N864GA, cancelled May 27, 2025

Service difficulty reports · 78

Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.

Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy
  FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet'
  WHERE n_number = 'N864GA' AND deregistration_id = 'N864GA-2025-05-27'
  ORDER BY difficulty_date DESC"

Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.

SDR WX0A2018071073352Megaphone · inoperativeFOUND AFT MEGAPHONE INOP. R&R AFT MEGAPHONE.Jul 9, 2018 · N864GA · Doug DC983 · Emergency EquipmentSDR WX0A2018071073349Acm · odorSTRONG EXHAUST SMELL COMING FROM PACKS WHILE USING APU AIR. R&R LT ACM, BOTH COALESCER BAGS AND PERFORMED CLEANING OF DUCTS.Jul 5, 2018 · N864GA · Doug DC983 · Cabin Cooling SystemSDR JR2R201802010001Fitting · crackedRT LOUVER CLIP AT CANTED FRAME 1463 CRACKED AT LONG 7R. REPLACED RT LOUVER CLIP AT LONG 7R STA 1463.Jan 31, 2018 · N864GA · Doug DC983 · Fuselage Miscellaneous StructureSDR JR2R201802010002Fitting · crackedRT LOUVER CLIP CRACKED AT CANTED FRAME LONG 8R. REPLACED CLIP AT CANTED FRAME STA 1463 LONG 8R.Jan 31, 2018 · N864GA · Doug DC983 · Fuselage Miscellaneous StructureSDR JR2R201801309Fitting · crackedLT LOUVER CLIP CRACKED AT CANTED FRAME STA 1463 LONG 8L. REPLACED LT LOUVER CLIP IAW SRM 51-30-5.Jan 31, 2018 · N864GA · Doug DC983 · Fuselage Miscellaneous StructureSDR JR2R2018013110Fitting · crackedLT LOUVER CLIP CRACKED AT CANTED FRAME 1643 LONG 7L. REPLACED LT LOUVER CLIP IAW SRM 51-30-5.Jan 31, 2018 · N864GA · Doug DC983 · Fuselage Miscellaneous StructureSDR JR2R201708193632Former · crackedINTERNAL VENTRAL FORMER CRACKED. REMOVED AND REPLACED FORMER IAW SRM 51-30-1 FIG 1, 51-30-5 PARA 7.Aug 19, 2017 · N864GA · Doug MD83 · Vertical Stabilizer, Spar/RibSDR JR2R201708193631Fitting · crackedINTERNAL VENTRAL CLIP CRACKED. REMOVED AND REPLACED CLIP IAW MD80 SRM 51-30-2 FIG 1, 51-30-5 PARA 7.Aug 19, 2017 · N864GA · Doug MD83 · Vertical Stabilizer Miscellaneous StructureSDR JR2R20170816050Skin · corrodedFUSELAGE SKIN IS CORRODED AT THE AFT LAVATORY SERVICE PANEL DOOR FWD LOWER CORNER. REPAIRED THE SKIN IAW EA 25-2017-085.Aug 16, 2017 · N864GA · Doug MD83 · Fuselage Main, Plate/SkinSDR JR2R20170815291Longeron · damagedLONGERON IN AFT CARGO BAY DAMAGED. REPAIRED THE LONGERON IAW SRM 53-05, FIG 18.Aug 15, 2017 · N864GA · Doug MD83 · Fuselage Main, Longeron/StringerSDR JR2R10170815036Beam · corrodedAFT CARGO DOOR FRAME BEAM CORRODED. REMOVED AND REPLACED AFT CARGO DOOR BEAM IAW SRM 51-10-4, 51-30-2, AND 51-30-5.Aug 15, 2017 · N864GA · Doug MD83 · Fuselage Main, StructureSDR JR2R20170814343Panel · crackedPANEL 3804A HAS CRACK IN MIDDLE OF PANELAug 14, 2017 · N864GA · Doug MD83 · Horizontal Stabilizer StructureSDR JR2R20170811290Doubler · corrodedAFT CARGO BAY, FOUND CORROSION ON THE INTERNAL DOUBLER BS 1174 - 1194.Aug 12, 2017 · N864GA · Doug MD83 · Fuselage Main, Plate/SkinSDR JR2R20170809330Intercostal · corrodedAFT CARGO BAY HAS A CORRODED INTERCOSTAL. REMOVED AND REPLACED INTERCOSTAL IAW SRM 51-104, AND 51-30-2,31-30-5.Aug 9, 2017 · N864GA · Doug MD83 · Fuselage Miscellaneous StructureSDR WX0A2017070873271Engine · failed(EMERGENCY DECLARED) LT ENGINE FAILED AFTER LOUD BANG. R&R LT ENGINE.Jul 3, 2017 · N864GA · Doug DC983 · Engine (Turbine/Turboprop)SDR WX0A2017070373271Engine · failedEMERGENCY DECLARED, LT ENGINE FAILED AFTER LOUD BANG. AC AOG.Jul 3, 2017 · N864GA · Doug DC983 · Engine (Turbine/Turboprop)SDR WX0A073247Bulb · failedBURNED RUBBER ODOR ON TAKE OFF FROM BOTH FORWARD & AFT FA STATIONS. R & R THE BULB.May 1, 2017 · N864GA · Doug DC983 · Passenger Compartment LightingSDR WX0A2016012973080Frame · crackedFRAME CRACKED AT FS 937, RBL 4, AT ANTI-ICE DUCT. REPAIRED FRAME IAW SRM 53-05 FIG 81. M301 ITEM 150 WO 1012435 1000 0035.Jan 22, 2016 · N864GA · Doug DC983 · Fuselage Main, FrameSDR WX0A2016012673076Frame · crackedFRAME CRACKED AT FS 937, RBL 4, AT ANTI-ICE DUCT. REPAIRED FRAME IAW SRM 53-05 FIG 81.Jan 22, 2016 · N864GA · Doug DC983 · Fuselage Main, FrameSDR WX0A2015101972955Battery · dischargedEMERGENCY LIGHTS OUT, ROW 15, 17 & 19, UPPER CABIN. R & R EMER LIGHT BATTERY ON ROW 17 DEF IAW AMM 33-53-01. OPERATIONS CHECKED GOOD.Oct 18, 2015 · N864GA · Doug DC983 · Emergency LightingSDR WX0A2015100572917Warning System · false activationAFTER SLAT RETRACTION, SLAT DISAGREE ILLUMINATED & LIGHT REMAINED ILLUMINATED. COMPLETED QRH 27.8, LIGHT EXTINGUISHED CLIMBING THROUGH FLIGHT LEVEL 200. FLIGHT CONTINUED, NO ROLLING TENDENCY NOTICED. SLAT FLAP EXTENSION DURING APPROACH & LANDING NORMAL. ROct 1, 2015 · N864GA · Doug DC983 · Leading Edge Slat Position Indicating SystemSDR WX0A2015072072735Battery · dischargedPORTABLE CABIN EMER LIGHT INOPERATIVE. REPLACED BATTERIES IN PORTABLE CABIN EMER LIGHT IAW AMM 33-53-00. OPERATIONS CHECKED GOOD.Jul 13, 2015 · N864GA · Doug DC983 · Emergency LightingSDR WX0A072733Battery · dischargedPORTABLE CABIN EMER LIGHT INOPERATIVE. REPLACED BATTERIES IN PORTABLE CABIN EMER LIGHT IAW AMM 33-53-00. OPERATIONS CHECKED GOOD.Jul 13, 2015 · N864GA · Doug DC983 · Emergency LightingSDR WX0A2015062272680Control Valve · out of adjustDURING CRUISE, PNEU PRESS READ 30 PSI WITH BOTH XFEED LEVERS CLOSED. WHEN EITHER LT OR RT AIRFOIL SWITCH TURNED ON PSI DROPPED TO ZERO. WHEN EITHER LT OR RT AIRFOIL SWITCH TURNED OFF, PNEU PSI WOULD SLOWLY BUILD BACK UP TO 30 PSI WITH BOTH XFEED LEVERS CLOSEJun 20, 2015 · N864GA · Doug DC983 · Pneumatic Distribution SystemSDR WX0A2015062272679Target · out of adjustAFTER FLAP & SLAT RETRACTION DISAGREE LIGHT REMAINED ILLUMINATED, FOUND LEFT SLAT D PROX SENSOR TARGET HANGING UP. ADJUSTED SAME & OPERATIONS CHECKED IAW MM 27-80-06. OK FOR SERVICE.Jun 20, 2015 · N864GA · Doug DC983 · Leading Edge Slat Position Indicating SystemSDR WX0A2015030472443Flap · crackedLEFT OTBD TE OF FLAP IS CRACKED. REPAIRED LT OTBD TE FLAP IAW SRM 57-03.Feb 25, 2015 · N864GA · Doug DC983 · Trailing Edge FlapsSDR WX0A2014090472136Longeron · crackedLONGERON 30 CRACKED AT APPROX FS 244 & 250. REPAIRED LONGERON 30 IAW SRM 53-02 FIG 18.Aug 26, 2014 · N864GA · Doug DC983 · Fuselage Main, Longeron/StringerSDR WX0A2014082772118Longeron · crackedLONGERON 29L CRACKED AT APPROX FS 244 & 250. REPAIRED LONGERON 29L IAW SRM 53-02 FIG 8.Aug 26, 2014 · N864GA · Doug DC983 · Fuselage Main, Longeron/StringerSDR WX0A2014082672115Frame · corrodedFRAME AT FS 1250 LONGERON 30 CORRODED. REMOVED PREVIOUS REPAIR, FABRICATED & INSTALLED FRAME & REPAIR PARTS IAW SRM 53-03 FIG 2 A. WORK ACCOMPLISHED ON WORK ORDER 1011099-1000-0087 M301 ITEM 400.Aug 23, 2014 · N864GA · Doug MD83 · Fuselage Main, FrameSDR WX0A2014082172102Seat Track · mechanic errorCABIN SEAT TRACK DOUBLE DRILLED STATION 1307 AT LBL 22. CUT OUT DAMAGED SEAT TRACK FROM STATION 1260 TO 1309. FABRICATED REPLACEMENT SEAT TRACK, LOCATED, DRILLED & INSTALLED A SPLICE REPAIR AT STATION 1260 IAW SRM 53-05 FIGURE 4F. WORK ACCOMPLISHED ON WORK Aug 21, 2014 · N864GA · Doug DC983 · Fuselage, Seat/Cargo Attach FittingsSDR WX0A071971Portable Light · inoperativeFORWARD FLIGHT ATTENDANT FLASHLIGHT INOPERATIVE. R & R PORTABLE FLASHLIGHT IAW MM33-53-00. OPERATIONS CHECKED GOOD.May 30, 2014 · N864GA · Doug MD83 · Emergency LightingSDR WX0A071925Battery Pack · dischargedLEFT & RIGHT FWD EXIT IDENTIFIERS WILL NOT LIGHT UP WHEN TESTING EMERGENCY LIGHTS. R & R BATTERY PACK FOR LT & RT FWD EXIT IDENTIFIERS IAW AMM 33-53-00 & 33-53-01, OPERATIONS CHECKED GOOD.Apr 21, 2014 · N864GA · Doug MD83 · Emergency LightingSDR WX0A071891Acm · overservicedDURING CLIMB OUT MULTIPLE PRESS BUMPS WERE FELT, SMOKE WAS VISIBLE IN COCKPIT. FOLLOWED QRH PROCEDURE & TURNED LEFT PACK OFF. SMOKE DISSIPATED & PRESSURIZATION BEGAN WORKING NORMALLY. PERFORMED WORK ORDER 22195, NO FURTHER DEFECTS NOTED. TROUBLE SHOT LT PAMar 22, 2014 · N864GA · Doug MD83 · Cabin Cooling SystemSDR WX0A071823Battery · dischargedAFT FLIGHT ATTENDANT`S POSITION, ONE EMERGENCY FLASHLIGHT NOT FLASHING. REPLACED BATTERY IN FLASHLIGHT IAW AMM 25-60-00.Jan 20, 2014 · N864GA · Doug MD83 · Emergency EquipmentSDR WX0A201308210072Battery Pack · inoperativeFWD FA STATION UPPER EMERGENCY FLASHLIGHT INDICATOR DOES NOT BLINK. REF AMM 25-60-00; R & R BATTERY PACK ASSY. OPS CHECKED NORMAL. SECURED FLASHLIGHT IN HOLDER.Aug 15, 2013 · N864GA · Doug DC983 · Emergency EquipmentSDR WX0A2013070800026Battery Pack · inoperativeDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION, MX REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYS WOULD NOT TEST. MX R & R BATTERY PACK IN THE POWER SUPPLY AND LIGHT RELAY, MADE ALL REQUIRED CORRECTIONS AND OPS CHECK WAS ACCOMPLISHED IAW AMMJun 28, 2013 · N864GA · Doug DC983 · Emergency LightingSDR WX0A071477Battery · dischargedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE BATTERIES IN THE POWER SUPPLY BATTERJan 7, 2013 · N864GA · Doug DC983 · Emergency LightingSDR WX0A071463Battery · dischargedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE BATTERIES IN THE POWER SUPPLY BATTERDec 31, 2012 · N864GA · Doug DC983 · Emergency LightingSDR WX0A071408Battery · dischargedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE BATTERIES IN THE POWER SUPPLY BATTERNov 8, 2012 · N864GA · Doug DC983 · Emergency LightingSDR WX0A071406Battery · dischargedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE BATTERIES IN THE POWER SUPPLY BATTERNov 8, 2012 · N864GA · Doug DC983 · Emergency LightingSDR WX0A071374Battery Pack · dischargedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE POWER SUPPLY BATTERY PACK AND MADE AOct 24, 2012 · N864GA · Doug DC983 · Emergency LightingSDR WX0A071287Battery · dischargedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE BATTERIES IN THE POWER SUPPLY BATTERAug 25, 2012 · N864GA · Doug MD83 · Emergency LightingSDR WX0A071158Battery · dischargedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE BATTERIES IN THE POWER SUPPLY BATTERApr 6, 2012 · N864GA · Doug MD83 · Emergency LightingSDR WX0A071066Battery · dischargedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE BATTERIES IN THE POWER SUPPLY BATTERJan 2, 2012 · N864GA · Doug MD83 · Emergency LightingSDR WX0A071065Battery · dischargedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE BATTERIES IN THE POWER SUPPLY BATTERYJan 2, 2012 · N864GA · Doug MD83 · Emergency LightingSDR WX0A071015Battery Pack · dischargedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE POWER SUPPLY BATTERY PACK AND MADE ANov 20, 2011 · N864GA · Doug MD83 · Emergency LightingSDR WX0A070920Skin Panel · gougedVERTICAL STAB UPPER AFT FAIRING CHAFED AND GOUGED ON LEFT SIDE. REMOVED, FABRICATED AND INSTALLED NEW SKIN PANEL IAW EA 14482 REV 1R DATED 3 AUG 2011 AND MD80 SRM 51-10-4, 51-30-2.Aug 8, 2011 · N864GA · Doug MD83 · Vertical Stabilizer, Plate/SkinSDR WX0A070919Skin Panel · gougedVERTICAL STAB UPPER AFT FAIRING CHAFED AND GOUGED ON RIGHT AFT SIDE. REMOVED, FABRICATED AND INSTALLED SKIN PANEL IAW EA 14483 REV 1R DATED 3 AUG 2011, MD80 SRM 51-30-2, 51-10-4.Aug 8, 2011 · N864GA · Doug MD83 · Vertical Stabilizer, Plate/SkinSDR WX0A070823Battery Pack · dischargedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE POWER SUPPLY BATTERY PACK AND MADE AApr 1, 2011 · N864GA · Doug MD83 · Emergency LightingSDR WX0A070822Battery Pack · dischargedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE POWER SUPPLY BATTERY PACK AND MADE AApr 1, 2011 · N864GA · Doug MD83 · Emergency Lighting
Back to N864GA, cancelled May 27, 2025