N868CA, cancelled Mar 8, 2023
Service difficulty reports · 105
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N868CA' AND deregistration_id = 'N868CA-2023-03-08' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N868CA' AND deregistration_id = 'N868CA-2023-03-08' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR SWIA2019071946078Engine · failedLEFT ENGINE FAILURE DURING CLIMB OUT. DECLARED EMERGENCY, COMPLETED QRH, SHUTDOWN LEFT ENGINE IN FLIGHT. (FLT#3780) FO: 07/19/2019 CLOSED REMOVED AND REPLACED LT ENGINE IAW AMM. OPS AND LEAK CHECKS GOOD.SDR SWIA2018061544779Nut · unsecureMLG BAY OVHT WARNING AFTER TAKEOFF AND INITIATING GEAR RETRACTION. MESSAGE WENT AWAY ABOUT 2 MINS LATER. DECLARED EMERGENCY AS A PRECAUTION AND LANDED NORMALLY. NO FURTHER WARNINGS. (FLT 4452) 06/14/2018 CLOSED RESECURED RT MLG BAY OVERHEAT LOOP MOUNTING NUSDR SWIA2018052244712Floorbeam · corrodedCORROSION ON FLOORBEAM AT RBL 27 APPROX FS559+85. (C-CHECK) 05/20/2018 REPAIRED FLOORBEAM AT RBL.27 APPROX FS 559.85 IAW SRM.SDR SWIA2018052244711Floorbeam · corrodedCORROSION ON FLOORBEAM AT RBL 27 FROM FS605 TO FS589. (C-CHECK) 05/20/2018 REMOVED CORROSION FROM FLOORBEAM AT RBL 27 FROM FS589 TO FS605 COMPLIED WITH ALL STEPS OF REPAIR IAW REO.SDR SWIA2018052244710Floorbeam · corrodedCORROSION ON FLOORBEAM AT LBL 9 FS 559+96. (C-CHECK) 05/20/2018 COMPLIED WITH REPAIR IAW SRM.SDR SWIA2018052244709Floorbeam · corrodedCORROSION ON FLOORBEAM AT RBL 9 FS574. (C-CHECK) 05/20/2018 INSTALLED NEW FLOORBEAM AT RBL FROM FS569-FS621 IAW REO AND SRM.SDR SWIA2018052244708Support Plate · corrodedCORROSION ON GALLEY MOUNT SUPPORT PLATE AT APPROX FS 355 RBL9. (C-CHECK) 05/20/2018 REMOVED AND REPLACED GALLEY FLOOR MOUNT PLATE AT FS 355 RBL 9.0 IAW SRM.SDR SWIA2018052244707Support Plate · corrodedCORROSION ON GALLEY MOUNT SUPPORT PLATE AT APPROX FS 295 RBL9. (C-CHECK) 05/20/2018 REPLACED THE GALLEY MOUNT SUPPORT PLATE AT APPROX FS 295 RBL9 IAW SRM.SDR SWIA2018052244706Support Plate · corrodedCORROSION ON WARDROBE MOUNT SUPPORT PLATE AT APPROX FS 310 LBL18. (C-CHECK) 05/20/2018 REPLACED THE WARDROBE MOUNT SUPPORT PLATE AT APPROX FS310 LBL18 IAW SRM.SDR SWIA201642157Frame · damagedR & R FRAME SECTION AT FS 700, STR 5L-5R DUE TO DAMAGE AT APU INSTALLATION TOOLING ATTACH HOLE. R & R FRAME SECTION AT FS 700, STR 5L-5R IAW SRM.SDR SWIA201642158Floor Panel · corrodedCORROSION FOUND ON FLOOR PANEL AT RBL 36 AT FS 439 TO FS 461. CORROSION FOUND ON PRESSURE DECK, FLOOR SILL PANEL AT FS 439 TO FS 461 AT RBL 36 WAS BLENDED ON 4 EA SPOTS IAW REO.SDR SWIA201642155Skin · dentedDENT IN FUSELAGE EXTERIOR SKIN AT FS 677, STR 24R. REPAIRED DENT IN FUSELAGE EXTERIOR SKIN AT FS 677.0, STR 24R IAW STS EA.SDR SWIA201642156Plate · chafedPASSENGER DOOR BOTTOM STEP CLOSEOUT PLATE HAS CHAFING. REPLACED PLATE WITH NEW SERVICABLE PART IAW SRM.SDR SWIA201642154Nose Cowl · dentedLARGE DENT RT ENGINE COWL L/E FWD LOOKING AFT. R & R RT ENGINE NOSE COWL IAW SRM.SDR SWIA201642051Reservoir · failedNOSE GEAR DID NOT EXTEND. RAN QRH, PERFORMED MANUAL EXTENSION. RECEIVED A GREEN NLG ICON. R & R NR 3 HYDRAULIC RESERVOIR IAW AMM. BLED NR 3 HYDRAULIC SYS IAW AMM. PERFORMED EXTENSIONS AND RETRACTIONS IAW AMM, OPS CHECK GOOD. NO LEAKS NOTED.SDR SWIA201541443Unknown · smokeRETURN TO FIELD DUE TO SMOKE IN THE CABIN AND COCKPIT, ALONG WITH LAVATORY SMOKE INDICATION. INSPECTED BOTH ENGINES FOR LEAKS AND LOOSE FITTINGS. INSPECTED LT AND RT PACK DUCTS AND CLAMPS. FOUND NO DEFECTS. PERFORMED POWER ASSURANCE RUNS. OPS CHECKED GOOD.SDR SWIA201437413Skin · chafedRT AILERON UPPER SKIN L/E CHAFED. C-CHECK, R & R RT AILERON UPPER SKIN L/E IAW EA.SDR SWIA201437416Seat Track · corrodedCORROSION FOUND ON SEAT TRACK AT LBL 9 BETWEEN BS 364-399.5. C-CHECK, R & R SEAT TRACK IAW REO.SDR SWIA201437415Seat Track · corrodedCORROSION FOUND ON SEAT TRACK AT RBL 9 BETWEEN BS 364-399.5. C-CHECK, R & R SEAT TRACK, IAW REO.SDR SWIA201437414Hinge · gougedLEFT OTBD FLAP OTBD HINGE ARM ASSY GOUGED BY FOD AT LOWER HINGE BOLT LUG. C-CHECK, REPAIRED LT OTBD FLAP, OTBD HINGE ARM ASSY AT LOWER HINGE BOLT LUG IAW STS EA.SDR SWIA201437428Floor Support · corrodedNUMEROUS AREAS OF CORROSION ON UPPER SURFACE OF RT FLOOR SUPPORT AND DOUBLERS BETWEEN BS 409+128 - 559, RBL 36. C-CHECK, BLENDED OUT CORROSION DAMAGE IAW REO.SDR SWIA201437427Floorbeam · corrodedCORROSION ON UPPER SURFACE OF FLOORBEAM TEE BS 280 FROM LBL 9-RBL 9. C-CHECK, REPLACED IAW REO.SDR SWIA201437426Floor Support · corrodedUPPER SURFACE OF LT FLOOR SUPPORT CORRODED FROM BS 349 - 356, LBL 36. C-CHECK, BLENDED CORROSION IAW REO.SDR SWIA201437425Threshold · corrodedPAX DOOR FWD THRESHOLD CUP CORRODED. C-CHECK, R & R FWD PAX DOOR THRESHOLD CUP IAW SRM.SDR SWIA201437424Threshold · corrodedPAX DOOR AFT THRESHOLD CUP CORRODED. C-CHECK, R & R AFT THRESHOLD CUP IAW SRM.SDR SWIA201437423Floorbeam · crackedLBL 9 INBD AND OTBD ANGLES CRACKED AT FS 280 FLOORBEAM. C-CHECK, REPAIRED IAW REO.SDR SWIA201437422Floorbeam · crackedRBL 9 INBD AND OTBD ANGLES CRACKED AT FS 280 FLOORBEAM. C-CHECK, REPAIRED IAW REO.SDR SWIA201437421Threshold · corrodedPAX DOOR THRESHOLD CORRODED AROUND PROXIMITY SWITCH, UNDER FLOOR AREA, BS 333.SDR SWIA201437420Floorbeam · crackedAFT FLOORBEAM TEE ANGLE IS CRACKED AT BS 280, RBL 9 AND LBL 9. C-CHECK, R & R FLOORBEAM TEE IAW SRM.SDR SWIA201437419Floorbeam · crackedBS 280 FLOORBEAM IS CRACKED AT LBL 11, LOWER TEE. C-CHECK, FLOORBEAM REPAIRED IAW REO.SDR SWIA201437418Floorbeam · crackedBS 280 FLOORBEAM IS CRACKED AT RBL 11, LOWER TEE. C-CHECK, REPAIRED FLOORBEAM IAW REO.SDR SWIA201437417Floorbeam · crackedFS 280 FLOORBEAM IS CRACKED LBL 11 - RBL 11, UPPER TEE. C-CHECK, REPAIRED FLOORBEAM IAW REO.SDR SWIA201437447Angle · crackedANGLE CRACKED AT BS 625, S13L. C-CHECK, R & R ANGLE IAW SRM.SDR SWIA201437446Angle · crackedANGLE AT BS 625 HAS CRACK, STRINGER 13R, C-CHECK, R & R RT ANGLEIAW SRM.SDR SWIA201437445Floor Support · corrodedUPPER SURFACE OF FLOOR SUPPORT DOUBLER CORRODED AT BS 439, LBL 36. C-CHECK, BLENDED OUT CORROSION IAW REO.SDR SWIA201437444Floor Support · corrodedUPPER SURFACE OF FLOOR SUPPORT DOUBLER CORRODED AT BS 449.85, LBL 36. C-CHECK, BLENDED OUT CORROSION IAW REO.SDR SWIA201437443Floor Support · corrodedUPPER SURFACE OF FLOOR SUPPORT DOUBLER CORRODED AT BS 461 LBL 36. C-CHECK, BLENDED OUT CORROSION IAW REO.SDR SWIA201437442Floor Support · corrodedUPPER SURFACE OF FLOOR SUPPORT DOUBLER CORRODED AT BS 473.15, LBL 36. C-CHECK, BLENDED OUT CORROSION IAW REO.SDR SWIA201437441Floor Support · corrodedUPPER SURFACE OF FLOOR SUPPORT DOUBLER CORRODED AT BS 484, LBL 36. C-CHECK, BLENDED OUT DAMAGE IAW REO.SDR SWIA201437440Floor Support · corrodedUPPER SURFACE OF FLOOR SUPPORT DOUBLER CORRODED AT BS 513, LBL 36. C-CHECK, BLENDED OUT DAMAGE IAW REO.SDR SWIA201437439Floor Support · corrodedUPPER SURFACE OF FLOOR SUPPORT DOUBLER CORRODED AT BS 499, LBL 36. C-CHECK, BLENDED OUT DAMAGE IAW REO.SDR SWIA201437438Floor Support · corrodedUPPER SURFACE OF FLOOR SUPPORT DOUBLER CORRODED AT BS 513, LBL 36. C-CHECK, BLENDED OUT CORROSION IAW REO.SDR SWIA201437437Floor Support · corrodedUPPER SURFACE OF FLOOR SUPPORT DOUBLER CORRODED AT BS 525, LBL 36. C-CHECK, BLENDED OUT CORROSION IAW REO.SDR SWIA201437436Floor Support · corrodedUPPER SURFACE OF FLOOR SUPPORT CORRODED AT BS 449, LBL 36. C-CHECK, BLENDED OUT CORROSION IAW REO.SDR SWIA201437435Floor Support · corrodedUPPER SURFACE OF FLOOR SUPPORT CORRODED AT BS 479, LBL 36. C-CHECK, BLENDED OUT CORROSION IAW REO.SDR SWIA201437434Floor Support · corrodedUPPER SURFACE OF FLOOR SUPPORT CORRODED AT BS 486, LBL 36. C-CHECK, BLENDED OUT CORROSION IAW REO.SDR SWIA201437432Door Sill · corrodedNUMEROUS AREAS OF CORROSION AROUND NUTPLATES ON AFT CARGO DOOR SILL, UNDER SIDE FROM BS 574 - 621, LBL 36. C-CHECK, BLENDED OUT CORROSION IAW REO.SDR SWIA201437431Floor Support · corrodedCORROSION ON UPPER SURFACE OF FLOOR SUPPORT AT BS 559+80, RBL 15. C-CHECK, R & R FLOOR SUPPORT IAW SRM.SDR SWIA201437430Seat Track · corrodedCORROSION ON UPPER SURFACE OF SEAT TRACK BS 559+64, RBL 9. C-CHECK, REMOVED SEAT TRACK FROM BS 559+16 - 559+118 AND REPLACED WITH NEW IAW SRM AND EA.SDR SWIA201437429Seat Track · corrodedCORROSION ON UPPER SURFACE OF SEAT TRACK BS 559+50, RBL 9. C-CHECK, REPLACED SEAT TRACK IAW SRM AND EA.
Back to N868CA, cancelled Mar 8, 2023