N818AE, cancelled May 23, 2025
Service difficulty reports · 93
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N818AE' AND deregistration_id = 'N818AE-2025-05-23' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N818AE' AND deregistration_id = 'N818AE-2025-05-23' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR SIMA202003198001Audio Panel · failedELECTRICAL BURNING SMELL AS INDICATED ON PAGE 9134 MECH DISC #1-C/A-PERFORMED WORK SCOPE FROM MOC AND FIM TASK # 21-20-00-810-801. NO EVIDENCE OF ELECTRICAL BURNING SMELL FOUND. CA SPEAKER CANT TURN OFF, STATIC INTERMITTENT, ELECTRICAL BURN SMELL. REPMOVED ANDSDR SIMA202001021001Lamp · inoperative11A OVERHEAD EMERGENCY LIGHT INOP-C/A-REMOVED AND REPLACED 11A OVERHEAD EMERGENCY LIGHT LAMP IAW EMB AMM 33-50-08-000-801-A AND 33-50-08-400-801-A. OPS CHECK GOOD.SDR SIMA20191107002Anti-Ice Valve · failedWG A/ICE FAIL ON DESCENT IN ICING CONDITIONS, QRH COMPLIED WITH, MESSAGE WENT AWAY-C/A-REMOVED AND REPLACED WING A/ICE VALVE 2. IAW AMM 30-11-01. NO DEFECTS NOTED. HIGH PWR RUN REQ'D. PERFORMED HIGH POWER RUN FOR WING 2 ANT ICE VALVE OPC. GOOD IAW EMB 14SDR SIMA2019083029001Door · lack of lubeMAIN CABIN DOOR DIFFICULT TO CLOSE AND OPEN. INSPECTED ,CLEANED & LUBED MAIN DOOR ACTUATING & LOCKING MECHANISM IAW AMM 52-11-00 OPS CHECKS GOOD.SDR SIMA201906243001Mechanism · lack of lubeFA REPORTS MAIN DOOR DIFFICULT TO OPEN AND CLOSE. LUBRICATED MAIN DOOR ACTUATING AND LOCKING MECHANISM IAW EMB 140 AMM 52-18-00. OPC GOOD.SDR SIMA201906032002Flashlight · malfunctionedFWD FLASHLIGHT FLICKERS WHEN TURNED TO ON. REMOVED AND REPLACED FWD FLASHLIGHT ASSY IAW AMM 33-50-16 OPC GOODSDR SIMA20190520001Door · lack of lubeFA UNABLE TO OPEN PAX DOOR FROM INSIDE. DOOR IS ABLE TO OPEN FROM THE OUTSIDE. C/A-APLIED LUBED TO PAX DOOR IAW AMM 52-10-00.SDR SIMA201812031004Light · inoperativeEMERGENCY LIGHT ABOVE FA SEAT FOUND TO BE INOP DURING PS2 CHECK-C/A-REMOVED AND REPLACED PANEL SIGN ASSEMBLY OF FWD EXIT SIGN IAW EMB140 AMM 33-50-14. OPC FAIL. ITEM REQUIRES FURTHER T/S. REMOVED AND REPLACED INVERTER FROM FWD CABIN CLOSET IAW EMB140 AMM 33-5SDR SIMA201806186004Handle · lack of lubeMAIN PAX DOOR HANDLE BINDING, UNABLE TO OPEN THE DOOR. CLEANED, LUBRICATED, AND TESTED THE MAIN PAX DOOR IAW AMM 52-18-00. OPS CHECKED GOOD. ACFT OK FOR SERVICE.SDR SIMA201805140006Engine · odorWITH THE RT ENGINE RUNNING AT MAX POWER, THE NR 2 BLEED OPEN AND NR 1 PACK SELECTED, A STRONG ODOR WAS PRESENT IN THE COCKPIT. WITH THE RT ENGINE AT MAX POWER AND NR 1 BLEED OPEN, AND NR 1 PACK SELECTED, NO ODOR PRESENT, THE RT ENGINE IS PROCUDING A STRONSDR SIMA2018042700001Roller · lack of lubeMAIN CABIN DOOR WILL STICH & NOT CLOSE OR OPEN. LUBRICATED MAIN DOOR ROLLERS AND OPS CHECKED GOOD IAW AMM 52-18-00.SDR SIMA20180403003Support · looseCARGO DOOR OPENED AFTER TAKEOFF, NO PRESSURIZATION ISSUES. FOUND THE AFT CARGO DOOR SWITCH SUPPORT LEVER WITH A LOT OF PLAY. REMOVED AND REPLACED THE AFT CARGO DOOR SWITCH IAW AMM 52-76-01-04, OPS CHECKED IAW AMM 52-76-01-05, AND PRESSURIZED AIRCRAFT IAW SDR SIMA20180323003Sign · inoperativeAFT EMERGENCY EXIT ROW 11 A, B, & C CENTER AISLE INOPERATIVE. CONNECTED THE AFT OVERHEAD EMERGENCY EXIT SIGN. OPS CHECKED GOOD.SDR SIMA20180203003Connector · brokenNR 1 EMERGENCY LIGHT CONNECTOR FOUND BROKEN. REMOVED AND REPLACED THE CONNECTOR IAW SWPM 20-21-00.SDR SIMA20180203004Frame · chafedFRAME 81 HAS MULTIPLE CHAFES AT THE 6 O'CLOCK POSITION. ACCOMPLISHED A REPAIR IAW ERS-EM-53MR-3111.SDR SIMA20180126008Door Sill · corrodedSERVICE DOOR LOWER SILL IS CORRODED AROUND 2 SCREW HOLES. REMOVED CORROSION, SERVICE DOOR LOWER SILL AROUND 2 SCREW HOLES. IAW CPM 51-14-02. BLENDED AREA ON SERVICE DOOR LOWER SILL AROUND FWD SCREW HOLE FOUND TO BE WITHIN ALLOWABLE LIMITS IAW SRM 53-21-02.SDR SIMA20180126009Door Sill · corrodedCARGO DOOR CUT-OUT LOWER SILL CORRODED. REMOVED AND REPLACED THE DOOR SILL IAW SRM 51-40-02, AND 51-20-03.SDR SIMA20180126010Angle · corrodedCARGO DOOR CUT-OUT FWD ANGLE CORRODED ON LOWER END. REMOVED AND THE ANGLE IAW SRM 53-31-04, FIGURE 212.SDR SIMA20180125005Frame · chafedFRAME 69 CHAFED AT THE V-BAND CLAMP, STRINGER 19L. REPAIRED THE FRAME IAW SRM 53-00-04.SDR SIMA20180125004Skin · chafedRUDDER 1 HAS CHAFE ABOVE PANEL 326AL. REPAIRED THE SKIN IAW ERS-EM-55MR-633.SDR SIMA20170414003Light · unknownMAIN DOOR EXTERNAL EMERGENCY LIGHT INOPERATIVE. PERFORMED AN OPS CHECK, CHECKED GOOD IAW AMM TASK 33-50-00-700-801-ASDR SIMA20161216001Tank Unit · failedIMMEDIATELY AFTER TAKE OFF, RECEIVED A FUEL IMBALANCE. TANK 1 INDICATION DROPPED APROX. 900 LBS. BOTH QUANTITY INDICATIONS WERE ERRATIC AND BECAME UNRELIABLE. DECLARED EMERGENCY AND RETURNED TO DEPARTURE. REMOVED AND REPLACED FUEL T/U NR 2 ON LT SIDE AND FUESDR SIMA20160323002Connector · brokenFLOOR PROXIMITY STRIP LIGHT AT FLOORBOARD 251JF HAS A BROKEN CONNECTOR. REPAIRED FLOOR PROXIMITY STRIP LIGHT IAW SWPM 20-21-00. OPERATIONS CHECKED GOOD.SDR SIMA20151229002Filter · dirtyBLEED 1 OVERTEMP INFLIGHT. VISUALLY INSPECTED FAN AIR VLV LINES, NO DAMAGE FOUND. FOUND CLEAN FAN AIR VLV FILTER IAW AMM 36-11-03. PERFORMED OPERATIONS CHECK IAW AMM 36-00-00, DID NOT FIX REF ITEM 3. R & R FAN AIR VLV IAW AMM 36-11-03. OPERATIONS CHECKED SDR SIMA20151127001Detector · failedAFTER TAKING RUNWAY FOR POSITION & HOLD RECEIVED ICE CONDITION ADVISORY MSG FOLLOWED BY A ICE CONDITION. ANTI-ICE WARNING MSG PRIOR TO TAKEOFF ROLL. AFTER A FEW MINUTES MSG'S WENT AWAY BUT CAME BACK AGAIN, ON TAXI BACK TO GATE. TROUBLESHOOT SYS FOUND NR 1 ISDR SIMA20151125002Wire · brokenLIGHT ELEMENT OF PROXIMITY LIGHT STRIP, NR 6 HAS A BROKEN WIRE. R & R NR 6 FLOOR PROXIMITY LIGHT STRIP IAW AMM 33-50-12. SEE NRTC BOW 205943 FOR OPERATIONAL CHECK.SDR SIMA20151125003Frame · crackedFRAME 23 IS CRACKED, BETWEEN STRINGER 15R - 16R. REPAIRED FRAME 23 AT STRINGER 16R IAW SRM 51-40-02 & EO EM-53MR-1808.SDR SIMA20151125004Connector · missingEMERGENCY LIGHT STRIP WIRE AT SEAT LOCATION 13 A IS MISSING SPLICE CONNECTOR. REPAIRED & INSTALLED SERVICEABLE SPLICE CONNECTOR ON EMER LIGHT STRIP WIRE AT SEAT LOCATION 13A IAW SWPM 20-21-00. SEE BOW 205943 FOR OPERATIONS CHECK.SDR SIMA20151125001Wire · chafedPROXIMITY LIGHT STRIP NR 1 WIRE AT THE FLOORBOARD IS MISSING AN ELEC CONNECTOR & THE SAME WIRE IS CHAFED WITH BARE WIRE SHOWING. R & R ELEC CONNECTOR, MALE & ACFT SIDE, AT SPLICE SP9019 FOR THE NR 1 PROXIMITY LIGHT STRIP IAW SWPM 20-21-00, 20-50-00 & 20-50-01SDR SIMA20151123003Skin · crackedPOSSIBLE CRACKS ON LT REAR FUSELAGE RIVETS FRAMES 77 - 79. REPAIRED LT UPPER FUSELAGE SKIN CRACK AT FRAME 77 & STRINGER 06L IAW ERS-EM-53MR-1795.SDR SIMA20151121009Floorbeam · corrodedCENTER FLOORBEAM HAS CORROSION AFT OF THE CROSS MEMBER AT FRAME 27. REPAIRED CTR FLOORBEAM CORROSION AFT OF THE CROSS MEMBER AT FRAME 27 BY INSTALLED EXTERNAL ANGLE, FILLER & SHIMS IAW SRM 53-00-10, 51-40-02. CPM 51-21-06, ETN-EM-51-075 & ETN-EM-51-091.SDR SIMA20151121008Floor Support · corrodedLEFT OMEGA BEAM HAS CORROSION, FWD OF THE CROSS MEMBER AT FRAME 27. REPAIRED LT OMEGA BEAM CORROSION BY INSTALLING REPAIR DOUBLER IAW SRM 53-00-10 FIG 202 SHEET 2, CPM 51-21-05 & ETN-EM-51-075.SDR SIMA20151121007Skin · crackedRIGHT UPPER FUSELAGE SKIN CRACKED AFT OF FRAME 75 & ABOVE STRINGER 2R, CRACK IS APPROX 3/8" LONG. REPAIRED IAW ERS-EM-53MR-1793.SDR SIMA20151120008Door Sill · corrodedFORWARD SERVICE DOOR SILL IS CORRODED. REPAIRED FWD SERVICE DOOR SILL IAW ERS-EM-53MR-1792.SDR SIMA20151106012Connector · missingEMERGENCY LIGHT STRIP WIRE AT SEAT LOCATION 13A IS MISSING SPLICE CONNECTOR. REPAIRED & INSTALLED SERVICEABLE SPLICE CONNECTOR ON EMER LIGHT STRIP WIRE AT SEAT LOCATION 13A IAW SWPM 20-21-00. SEE BOW 205943 FOR OPERATIONS CHECK.SDR SIMA20151027001Bolt · leakingSTRONG FUEL SMELL IN COCKPIT. REMOVED, REINSTALLED & RESEALED BOLT AT STRINGER 18R & FRAME 40 IAW AMM 20-10-01 & SRM 51-21-01. SEE NRWC 818-ABI-02100 FOR DETAILS.SDR SIMA20150811001Light · inoperativeEMERGENCY LIGHT IN PSU PANEL AT SEAT 11A INOPERATIVE. REMOVED & INSTALLED SERVICEABLE LAMP IN PSU PANEL AT SEAT 11A IAW AMM 33-50-07. OPERATIONS CHECKED GOOD.SDR SIMA20150621005Controller · failedAFTER CLIMB OUT ACFT WAS NOT PRESSURIZING. WE CLIMBED UP TO 10000 FT & RETURNED. R & R AUTO DIGITAL CONTROL IAW AMM 21-21-01. OPERATIONS CHECKED GOOD. PERFORMED FUNCTIONAL AUTO PRESSURIZATION TEST IAW AMM 21-31-00. OPERATIONS CHECKED GOOD.SDR SIMA20150414001Brake · contaminatedHYDRAULIC FLUID UNDER NR 1 BRAKE ASSEMBLY. VISUAL CHECK & OPERATIONAL OF NR 1 BRAKE ASSEMBLY NO LEAKS NOTED IAW AMM 32-41-00.SDR SIMA20150405001Unknown · odorAT FL 310 IN & OUT OF WEATHER INCLUDING THUNDERS STORM CELLS IN VICINITY, STRONG ODOR OF SMOKE POSSIBLY ELEC IN COCKPIT & CABIN LASTING 2 - 3 MINUTES & DISSIPATED. ODOR IN CABIN LASTED UNTIL LANDING, NEVER SAW SMOKE ONLY SMELLED SMOKE. DECLARED EMER LANDINGSDR SIMA20150302002Cradle · brokenCAPTAINS EMER FLASHLIGHT CRADLE BROKEN. R & R CAPTAINS EMER FLASHLIGHT CRADLE IAW TASK 33-50-16-000-801-A & TASK 33-50-16-400-801-A. OPERATIONS CHECKED GOOD.SDR SIMA20150110001Cradle · brokenTRANSFERRED FROM NRWC 818-CMI-01732 ITEM 1. FWD CABIN FLASHLIGHT CRADLE BROKEN. FLIGHT ATTENDANT FWD FLASHLIGHT ASSEMBLY DEFERRED IAW MEL 25-53. FLIGHT ATTENDANT SPARE FLASHLIGHT STORED FWD ENTRY RT STORAGE. R & R CRADLE IAW AMM 25-61-02. OPERATIONS CHECKSDR SIMA20141222006Flashlight · intermittentFLASHLIGHT IN FWD CABIN IS INTERMITTENT. R & R FWD CABIN FLASHLIGHT IAW AMM 33-50-16.SDR SIMA20141222007Flashlight · inoperativeFLASHLIGHT IN THE AFT CABIN IS INOPERATIVE. R & R AFT CABIN FLASHLIGHT IAW AMM 33-50-16.SDR SIMA20141114001Warning System · false activationACCESS DOOR OPEN ON EICAS & DOORS ON MFD SHOWS FWD AVIONICS DOOR OPEN AS GEAR CAME UP ON TAKEOFF. OPENED & CLOSED FWD ELEC COMPARTMENT DOOR. OPERATIONS CHECKED GOOD IAW AMM 52-71-00.SDR SIMA20141108002Light · inoperativeDURING PS 1 INSPECTION FOUND RT AFT EXTERNAL EMER LIGHT INOPERATIVE. R & R RT AFT EXTERNAL EMER LIGHT IAW AMM 33-50-10. OPERATIONS CHECKED GOOD.SDR SIMA20140525002Cradle · brokenFIRST OFFICER`S EMERGENCY FLASHLIGHT CRADLE BROKEN. R & R FIRST OFFICER`S EMERGENCY FLASHLIGHT CRADLE IAW AMM 33-50-16-000-801-A & 33-50-16-400-801-A. OPERATIONS CHECKED GOOD AT THIS TIME.SDR SIMA20140521003Control Valve · malfunctionedDURING TAXI AFTER LANDING, RECEIVED SEVERAL BRAKE DEGRADED, WARNING MESSAGES ON EICAS. REPLACED RT INBD SHUTTLE VALVE. AMM ETN-EM-32-236 DID NOT FIX THE PROBLEM, BRAKE DEGRADE REMAINS. REMOVED AND REPLACED BRAKE CONTROL VALVE ELECTRICAL CONNECTOR IAW STSDR SIMA20140510002Windshield · crackedWINDSHIELD ON FIRST OFFICER`S SIDE CRACKED TAXING IN. R & R FIRST OFFICER`S WINDSHIELD IAW AMM 56-10-01. OPERATIONS CHECK LEAK TESTED GOOD IAW ITEM NR 3 & NR 4 DEFERRALS.SDR SIMA20140417003Holder · brokenFLIGHT ATTENDANT`S FWD FLASHLIGHT HOLDER BROKEN. R & R FLIGHT ATTENDANT`S FWD FLASHLIGHT HOLDER IAW AMM 35-50-00, OPERATIONS CHECKED GOOD.