N855AE, cancelled Feb 6, 2024
Service difficulty reports · 80
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N855AE' AND deregistration_id = 'N855AE-2024-02-06' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N855AE' AND deregistration_id = 'N855AE-2024-02-06' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR SIMA202001287003Strobe · inoperativeRH WING STROBE LIGHT INOP-C/A-REMOVED AND REPLACED RH WING STROBE LIGHT IAW AMM 33-47-03 - OPS CHK GOODSDR SIMA20190916001Skin · dentedSUPPLEMENTAL FUSELAGE DENTED BETWEEN FR1 AND FR3. C/A-REPLACED RT FF1 SKIN PANEL IAW SRM 51-40-02 AND 51-21-01.SDR SIMA201908087002Cradle · crackedFA'S FLASHLIGHT BASE CRACKED-C/A-RAR FLIGHT ATTENDANTS FLASHLIGHT BASE IAW EMB AMM 33-50-16-000-801-A & 33-50-16-400-801-A OPC GOOD AT THIS TIME NO FURHTER DEFEDCTS NOTED ENDSDR SIMA201906187003Inverter · inoperativeCABIN RH EMERGENCY EXIT IDENTIFIER INOPERATIVE. REMOVED AND REPLACED EMERGENCY LIGHT DC/AC INVERTER #5 IAW AMM 33-50-11. EMERGENCY LIGHT OPERATIONAL CHECK GOOD.SDR SIMA20190516001Light · inoperativeCOCKPIT CEILING EMERGENCY LIGHT INOP. C/A-RELAMPED COCKPIT CEILING EMERGENCY LIGHT OPC GOOD AMM 35-50-00.SDR SIMA20190206003Battery · dischargedBOTH LT AND RT AFT OVERWING EXTERIOR EMERGENCY LIGHTS FAILED FUNCTIONAL CHECK IAW MTX WC 33-700-17. REMOVED AND REPLACED EMERGENCY LIGHT CHARGER AND BATTERY AT POSITION NR 4 IAW MTX WC 33-700-19, OPC GOOD IAW MTX WC 33-700-17. BATTERY CHARGER ASSY 11-0049 S/NSDR SIMA20190120004Battery · dischargedFOUND EXTERNAL EMERGENCY LIGHTS ABOVE WING ON RT & LT INOP. C/A-REMOVED AND REPLACED BATTERY & BATTERY POWER SUPPLY IAW AMM 33-50-04. OPC GOOD. NO FURTHER DEFECTS NOTED AT THIS TIME. BATTERY CHARGER ASSY P/N 11-0049 S/N 18121.SDR SIMA201812264001Oil System · within limitsHIGH SPEED ABORT TAKEOFF AT 80KTS DUE TO #2 ENGINE OIL PRESSURE BEING IN THE CAUTION RANGE IN TAKE OFF POWER. PRESSURE WAS ABOUT 150-155 PSI AFTER ABORT ALL INDICATION WAS IN TH GREEN.CORRECTIVE ACTION PERFORMED POWER ENGINE WITH CREW OIL PRESSURE INDICATION MSDR SIMA201812210003Flashlight · inoperativeMEL 25-53 AUTH # 120588-C LG PG 4420629-1 AFT EMERGENCY FLASH LIGHT NOT CHARGING-C/A-PERFORMED FUCTIONAL TEST OF AFT F/A FLASH LIGHT IAW E-140 AMM 33-51-01 AND CHECKS GOOD MEL RESTOREDSDR SIMA20181214001Flashlight · inoperativeCABIN AFT EMER FLASHLIGHT RED CHARGING LIGHT INOP. REMOVED AND REPLACED FLASHLIGHT AND HOLDER ASSY IAW AMM 33-50-16 NO FIX.SDR SIMA20181214002Battery · dischargedLT AND RT EXTERNAL OVERWING EMERGENCY LIGHTS INOP. REMOVED AND REPLACED #4 EMERGENCY BATTERY IAW AMM 33-50-04 AND ETN-EM-33-020R1 OPC GOOD.SDR SIMA201811276005Display · malfunctionedISIS WENT DARK, THEN RE-APPEARED WITH WHITE "ATT" INSIDE RED BOX. NO ATTITUDE INFORMATION PRESENTED. OTHER INSTRUMENTATION MATCHED PRIMARY DISPLAYS QRH PROC APPLIED, NO EFFECT. EMERGENCY DECLARED.-C/A-ACCOMPLISHED FIM TASK 34-1-00-810-801-A STEPS 1 &3. DISCRESDR SIMA20181016001Light · inoperativeROW 11 CEILING EMERGENCY LT INOP. REMOVED AND REPLACED ROW 11 CEILING EMERGENCY LIGHT BULB IAW AMM 33-50-08-000-801-A AND 33-50-08-400-801-A OPC GOOD END.SDR SIMA201810110001Electronic Unit · failedAFTER TAKEOFF FO CALLED FOR GEAR UP. EICAS INDICATION WENT FROM DOWN (GREEN) TO UP (WHITE) WITH NO INTRANSIT. AFTER REACHING 10,000 CA LOOKED AT RMU BACKUP AND IT SHOWED GEAR DOWN AND LOCKED. EICAS SHOWING GEAR UP. CREW RAN ABNORMAL LANDING GEAR EXTENSION. CRESDR SIMA2018100502005Unknown · odorBURNING PLASTIC SMELL-C/A-PERFORMED ETN-EM-72-034 NO BURNING PLASTIC SMELL NOTED TEST PASSED WITH ODOR ATTRIBUTES NR 1SDR SIMA201808274002Light · inoperativeEMERGENCEY LIGHT ON THE PAX DOOR WAS INOPERATIVE. REMOVED AND REPLACED THE EMERGENCY LIGHT ASSY IAW AMM 33-50-10. OPS CHECKED GOOD. NO DEFECTS NOTED.SDR SIMA201808274001Lamp · inoperativeLEFT AFT EXTERIOR EMERGENCY LIGHT WAS INOPERATIVE. R & R THE LAMP IAW AMM 33-50-10. OPS CHECKED GOOD. NO DEFECTS NOTED.SDR SIMA201805295002Light · inoperativeROWS 5 & 6A EMERGENCY LIGHT WAS INOPERATIVE. R & R THE EMERGENCY LIGHT IAW AMM 33-50-12, OPS CHECKED GOOD.SDR SIMA20171110002Charger · inoperativeNR 4 AND 5 EMERGENCY LIGHTS INOPERATIVE. REMOVED AND REPLACED THE NR 3 BATTERY AND CHARGER IAW AMM 33-50-04. OPS CHECKED GOOD.SDR SIMA20171104001Floor Support · corrodedLEFT OMEGA BEAM CORRODED ON THE SIDE WALL, FRAMES 22 - 23. REPAIRED IAW ERS-EM-53MR-2985.SDR SIMA20171031005Floor Support · corrodedLEFT OMEGA BEAM CORRODED AT AND AROUND THE CROSSBEAM, FRAMES 57 - 59. REPAIRED IAW EO EM-53MR-1518R3, PART A.SDR SIMA20171031004Skin · chafedRUDDER LEADING EDGE CHAFED. ACCOMPLISHED A REPAIR TO THE RUDDER LEADING EDGE IAW ERS-EM-55MR-584.SDR SIMA20171031003Floor Support · corrodedCENTER OMEGA BEAM CORRODED FRAMES 56 - 59. REPAIRED IAW EO EM-53MR-1518R3, PART B.SDR SIMA20171028004Attach Fitting · wornFOUND RT AILERON ACTUATOR ATTACH FITTING BUSHING HOLES TO BE WORN BEYOND LIMITS. REPLACED THE ATTACH FITTING IAW EO EM-27MR-112.SDR SIMA20171028003Structure · corrodedAFT AVIONICS DOOR CORRODED UNDER THE FWD LOWER GUIDE. ACCOMPLISHED A PERMANENT REPAIR IAW ERS-EM-52MR-818SDR SIMA20171028002Door Sill · corrodedSERVICE DOOR LOWER CENTER SILL CORRODED. REMOVED AND REPLACED THE DOOR SILL IAW SRM 51-40-02.SDR SIMA20171025005Retainer · corrodedCO-PILOT`S WINDSHIELD OUTER RETAINER HAS CORROSION ON THE BOTTOM. WORKED THE AREA, FOUND THE RETAINER TO BE WITHIN ALLOWABLE LIMITS IAW ERS-EM-5600-107.SDR SIMA20171023003Frame · crackedFRAME 23 CRACKED BETWEEN STRINGERS 15R - 16R. ACCOMPLISHED A SPLICE REPAIR IAW EO EM-53MR-1808.SDR SIMA20170918009Frame · corrodedFRAME 65 CORRODED AT STRINGER 16L. REPAIRED THE FRAME IAW ERS-EM-53MR-2982.SDR SIMA20170918011Structure · corrodedLATERAL L SHAPE CORRODED AT STRINGER 16L.REPAIRED THE LATERAL L SHAPE IAW ERS-EM-53MR-2982.SDR SIMA20170918010Beam · corrodedCENTER AISLE BEAM CORRODED AND CHAFED BETWEEN FRAMES 37-38. REMOVED AND REPLACED THE BEAM IAW SRM 51-40-02.SDR SIMA20170918008Crossbeam · corrodedFRAME 20 CENTER AISLE CROSSBEAM CORRODED. REMOVED AND REPLACED THE CROSSBEAM IAW SRM 51-40-02.SDR SIMA20150831006Light · inoperativeNUMBER 1 & NUMBER 8 EMER LIGHT STRIPS ARE INOPERATIVE. R & R NR 1 & NR 8 EMER LIGHT STRIP IAW AMM 33-50-12. OPERATIONS CHECKED GOOD. FLOOR PROXIMITY LIGHT STRIP PN 6690-3 POSITION 1.SDR SIMA20150730001Handle · defectiveFLIGHT ATTENDANT REPORTS MAIN PASSENGER DOOR DIFFICULT TO OPEN & CLOSE PROPERLY. INSTALLED & INDEXED MAIN CABIN DOOR HANDLE IAW 52-11-01.SDR SIMA20150720003Door · lack of lubePREVIOUS CREW REPORTED PAX DOOR HARD TO OPEN. LUBRICATED MAIN PAX DOOR IAW AMM 52-18-00. OPERATIONS CHECKED GOOD.SDR SIMA20150717003Wire · brokenEMERGENCY FLOOR PATH LIGHTS AT SEATS 15 & 16 HAVE BROKEN WIRES. REPAIRED IAW WM 33-50-50 & SWPM 20-21-00. OPS CHECKED GOOD IAW AMM 33-50-12.SDR SIMA20150706001Roller · lack of lubeFLIGHT ATTENDANT ADVISES MAIN CABIN DOOR HANDLE HARD TO OPEN. CLEANED & LUBED MAIN PAX DOOR ROLLERS AS REQUIRED. DOOR OPENS & CLOSES NORMALLY WITH NO DEFECTS NOTED. REF MM 52-18-00.SDR SIMA20150610002Door · out of adjustMAIN CABIN DOOR IS DIFFICULT TO OPEN & CLOSE. PERFORMED & ADJUSTED PAX MAIN DOOR IAW AMM 52-18-00 TO REDUCE AVERAGE MAX LOAD OF THE INTERNAL HANDLE PULL TEST TO A VALUE LESS THAN 45 LBS ON OR BEFORE 200 FC ETN EM 52-029.SDR SIMA20150528004Roller · lack of lubeFLIGHT ATTENDANT REPORTS MAIN PAX DOOR HARD TO OPEN & CLOSE. TRANSFERRED TO NRWC 855-DFW-01910. LUBED MAIN DOOR FRAME ROLLERS IAW AMM 53-21-02. ALSO LUBED BOTH MAIN DOOR & FRAME SEALS. OPERATIONS CHECKED GOOD IAW AMM 52-18-00.SDR SIMA20150526002Light · inoperativeSERVICE DOOR EMER LIGHT INOPERATIVE. R & R LIGHT BULB AT SERVICE DOOR EMER LIGHT IAW AMM 33-50-10. OPERATIONS CHECKED GOOD.SDR SIMA20150518004Door · out of adjustMAIN CABIN DOOR DIFFICULT TO OPEN. TRANSFERRED TO NRWC 855-ORD-01906. ADJUSTED ROLLERS, LOWER GUIDES & UPPER & LOWER BARS IAW AMM 52-18-00-820-805 & AMM 52-18-00-820-806. OPERATIONS CHECKED IAW AMM 52-18-00-820-001. OPERATIONS CHECKED GOOD. REF NRWC 855-OSDR SIMA20150512005Guide · defectiveMAIN DOOR HANDLE VERY HARD TO OPEN & CLOSE. R & R ALL FOUR GUIDES IAW AMM 52-18-00. ADJUSTED UPPER & LOWER BARS IAW AMM 52-18-00. OPERATIONS CHECKED GOOD.SDR SIMA20150512001Door · obstructedMAIN DOOR VERY HARD TO OPEN & CLOSE. REMOVED DEBRIS & OPERATIONS CHECK DOOR IAW AMM 52-00-00. OPERATIONS CHECKED GOOD.SDR SIMA20150508003Mechanism · lack of lubeMAIN CABIN DOOR HARD TO OPERATE. LUBRICATION OF MAIN DOOR & LOCKING MECHANISM IAW AMM 52-11-00-PAGE 301.SDR SIMA20150112004Light · inoperativeRIGHT FWD EXTERNAL EMER LIGHT INOPERATIVE. R & R RT FWD EXTERNAL EMER LIGHT ASSEMBLY IAW AMM 33-50-10. OPERATIONS CHECKED GOOD.SDR SIMA20141127002Charger · inoperativeRIGHT & LEFT REAR FUSELAGE EXTERNAL EMER LIGHTS INOPERATIVE. R & R NR 4 EMER LIGHT BATTERY CHARGER ASSEMBLY IAW AMM 33-50-04. OPERATIONS CHECKED GOOD.SDR SIMA20141123010Battery · dischargedBOTH LT & RT OVERWING EMER LIGHT INOPERATIVE. R & R BATTERY & POWER SUPPLY NR 4 IAW AMM 33-50-04. OPERATIONS CHECKED GOOD. BATTERY CHARGER ASSEMBLY PN 11-0049 & SN 14336.SDR SIMA20140928001Radar · failedRADAR WAS TURNED ON INFLIGHT & AMBER WX WAS DISPLAYED ON PFD, WHEN TESTED RADAR FAIL WAS DISPLAYED WITH CODE 11. R & R WX RADAR ASSEMBLY IAW AMM 34-42-01. OPERATIONS CHECKED GOOD.SDR SIMA20140915003Flashlight · inoperativeCAPTAIN`S COCKPIT FLASHLIGHT RED LIGHT NOT ON, FOR RECHARGING. R & R CAPTAIN`S COCKPIT FLASHLIGHT AS REQUIRED.SDR SIMA20140730001Manifold · faultyCLIMBING OUT IN ICING CONDITION STAB ANTI-ICE FAIL ON EICAS. FOLLOWED AOM CHECKLIST & WAS NOT ABLE TO RESTORE SYS. R & R HORIZONTAL STAB SWITCH MANIFOLD IAW AMM 30-12-14. PERFORMED OPERATIONAL CHECK OF ANTI-ICING SYS IAW AMM 30-00-00-700-802A. OPERATIONS C
Back to N855AE, cancelled Feb 6, 2024