N855HK, cancelled Feb 10, 2024
Service difficulty reports · 35
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N855HK' AND deregistration_id = 'N855HK-2024-02-10' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N855HK' AND deregistration_id = 'N855HK-2024-02-10' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR RAIA201604240001Seal · leakingMAIN CABIN DOOR SEAL EXTREMELY LOUD ON CLIMB OUT. REPAIRED LEAK ON AFT SIDE LOWER PASSENGER DOOR. OPS CHECK GOOD.SDR RAIA201604140001Bulb · inoperativeRIGHT AFT WING, FUSLAGE FAIRING EXTERIOR FLOOD LIGHT, NR 6 INOPERATIVE. R & R RT AFT WING/FUSLAGE FAIRING EXTERIOR FLOOD LIGHT NR 6 BULB. OPS CHECKED GOOD.SDR RAIA201603210003Indicator · tumblesISIS TUMBLING WITH RED ATT FLAG, RETURNED TO BLOCK. MAINTENANCE REPLACE ISIS, OPS CHECK GOOD.SDR RAIA201603100001Seal · wornBLEED 2 LEAK. R & R BLEED SEALS. OPS AND LEAK CHECK GOOD.SDR RAIA201602040001Bulb · inoperativeAFT CEILING AISLE FLOOD LIGHT 16D IS INOPERATIVE. R & R AFT CEILING AISLE FLOOD LIGHT BULB. OPS CHECK GOOD.SDR RAIA201601200001Cabin Pressure · malfunctionedDECLARED EMERGENCY AT VERY BEGINNING OF DECENT DUE TO CABIN ALTITUDE DROPPING TO 9100 FT WHILE FLYING AT 32000 FT. CABIN ALTITUDE AND ACTUAL ALTITUDE MATCH AT 13500 FT.SDR RAIA201510240002Stop · inoperativeEMERGENCY EXIT ROW TRAY TABLE 18D STOPS INOPERATIVE. ADJUSTED TRAY TABLE STOP AT 18D. OPS CHECK GOOD.SDR RAIA201507300002Light · inoperativeRT EXTERIOR OVERWING EMERGENCY EXIT LIGHT, LIGHT NR 6 IS INOPERATIVE. R & R EMERGENCY OVERWING EXIT LIGHT NR 6. OPS CHECKED GOOD.SDR RAIA20150731001Light · inoperativeLT EXTERIOR OVERWING EMERGENCY EXIT LIGHT, NR 5, IS INOPERATIVE. R & R OVERWING EMERGENCY EXIT LIGHT ASSY. OPS CHECKED GOOD.SDR RAIA201507060002Light · inoperativeRIGHT AFT OVERWING EMERGENCY LIGHT NR 6 FOUND INOPERATIVE. MAINTENANCE REPLACED THE LIGHT, OPS CHECKED GOOD.SDR RAIA201507060001Light · inoperativeLEFT AFT OVERWING EMERGENCY LIGHT NR 5 INOPERATIVE. MAINTENANCE REPLACED LIGHT, OPS CHECKED GOOD.SDR RAIA201506290002Light · inoperativeRIGHT OVERWING EMERGENCY EXIT LIGHT NR 6 IS INOPERATIVE. MAINTENANCE REPLACED LIGHT, OPS CHECKED GOOD.SDR RAIA201506290001Light · inoperativeTHE LEFT OVERWING EXIT EMERGENCY LIGHT NR 5 IS INOPERATIVE. MAINTENANCE REPLACED THE LIGHT, OPS CHECKED GOOD.SDR RAIA201505230002Bulb · inoperativeRIGHT OVERWING EXTERIOR EMERGENCY EXIT LIGHT NR 6 INOPERATIVE. MAINTENANCE REPLACED BULB, OPS CHECK GOOD.SDR RAIA201505230001Bulb · inoperativeLEFT OVERWING EXTERIOR EMERGENCY LIGHT NR 5 INOPERATIVE. MAINTENANCE REPLACED BULB, OPS CHECKED GOOD.SDR RAIA201501290001Bulb · inoperativeLEFT OVERWING EXTERIOR EMERGENCY LIGHT IS INOPERATIVE. MAINTENANCE INSPECTED AND REPLACED THE BULB, OPS CHECKED GOOD.SDR RAIA201501020002Bulb · inoperativeLEFT EXTERIOR EMERGENCY EXIT LIGHT, FWD OF WING IS INOPERATIVE. MAINTENANCE REPLACED BULB, OPS CHECKED GOOD.SDR RAIA201409060001Light · inoperativeEMERGENCY EXIT FLOOD LIGHT AT 18A IS INOPERATIVE. MAINTENANCE REPLACED FLOOD LIGHT, OPS CHECKED GOOD.SDR RAIA201408210001Acm · failedSMOKE IN COCKPIT WITH ELECTRICAL ODOR DURING CRUISE, DIVERTED. MAINTENANCE INSPECTED AND REPLACED AIR CYCLE MACHINE, OPS CHECKED GOOD.SDR RAIA201406040002Cable · out of adjustMAIN CABIN DOOR DIFFICULT TO OPEN DURING POST FLIGHT. MAINTENANCE ADJUSTED CABLES, OPS CHECK GOOD.SDR RAIA201406030001Door · lack of lubeMAIN CABIN DOOR DIFFICULT TO OPEN DURING POST FLIGHT. MAINTENANCE INSPECTED AND LUBED THE DOOR SEAL, OPS CHECKED GOOD.SDR RAIA201406020002Door · lack of lubeTHE MAIN CABIN DOOR WAS HARD TO OPEN DURING POST FLIGHT. MAINTENANCE INSPECTED AND LUBED DOOR AND FRAME SEALS, OPS CHECK GOOD.SDR RAIA201404220001Door Sill · corrodedPASSENGER DOOR SILL CORRODED. MAINTENANCE REPLACED DOOR SILL.SDR RAIA201404170006Floor Support · corrodedLEFT OMEGA BEAM GUSSET AT FRAME 59-FRAME 61 HAS LEVEL 2 CORROSION. MAINTENANCE REPLACED LT OMEGA BEAM GUSSET.SDR RAIA201404170005Structure · corrodedLEFT SILL FROM FRAMES 61-65 CORRODED. REPLACED LT SILL.SDR RAIA201404170004Structure · corrodedRIGHT SILL FRAME 59-61 HAS LEVEL 2 CORROSION. REPLACED RT SILL.SDR RAIA201404170003Floor Support · corrodedRIGHT OMEGA BEAM GUSSET AT FRAMES 59-61 CORRODED. MAINTENANCE REPLACED RT GUSSET.SDR RAIA201404170002Floor Support · corrodedCENTER OMEGA BEAM GUSSET AT FRAMES 59-61 CORRODED. MAINTENANCE REPLACED CENTER OMEGA BEAM GUSSET.SDR RAIA201404170001Structure · corrodedLEFT SILL AT FRAMES 59-61 CORRODED. MAINTENANCE REPLACED LT SILL.SDR RAIA201311300001Bulb · inoperativeLEFT OVERWING EMERGENCY EXIT LIGHT IS INOPERATIVE. MAINTENANCE REPLACED BULB, OPS CHECKED GOOD.SDR RAIA201310220001Door · unknownPASSENGER DOOR WILL NOT OPEN FROM INSIDE. MAINTENANCE INSPECTED DOOR AND VERIFIED THAT IT CLOSES AND LOCKS FROM OUTSIDE. ACFT SAFE FOR FERRY FLIGHT.SDR RAIA201307080001Step · inoperativePASSENGER DOOR NR 2 STAIR NOT DEPLOYING. FERRIED ACFT AND MX REPLACED STEP ASSY, OPS CHECKED GOOD.SDR RAIA201305100006Support · corrodedDURING SCHEDULED MAINTENANCE, FOUND CORROSION AROUND TRANSPONDER. MX R & R THE SUPPORT ASSY AROUND THE TRANSPONDER ANTENNA.SDR RAIA201305100005Floor Support · corrodedDURING SCHEDULED MX, THE CARGO BAY FLOORBOARD SUPPORT PLATE ON BEAM Y-479 AT FRAME 65 TO FRAME 68 WAS FOUND CORRODED. MX R & R THE CARGO BAY FLOORBOARD SUPPORT PLATE ON BEAM Y-479 AT FRAME 65 TO FRAME 68.SDR RAIA201305100004Support Angle · corrodedDURING SCHEDULED MX, CARGO BAY RAMP SUPPORT ANGLE WAS FOUND CORRODED AT FRAME 65. MX R & R THE CARGO BAY RAMP SUPPORT ANGLE.
Back to N855HK, cancelled Feb 10, 2024