N854HK, cancelled Jun 1, 2023
Service difficulty reports · 27
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N854HK' AND deregistration_id = 'N854HK-2023-06-01' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N854HK' AND deregistration_id = 'N854HK-2023-06-01' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR RAIA201602110001Light · inoperativeCEILING EMERGENCY EXIT LIGHT AT PASSENGER DOOR ENTRANCE, LIGHT NR 13 IS INOPERATIVE. R & R CEILING EMERGENCY EXIT LIGHT AT PASSENGER DOOR ENTRANCE, LIGHT NR 13. OPS CHECKED GOOD.SDR RAIA201601310001Light · sparksF/A REPORTED SMOKE IN THE CABIN AT THE GATE. OBSERVED FLASHING AROUND OVERHEAD OF SEAT 6D.SDR RAIA201507180001Bulb · inoperativeEMERGENCY EXIT LIGHT IN CEILING OF COCKPIT, NR 7, IS INOPERATIVE. MAINTENANCE REPLACED BULB, OPS CHECKED GOOD.SDR RAIA201505210001Conditioner · inoperativeTANK 1 FUEL INDICATION WENT ZERO AFTER DEPARTURE, RETURNED TO BLOCK. MAINTENANCE REPLACED FUEL CONDITIONING UNIT, OPS CHECK GOOD.SDR RAIA201502080001Bulb · inoperativeEMERGENCY EXIT LIGHT IN COCKPIT, NR 7, IS INOPERATIVE. MAINTENANCE REPLACED THE BULB, OPS CHECKED GOOD.SDR RAIA201412090001Bellcrank · out of positionMAIN CABIN DOOR WILL NOT OPEN FROM INSIDE, HANDLE ONLY MOVES 1/3 OF THE WAY. DURING POST FLIGHT. MAINTENANCE INSPECTED AND FOUND MAIN CABIN DOOR INTERNAL HANDLE BELLCRANK OUT OF POSITION, REPOSITIONED THE BELL CRANK, OPS CHECK GOOD.SDR RAIA201408160001Smoke Detector · no testLAVATORY SMOKE DETECTION SYS WILL NOT TEST FROM GALLEY CONTROL PANEL. MAINTENANCE INSPECTED AND REPLACED THE LAVATORY SMOKE DETECTOR SENSOR, OPS CHECKED GOOD.SDR RAIA201407080003Floor Support · corrodedLEFT FLOOR SUPPORT AT FRAME 61 CORRODED. MAINTENANCE REPLACED THE FLOOR SUPPORT.SDR RAIA201407080002Floor Support · corrodedCENTER OMEGA BEAM HAS CORROSION AROUND FASTENER HOLE FWD OF FRAME 61. MAINTENANCE REPLACED OMEGA BEAM.SDR RAIA201407080001Profile · corrodedCORROSION FOUND ON PROFILE OF LT OMEGA BEAM FWD OF FRAME 20. MAINTENANCE REPLACED PROFILE ON LT OMEGA BEAM FWD OF FRAME 20.SDR RAIA201407060003Channel · corrodedCARGO DOOR ZEE CHANNEL AT FRAME 68 CORRODED. MAINTENANCE REPLACED CARGO DOOR ZEE CHANNEL.SDR RAIA201407070002Gusset · corrodedRIGHT GUSSET FWD OF FRAME 61 HAS CORROSION. MAINTENANCE REPLACED RT GUSSET FWD OF FRAME 61.SDR RAIA201407070001Gusset · corrodedCENTER GUSSET FWD OF FRAME 61 HAS CORROSION. MAINTENANCE REPLACED CENTER GUSSET FWD OF FRAME 61.SDR RAIA201407060002Tee Fitting · corrodedTEE FITTING AFT OF CARGO DOOR SILL ZEE CHANNEL CORRODED. MAINTENANCE REPLACED TEE FITTING.SDR RAIA201407050003Channel · corrodedCARGO DOOR BOTTOM FRAME CHANNEL CORRODED. MAINTENANCE REPLACED CARGO DOOR BOTTOM FRAME CHANNEL.SDR RAIA201407050002Floor Support · corrodedLEFT OMEGA BEAM CORRODED AT FRAME 20. MAINTENANCE REPLACED OMEGA BEAM.SDR RAIA201407040003Bonding Strap · corrodedFECU ACCESS PANEL BONDING STRIPS ARE CORRODED. MAINTENANCE REMOVED CORROSION AND REINSTALLED FECU PANEL.SDR RAIA201407040002Bonding Strap · corrodedLEFT UPPER AND LOWER AILERON SHROUD BONDING STRAPS ARE CORRODED. MAINTENANCE REPLACED BONDING STRAPS, OPS CHECK GOOD.SDR RAIA201402140001Handset · failedFWD F/A HANDSET SMOKING DURING TAXI TO GATE. MAINTENANCE REPLACED FWD F/A HANDSET AND OPS CHECK GOOD.SDR RAIA201308150001Flashlight · inoperativeAFT CABIN EMERGENCY FLASHLIGHT INOPERATIVE. MX REPLACED FLASHLIGHT AND OPS CHECKED GOOD.SDR RAIA201306260001O-Ring · wornBLEED 1 LEAK IN FLIGHT. CREW RETURNED ACFT FROM FLIGHT. MX REPLACED O-RINGS AT JOINTS 25, 23, 19 AND 17, OPS CHECKED GOOD.SDR RAIA201306190001Wire · damagedCABIN FLOOR PROXIMITY ELECTROLUMINESCENT EMERGENCY LIGHT INOPERATIVE AT ROW 18. MX INSPECTED AND REPAIRED WIRES AND OPS CHECKED GOOD.SDR RAIA201306130001Engine · shutdownDURING CRUISE, FLIGHT CREW RECEIVED A NR 2 ENGINE TEMPERATURE SPIKE. PULLED THROTTLE BACK AND ENGINE AUTO SHUTDOWN. DIVERTED. MX INSPECTED AND R & R NR 2 ENGINE. OPS CHECKED GOOD.SDR RAIA201304080001Support · corrodedDURING SCHEDULED MAINTENANCE THE TOILET WASTE VALVE SUPPORT WAS FOUND TO BE CORRODED. MAINTENANCE REMOVED AND REPLACED THE TOILET WASTE VALVE SUPPORT.SDR RAIA201304070001Floor Support · corrodedDURING SCHEDULED MAINTENANCE THE LEFT DIGITAL PLATE ON BEAM Y-479 AT FRAMES 19-24 WAS FOUND TO BE CORRODED. MAINTENANCE REMOVED AND REPLACED THE LEFT DIGITAL PLATE ON BEAM Y-479 AT FRAMES 19-24.SDR RAIA201304040002Cup · corrodedDURING SCHEDULED MAINTENANCE THE LAV WASTE CUP ASSY WAS FOUND TO BE CORRODED. MAINTENANCE REMOVED AND REPLACED THE LAV WASTE CUP ASSY.SDR RAIA201304040001Structure · corrodedDURING SCHEDULED MAINTENANCE THE PASSENGER DOOR U SHAPES WERE FOUND TO BE CORRODED. MAINTENANCE REMOVED AND REPLACED THE U SHAPES.