N892GA, cancelled Dec 15, 2018
Service difficulty reports · 38
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N892GA' AND deregistration_id = 'N892GA-2018-12-15' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N892GA' AND deregistration_id = 'N892GA-2018-12-15' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR WX0A2015111272993Battery · dischargedUPPER FWD CABIN EMER FLASHLIGHT DOES NOT BLINK. REPLACED BATTERY FOR FWD UPPER CABIN EMER FLASHLIGHT IAW MM 25-60-00. OPERATIONS CHECKED GOOD.SDR WX0A2015092472888Jackscrew · wornWHILE PERFORMING OKAY TO INSTALL ON HORIZONTAL JACKSCREW, MOUNTING HARDWARE WORN & GIMBAL PINS WORN. INSTALLED NEW MOUNTING HARDWARE & GIMBAL PINS ON NEW JACKSCREW IAW AMM 27-40-01.SDR WX0A2015071572732Control Panel · faultyWHEN ENGAGING THE AUTOPILOT USING EITHER DFGC 1 OR 2, ACFT PITCHES UP & DOWN ABRUPTLY BEFORE STABILIZING. R & R FLIGHT CONTROL PANEL IAW AMM 22-01-02, TEST GOOD. PERFORMED RTS TEST, GO ON BOTH 1 & 2, RTS TESTED GOOD IAW AMM 22-01-05.SDR WX0A2015021672422Battery · dischargedFOUND ON WAKE UP, TAIL CONE LOWER EMER LIGHT INOPERATIVE. REPLACED BATTERIES FOR POWER SUPPLY IAW AMM 33-53-01. OPERATIONS CHECKED GOOD.SDR WX0A2014102672221Skin · corrodedLEFT WING LOWER SKIN STATION YCW 150.0 IS CORRODED. REMOVED DAMAGED AREA, FABRICATED FILLER & REPLACED MLG SUPPORT DOUBLER IAW SB 80-57-239 REV 2 DATE 8/20/2013 WORK ORDER 234001 M301 NR 79 & WORK ORDER 1011325 5000-0002.SDR WX0A072219Cusp Web · corrodedPASSENGER CABIN RT CUSP WEB BETWEEN STATION 484 - 503 CORRODED. REMOVED DAMAGE AREA, FABRICATED REPAIR PARTS & INSTALLED IAW SRM 53-05 FIG 131A-8 234001 M301 NR 356 WORK ORDER 1011325 2400-0196.SDR WX0A2014101772213Cusp Web · corrodedCUSP WEB CORRODED AT STATION 834 RT SIDE. REPAIRED CUSP WEB IAW SRM 53-05 FIG 131A-13 SHEET 1.SDR WX0A2014101772207Cusp Web · corrodedLEFT PAX CABIN CUSP WEB CORRODED BETWEEN STATION 1212 TO 1231. REPAIRED CUSP WEB IAW SRM 53-05 FIG 131.SDR WX0A2014101772206Cusp Web · corrodedLEFT PAX CABIN CUSP WEB CORRODED BETWEEN STATION 1231 TO 1250. REPAIRED CUSP WEB IAW SRM 53-05 FIG 131.SDR WX0A072002Light · inoperativeFOUND ON WAKE UP, TAIL SLIDE EMER LIGHT BULB, BOTTOM OF 3 INOPERATIVE. RE LAMPED TAIL SLIDE EMER LIGHT AS REQUIRED. OPERATIONS CHECKED GOOD IAW AMM 33-53-01.SDR WX0A071994Battery · dischargedFWD FLIGHT ATTENDANT JUMP SEAT FLASHLIGHT INOPERATIVE. R & R FLASHLIGHT BATTERY IAW AMM 25-60-00.SDR WX0A071809Battery · dischargedAFT FLIGHT ATTENDANT`S FLASHLIGHT INOPERATIVE. R & R AFT FLIGHT ATTENDANT`S FLASHLIGHT BATTERY IAW AMM 25-60-00, OPERATIONS CHECKED GOOD.SDR WX0A071596Frame · corrodedAFT CARGO FRAME AT STATION 1309 CORRODED BETWEEN LONGERON L24R TO 24L. REPAIRED FRAME.SDR WX0A071591Frame · crackedLEFT FUSELAGE AT STATION 1474 CANT FRAME CRACKED. REPAIRED LEFT FUSELAGE AT STATION 1474 CANT FRAME.SDR WX0A071590Frame · crackedAFT FUSELAGE CANTED FRAME AT STATION 1463 UPPER LEFT SIDE WEB CRACKED. REPAIRED CANTED FRAME WEB.SDR WX0A071589Skin · dentedLEFT ELEVATOR CONTROL TAB HAS A DENT ON LOWER I/B SURFACE. REPAIRED DENT.SDR WX0A2013051371579Thrust Reverser · dentedNR 2 ENGINE T/R LOWER CLAM SHELL DENT AT 3RD RIB. LENGTH 5.2 WIDTH 2.8 DEPTH .033 D/X RATIO OF 84.8 FOUND TO BE WITHIN LIMITS.SDR WX0A071578Skin · dentedUPPER LEFT FUSELAGE SKIN DENT STATION 218 LONGERON 3L. LENGTH 1.5 DEPTH .018 D/X RATIO OF 83.3. FOUND TO BE WITHIN LIMITS.SDR WX0A071486Battery Pack · dischargedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE POWER SUPPLY BATTERY PACK AND MADE ASDR WX0A071018Battery · dischargedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE BATTERIES IN THE POWER SUPPLY BATTERSDR WX0A070954Battery · dischargedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE BATTERIES IN THE POWER SUPPLY BATTERSDR WX0A070953Battery · dischargedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE BATTERIES IN THE POWER SUPPLY BATTERYSDR WX0A070760Battery · dischargedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE BATTERIES IN THE POWER SUPPLY BATTERSDR WX0A070539Battery · dischargedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE BATTERIES IN THE POWER SUPPLY BATTERSDR WX0A070516Battery · dischargedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE BATTERIES IN THE POWER SUPPLY BATTERSDR WX0A070321Battery Pack · inoperativeDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE BATTERIES IN THE POWER SUPPLY BATTERSDR WX0A070235Battery Pack · failedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSP, MAINT REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINT REMOVED AND REPLACED THE APPROPRIATE BATTERIES IN THE POWER SUPPLY BATTERY PACK. A SATISFACTORY OPERATIONAL CHECK WAS ACCOSDR WX0A070233Battery Pack · failedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSP, MAINT REPORTED A PROTION OF THE EMERGENCY EVACUATION LIGHTING SYS WOULD NOT TEST. MAINT REMOVED AND REPLACED THE APPROPRIATE BATTERIES IN THE POWER SUPPLY BATTERY PACK. A SATISFACTORY OPERATIONAL CHECK WAS ACCOMPLSDR WXO2008F00008Battery Pack · failedDURING A ROUTINE OVERNIGHT SERVICE CHECK, INSP REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAIN REMOVED AND REPLACED THE APPROPRIATE BATTERIES IN THE POWER SUPPLY BATTERY PACK. A SATISFACTORY OPERATIONAL CHECK WAS ACCOMPLISHESDR WXO2008F00004Battery Pack · failedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION, MAINT REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINT REMOVED AND REPLACED THE APPROPRIATE BATTERIES IN THE POWER SUPPLY BATTERY PACK. A SATISFACTORY OPERATIONAL CHECK WSDR 070189Battery Pack · inoperativeDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION, MAINTENANCE DEPARTMENT PERSONNEL REPORTED THE RIGHT AND LEFT OVER WING EXIT LIGHT, FWD EMERGENCY EXIT DOOR (L1)AND THE LEFT FWD FLOOR EMERGENCY EXIT LIGHT INOP WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED SDR 070181Fuel Control · leakingFLIGHT 705 AT GSP (GREENVILLE,SC), FLIGHT CREW REPORTED DURING TAXI TO THE GATE UPON APU START THE SMELL OF FUEL AND SMOKE FILLED THE CABIN. ON CALL MTX INSPECTED THE AIRCRAFT AND APU AND DETERMINE THAT THE FUEL CONTROL WAS LEAKING FUEL INTO THE AIR DUCT. APSDR 070178Battery Pack · dischargedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE POWER SUPPLY BATTERY PACK. A SATISFSDR 070179Battery Pack · dischargedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE POWER SUPPLY BATTERY PACK. A SATISFSDR 070167Skin · puncturedON THE GROUND IN CHA, AIRCRAFT OUTER SKIN WAS PUNCTURED BY BELT LOADER. ACCOMPLISHED TEMPORARY REPAIR TO DAMAGED FUSELAGE BETWEEN STA 229 AND STA 275 IN ACCORDANCE WITH ERO 5330-002. AIRCRAFT FERRIED TO TUL FOR PERMENANT REPAIR. OPEN ITEMSDR WX0A070152Probe · obstructedDURING TAKEOFF ROLL, RIGHT AND LEFT ENGINES FAILED TO OBTAIN MINIMUM N1 SPEED AT 90 KNOTS. BOTH ENGINES INDICATED BETWEEN 79-80 N1 SPEED AT 1.86 EPR. ABORTED TAKEOFF AND RETURN TO THE GATE. MAINTENANCE DEPARTMENT PERSONNEL INSPECTED AND REMOVED DEBRIS FROM SDR 070144Battery · no testDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE POWER SUPPLY BATTERY PACK. A SATISFSDR 070141Battery Pack · inoperativeDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION, MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE POWER SUPPLY BATTERY PACK. A SATIS
Back to N892GA, cancelled Dec 15, 2018