N8905F, cancelled Feb 8, 2025
Service difficulty reports · 74
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N8905F' AND deregistration_id = 'N8905F-2025-02-08' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N8905F' AND deregistration_id = 'N8905F-2025-02-08' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR REXA2017122001266Hose · damagedPORTABLE OXYGEN BOTTLE 4LMP MASK HOSE DAMAGED. REMOVED AND REPLACED THE MASK ASSEMBLY.SDR REXA2017120501225Oxygen Mask · leakingCREW O2 LOW, WAS REFILLED THIS MORNING AND IS BELIEVED TO BE LEAKING. FOUND CAPT'S AND FO'S MASKS TO BE LEAKING. R&R CAPT'S AND FO'S CREW OXYGEN MASKS IAW AMM 35-11-12. NO LEAKS NOTED. OK FOR SVC.SDR REXA2017112201190Control Unit · faultedFLAP FAILED ON TAKEOFF CAUTION. DIVERTED. RT WINDOW HEAT CAUTION. PERFORMED TROOBLESHOOTING IAW FIM REV 53. R & R FECU IAW AMM 27-51-05. OPS CHECKED GOOD. RT WINDOW HEAT OPS CHECKED GOOD IAW AMM 30-41-01.SDR REXA2017102001114Oxygen Mask · leakingOXYGEN LOW PRESSURE CAUTION MESSAGE, 1410 PSI. LEAK CHECKED THE CREW OXYGEN SYSTEM AND FOUND THE LEFT PILOT OXYGEN MASK LEAKING. REMOVED AND REPLACED THE OXYGEN MASK IAW AMM 35-11-12. OPS CHECKED GOOD. OXYGEN PSI HOLDING AFTER 4 HOURS.SDR REXA2017090700983Switch · malfunctionedTHE EXIT LIGHT BY THE SIDE DOOR AT ROW 8 LEFT INOPERATIVE. CYCLED F/A EMERGENCY LIGHT SWITCH AND COCKPIT PANEL SWITCH. ALL CHECKED GOOD IAW AMM 33-50-00.SDR REXA2017090700982Switch · malfunctionedEMERGENCY LIGHT INOPERATIVE. CYCLED F/A EMERGENCY LIGHT SWITCH, AND THE COCKPIT PANEL SWITCH. ALL CHECKED GOOD IAW AMM 33-50-00.SDR REXA2017011100024Elt · no testELT FAILED OPERATIONAL CHECK. R & R THE ELT IAW AMM 25-62-01 OPS CHECKED GOOD.SDR REXA2017011000083Light · inoperativeROW 1-5 CD EMERGENCY LIGHTS INOPERATIVE. R & R THE CABLE ASSY AND LAMP IAW AMM 33-51-01. OPS CHECKED GOOD.SDR REXA2016123002542Oxygen Mask · defectiveFO O2 MASK RELEASE O2 WHILE LEFT 02 DOOR IS OPEN. REMOVED AND REPLACED FO O2 MASK IAW AMM 35-11-12. OPS CHECK GOOD. NO OTHER DEFECTS NOTED AT THIS TIME.SDR REXA2016121702553Bpsu · inoperativeFLAPS FAIL CAUTION MESSAGE. FLAPS IN 0 POSITION. R & R LEFT BPSU IAW AMM 27-51-10 OPS CHECK GOOD.SDR REXA2016120902468Flashlight Assy · inoperativeWHILE REMOVING CAPTAINS BROKEN FLASHLIGHT SEAL FOUND THAT BLINKING RED LIGHT WAS INOPERATIVE. REMOVED AND REPLACED
FLASHLIGHT AND HOLDER ASSEMBLY AND PERFORMED OP'S CHECKSDR REXA2016082401606Light · malfunctionedEMERGENCY FLOOR TRACK LIGHTING NOT WORKING ROW 2 TO ROW 5. RESET ACFT POWER, PERFORMED OPS CHECK OF EMERGENCY LIGHTS NO DEFECT NOTED IAW AMM 33-51-00SDR REXA2016080701485Battery Pack · dischargedEMERGENCY LIGHTS NOT COMING ON WITH SWITCH IN THE ON POSITION FROM FLT DECK OVERHEAD PANEL OR FLT ATTENDANT'S PANEL. DURING FFOD CHECK.
LET BATTERIES FULLY CHARGE ON EXTERNAL POWER. PERFORMED OPS CHECK OF EMERGENCY LIGHTS IAW AMM 33-51-00. OPS CHECKED GOOD. SDR REXA2016072901429Light · malfunctioned6 ROWS OF EMERGENCY FLOOR LEVEL LIGHTING STRIP IS SLOW TO ILLUMINATE WHEN COLD WORKS FINE AFTER STRIP IS WARMED UP. PERFORMED OPS CHECKED OF EMERGENCY FLOOR LEVEL LIGHTING, OPS CHECKED GOOD IAW AMM 33-51-01. ACFT OK FOR SERVICE.SDR REXA2016072601405Smoke Warning · false activationSMOKE ALARM SOUNDED FOR NO REASON AND NOW FAILS TO TEST PROPERLY. UNABLE TO DUPLICATE. OPS CHECKED GOOD IAW MM 26-16-01.SDR REXA2016062701189Oxygen Mask · no testOBSERVERS MASK FAILS TEST. REPLACED OXYGEN MASK STORAGE BOX IAW 35-11-12. OPS & LEAK CHECKED GOOD.SDR REXA2016061701107Connector · disconnectedEMERGENCY EXIT FLOOR TRACK LIGHTING ROWS 2-5 INOPERATIVE. RECONNECT, RESEATED EMERGENCY EXIT FLOOR LIGHT CONNECTORS, ALL LIGHTS OPS CHECK GOOD IAW AMM 33-51-00.SDR REXA2016033000446Light · inoperativePASSENGER CALL LIGHT IN EMER EXIT SIGN ON CEILING IS NOT WORKING, WHEN CALL BUTTON PUSHED. R & R LIGHT BULB ON PAX OVERHEAD CALL SIGN IAW AMM 33-51-14. OK FOR SERVICE.SDR REXA2015112101201Stop Fitting · brokenPANEL 594JB HAS BUTE DOOR STOP TAB BROKEN OFF THE END OF THE PANEL. REMOVED THE BROKEN DOOR STOP AT PANEL 594JB IAW SRM 51-42-06. RECEIVED NEW DOOR STOP, PN 600-10196-15. INSTALLED TO PANEL 594JB IAW SRM 51-42-06. WORK SUMMARY STATEMENT REQUIRED. R & R DSDR REXA2015112101200Seat Track · corrodedLEFT SIDE SEAT RAIL FROM FS 364 TO FS 409.00+16, HAS SEVERAL AREAS OF CORROSION. R & R LT PAX SEAT RAIL, PN 601R38312-31, FROM FS 364 TO 409.00+18.02 IAW AMM 53-61-11-000 400-802.SDR REXA2015112101199Mount Bracket · crackedRIGHT FLAP STUB FAIRING, FWD MOUNT BRACKET IS CRACKED. LOCATED, DRILLED & INSTALLED NEW FWD MOUNT BRACKET, PN 601R31199-6 IAW SRM 51-40-11 & 51-42-06 ON RT FLAP STUB FAIRING.SDR REXA2015112101198Fairing · chafedLEFT STUB FAIRING CHAFED ON AFT END APPROX 1" WIDE BY 1" HIGH BY .008 DEEP. R & R WITH NEW SERVICEABLE OUTER LT FLAP STUB FAIRING SKIN, PN 601R31199-89, UPPER SEAL PN 601R31199-81, LOWER SEAL PN 601R31199-99, BRACKET PN 610R31199-5, HINGE HALF PN 601R31199-21SDR REXA2015112101197Seat Track · corrodedRIGHT SIDE SEAT RAIL FROM FS 444.02 TO FS 495.98, HAS SEVERAL AREAS OF CORROSION. R & R NEW SEAT RAIL FROM RFS 444.02 TO 495.98, PN 601R38312-115S, IAW AMM 53-01-11-400-802.SDR REXA2015112101196Seat Track · corrodedRIGHT SIDE SEAT RAIL FORM FS 364 TO FS 409.00+16, HAS SEVERAL AREAS OF CORROSION. REMOVED RT SIDE SEAT RAIL, PN 601R38312-031S, FROM RFS 364 TO 409+16 IAW AMM 53-01-11. RECEIVED RT SIDE SEAT RAIL 601R38312-31, INSTALLED TO RFS 364 - 409+16 IAW AMM 53-01-11-4SDR REXA2015112101194Post · damagedFS 409 & 128, RBL 18, INBD & OTBD VERTICAL POSTS HAVE INDICATIONS NOTED IN THE AFT FLANGE RADIUS AT WL 69, APPROX 0.250" LONG BY GREATER THAN 50% FSH. BOTH INDICATIONS FAILED NDT INSPECTION. REMOVED OVERBOARD EXHAUST VLV IAW QMM 21-24-34-000-401. INSTALLED SDR REXA2015112101193Power Cable · defectiveFIRST LIGHT ON CABIN FLOOR TRACK IS NOT WORKING. REPLACED UNSERVICEABLE CABLE ASSEMBLY AT FWD CONNECTION WITH NEW CABLE ASSEMBLY IAW ESPM 20-17-10. OPERATIONS CHECKED GOOD.SDR REXA2015071600718Ram Air Turb · deployedRAM AIR TURBINE DEPLOYED JUST AFTER WEIGHT OFF WHEELS. RETURNED & LANDING WITHOUT INCIDENT. PERFORMED ADG DEPLOYMENT, INFLIGHT, INSP IAW AMM 05-51-19 & SB ERPS10AG-24-3 REV 3 INSPECTION GOOD. NO DEFECTS FOUND. COMPONENT WAS REPLACED AT MOTR REQUEST, ADG COSDR REXA2015020800189Light · inoperativeEMERGENCY LIGHT ABOVE RIGHT WING INOPERATIVE, FIRST LIGHT. R & R EMER LIGHT BULB IAW AMM 33-51-21. OPERATIONS CHECKED GOOD.SDR REXA2014092901006Life Vest · unserviceableONE INFANT LIFE VEST & OBSERVERS LIFE VEST BAGS TORN. R & R ONE INFANT LIFE VEST & ONE OBSERVERS LIFE VEST IAW AMM 25-61-03 & PA 25-096A.SDR REXA2014092500994Door Seal · lack of lubeLOUD PRESS SQUEAL COMING FROM MAIN CABIN DOOR IN FLIGHT. INSPECTED & LUBED SEAL & PERFORMED PRESS CHECK IAW AMM 21-32-00. OPERATIONS & PRESS CHECKED GOOD AT THIS TIME.SDR REXA2014062700638Light · inoperativeROW 8 EMER ELECTROLUMINESCENT FLOOR LIGHT INOPERATIVE. R & R FLOOR LIGHT STRIP IAW AMM 33-51-01. OPERATIONS CHECKED GOOD.SDR REXA2014061900613Shroud · crackedEMERGENCY EXIT LIGHT LENS SHROUD IS CRACKED ON WARDROBE. R & R EMER LIGHT FLOOR LEVEL FLOOD LIGHT ASSEMBLY ON WARDROBE IAW AMM 33-51-19. OPERATIONS CHECKED GOOD IAW AMM 33-51-00-710-801.SDR REXA2014061900612Battery Pack · inoperativeTHE NR 1 EMER LIGHT BATTERY PACK IS INOPERATIVE. R & R NR 1 EMER LIGHT BATTERY PACK IAW AMM 33-51-04. OPERATIONS CHECKED GOOD IAW AMM 33-51-04-740-801.SDR REXA2014061900611Insulation · out of positionRIGHT EMER DOOR HAS INSULATION AROUND PULL HANDLE THAT STOPS HANDLE FROM OPENING ALL THE WAY. REMOVED INSULATION FROM RT EMER EXIT DOOR PULL HANDLE THUS PERMITTING HANDLE TO OPEN ALL THE WAY IAW AMM 52-21-00.SDR REXA2014061900604Battery Pack · inoperativeTHE NR 4 EMER LIGHT BATTERY PACK IS INOPERATIVE. R & R NR 4 EMER LIGHT BATTERY PACK IAW AMM 33-51-04. OPERATIONS CHECKED GOOD IAW AMM 33-51-04-740-801.SDR REXA2014061900603Lens · crackedGALLEY EMER EXIT & VENT PANEL HAS A CRACKED EMER LIGHT LENS & SHROUD. R & R GALLEY EMER LIGHT ASSEMBLY IAW 200 AMM 33-51-10. OPERATIONS CHECKED GOOD IAW AMM 33-51-00-710-801.SDR REXA2014061200478Skin · corrodedRIGHT WING LOWER PLANK ACCESS HOLES FOR PANELS 640EB & 640DB CORRODED. REPAIRED IAW REO 601R-57-21-030.SDR REXA2014061200477Skin · corrodedRIGHT WING LOWER ACCESS HOLES FOR PANELS 650EB & 650DB CORRODED. REPAIRED IAW REO 601R-57-21-030.SDR REXA2014061200476Skin · corrodedRIGHT WING LOWER PLANK ACCESS HOLE FOR PANEL 640BB CORRODED. REPAIRED IAW REO 601R-57-21-030.SDR REXA2014061200472Skin · corrodedCORROSION ON THE PANEL LANDING FOR PANELS 540AT, 540BT & 540CT ON THE LT UPPER WING SKIN AT WS 74.15, WS 96.34 & WS114.27.SDR REXA2014061200471Skin · corrodedCORROSION ON THE PANEL LANDING FOR PANELS 640AT, 640BT & 640CT ON THE RT UPPER WING SKIN AT WS 74.15, WS 96.34 & WS 114.27. REPAIRED IAW EA CRJ257-02626.SDR REXA2014061000470Skin · corrodedLEFT WING PLANK ACCESS HOLES FOR PANEL 510AB & 540BB CORRODED. REPAIRED IAW REO 601R-57-21-030.SDR REXA2014060900467Web · crackedFS 280 WEB CRACKED OTBD OF LBL 9 & RBL 9. REPAIRED IAW REO 601R-53-11-171 & 601R-53-11-136.SDR REXA2014060300465Fitting · crackedFS 280 RBL 9 OTBD CLIP CRACKED & AFT FLOOR ANGLE CORRODED. REPAIRED IAW REO 601R-53-11-136.SDR REXA2014060600464Hinge Fitting · gougedRIGHT INBD FLAP INBD HINGE ARM GOUGED ON LOWER FWD & AFT OTBD SIDE. REPAIRED IAW REO 601R-57-54-259.SDR REXA2014060600463Beam · chafedBL0 VERTICAL BEAM CHAFED FROM 10TH STAGE ISO VLV. REPAIRED IAW REO 601R-53-61-1523 & 601R-53-61-5286.SDR REXA2014060400461Bulkhead · scratchedFS 621 TOP LT CORNER NEAR J6CD CONNECTOR HAS FOUR SCRATCHES IN BULKHEAD. REPAIRED IAW REO 601R-53-61-2155.SDR REXA2014032000309Cover · looseEMERGENCY LIGHTING STRIP ON 1CD LOOSE. SECURED EMERGENCY FLOOR PATH LIGHTING COVER IAW AMM 33-51-01. ALL CHECKED GOOD.SDR REXA2014022800250Cap · missingAFT CEILING EXIT SIGN FWD & AFT EMERGENCY LIGHT CAP COVERS MISSING. R & R AFT EXIT SIGN WHITE LIGHT CAPS IAW AMM 33-20-00. OPS CHECKED GOOD.SDR REXA2014021700210Cover · brokenEMERGENCY FLOOR STRIP LIGHTING ROW 1C - D PLASTIC COVER ABOUT 2 FEET LONG BROKEN & THE EMERGENCY FLOOR STRIP EXPOSED. REPLACED EMERGENCY FLOOR TRACK LIGHT COVER FROM ROWS 1C - D THRU 5C - D. ALL CHECKED GOOD IAW REF CRJ 200 AMM CH 33-51-00.