SDR WX0A201704050001Generator · failedLEAVING CRUISE ALTITUDE, ELECTRICAL INTERRUPTION RESULTED IN AUTOPILOT & AT DISCONNECT, FOLLOWED BY DFGC FAILURES, LOSS OF ALL FO FLIGHT INSTRUMENTATION AND FLAGGING OF FO PRIMARY FLIGHT INSTRUMENTS. AOP SCREEN WAS DIFFICULT TO READ AS FAULT MESSAGES WERE LAYEApr 3, 2017 · N862GA · Doug DC983 · AC Generator-AlternatorSDR WX0A2017032773233Duct · not reportedEMERGENCY DECLARED, RT ENGINE FIRE DETECTOR LOOP ANNUNCIATOR ILLUMINATED, IMMEDIATELY FOLLOWED BY RT ENGINE FIRE. R&R RT ENG AFT IGV DUCT, FUEL/AIR HEATER AIR SHUTOFF VALVE, AND MAIN OIL FILTER.Mar 25, 2017 · N862GA · Doug DC983 · Turbine Engine Reduction GearSDR JR2R20170209116Stiffener · crackedBOTTOM OF STIFFINER INSIDE OF NR 2 ENG NOSE COWL CRACKED AT 7:30 POSISTION. REMOVED AND REPLACED THE STIFFNER IAW EA40-2017-015.Feb 9, 2017 · N862GA · Doug MD83 · Nacelle/Pylon Miscellaneous StructureSDR WX0A2015113000016Battery Pack · inoperativeEMERGENCY LIGHTING IN TAILCONE INOPERATIVE. R & R EMERGENCY BATTERYS IAW AMM 33-53-00, OP CHECK GOOD.Nov 26, 2015 · N862GA · Doug DC983 · Emergency LightingSDR WX0A2015102072958Wire · chafedWHEN LG RETRACTED, CB 26P, LG WARNING POPS. AFTER TAKEOFF, WHEN LG RETRACTED, ALL 4 ANTI-SKID ANNUNCIATORS ILLUMINATED. RAN QRH 32.2 & CONTINUED FLIGHT. FOUND LG ANTI-RETRACTION CABLE TENSION SPRING CHAFING WIRE G200C22. CONNECTED CABLE TENSION SPRING TO BOct 18, 2015 · N862GA · Doug DC983 · Landing Gear System WiringSDR WX0A2015100172909Slat · damagedRIGHT NR 5 SLAT DAMAGED. R & R NR 5 RT SLAT IAW AMM 27-80=-01-4-0.Sep 28, 2015 · N862GA · Doug DC983 · Leading Edge DevicesSDR WX0A2015080372767Battery · dischargedCOCKPIT & GALLEY AREA EMERGENCY LIGHTS INOPERATIVE. REPLACED BATTERIES. OPERATIONS CHECKED GOOD IAW MM 33-53-00.Jul 27, 2015 · N862GA · Doug DC983 · Emergency LightingSDR WX0A2015070972724Charger · inoperativeCOCKPIT OVERHEAD EMER LIGHT DOES NOT WORK WITH EMER LIGHT SWITCH. REPLACED BATTERY CHARGER & BATTERY PACK IAW MM 33-53-00.Jul 3, 2015 · N862GA · Doug DC983 · Emergency LightingSDR WX0A072713Battery Pack · dischargedEMERGENCY LIGHT NOT TURNING ON AT FLIGHT ATTENDANT OVERHEAD PANEL, FWD FLIGHT ATTENDANT CEILING PANEL & FWD GALLEY CELLING. R & R BATTERY PACK AT FWD FLIGHT ATTENDANT STATION IAW AMM 33-50-00. OPERATIONS CHECKED GOOD.Jun 30, 2015 · N862GA · Doug DC983 · Emergency LightingSDR WX0A2015062472686Terminal · unsecureDURING COCKPIT PREFLIGHT, EMER LIGHTS INSIDE COCKPIT WILL NOT TURN ON WITH EMER LIGHT SWITCH IN ON POSITION. SECURED TERMINAL ON COCKPIT EMER LIGHT BATTERY SUPPLY & OPERATIONS CHECKED OK IAW MM 33-53-00.Jun 23, 2015 · N862GA · Doug DC983 · Emergency LightingSDR WX0A2015060572641Battery · dischargedCOCKPIT EMER LIGHT NOT WORKING. R & R BATTERIES TO EMER LIGHT PACK FOR COCKPIT IAW AMM 33-53-00. OPERATIONS CHECKED GOOD.Jun 4, 2015 · N862GA · Doug DC983 · Emergency LightingSDR WX0A2015060372639Battery · dischargedEMERGENCY LIGHTS ON OVERHEAD PANEL NOT WORKING. CHARGED BATTERIES IN ARMED POSITION OPERATIONS CHECKED GOOD AT THIS TIME IAW AMM 33-53-01.Jun 1, 2015 · N862GA · Doug DC983 · Emergency LightingSDR WX0A2015052772608Power Supply · inoperativeFOUND ON WAKE UP, FWD CABIN & FLIGHT DECK EMER LIGHTS INOPERATIVE. REPLACED POWER SUPPLY. OPERATIONS CHECKED GOOD IAW AMM 33-53-01.May 22, 2015 · N862GA · Doug DC983 · Emergency LightingSDR WX0A2015052072604Battery · dischargedCOCKPIT & FWD GALLEY EMER LIGHTS OUT. R & R POWER PACK BATTERIES IAW MM 33-53-00. OPERATIONS CHECKED GOOD.May 19, 2015 · N862GA · Doug DC983 · Emergency LightingSDR WX0A2015033072491Battery · dischargedAT ROW 26, ONE EMER LIGHT INOPERATIVE & ROW 27, ONE EMER LIGHT INOPERATIVE. REPLACED BATTERIES TO POWER SUPPLY AT ROW 27. LIGHTS FOR BOTH LAMPS VERY DIM. REPLACED POWER SUPPLY. EMER LIGHTS CHECKED NORMAL IAW AMM 33-53-01.Mar 27, 2015 · N862GA · Doug DC983 · Emergency LightingSDR WX0A2015081172791Tire · damagedEMERGENCY DECLARED FOR SEVERE NOSE WHEEL VIBRATION DURING & AFTER TAKEOFF FROM RNWY 1R. THE CREW HELD TO BURN OFF FUEL TO BE BELOW MAXIMUM LANDING WEIGHT FOR THE LANDING. IN HOLDING, HEARD A LOUD SINGLE POP & IN THE DESCENT HEARD A LOUD SINGLE POP. THIS POPFeb 23, 2015 · N862GA · Doug DC983 · TireSDR WX0A2015022372435Battery · dischargedFLIGHT DECK EMER LIGHTS WILL NOT ILLUMINATE WHEN SELECTED ON. R & R EMER LIGHT BATTERIES IAW AMM 33-53-00. OPERATIONS CHECKED GOOD.Feb 22, 2015 · N862GA · Doug DC983 · Emergency LightingSDR WX0A2015010772338Battery · dischargedFWD AISLE EMER LIGHT & COCKPIT EMER LIGHT INOPERATIVE. REPLACED EMER LIGHT POWER SUPPLY BATTERIES IAW AMM 33-53-00-4. OPERATIONS CHECKED OK.Jan 3, 2015 · N862GA · Doug DC983 · Emergency LightingSDR WX0A2014122272314Battery Pack · dischargedFORWARD EMER LAMPS INOPERATIVE, DIM. REPLACED BATTERY PACK IAW AMM 33-53-00. OPERATIONS CHECKED GOOD.Dec 19, 2014 · N862GA · Doug DC983 · Emergency LightingSDR WX0A2014110772259Light · inoperativeAFT CABIN DOOR EMER EXIT LIGHT INOPERATIVE. R & R AFT CABIN DOOR EMER EXIT LAMP. OPERATIONS CHECKED GOOD IAW AMM 33-53-00.Nov 4, 2014 · N862GA · Doug DC983 · Emergency LightingSDR WX0A072244Battery · dischargedEMERGENCY LIGHT INSIDE COCKPIT DOES NOT LIGHT UP WHEN TESTED. REPLACED BATTERIES AT FWD GALLEY BATTERY PACK IAW MM 33-53-00. OPERATIONS CHECKED NORMAL.Oct 30, 2014 · N862GA · Doug DC983 · Emergency LightingSDR WX0A072189Battery · dischargedFLIGHT DECK EMER LIGHTS NOT WORKING. RELAMPED & REPLACED BATTERIES IAW MM 33-50-00. OPERATIONS CHECKED GOOD.Oct 5, 2014 · N862GA · Doug DC983 · Emergency LightingSDR WX0A2014090972143Battery · dischargedFORWARD EMER BATTERY NEEDS TO BE CHANGED, LIGHTS OUT. R & R EMER BATTERY IAW AMM 33-53-00. OPERATIONS CHECKED GOOD.Sep 2, 2014 · N862GA · Doug MD83 · Emergency LightingSDR WX0A2014090472135Seat Track · corrodedPASSENGER CABIN LT SEAT TRACK IS CORRODED AT STATION 200 LBL 44. REMOVED DAMAGE SECTION OF SEAT TRACK, FABRICATED REPAIRS SLICE & INSTALLED SLICE & NEW SEAT TRACK IAW SRM 53-05 FIG 4F WORK ORDER 228223 M301 284 WORK ORDER 1011150 2400 - 0105.Aug 30, 2014 · N862GA · Doug DC983 · Fuselage, Seat/Cargo Attach FittingsSDR WX0A2014090372130Battery · dischargedFORWARD EMER LIGHTS OUT STATION 300. R & R FWD EMER BATTERIES IAW AMM 33-53-01. OPERATIONS CHECKED GOOD.Aug 30, 2014 · N862GA · Doug DC983 · Emergency LightingSDR WX0A2014090372129Battery · dischargedEMERGENCY LIGHT BULB IN COCKPIT INOPERATIVE. REPLACED EMER LIGHT BATTERIES. OPERATIONS CHECKED GOOD IAW AMM 33-53-00.Aug 28, 2014 · N862GA · Doug DC983 · Emergency LightingSDR WX0A2014080572078Unknown · malfunctionedWEATHER RADAR FAILED INFLIGHT. PERFORMED OPERATIONS TEST OF WEATHER RADAR SYS IAW AMM 34-41-00. SYSTEM TESTED GOOD. SUSPECT WEATHER RADAR FAILED DUE TO ATTITUDE LOSS FROM DFGC 1 & DFGC 2. SEE LOG PAGE 539257, NO HISTORY PAST 30 DAYS. 8/5/14 NO HISTORY BAAug 3, 2014 · N862GA · Doug MD83 · Weather Radar SystemSDR WX0A2014080572077Selector · faultyON CLIMB OUT PRESSURIZATION TRANSFER LOCKOUT & STANDBY ON LIGHTS ILLUMINATED. QRH PROCEDURES ACCOMPLISHED, LIGHTS RE-ILLUMINATED, PRESSURIZATION NORMAL. PLACED ON MEL 21-24 SIT 1 CAT C DMI 10590, PLACARD INSTALLED. PERFORMED BITE CHECK ON BOTH PRIMARY & STBAug 1, 2014 · N862GA · Doug MD83 · Cabin Pressure Control SystemSDR WX0A2014071872033Light · inoperativeROW 15 EMER BULB OUT. R & R ROW 15 EMER LIGHT BULB IAW AMM 33-53-00. OPERATIONS CHECKED GOOD.Jul 16, 2014 · N862GA · Doug MD83 · Emergency LightingSDR WX0A071992Light · inoperativeCOCKPIT EMER LIGHTS INOPERATIVE. RELAMPED FLIGHT DECK EMER LAMPS. OPERATIONS CHECKED GOOD IAW AMM 33-51-00.Jun 15, 2014 · N862GA · Doug MD83 · Emergency LightingSDR WX0A071961Battery · dischargedFLIGHT DECK EMER LIGHTS INOPERATIVE. REPLACED FWD EMER BATTERIES, OPERATIONS CHECKED GOOD IAW MM 33-53-00.May 26, 2014 · N862GA · Doug MD83 · Emergency LightingSDR WX0A071962Battery · dischargedFLIGHT DECK EMER LIGHTS INOPERATIVE. R & R EMER BATTERIES IAW MM 33-53-01, OPERATIONS CHECKED GOOD.May 23, 2014 · N862GA · Doug MD83 · Emergency LightingSDR WX0A071808Beam · corrodedAFT CARGO DOOR CUTOUT LOWER JAMB BEAM CORRODED. REMOVED CORROSION & CUTOUT SMALL SECTION AT AFT DOOR STOP ON BEAM. FABRICATED REPAIR DOUBLER & REPAIR PARTS, LOCATED, DRILLED & INSTALLED PERMANENT REPAIR IAW MD80 SRM 53-05 FIGURE 123A OPTION 2Jan 2, 2014 · N862GA · Doug MD83 · Fuselage Main, StructureSDR WX0A071767Seat Track · corrodedSEAT TRACK AT LBL 44 FS 200 TO FS 218 CORRODED. R & R SEAT TRACK AT LBL 44 FS 200 TO FS 218 IAW MD-80 SRM 53-05 FIG 4H.Dec 5, 2013 · N862GA · Doug MD83 · Fuselage, Seat/Cargo Attach FittingsSDR WX0A2013030471526Doubler · corrodedFWD LAV SERVICE PANEL AREA DOUBLER IS CORRODED AT THE BOTTOM OF THE FWD DOOR HINGE. CUT OUT DAMAGED AREA AT INTERNAL DOUBLER, FABRICATED REPAIR FILLER, DOUBLER AND TRIPLER AND INSTALLED REPAIR PARTS.Mar 4, 2013 · N862GA · Doug DC983 · Fuselage Main, Plate/SkinSDR WX0A071525Skin · corrodedAFT LAV SERVICE PAN EXTERIOR SKIN, DOUBLER AND CENTER OF LAV SERVICE PAN IS CORRODED. CUT OUT DAMAGED AREA AT INTERNAL DOUBLER, FABRICATED REPAIR FILLER DOUBLER AND TRIPLER AND INSTALLED REPAIR PARTS.Mar 4, 2013 · N862GA · Doug DC983 · Fuselage Main, Plate/SkinSDR WX0A071207Engine · malfunctionedFLIGHT CREW PERSONNEL REPORTED THAT DURING CLIMBOUT AT APPROX FL270, LEFT ENGINE COMPRESSOR STALL/ ENGINE PARAMETERS ROLLED BACK ENGINE SHUTDOWN PER CHECKLIST. MAINTENANCE PERSONNEL REPLACED THE LEFT ENGINE IAW TASK CARD R0807101, OPS AND LEAK GOOD. AIRCRAFTMay 18, 2012 · N862GA · Doug MD83 · Engine (Turbine/Turboprop)SDR WX0A070998Battery · dischargedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE BATTERIES IN THE POWER SUPPLY BATTERNov 3, 2011 · N862GA · Doug MD83 · Emergency LightingSDR WX0A070976Battery · dischargedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE BATTERIES IN THE POWER SUPPLY BATTEROct 1, 2011 · N862GA · Doug MD83 · Emergency LightingSDR WX0A070870Battery · dischargedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE BATTERIES IN THE POWER SUPPLY BATTERMay 30, 2011 · N862GA · Doug MD83 · Emergency LightingSDR WX0A070543Light · inoperativeDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REPLACED EMERGENCY LIGHT ASSEMBLY AS REQUIRED. A SATISFACTORY OPERATIONAMar 25, 2010 · N862GA · Doug MD83 · Emergency LightingSDR WX0A070438Sensor · malfunctionedLEFT ENGINE OIL TEMP HIGH (AMBER) LIGHT ILLUMINATED. REDUCED POWER, NORMAL FUEL TEMP, OIL TEMP AND OIL QUANTITY INDICATIONS. ADDED POWER TO APPROX 80 PERCENT N1, OIL TEMP REDUCED FROM A HIGH OF 149 DEGREES TO A STABLE 124 DEGREES. ENGINE NOT SHUTDOWN. MAINOct 31, 2009 · N862GA · Doug MD83 · Engine Oil Indicating SystemSDR WX0A070412Battery Pack · inoperativeDURING A ROUTINE OVERNIGHT SERVICE CHECK, INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE BATTERIES IN THE POWER SUPPLY BATTESep 10, 2009 · N862GA · Doug DC983 · Emergency LightingSDR WX0A070362Power Supply · dischargedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE BATTERIES IN THE POWER SUPPLY BATTERJul 31, 2009 · N862GA · Doug MD83 · Emergency LightingSDR WX0A070315Battery Pack · inoperativeDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE POWER SUPPLY BATTERY PACK. A SATISFMay 29, 2009 · N862GA · Doug MD83 · Emergency LightingSDR WX0A070285Power Supply · no testDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE POWER SUPPLY BATTERY PACK. A SATISFApr 7, 2009 · N862GA · Doug DC983 · Emergency LightingSDR WX0A070257Battery Pack · inoperativeDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE BATTERIES IN THE POWER SUPPLY BATTERDec 31, 2008 · N862GA · Doug DC983 · Emergency LightingSDR WXO2008F00000Battery Pack · failedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION, MAINT REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINT REMOVED AND REPLACED THE APPROPRIATE BATTERIES IN THE POWER SUPPLY BATTERY PACK. A SATISFACTORY OPERATIONAL CHECK WAAug 9, 2008 · N862GA · Doug DC983 · Emergency LightingSDR 070177Battery Pack · dischargedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE POWER SUPPLY BATTERY PACK. A SATISFNov 11, 2007 · N862GA · Doug DC983 · Emergency LightingSDR 070133Battery Pack · dischargedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE POWER SUPPLY BATTERY PACK. A SATISFJun 20, 2007 · N862GA · Doug DC983 · Emergency Lighting
Back to N862GA, cancelled Oct 1, 2022