS ON. NO ODORS NOTED. OK FOR SERVICE.SDR HNAA2016051900147Wire · chafedCABIN EMERGENCY LIGHTS FLASH ON AND OFF INTERMITTENTLY AT CRUISE FLIGHT AND WITH PROP HEAT ON. REPAIRED 15 CHAFED WIRES JUST FWD OF NR 2 AC CONTACTOR BOX USING SPLICES AND NEW WIRE REF AMM 20-45-08. GROUND RAN ACFT. AC SYSTEM OPS CHECK GOOD.
OK FOR SERVICSDR HNAA2016050900141Relay · malfunctionedFOLLOW UP CABIN EMERGENCY LIGHTS STARTED TO FLICKER WHEN PROP HEAT SELECTED. CYCLED PROP HEAT OFF AND LIGHTS STOPED. TURNED HEAT BACK ON AND EMERGENCY LIGHTS DID NOT COME BACK ON DUE TO EXTENSIVE HISTORY REQUIRES FURTHER TROUBLESHOOTING. R & R RELAYS 2431-K18SDR HNAA2016050900140Brush Block · dirtyCABIN EMERGENCY LIGHTS STARTED TO FLICKER WHEN PROP HEAT SELECTED. CYCLED PROP HEAT OFF AND LIGHTS STOPED. TURNED HEAT BACK ON AND EMERGENCY LIGHTS DID NOT COME BACK ON INSPECTED AND CLEANED BOTH PROP BRUSH BLOCK ASSEMBLIES AS REQUIRED. NO DEFECTS FOUND AT THSDR HNAA2016031600080Relay · malfunctionedDURING CLIMB, EMERGENCY LIGHTS FLICKERING WITH PROPS AT 1050. R & R RELAYS 2821 K1 AND K2. RAN AIRCRAFT AUXILIARY FUEL PUMPS AND PROP HEAT. EMERGENCY LIGHTS, OPS CHECKED GOOD.SDR HNAA2016031400078Brush Block · dirtyEMERGENCY LIGHTS FLASHED 5 TIMES DURING CLIMBOUT. CLEANED AND INSPECTED NR 1 AND NO. 2 BRUSH BLOCK. NO DEFECTS NOTED. GROUND RAN ACFT. OPS CHECK GOOD. OK FOR SERVICE.SDR HNAA2016031400077Control Box · malfunctionedWHEN NR 2 PROP HEAT A PHASE ILLUMINATES, EMERGENCY LIGHTS ACTIVATE. INSPECTED NR 2 PROP LEADS . NO DEFECTS NOTED. R & R EMERGENCY LIGHTS CONTROL BOX. OPS CHECK GOOD IAW 33-51-00. ACFT OK FOR SERVICE.SDR HNAA2016030900073Lead · chafedEMERGENCY LIGHTS FLICKERING WITH PROP HEAT SELECTED ON. FOUND CHAFED PROP LEAD AT LEFT, PROP NR 2 BLADE. R & R PROP LEAD. OPS CHECK OK AT THIS TIME.SDR HNAA2016022900063Switch · inoperativeEMERGENCY LIGHTING SWITCH BACK LIGHT INOPERATIVE WHEN ON, YELLOW, IS SELECTED. R & R EMERGENCY LIGHT SWITCH.SDR HNAA2016022600056Brush Block · shortedEMERGENCY LIGHTS FLICKERED WITH PROP SPEED AT 1050 AND PROP TIMER ON THE RT "A" PHASE. R & R BRUSH BLOCK IAW MM 61-10-11. OPS CHECKED GOOD. OK FOR SERVICE.SDR HNAA2015012500020Bulb · inoperativeEMERGENCY FLOOR LIGHT IS INOPERATIVE AT ROW 1. R & R BULB AT ROW 1 EMERGENCY FLOOR LIGHT. OPS CHECKED GOOD.SDR HNAA2016011500007Brush Block · dirtyCABIN EMERGENCY LIGHTS FLICKERED IN FLIGHT WITH PROP DE-ICE SELECTED. INSPECTED AND CLEANED BRUSH BLOCKS ASSY ON NR 1 AND NR 2 ENGINES. R & R EMERGENCY CONTROL BOX. RAN ACFT AND CHECKED PROP HEAT. NO DISCREPANCIES NOTED. OK FOR SERVICE.SDR HNAA2016010400003Lamp · burned outEMERGENCY EXIT SIGN ON LOWER FWD OF PAX DOOR HAS INOPERATIVE LAMP. R & R LAMP AND REINSTALLED LENS COVER.SDR HNAA2016010400000Brush Block · contaminatedFLOOR EMERGENCY LIGHTS FLICKER INTERMITTENTLY WITH PROP HEAT ON. INSPECTED 1 AND 2 PROP BRUSH BLOCKS, FOUND TO BE WET WITH DEICE FLUID. CLEANED AS REQUIRED. NO DEFECTS FOUND AT THIS TIME. GROUND RAN BOTH ENGINES FOR 25 MINUTES, OPS NORMAL IAW RUNUP MANUAL, OSDR HNAA2015122800374Computer · out of adjustUNCOMMANDED STICK SHAKERS ON DURING ROTATION. RETURNED TO FIELD. SHAKERS STOPPED WHEN ACFT ON THE GROUND. FOUND NR 1 STALL WARNING COMPUTER SLIGHTLY OUT OF ADJUSTMENT. CALIBRATED NR 1 AND NR 2 STALL WARNING COMPUTER. OPS AND FUNCTION CHECKED GOOD IAW MM 2SDR HNAA2015122100369Brush Block · shortedEMERGENCY LIGHTS FLICKERED AND CYCLED ON/OFF WITH PROP HEAT ON AND PROPS AT 1050. GOOD WITH PROP HEAT OFF. INSPECTED NR 2 PROP, A PHASE SLIP RINGS AND LEADS. NO DEFECTS NOTED. R & R NR 2 BRUSH BLOCK. GROUND RAN. OPS CHECKED NORMAL AT THIS TIME.SDR HNAA2015110400322Battery · unknownAUXILIARY BATTERY HOT WARNING LIGHTS IN FLIGHT. AUXILIARY BATTERY TEMP IS 65 DEGREES. COMPLIED WITH CHECKLIST. R & R AUX BATTERY IAW MM 24-32-00. OPS CHECKED GOOD.SDR HNAA2015082800266Firewall · chafedNR 1 NACELLE, INBD Z MEMBER HAS CRACK IN LIP AT ABOUT 4" ABOVE START OF LIP IN FIREWALL WEB CHAFE. RIMMED FIREWALL PLATE IAW RD8-54-991. REPAIRED CHAFE AND TRIMMED OUT AREA IAW EO8-54-15-0176.SDR HNAA2015031600101None · nonePOSSIBLE ANIMAL STRIKE DURING ROLL OUT. INSPECTED PLANE AND FOUND NO EVIDENCE OF ANIMAL STRIKE.SDR HNAA2015030400074Bulb · inoperativeEMERGENCY FLOOR PATH LIGHTS ARE INOPERATIVE AT ROWS 1, 3 AND 7. R & R BULBS FOR EMERGENCY FLOOR PATH LIGHT. OPS CHECKED GOOD.SDR HNAA2015022000057Battery · inoperativeCEILING EMERGENCY LIGHT AT ROW 3 IS INOPERATIVE. R & R EMERGENCY LIGHT BATTERY IN ROW 3 CEILING LIGHT. OPS CHECKED GOOD.SDR HNAA2015022000056Battery · inoperativeLEFT AFT FUSELAGE EMERGENCY LIGHT IS INOPERATIVE. R & R POWER SUPPLY 3351, PS3 IAW MM 33-51-00.SDR HNAA2015020200029Lamp · inoperativeEMERGENCY LIGHTS SWITCH NORMAL GREEN LIGHT INOPERATIVE. R & R LAMP, OPS CHECKED GOOD.SDR HNAA2015012800028Bulb · inoperativeEMERGENCY LIGHT IS INOPERATIVE AT ROW 1. R & R THE BULB. OPS CHECKED GOOD.SDR HNAA2015012800027Bulb · inoperativeEMERGENCY LIGHT IS INOPERATIVE. R & R BULB. OPS CHECKED GOOD.SDR HNAA2014122900383Bulb · inoperative9TH EMERGENCY LIGHT IS INOPERATIVE. R & R BULB. OPS CHECKED GOOD.SDR HNAA2014120800353Warning Horn · false activationDURING POWER UP FOR TAKEOFF AT 65 PERCENT TORQUE, TAKEOFF WARNING HORN SOUNDED. REJECTED TAKEOFF. CLEANED AND INSPECTED FLAP INDICATOR CONNECTOR. NO DEFECTS NOTED. CREW GROUND RAN ACFT AND INSPECTED SYS IAW MM 31-51-00. HORN STILL SOUNDED DURING POWER RUNSDR HNAA2014120800352Indicator · malfunctionedDURING TAKEOFF ROLL, TAKEOFF WARNING HORN SOUNDED. ABORTED TAKEOFF. CYCLED FLAPS, ELEVATOR TRIM AND ECU MODE SWITCHES. GROUND RUN ACFT, HORN DID NOT SOUND. CONFIRMED FLAP INDICATOR CAUSING TAKEOFF WARNING WHILE IN PROPER CONFIGURATION. R & R FLAP INDICATOSDR HNAA2014111200317Bulb · inoperativeEMERGENCY LIGHTS ARE INOPERATIVE AT ROWS 3, 4 AND 6. R & R THE BULBS. OPS CHECKED GOOD.SDR HNAA2014111200316Bulb · inoperativeLEFT AFT EXTERIOR EMERGENCY LIGHT IS INOPERATIVE. R & R THE BULB. OPS CHECKED GOOD.SDR HNAA2014102200296Light · no testRIGHT FORWARD EMERGENCY EXIT LIGHT FAILED COMPARATOR CHECK. R & R THE LIGHT ASSY.SDR HNAA2014102200295Bulb · burned outTHE 6TH EMERGENCY FLOOR PATH LIGHT BETWEEN ROWS 1 AND 2 IS INOPERATIVE. REPLACED BULB, OPS CHECKED GOOD.SDR HNAA2014092200270Bulb · inoperativeCEILING EMERGENCY LIGHT IS INOPERATIVE AT ROW 3. R & R LIGHT BULB FOR CEILING EMERGENCY PATH LIGHT, OPS CHECKED GOOD.SDR HNAA2014091900264Bulb · inoperativeRT AFT EMERGENCY EGRESS LIGHT IS INOPERATIVE. R & R BULB. OPS CHECKED GOOD.SDR HNAA2014090500257Bulb · inoperativeEMERGENCY LIGHTS ARE INOPERATIVE AT ROWS 4 AND 8. R & R BULBS IAW MM 33-51-11. OPS CHECKED GOOD.SDR HNAA2014073000217Generator · failedNR 1 AC GENERATOR CAUTION LIGHT ILLUMINATED AND WILL NOT RESET. R & R NR 1 AC GENEREATOR AND GCU IAW WC 24-20-11R AND MM 24-21-02. OPS AND LEAK CHECKED GOOD.SDR HNAA2014061800184Knob · unsecureFIRST OFFICER`S TRANSMIT SELECT KNOB ON ACP LOOSE. SECURED SELECT KNOB. OPS CHECKED GOOD. OK FOR SERVICE.SDR HNAA2014052100160Bulb · weakLEFT AFT EXTERNAL FUSELAGE EMERGENCY LIGHT IS DIM. R & R BULB, OPS CHECKED GOOD.SDR HNAA2014050500149Light · missingRED FLOOR EMERGENCY LIGHT MISSING. INSTALLED RED FLOOR LIGHT MODULE. OPS CHECKED GOOD. OK FOR SERVICE.SDR HNAA2014042100135Bulb · dimEMERGENCY CEILING LIGHT DIM AT ROW 1AND 3. R & R EMERGENCY EMERGENCY CEILING LIGHT BULBS AT ROW 1 AND 3. OPS CHECKED GOOD.SDR HNAA2014012300018Bulb · inoperativeCEILING EMERGENCY LIGHT IS INOPERATIVE AT ROW 9. R & R BULB. OPS CHECKED GOOD.SDR HNAA2013123100648Flange · crackedLEFT NACELLE COLLAR FLANGE IS CRACKED AT FORWARD END. R & R FORWARD ANGLE ON LT COLLAR IAW AMM 54-40-04, 54-40-06 AND EO8-54-13-0696.SDR HNAA2013102500547Light · inoperativeEMERGENCY LIGHT IS INOPERATIVE AT ROW 1. R & R EMERGENCY LIGHT IAW AMM 33-51-00. OPS CHECKED GOOD.SDR HNAA2013102500546Bulb · malfunctionedEMERGENCY EXIT DOOR SIGN IS DIM. R & R EXIT SIGN BULBS. OPS CHECKED GOOD IAW AMM 33-51-00.SDR HNAA2013102100542Bulb · inoperativeEMERGENCY LIGHT INOPERATIVE AT ROWS 1 AND 3. R & R BULBS, OPS CHECKED GOOD.SDR HNAA2013102100539Unknown · odorON APU BLEED START, STRONG FUEL ODOR ENTERED CABIN. NO LEAKS FOUND OR OBVIOUS DEFECTS. GROUND RAN ACFT WITH DOORS OPEN FOR 10 MINUTES AND CABIN ODOR CLEARED AT THIS TIME,SDR HNAA2013082600475Unknown · odorELECTRICAL BURNING ODOR APPEARS TO BE COMING FROM OVERHEAD LIGHTS AT ROW 7DF. R & R LAMP HOLDER, BULB AND BALLAST. OPS CHECKED GOOD.SDR HNAA2013061200333Ahrs · failedNR 2 AHRS FAILED. NR 2 ADI READ 10 DEGREES PITCH OP. CYCLED NR 2 AHRS, CIRCUIT BREAKER ADI CORRECTED PITCH. R & R ARHU. OPS CHECKED GOOD IAW 34-20-06.SDR HNAA2013052900314Light · inoperativeTWO RED FLOOR EMERGENCY LIGHTS ARE INOPERATIVE. R & R ONE LAMP AND ONE LIGHT SOCKET AT ROW 1. OPS CHECKED GOOD.SDR HNAA2013050300250Bulb · failedLEFT AFT FUSELAGE EMERGENCY LIGHT IS INOPERATIVE. R & R BULB IAW AMM 33-51-00.
Back to N815EX, cancelled Feb 14, 2022