N883AS, cancelled Dec 26, 2017
Service difficulty reports · 176
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N883AS' AND deregistration_id = 'N883AS-2017-12-26' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N883AS' AND deregistration_id = 'N883AS-2017-12-26' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR ASOA2016072915148Battery Pack · dischargedNR 1 EMERGENCY LIGHT BATTERY PACK DISCHARGED. REMOVED AND REPLACED THE BATTERY PACK IAW AMM 33-51-04. FUNCTIONAL CHECKED GOOD IAW AMM 33-51-04.SDR ASOA2016050814761Lamp · burned outEXTERIOR EMERGENCY LIGHTS OUT AT PASSENGER DOOR, FWD AND AFT LT EMERGENCY EXIT DOOR AND AFT OF SERVICE DOOR. RELAMPED BULBS AT FWD PAX DOOR AFT OF LT EMERGENCY EXIT DOOR, AND AFT OF SERVICE DOOR IAW AMM 33-51-21.SDR ASOA2016030914571Pseu · unserviceableGEAR DISAGREE ON WARNING MESSAGE WITH ASSOCIATED AURAL MSG, GEAR SELECTED DOWN. SHOW BOTH MLG DOWN BUT NLG UP. RAN QRH CYCLED 2 TIMES AND CONDITION WORSEND ALL MML SHOWED UP AND WOULD NO COME DOWN. PERFORMED MANUAL GEAR EXTENSION. ENROUTE, ACFT DIVERTED DUSDR ASOA2016011814383Selector Valve · failedMLG DID NOT EXTEND WHEN LANDING GEAR HANDLE EXTENDED. NOSE GEAR DID EXTEND. RAN QRH AND THE LANDING GEAR EXTENDED WHEN EMERGENCY EXTENTION USED. EMERGENCY ACTIONS, LANDING GEAR RETRACTION SYSTEM. R & R MLG SELECTOR VALVE IAW AMM 32-32-10. AIPC 32-32-10, FIGSDR ASOA2015121514265Frame · crackedPRIOR TO INSTALLING FASTENERS ON FLANGE OF FRAME 319.00 WHICH WERE REMOVED DUE TO CORROSION. MECHANIC FOUND CRACK AT VERY CORNER FASTENER HOLE. COMPLIED WITH EA 20-2015-363 P1. RECEIVED AND COMPLIED WITH FINAL EA 20-2015-363. RECEIVED AND COMPLIED WITH ECTSDR ASOA2015121414264Door Sill · crackedCARGO DOOR CUTOUT LOWER SILL CRACKED AT BS 605. COMPLIED WITH EC/TC REO 601R-53-61-433 AND REO 601R-53-61-433, REV B.SDR ASOA2015121314263Door Sill · crackedCARGO DOOR CUTOUT LOWER SILL CRACKED AT FS 589.00, MARKED. COMPLIED WITH EC/TC REO 601R-53-61-433 AND REO 601R-53-61-433, REV B, DATED 10/9/2009 AS WRITTEN.SDR ASOA2015121014262Seat Track · corrodedSEAT TRACK CORRODED AT LBL9, FS 405 TO 409.00+120. BLENDED CORROSION IAW SRM 51-21-06. FOUND TO BE OUT OF LIMITS IAW SRM 53-21-49. REMOVED SEAT RAIL IAW AMM TASK 53-01-11-000-802. COMPLIED WITH ECTC REO 601R-53-00-485. INSTALLED NEW SERVICEABLE SEAT TRACK SDR ASOA2015120914274Floorbeam · corrodedUPON REMOVING UPPER COMPOSITE CAP FOR FROM ON JOB 8 OP 9 DISCOVERED ADDITIONAL CORROSION ON AFT LT-ANGLE ON 349 CROSSBEAM, RBL 40. REMOVED UPPER SUPPORT ANGLE FROM 349.00 CROSS BEAM REMOVED, 4 EA SOLID RIVETS AND 6 HILITES THROUGH ATTACHING MOUNT IAW SRM 51-4SDR ASOA2015120914261Skin · corrodedWING PLANK HOLE FUEL PANEL 640BB LAND SURROUND HAS CORROSION/PITTING. COMPLIED WITH EC/TC EO 600-57-81 C/W IAW REO 601R-57-21-030, REV L. COMPLIED WITH REO 601R-57-21-2392. RECEIVED AND COMPLIED WITH ECTC REO 601R-57-21-2392.SDR ASOA2015120914260Skin · corrodedWING PLANK ACCESS HOLE FOR FUEL PANEL 540BB LAND SURROUND HAS CORROSION PITTING. COMPLIED WITH ECTC EO 000-57-81.SDR ASOA2015120714259Frame · crackedFRAME 333, CRACKED AT STR 1 RT. RECEIVED AND COMPLIED WITH 601R-53-21-2680 PI. REMOVED FRAME AND STARTED DRILLING NEW FRAME IAW SRM 51-42-06 & 51-42-21. DRILLED AND INSTALLED FRAME 333 AT SIGN RT IAW SRM 51-41-11 AND 51-42-06, & 51-42-21 AND DWL 601R 32004. SDR ASOA2015120514258Floor Support · corrodedCORROSION FOUND ON RT FLOOR SILL BETWEEN FS 559.00+16 & 559.00+32 NEED TO BE EVALUATED. COMPLIED WITH EC/TC REO 601R-53-00-526-01.SDR ASOA2015120514257Floor Support · corrodedCORROSION FOUND ON LT FLOOR SILL BETWEEN FS 559.00+32 & 559.00+80, NEED TO BE EVALUATED. COMPLIED WITH EC/TC REO 601R-53-00-526.SDR ASOA2015120514256Floor Support · corrodedRIGHT PRESSURE FLOOR SILL CORRODED AT SEVERAL LOCATIONS BETWEEN FS 409 & FS 559. COMPLIED WITH EC/TC REO 601R-53-41-666-01 AND REO 601R-53-41-666, REV C, DATED 11/6/12 AS WRITTEN.SDR ASOA2015120514255Floor Support · corrodedLEFT PRESSURE FLOOR SILL CORRODED AT SEVERAL LOCATIONS BETWEEN FS 409 & FS 559. COMPLIED WITH EC/TC REO 601R-53-41-666-01, REV A, DATED OCT.23,2013.SDR ASOA2015120514254Angle · crackedANGLE CRACKED AT FS 280 AND RBL 9. R & R ANGLE WITH SRM 51-42-21-00.SDR ASOA2015120514197Seat Track · corrodedSEAT TRACK AT RBL9 BETWEEN FS 559.00 & 559.00+96 HAS CORROSION THAT NEED TO BE EVALUATED. SEAT TRACK FOUND TO BE OUT OF LIMITS IAW SRM 53-51-49-01. R & R SEAT TRACK SECTION AT RBL9, FS 559 AND 559.00+86 IAW AMM 53-01-11-000-802 AND 53-01-11-400-802 AND FABRISDR ASOA2015120514196Seat Track · corrodedSEAT TRACK AT LBL9 BETWEEN FS 559.00 & 559.00+96 HAS CORROSION THAT NEED TO BE EVALUATED. SEAT TRACK FOUND TO BE OUT OF LIMITS IAW SRM 53-51-49-01. REMOVED SEAT TRACK AT LBL9 BETWEEN FS 559.00 AND 559.00+96 IAW AMM 53-01-11-000-802. COMPLIED WITH EC/TC REO SDR ASOA2015120514195Seat Track · corrodedSEAT TRACK AT LBL BETWEEN FS 605.00 & 621.00 HAS CORROSION THAT NEED TO BE EVALUATED. REMOVED SEAT TRACK AT LBL BETWEEN FS 605.00 AND 621.00 IAW AMM 53-00-49-000-801. INSTALLED SEAT TRACK AT LBL BETWEEN FS 605.00 & 612.00 IAW AMM 53-01-11-400-802. COMPLIED SDR ASOA2015120514194Seat Track · corrodedSEAT TRACK AT RBL 9 BETWEEN FS 574.00 & 559.00+112 HAS CORROSION THAT NEED TO BE EVALUATED. SEAT TRACK FOUND TO BE OUT OF LIMITS IAW SRM 53-51-49-01. REMOVED SEAT TRACK AT RBL 9 BETWEEN FS 574.00 AND 559.00+112 IAW AMM 53-00-49-000-801. COMPLIED WITH EC/TC RSDR ASOA2015120514193Seat Track · corrodedSEAT TRACK AT LBL9 BETWEEN FS 574.00 & 559.00+112 HAS CORROSION THAT NEED TO BE EVALUATED. SEAT TRACK FOUND TO BE OUT OF LIMITS IAW SRM 53-51-49-01. REMOVED SEAT RAIL AT LBL9 BETWEEN FS 574.00 AND 559.00+112 IAW AMM 53-00-48-000-801. COMPLIED WITH EC/TC REO SDR ASOA2015120514192Seat Track · corrodedDEFECT DESCRIPTION: SEAT TRACK AT RBL9 BETWEEN FS 559.00+80 & 559.00+96 HAS CORROSION THAT NEED TO BE EVALUATED. SEAT TRACK FOUND TO BE OUT OF LIMITS IAW SRM 53-51-49-01. REMOVED SEAT TRACK AT RBL9 BETWEEN FS 559.00 AND FS 559.00+96 IAW AMM 53-00-49-000-801. SDR ASOA2015120514191Seat Track · corrodedSEAT TRACK AT LBL9 BETWEEN FS 559.00+80 & 559.00+96 HAS CORROSION THAT NEED TO BE EVALUATED. SEAT TRACK FOUND TO BE OUT OF LIMITS IAW SRM 53-51-49-01, REMOVED AND REPLACED. REMOVED SEAT RAIL AT LBL9 BETWEEN FS 559+80 AND 559+96 IAW AMM 53-00-48-000-801. COMSDR ASOA2015120514190Seat Track · corrodedSEAT TRACK AT LBL18 BETWEEN FS 559.00+80 & 559.00+96 HAS CORROSION THAT NEED TO BE EVALUATED. SEAT TRACK FOUND TO BE OUT OF LIMITS IAW SRM 53-51-49-01. R & R SEAT TRACK AT LBL 18 BETWEEN 559+80 AND 559+96 IAW AMM 53-01-11-000-802 AND 53-1-11-400-02 AND FABRISDR ASOA2015120514189Seat Track · corrodedSEAT TRACK SEGMENT CORRODED ON RBL 9 FROM BS 409 TO 409+128 IN 6 SPOTS. COMPLIED WITH EC/TC REO 601R-53-00-485 FABRICATED SEAT TRACK IAW GREO 601R-53-00-485, REV A. FOUND TO BE OUT OF LIMITS IAW SRM 53-21-49. REMOVED AND REPLACED THE SEAT TRACKIAW AMM 53-0SDR ASOA2015120414253Floor Support · corrodedRIGHT FLOOR SILL CORRODED AT FS 319.70. R & R ANGLE DOUBLER ON RT FLOOR SILL AT FS 319.70 IAW SRM 31-42-06 AND SRM 51-42-13 AND SRM 51-42-15.SDR ASOA2015120414252Floor Support · corrodedLBL9 FLOORBEAM FROM FS 405 TO 409.00+120 IS CORRODED AT FS 410 AND FS 409.00+120. AFTER EVALUATION ITS DISCOVERED THAT DAMAGE IS OUT OF LIMITS WITH SRM AND SPLICE REPAIRS ARE REQUIRED. REPAIRED FLOORBEAM AT LBL9, FWD SPLICE FS 409+26-409+5 AND AFT SPLICE FS SDR ASOA2015120414251Floor Support · corrodedRBL 9 FLOORBEAM TOP CAP CORRODED BETWEEN FS 409 TO FS 409+96 IN 10 SPOTS MOSTLY AROUND SCREW HOLES. REMOVED SEAT RAIL FORM FS 409-FS 409+112. INSTALLED SEAT RAIL FS 409-40-+112 IAW AMM 53-01-11-40-802. BLENDED & REMOVED CORROSION SRM 51-123-00-00 IN 11 LOCASDR ASOA2015120414250Attach Fitting · crackedBROKEN CLEAT AT FS 484.00 & RBL 28 INTERSECT NEED REPLACEMENT. REMOVED BROKEN CLEAT AT FS 484.00 & RBL 28 INTERSECT IAW SRM 51-42-21. INSTALLED SERVICEABLE CLEAT IAW SRM 51-42-21, DWG 601R31171.SDR ASOA2015120414188Seat Track · corrodedCORROSION ALONG RT SIDE SEAT TRACK BETWEEN BS 449+85 TO 499, COMPLIED WITH EC/TC REO 601R 53-00-055. REMOVED RT SIDE SEAT TRACK IAW AMM 53-01-11-000-802. INSTALLED RT SIDE SEAT TRACK IAW AMM 53-01-11-400-802.SDR ASOA2015120414187Seat Track · corrodedCORROSION ON RT SIDE SEAT TRACK FROM BS 409+128 - 461. COMPLIED WITH EC/TC REO 601R-53-00-055. REMOVED RT SIDE SEAT TRACK IAW AMM 53-01-11-000-802. INSTALLED RT SIDE SEAT TRACK IAW AMM 53-01-11-000-802.SDR ASOA2015120414186Seat Track · corrodedCORROSION ON LT SIDE SEAT TRACK BETWEEN FS 544.00 & 559.00+80. COMPLIED WITH EC/TC REO 601R-53-00-055. REMOVED SIDE SEAT TRACK IAW AMM TASK 53-01-11-000-802. INSTALLED A NEW SEAT TRACK IAW AMM 53-01-11-400-802.SDR ASOA2015120414181Isolator · brokenAFT PRESSURE BULKHEAD FWD FACE, SEVEN BROKEN INSOLATORS. R & R ISOLATORS IAW SRM 51-42-10.SDR ASOA2015120214249Skin · crackedCRACK FOUND IN WING PLANK ON LT SIDE AT 148.019, AFT SIDE LOWER PLANK, LENGTH .718. COMPLIED WITH EC/TC REO 601R-57-21-130 & GREO 601R-57-21-130, REV DATED 11/27/2013 AS WRITTEN. COMPLIED WITH EC/TC REO 601R-57-21-131 & GREO 601R-57-21-131, REV DATED 11/27/2SDR ASOA2015120214248Fitting · chafedFITTING CHAFED ON FS 364.00 FWD OF THE AVIONIC DOOR, 2EA. REMOVED CHAFE AT FS 364.00 FITTINGS FWD OF THE AVIONICS DOOR, 2EA IAW SRM 51-12-00-00, BLEND LENGTH 1.3" X .5". COMPLIED WITH STS EA 26-2015-203, REV A DATED 12/16/2015. RECEIVED AND COMPLIED WITH ECTSDR ASOA2015120114266Skin · dentedDENT ON RT WING L/E NEAR WING ROOT, REF AFDL FOR INTERM REPAIR IAW STS EA 25-2014-051, PERMANENT REPAIR REQUIRED. DENT ON RT WING L/E NEAR WINGROOT REPAIRED. NO DEFECTS NOTED. RECEIVED DISPOSITION AND COMPLIED WITH EA 26-2015-199. REMOVED L/E INNER SKIN SDR ASOA2015110113989Support Angle · damagedEXT POWER RECEPTACLE AFT SUPPORT ANGLE DAMAGED. REMOVED DAMAGE BRACKET. DRILLED UP NEW BRACKET IAW REO 601R-53-11-009. INSTALLED THE SUPPORT ANGLE IAW REO 601R-53-11-009. REPAIR CLASSIFIED AS MAJOR REPAIR IAW GMM 5-3.SDR ASOA2015110113988Bracket · damagedEXT POWER RECEPTACLE SUPPORT BRACKET DAMAGE. REMOVED DAMAGE BRACKET. DRILLED UP NEW BRACKET IAW REO 601R-53-11-009. INSTALLED THE BRACKET IAW REO 601R-53-11-009. REPAIR CLASSIFIED AS MAJOR IAW GMM 5-3.SDR ASOA2015110113987Plate · damagedEXT POWER RECEPTACLE DAMAGE. FABRICATED JOGGLE PLATE IAW REO 601R-53-11-009. INSTALLED IAW REO 601R-53-11-009. MAJOR REPAIR IAW GMM 5-3.SDR ASOA2015062613178Glowstrip · deterioratedPHOTOLUMINESCENT FROM ROW 1CD TO ROW 8CD WATER DAMAGED. R & R PHOTOLUMINESCENT INSERT FROM ROW 1CD TO ROW 8CD IAW STC ST02687AT.SDR ASOA2015031812416Wire · damagedLIGHTED FLOOR-LEVEL EXIT SIGN INOPERATIVE LT SIDE OF GALLEY. R & R WIRE SPLICE CONNECTOR IAW SPM 20-17-31. SYSTEM OPS CHECKED GOOD. NO FURTHER ACTION.SDR ASOA2014110711613Windshield · failedF/O WINDSHIELD BEGAN ARCING AND SMALL CRACK, RAN QRH PROCEDURE 11-14, WINDSHIELD SHATTERED ONE MINUTE LATER. REMOVED AND REPLACED THE F/O'S WINDSHIELD IAW AMM 56-11-01. OPS AND LEAK CHECKED GOOD. ACFT OK FOR SERVICE.SDR ASOA2014081211037Light · inoperativeEMERGENCY LIGHT BELOW F/A JUMPSEAT IS INOPERATIVE AND ITS WIRING HARNESS IS NOT TIED DOWN. R & R THE LIGHT IAW AMM 33-51-10.SDR ASOA2014080611008Bulb · burned outRIGHT FORWARD EXTERNAL EMERGENCY LIGHT IS INOPERATIVE. R & R RT FWD EXTERNAL EMERGENCY LIGHT BULB IAW AMM 33-51-21. OPS CHECKED GOOD.SDR ASOA2013121709653Fitting · damagedRT MLG FWD DOOR SPACER FITTING HAS ELONGATED HOLE ON FUSLAGE SIDE. REPAIRED IAW EC/TC REO 601R-57-21-2059. MAJOR REPAIR.SDR ASOA2013121309626Light · unserviceableNUMEROUS COMPONENTS OF THE EMERGENCY TRACK LIGHTS FOUND UNSERVICEABLE. INSTALLED SERVICEABLE COVERS IAW ASA 33-51-00 SUPPLEMENT AND SAFETGLO MM 41-10, 33-60-10.SDR ASOA2013121309625Floor Support · corrodedMINOR CORROSION FOUND AROUND FASTENER HOLES ALONG RT FLOOR SUPPORT RBL 17 BETWEEN BS 559 + 48 TO FS 559 + 112. REPAIRED FLOOR SUPPORT IAW GREO 601R-53-00-526 AND EC/TC REO601R-53-00-526. MAJOR REPAIR.SDR ASOA2013121309624Seat Track · corrodedSEAT TRACK BS 364 TO 394, RBL 9 CORRODED IN VARIOUS AREAS. R & R SEAT TRACK IAW AMM 53-01-11-000-802 AND 53-01-11-400-802.SDR ASOA2013121309623Seat Track · corrodedSEAT TRACK BS 364 TO 394, LBL 9 IS CORRODED IN VARIOUS PLACES. R & R SEAT TRACK IAW AMM 53-01-11-946-003 AND 53-01-11-420-001.
Back to N883AS, cancelled Dec 26, 2017