SDR FDKA2010060800140Flashlight · inoperativeAFT F/A FLASHLIGHT INOP. MX R2 FLASHLIGHT, OPS GOOD ON 06/10/2010 ITEM 0076504.Jun 8, 2010 · N825MJ · Emb EMB145LR · Emergency EquipmentSDR FDKA2010053100130Handle · brokenPAX DOOR ASSIST HANDLE BROKEN. MX RE-INSTALLED HANDLE.May 31, 2010 · N825MJ · Emb EMB145LR · Passenger/Crew DoorsSDR FDKA2010052600125Wire · brokenAFT F/A FLASHLIGHT NOT CHARGING. MX REPAIRED BROKEN WIRE, OPS CHECK GOOD.May 26, 2010 · N825MJ · Emb EMB145LR · Equipment/Furnishings WiringSDR FDKA2010041100071Unknown · odorOVERWHELMING FUEL SMELL ON T/O. PERFORMED OPS CHECK, NO FUEL SMELL OR LEAK NOTED.Apr 11, 2010 · N825MJ · Emb EMB145LR · Air Distribution SystemSDR FDKA2010040300061Unknown · odorFUEL SMELL DURING TAKEOFF AND LANDING. PERF OPS CHECK WITH ENG & APU RUNNING, NO FUEL SMELL.Apr 3, 2010 · N825MJ · Emb EMB145LR · Air Distribution SystemSDR FDKA2010031300041Bleed Valve · faultyFUEL SMELL IN AC AFTER T/O. PLACED ON MEL. R2 APU BLEED VALVE, OPS GOOD CLEARED MEL.Mar 13, 2010 · N825MJ · Emb EMB145LR · APU Bleed Air SystemSDR FDKA2010031000037Unknown · odorFUEL SMELL AFTER T/O (COMING FROM APU BLEED SOURCE). MX PLACED ON MEL AND LATER FOUND OPS NORMAL WITHOUT ANY FUEL ODORS.Mar 10, 2010 · N825MJ · Emb EMB145LR · Air Distribution SystemSDR FDKA2010030300033Unknown · malfunctionedDECLARED EMERGENCY RT TANK WENT TO ZERO. RESET SYSTEM, PERFORMED ADJUSTMENT TEST, OPS CHECK NORMAL.Mar 2, 2010 · N825MJ · Emb EMB145LR · Fuel Indicating SystemSDR FDKA2010020800022Unknown · odorREPORTED A STRONG FUEL ODOR IN THE CABIN AFTER TAKEOFF. RAN APU AND ENG'S NO LEAKS NOTED NO SMELL NOTED.Feb 8, 2010 · N825MJ · Emb EMB145LR · Air Distribution SystemSDR FDKA2010012000009Unknown · odorAFTER TAKEOFF FUEL SMELL IN CABIN AND COCKPIT. PERFORMED GROUND RUNS, PACKS AND BLEEDS NO DEFECTS NOTED.Jan 20, 2010 · N825MJ · Emb EMB145LR · Air Distribution SystemSDR FDKA2010011000005Charger · inoperativeFWD RT WING E-LIGHT INOP. REMOVED AND REPLACED NR 2 BATTERY CHARGER.Jan 10, 2010 · N825MJ · Emb EMB145LR · Emergency LightingSDR FDKA2009121600209Unknown · odorFLT 6120. DURING TAKEOFF CLIMB AND WHEN THE BLEED SOURCE WAS SWITCHED FROM THE APU BLEED TO THE ENGINE BLEED A FUEL ODOR CAME OVER THE COCKPIT & CABIN. CHECKED FOR LEAKS WITH NONE NOTED. RAN APU FOR AN HOUR WITH NO DEFECTS. PERFORMED ENGINE RUN WITH APU ONDec 16, 2009 · N825MJ · Emb EMB145LR · Air Distribution SystemSDR FDKA2009031900053Fuel Filter · looseFLR FLT 6223 JFK-CLT. FUEL SMELL IN COCKPIT DURING TAKEOFF. MX FOUND FUEL FILTER ASSY LOOSE. RE-SECURED AND PERFORMED OPS CHECKS AND CHECKS WERE NORMAL.Mar 19, 2009 · N825MJ · Emb EMB145LR · APU Engine Fuel and ControlSDR FDKA2008120300305Handle · out of adjustFRL FLT 6268 IAD. MAIN CABIN DOOR INNER HANDLE CATCHES ON DOOR TRIM. MX ADJUSTED HANDLE, OPS CHECKED GOOD.Dec 3, 2008 · N825MJ · Emb EMB145LR · Passenger/Crew DoorsSDR FDKA2008102800283Door · lack of lubeFRL FLT 6243 IAD-JFK. MAIN CABIN DOOR HARD TO OPEN. MX LUBED DOOR, OPS GOOD.Oct 28, 2008 · N825MJ · Emb EMB145LR · Passenger/Crew DoorsSDR FDK2008F00014Pump · failedDECLARED AN EMERGENCY DUE TO HYDR 2 PRESSURE AND QUANTITY WENT TO ZERO. ALSO, HAD AILERON 2 AND RUDDER 2 FAIL IN FLIGHT. MX REMOVED AND REPLACED EDP 2 AND SERVICED HYD. OPS CHECKED MACH 2. (K)Oct 7, 2008 · N825MJ · Emb EMB145LR · Hydraulic Pump (Electric/Engine), MainSDR FDK2008F00012Connector · dirtyGALLEY EMERGENCY LIGHTS INOPERATIVE. MX CLEANED THE CONNECTOR. OPS CHECKED GOOD. (K)Sep 27, 2008 · N825MJ · Emb EMB145LR · Light System WiringSDR FDK2008F00005Battery · dischargedGALLEY EMERGENCY LIGHT INOP. MX REPLACED NR 2 EMERGENCY LIGHT BATTERY PACK ASSY, OPS CHECK GOOD. (K)Jul 15, 2008 · N825MJ · Emb EMB145LR · Emergency LightingSDR FDKA200805189Lamp · inoperativeFDM RON MCO - COCKPIT EMERGENCY LIGHT INOP. MX RELAMPED, OPS GOOD.May 4, 2008 · N825MJ · Emb EMB145LR · Emergency LightingSDR FDKA200804149Connector · not seatedFDM 6073 JFK-ORF (0855 PHX LCL). SERVICE DOOR EMERGENCY LIGHT OUT. MX RESEATED THE CONNECTOR AND OPS CHECKED.Apr 5, 2008 · N825MJ · Emb EMB145LR · Light System WiringSDR FDKA200803129Buttstrap · corrodedBUTT STRAP AT Y=479 AND FRAME 61 IS CORRODED OUT OF LIMITS. REMOVED AND REPLACED BUTT STRAP.Mar 24, 2008 · N825MJ · Emb EMB145LR · Fuselage Miscellaneous StructureSDR FDKA200803133Skin · dentedPASSENGER CABIN ESCAPE HATCH SKIN DENT. REPAIRED DOOR.Mar 24, 2008 · N825MJ · Emb EMB145LR · Emergency ExitsSDR FDKA200803132Seat Track · corrodedLEFT OUTBOARD SEAT TRACK AT FRAME 30 TO 36 IS CORRODED OUT OF LIMITS. REMOVED AND REPLACED SEAT TRACK (145-32606-003).Mar 24, 2008 · N825MJ · Emb EMB145LR · Fuselage, Seat/Cargo Attach FittingsSDR FDKA200803131Sill · corrodedRIGHT OUTBOARD FLOOR SILL AT FRAME 29 TO 35 IS CORRODED OUT OF LIMITS. REMOVED AND REPLACED FLOOR SILL.Mar 24, 2008 · N825MJ · Emb EMB145LR · Fuselage Miscellaneous StructureSDR FDKA200803130Seat Track · corrodedLEFT OUTBOARD SEAT TRACK AT FRAME 24 TO 30 IS CORRODED OUT OF LIMITS. REMOVED AND REPLACED SEAT TRACK.Mar 24, 2008 · N825MJ · Emb EMB145LR · Fuselage, Seat/Cargo Attach FittingsSDR FDKA200803128Rib · chafedTHE PREVIOUS REPAIR ON THE L/B UPPER RIB ON THE LT LOWER COWLING IS CHAFED. THE RIB HAS BEEN REMOVED AND REPLACED.Mar 22, 2008 · N825MJ · Emb EMB145LR · Nacelle/Pylon, Frame/Spar/RibSDR FDKA200803107Seal · leakingFDM 6031 - JFK- IAD (1638 PHX LCL) - LOUD NOISE FROM F/O'S SIDE WINDOW DURING DESCEND. MX RESECURED THE WINDOW SEAL AND LEAK CHECKED.Mar 12, 2008 · N825MJ · Emb EMB145LR · Flight Compartment WindowsSDR FDKA200802076Smoke Detector · malfunctionedFDM 6185 MCO-PNS (1545 PHX LCL) EN ROUTE TO PNS AIRCRAFT DIVERTED TO TLH DUE TO BAG SMOKE WARNING IN EICAS IN FLIGHT. MX REMOVED AND REPLACED SMOKE DETECTOR, SMOKE DETECTOR RELAY, AND FAN RELAY.Feb 21, 2008 · N825MJ · Emb EMB145LR · Smoke DetectionSDR FDKA200802073Smoke Detector · malfunctionedFDM 6152 MCO-GSO (1558 PHX LCL) EN ROUTE TO GSO AIRCRAFT DIVERTED TO SAV DUE TO BAG SMOKE WARNING ON EICAS IN FLIGHT. NO EVIDENCE OF FIRE WAS FOUND AND MX REMOVED AND REPLACED SMOKE DETECTOR AND BOTTLES.Feb 20, 2008 · N825MJ · Emb EMB145LR · Smoke DetectionSDR FDKA200802064Connector · looseFDM 6198 JFK. GALLEY/SERVICE DOOR EMERGENCY EXIT LIGHT OUT. MX RESECURED LOOSE CONNECTOR, OPS GOOD.Feb 17, 2008 · N825MJ · Emb EMB145LR · Light System WiringSDR FDKA200712428Switch · dirtyFDM FLT 6042 JFK-ROC (0839 PHX LCL) - SPOILER FAIL CAUTION. MX CLEANED SWITCHES, OPS GOOD.Dec 29, 2007 · N825MJ · Emb EMB145LR · Drag Control SystemSDR FDKA200710553Connector · corrodedFDM 6101 TLH (1240 PHX LCL) - EMERGENCY FLOOR PATH LIGHTING AT ROW 12 INOP. MX FOUND CORROSION AT CONNECTOR. CLEANED AND RE-SOLDERED.Oct 15, 2007 · N825MJ · Emb EMB145LR · Light System WiringSDR FDKA200710545Connector · looseFDM 9963 MCO - SPOILER FAIL EICAS MESSAGE. MX RESECURED SPOILER PROX SWITCH CONNECTOR AND APPLIED HEAT SHRINK.Oct 13, 2007 · N825MJ · Emb EMB145LR · Flight Control System WiringSDR FDKA200710546Proximity Switch · unknownFDM RON MCO - SPOILER FAIL DURING TEST FLIGHT. MX RIGGED LT GROUND SPOILER AND INSTALLED PROX SWITCH AND RT OB SPEED BRAKE HANDLE.Oct 13, 2007 · N825MJ · Emb EMB145LR · Drag Control SystemSDR FDKA200710543Proximity Sensor · out of adjustFDM RON MCO (1613 PHX LCL) - SPOILER FAIL MESSAGE IN FLIGHT. MX ADJUSTED INDICATION PROX SENSORS.Oct 11, 2007 · N825MJ · Emb EMB145LR · Drag Control SystemSDR FDKA200710539Control Unit · malfunctionedFRL RON TPA - SPOILER FAULT, SPOILER OPEN MESSAGE. REMOVED AND REPLACED SPOILER CONTROL UNIT.Oct 10, 2007 · N825MJ · Emb EMB145 · Drag Control SystemSDR FDKA200710537Proximity Switch · dirtyFDM 6018 PNS-TPA (1355 PHX LCL) - SPOILER FAIL CAUTION MESSAGE IN FLIGHT. MX CLEANED C/P ON PROX SW, PERFORMED OPS CHECK, OPS GOOD.Oct 9, 2007 · N825MJ · Emb EMB145LR · Drag Control SystemSDR FDKA200710538Control Unit · faultedFDM 6171 TPA-PNS (1732 PHX LCL) - SPOILER FAIL CAUTION MESSAGE IN FLIGHT. MX REMOVED AND REPLACED THE SPOILER CONTROL UNIT.Oct 9, 2007 · N825MJ · Emb EMB145LR · Drag Control SystemSDR FDKA200710529Proximity Switch · dirtyFDM RON JFK (1714 PHX LCL) - SPOILER FAIL CAUTION MESSAGE IN FLIGHT. MX CLEANED PROX SWITCHES, OPS CHECKED GOOD.Oct 7, 2007 · N825MJ · Emb EMB145LR · Drag Control SystemSDR FDKA200710527Proximity Switch · dirtyFDM 6089 JFK (0620 PHX LCL) - SPOILER FAIL CAUTION MESSAGE IN FLIGHT. MX CLEANED PROX SWITCHES. OPS GOOD.Oct 7, 2007 · N825MJ · Emb EMB145LR · Drag Control SystemSDR FDKA200710518Proximity Switch · malfunctionedFDM 6041 JFK (1554 PHX LCL) - SPOILER FAIL CAUTION MESSAGE IN FLIGHT. MX REMOVED AND REPLACED LT O/B SPOILER PROX SWITCH.Oct 3, 2007 · N825MJ · Emb EMB145LR · Drag Control SystemSDR FDKA200709457Control Unit · inoperativeFDM FLT RON MCO - PITCH TRIM MAIN AND STANDBY SYSTEM INOPERATIVE. MX REPLACED THE HSCU AND OPS CHECKED.Sep 9, 2007 · N825MJ · Emb EMB145LR · Elevator Tab Control SystemSDR FDKA200709451Trim System · inoperativeFFDM FLT 6174 SYR - PITCH TRIM INOP. MX RESET SYSTEM WITH CREW. NO FURTHER ACTION REQUIRED. OPS GOOD.Sep 7, 2007 · N825MJ · Emb EMB145LR · Elevator Tab Control SystemSDR FDKA200709491Frame · chafedRT LOWER ENGINE COWLING, THIRD FRAME FROM THE AFT END, IS CHAFED OUT OF LIMITS. REPAIRED THE DAMAGE.Sep 4, 2007 · N825MJ · Emb EMB145LR · Nacelle/Pylon, Frame/Spar/RibSDR FDKA200709492Structure · bentTHE RT ELEVATOR HAD DAMAGE FROM CONTACT WITH THE HANGAR DOOR. REMOVED AND REPLACED ELEVATOR.Sep 2, 2007 · N825MJ · Emb EMB145LR · Elevator StructureSDR FDKA200709488Panel · damagedPANEL 412CL HAS AN ELONGATED HOLE THAT IS BEYOND LIMITS. INSTALLED A DIMPLED WASHER OVER THE DAMAGE.Sep 2, 2007 · N825MJ · Emb EMB145LR · Nacelle/Pylon, Plate/SkinSDR FDKA200709487Frame · chafedTHE AFT FRAME ON THE LOWER ENGINE COWLING IS CHAFED OUT OF LIMITS. REMOVED AND REPLACED DAMAGED FRAME.Sep 1, 2007 · N825MJ · Emb EMB145LR · Nacelle/Pylon, Frame/Spar/RibSDR FDKA200708361Controller · odorFDM 6201 FLL-TLH (0528 PHX LCL) - DIVERT TO MCO DUE TO A STRONG ELECTRICAL BURNING ODOR WITH NO VISUAL SMOKE WHEN WINDSHIELD HEAT ON. MX INSPECTED WIRING FOR BURNED WIRES, NO DEFECTS FOUND. MX REMOVED AND REPLACED WINDSHIELD 2 HEAT CONTROLLER AND CONTACTOR, Aug 2, 2007 · N825MJ · Emb EMB145LR · Airfoil Anti/De-ice SystemSDR FDKA200706282Actuator · malfunctionedFDM 9964 MCO-FLL (1005 PHX LCL). PITCH TRIM MAIN INOP MESSAGE. MX REMOVED AND REPLACED HSA.Jun 15, 2007 · N825MJ · Emb EMB145LR · Stabilizer ActuatorSDR FDKA200706278Control Unit · malfunctionedFDM 6079 FLL-MCO (1658 PHX LCL). PITCH TRIM BACK UP SYSTEM INOPERATIVE. MX REMOVED AND REPLACED HSCU.Jun 15, 2007 · N825MJ · Emb EMB145LR · Stabilizer Control System
Back to N825MJ, cancelled Oct 22, 2015