N841HK, cancelled May 2, 2024
Service difficulty reports · 142
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N841HK' AND deregistration_id = 'N841HK-2024-05-02' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N841HK' AND deregistration_id = 'N841HK-2024-05-02' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR 4VAA20171211010Bleed Air Sys · failedAIRCRAFT AT GATE. AFTER APU BLEED AIR WAS SELECTED ON WITH CROSS BLEED VALVE OPEN, CREW IMMEDIATELY RECEIVED A CROSS BLEED VALVE FAIL MESSAGE. ONE MINUTE LATER THE BLEED APU LEAK MESSAGE APPEARED. CREW FOLLOWED PROCEDURES AND SHUT APU DOWN.
MAINTENANCE FOUNDSDR 4VAA20170708009Windshield · failedENROUTE AT FLT LEVEL 350, THE LEFT COCKPIT WINDSHIELD OUTER PANE SHATTERED WITH THE INTER PANE REMAINING INTACT. DECLARED AN EMERGENCY AND DIVERTED. LANDED WITHOUT FURTHER INCIDENT. AIRCRAFT HISTORY INDICATES LEFT WINDSHIELD WAS REPORTED AS LEAKING. MAINTESDR 4VAA20170528008Controller · failedDURING TAKEOFF ROLL, AT APPROXIMATELY 75 KTS, CREW RECEIVED A NR 2 PACK OVERHEAT MESSAGE. THE TAKEOFF WAS ABORTED AND AIRCRAFT RETURNED TO THE GATE. MAINTENANCE FOUND THE RIGHT AUTOMATIC TEMPERATURE CONTROLLER AT FAULT CAUSING SYSTEM TO PRODUCE ONLY FULL HOT SDR 4VAA20161230003Outflow Valve · failedAFTER REACHING CRUISE, CREW FELT A BUMP IN THE PRESSURIZATION & CABIN PRESSURE BEGAN TO RISE, DONNED OXYGEN MASKS & PERFORM ALL REQUIRED CHECKLISTS. AN EMERGENCY WAS DECLARED AND DESCENDED TO 10000 FT. CABIN ALTITUDE REACHED 15000 FT & PAX O2 MASKS DEPLOYED. SDR RAIA201508160004Plate · corrodedFRAME 18 PLATE HAS CORROSION. MAINTENANCE REPLACED THE FRAME PLATE.SDR RAIA201508160003Plate · corrodedFRAME 14 HAS CORROSION. REPLACED FRAME PLATESDR RAIA201507200001Bulb · inoperativeSERVICE DOOR EMERGENCY FLOOD LIGHT NR 2 IS INOPERATIVE. MAINTENANCE REPLACED THE BULB, OPS CHECKED GOOD.SDR RAIA201507190001Door · lack of lubeMAIN CABIN DOOR DIFFICULT TO OPEN DURING POST FLIGHT. MAINTENANCE CLEANED AND LUBED MAIN DOOR, OPS CHECK GOOD.SDR RAIA201506180002Light · inoperativeLEFT OVERWING EMERGENCY LIGHT NR 5 IS INOPERATIVE. MAINTENANCE REPLACED LIGHT, OPS CHECK GOOD.SDR RAIA201410220001Door · lack of lubeMAIN DOOR DIFFICULT TO OPEN OR CLOSE DURING POST FLIGHT. MAINTENANCE CLEANED AND LUBED MAIN PASSENGER DOOR SEALS, OPS CHECKED GOOD.SDR RAIA201410090001Anti-Ice Valve · inoperativeWING ANTI-ICE FAIL MESSAGE ON EICAS DURING CRUISE, RETURNED TO DEPARTURE. MAINTENANCE REPLACED LT WING ANTI ICE VALVE, OPS CHECK GOOD.SDR RAIA201409280001Bulb · inoperativeLEFT OVERWING EXTERIOR EMERGENCY EXIT LIGHT INOPERATIVE. MAINTENANCE REPLACED THE BULB, OPS CHECKED GOOD.SDR RAIA201409160001Door · lack of lubeMAIN CABIN DOOR HARD TO OPEN DURING POST FLIGHT. MAINTENANCE INSPECTED AND LUBED MAIN DOOR AND OPS CHECKED GOOD.SDR RAIA201407040001Pump · leakingDURING LANDING, LOSS OF HYDRAULIC FLUID FROM SYSTEM 2, FOLLOWED BY HYD 2 LOW QUANTITY, RUDDER SYS 2 INOPERATIVE, AILERON SYS 2 INOPERATIVE MESSAGE. MAINTENANCE INSPECTED AND REPLACED NR 2 ENGINE DRIVEN HYD PUMP, OPS AND LEAK CHECK GOOD.SDR RAIA201405250002Bulb · inoperativeCEILING EMERGENCY EXIT LIGHT IN GALLEY IS INOPERATIVE. MAINTENANCE REPLACED BULB AND OPS CHECKED GOOD.SDR RAIA201405250001Bulb · inoperativeCEILING EMERGENCY EXIT LIGHT AT ROW 3 IS INOPERATIVE. MAINTENANCE REPLACED BULB AND OPS CHECKED GOOD.SDR RAIA201405080001Light · inoperativeEMERGENCY LIGHT STRIP AT ROW 3 AND 4 INOPERATIVE. MAINTENANCE REPLACED EMERGENCY LIGHT STRIP, OPS CHECKED GOOD.SDR RAIA201404290001Rivet · corrodedTWO RIVETS HAVE CORROSION ON LOWER FUSELAGE BY FRAME 33. MAINTENANCE REPLACED TWO RIVETS.SDR RAIA201404270005Channel · corrodedLOWER SERVICE DOOR CHANNEL, DOOR FRAME HAS CORROSION. MAINTENANCRE REPLACED LOWER SERVICE DOOR FRAME.SDR RAIA201404270004Door Sill · corrodedFORWARD SERVICE DOOR SILL HAS CORROSION. MAINTENANCE REPLACED FORWARD SERVICE DOOR SILL.SDR RAIA201404270003Floor Support · corrodedLT OMEGA BEAM HAS CORROSION AT FR20. MAINTENANCE REPLACED LT OMEGA BEAM AT FR20.SDR RAIA201404270002Support · corrodedCENTER RAMP SUPPORT HAS CORROSION AT FRAME 20. MAINTENANCE REPLACED CENTER RAMP SUPPORT.SDR RAIA201404270001Gusset · corrodedCENTER GUSSET HAS CORROSION BETWEEN FRAMES 20 AND 22. MAINTENANCE REPLACED CENTER GUSSET.SDR RAIA201404260002Housing · corrodedLAVATORY DRAIN CUP HOUSING CORRODED. MAINTENANCE REPLACED LAVATORY DRAIN CUP HOUSING.SDR RAIA201404260001Door Sill · corrodedCARGO BAY SILL PLATE HAS CORROSION. MAINTENANCE REPLACED CARGO BAY SILL PLATE.SDR RAIA201404010001Unknown · odorF/A REPORTED SMOKE AND BURNING ODOR AT ROW 19.SDR RAIA201309190001Bulb · inoperativeRIGHT AFT WING/FUSELAGE FAIRING EXTERIOR FLOOD LIGHT INOPERATIVE. MX REPLACED RIGHT AFT WING/FUSELAGE FAIRING LIGHT AND OPS CHECK GOOD.SDR RAIA201307110001Bulb · inoperativeLEFT AFT WING TO FUSELAGE FAIRING EXTERIOR FLOOD LIGHT INOPERATIVE. MX REPLACED FLOOD LIGHT AND OPS CHECKED GOOD.SDR RAIA201307100001Bulb · inoperativeCABIN EMERGENCY LIGHTS 8 AND 14 FOUND INOPERATIVE DURING PREFLIGHT. FERRIED ACFT AND MX REPLACED LIGHTS AND OPS CHECKED GOOD.SDR RAIA201302270001Switch · contaminatedAFTER NORMAL AIRCRAFT POWER DOWN SEVERAL EMERGENCY LIGHTS STAYED ON IN THE AFT CABIN, OVERWING EMERGENCY LIGHT AND MAIN CABIN STAIR LIGHTS. MAINTENANCE INSPECTED CLEANED THE EMERGENCY LIGHT SWITCH. SYSTEM OPS CHECKED GOOD.SDR RAIA201212300001Light · inoperativeDURING SCHEDULED MAINTENANCE THE LEFT OVERWING EMERGENCY EXIT LIGHT WAS INOP. MAINTENANCE INSPECTED AND REMOVED AND REPLACED THE LEFT EMERGENCY EXIT LIGHT. SYSTEM OPS CHECKED GOOD.SDR RAIA201208270001Battery · dischargedDURING PREFLIGHT, THE FLIGHT CREW FOUND THE EMERGENCY LIGHTS SYSTEM WAS LEFT ACTIVE FROM PREVIOUS FLIGHT AND EXTINGUISHED. MAINTENANCE INSPECTED AND FOUND TO BE SAFE FOR ONE-WAY FERRY FLIGHT TO KSTL. IN KSTL, MAINTENANCE REMOVED AND REPLACED ALL EMERGENCY LISDR RAIA201102140002Handle · brokenDURING POST FLIGHT INSPECTION THE FLIGHT CREW REPORTED THE PASSENGER DOOR HANDLE WAS HANGING UP WHEN TRYING TO OPEN FROM THE INSIDE. MAINTENANCE INSPECTED AND FOUND THE PASSENGER DOOR HANDLE BROKEN. MAINTENANCE REMOVED AND REPLACED THE PASSENGER DOOR HANDLE.SDR RAIA201102140001Light · inoperativeDURING POST FLIGHT INSPECTION THE FLIGHT CREW REPORTED THE EMERGENCY LIGHT ABOVE THE PASSENGER DOOR WAS INOP. MAINTENANCE INSPECTED AND RELAMPED THE EMERGENCY LIGHT ABOVE THE PASSENGER DOOR. SYSTEM OPS CHECKED GOOD.SDR RAIA201102110001Connector · not seatedDURING PRE-FLIGHT INSPECTION THE FLIGHT CREW REPORTED THE EMERGENCY LIGHTS AT 17F - 17H, 16C, 16D AND 18A INOP. MAINTENANCE INSPECTED AND RE-SEATED THE CONNECTOR. SYSTEM OPS CHECKED GOOD.SDR V0XR201101180003Sill · corrodedCARGO ENTRY SILL AT FR 65-68 IS CORRODED BEYOND LIMITS. R & R SILL. W/C 1122SDR V0XR201101180002Shear Tie · corroded(V0XR) SHEAR CLIP AT FR 68 STGR 9L-18L IS CORRODED BEYOND LIMITS. R & R SHEAR CLIP. W/C 1125.SDR V0XR201101180001Shear Tie · corrodedSHEAR CLIP AT FR 65 IS CORRODED BEYOND LIMITS. R & R SHEAR CLIP. W/C 1124SDR V0XR201101140001Support · broken(V0XR) FLIGHT CABLE STANDOFF SUPPORT BROKEN AT STA 6938. R & R SUPPORT. W/C 1128SDR V0XR201101130007Profile · cracked(V0XR) FWD LOWER CORNER OF CARGO FLOOR IS DAMAGED. R & R PROFILE. W/C 8011SDR V0XR201101130006Sill · cracked(V0XR) RT CARGO FLOOR SILL BETWEEN FR 68-71 IS CRACKED. R & R SILL. W/C 2194SDR V0XR201101130005Seat Track · corroded(V0XR) CORRECTION SEAT TRACK POS A FR 24-30 IS CORRODED BEYOND LIMITS. R & R SEAT TRACK. W/C 2146SDR V0XR201101130004Seat Track · crackedSEAT TRACK POS B FR 18-24 IS CORRODED BEYOND LIMITS. R & R SEAT TRACK. W/C 2139.SDR V0XR201101130003Support · cracked(V0XR) CARGO DOOR CABLE TORSION RODS BRACKET CRACKED. R & R SUPPORT. W/C 2072SDR V0XR201101130002Sill · corroded(V0XR) LT SILL AT FR 36-41 IS CORRODED BEYOND LIMITS. R & R SILL. W/C 1078.SDR V0XR201101130001Support · crackedLT UPPER WING TO BODY FAIRING SUPPORT STRIP STA 16143.5-17445.0 IS CRACKED. R & R STRIP. W/C 1054.SDR V0XR2011011200022Seat Track · corrodedSEAT TRACK POS C AT FR 30-36 IS CORRODED BEYOND LIMITS. R & R SEAT TRACK.SDR V0XR2011011200019Partition · corrodedLT LOWER PARTITIAN AT FR 61 IS CORRODED BEYOND LIMITS. R & R PARTITIAN.SDR V0XR2011011200018Channel · corrodedRT HAT BEAM AT FR 58-62 IS CORRODED BEYOND LIMITS. R & R BEAM HAT.SDR V0XR2011011200017Seat Track · corrodedSEAT TRACK POS D AT FR 47-52 IS CORRODED BEYOND LIMITS. R & R SEAT TRACK.
Back to N841HK, cancelled May 2, 2024