N893GA, cancelled Mar 19, 2018
Service difficulty reports · 52
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N893GA' AND deregistration_id = 'N893GA-2018-03-19' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N893GA' AND deregistration_id = 'N893GA-2018-03-19' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR WX0A2015070272703Flap · crackedLEFT INBD FLAP TE CRACKED. REPLACED LT INBD FLAP TE IAW SRM 51-30-02.SDR WX0A2015062472687Light · inoperativeAFT GALLEY DOOR EMER EXIT INDICATOR LIGHT HAS ONE BULB WORKING. REPLACED BULB, OPERATIONS CHECKED GOOD IAW MM 25-60-00.SDR WX0A2015050872575Warning System · false activationAFTER TAKEOFF, NG UNSAFE, LIGHT CAME ON & OFF INTERMITTENTLY FOR 5 MINUTES. JACKED NG IAW AMM 7-12-00. INSPECTED GEAR POSITION SENSORS & WIRING. PERFORMED GEAR SWING OF NG IAW 32-30-00. COULD NOT DUPLICATE AT THIS TIME. NG UP SENSOR REPLACED, PRECAUTIONARSDR WX0A2015050172561Uplock Sensor · dirtyAFTER TAKEOFF WITH THE GEAR UP THE RED NOSE WHEEL LIGHT REMAINED ILLUMINATED. RAN QRH 32.9, LIGHT EXTINGUISHED. INSPECTED NOSE GEAR UPLOCK SENSOR & FOUND TO HAVE DIRTY GREASE AROUND SWITCH ROLLERS. CLEANED, CHECKED WIRING & SECURITY, NO ISSUES NOTED. OK FOSDR WX0A2015030472446Battery · dischargedEMERGENCY FLASHLIGHT IN COCKPIT INOPERATIVE. R & R BATTERY & OPERATIONS CHECKED GOOD IAW MM 25-60-00.SDR WX0A2014122272313Battery Pack · dischargedEMERGENCY LIGHTS AT L1 & R1 DOORS INOPERATIVE. R & R EMER LIGHT BATTERY PACK B5-205. OPERATIONS CHECKED GOOD IAW AMM 33-53-00.SDR WX0A2014081672095Screw · looseEMER LIGHTS IN THE TUNNEL, LOWER SIDEWALL LIGHTS INOPERATIVE. REPLACED BATTERIES, NO HELP. OPENED FIRST LIGHT AFT OF AIRSTAIR DOOR TO CHECK BULB. FOUND BOTH TERMINAL SCREWS BACKED-OFF. TIGHTENED SCREWS IAW AMM 20-50-04. OPERATIONS CHECKED GOOD IAW AMM 33-5SDR WX0A2014071872030Beam · corrodedAFT CARGO DOOR JAMB IS CORRODED. REMOVED DAMAGE BEAM & INSTALLED NEW BEAM IAW SRM 51-30-5. WORK ORDER 224279 M301 203 & 1010979 8000-0008.SDR WX0A2014071872029Cusp Web · corrodedPASSENGER CABIN LT CUSP WEB CORRODED AT FS 1135 - 1155 BETWEEN LBL 44 - 54. REMOVED DAMAGED AREA, FABRICATED REPAIR PARTS & INSTALLED IAW SRM 53-01 FIG 4 SHEET 4. WORK ORDER 224279 M301 621 & WORK ORDER 1010979 1000-0079.SDR WX0A2014071872028Cusp Web · corrodedLEFT CUSP WEB BETWEEN STATION 1309 - 1287 LBL44 - 54 CORRODED. R & R CUSP WEB IAW SRM 53-5 FIG 97. WORK ACCOMPLISHED ON WORK ORDER 224279 M301 ITEM 381 & WORK ORDER 1010979 2400-0176.SDR WX0A2014071872027Skin · corrodedRIGHT WING TE LOWER SKIN IS CORRODED AT STATION YCW = 150.000 & CTR WING XCW = 104.500 & XCW = 121.688 APPROX. PERMANENT REPAIR. REMOVED ORIGINAL DOUBLER & CORROSION. INSTALLED FILLER OF 0.125, 4 INCHES BY 2 INCHES & INSTALLED NEW MLG SUPPORT DOUBLER SR095SDR WX0A2014071872026Seat Track · corrodedCABIN SEAT TRACK CORRODED AT STATION 200 LBL 44. PERMANENT REPAIR. REPLACED DAMAGE SEAT TRACK SECTION FROM FS 200 TO 305 IAW SRM 53-05.SDR WX0A2014071672018Cusp Web · corrodedPASSENGER CABIN LT CUSP WEB CORRODED AT FS 693 - 712 LBL 54. REPAIRED CUSP WEB IAW SRM 53-05 FIG 131A-11 & SRM-51-30-2.SDR WX0A2014071172017Seat Track · corrodedPASSENGER CABIN SEAT TRACK IS DAMAGED STATION 218 AT RBL 12. REMOVED DAMAGED AREAS, FABRICATED REPAIR PLUGS & INSTALLED IAW SRM-53-05 FIG 4A.SDR WX0A2014071172016Fitting · corrodedPASSENGER CABIN GALLEY FITTING IS CORRODED STATION 218 AT RBL 12. R & R GALLEY FITTING IAW DWG 9936535.SDR WX0A072015Support · corrodedPASSENGER CABIN FWD GIRT BAR SUPPORT AT R1 DOOR ENTRY AREA EXFOLIATED. R & R SUPPORT IAW SRM 51-30-1.SDR WX0A2014070972013Cusp Web · corrodedLEFT CUSP WEB CORRODED AROUND LIGHTING HOLES BETWEEN FS 655 & 674 OTBD OF LBL 54. REPAIRED LT CUSP WEB BETWEEN FS 655 & 674 OTBD OF LBL 54 IAW SRM 53-05 PAR 144.SDR WX0A071919Battery · dischargedAFT TAIL COMPARTMENT EMERGENCY LIGHTS INOPERATIVE. R & R POWER SUPPLY BATTERIES. LIGHTS OPERATIONS CHECKED NORMAL IAW AMM 33-53-00.SDR WX0A071817Power Supply · inoperativeTWO EACH EXTERIOR EMERGENCY LIGHTS INOPERATIVE. R & R POWER SUPPLY, OPERATIONS CHECKED NORMAL IAW AMM 33-53-00.SDR WX0A071804Lock · dirtyL1 GIRT BAR DIFFICULT TO ARM & DISARM. CLEANED GIRT BAR LOCKS, ARM & DISARM GIRT BAR, OPERATIONS CHECKED GOOD IAW MM 25-62-00.SDR WX0A201310250034Battery Pack · inoperativeAFT F/A FLASHLIGHT DOES NOT FLASH. R & R FLASHLIGHT BATTERY IAW 25-60-00, OPS CHECKED GOOD.SDR WX0A201308130064Light · inoperativeDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION, MX REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYS WOULD NOT TEST. MX REPLACED THE EMERGENCY LIGHT ASSY AS REQUIRED. SATISFACTORY OPS CHECK ACCOMPLISHED IAW AMM 33-50-00. ACFT TO SERVICE.SDR WX0A071510Frame · gougedLIP UNDER LT AND RT LOWER SIDEWALL PANEL MOUNT SCREWS AT FRAME 522 HAVE SCREW GOUGES. REPLACED FUSELAGE FRAME AT STATION 522.SDR WX0A2013020471504Skin · gougedFUSELAGE SKIN BS 1485, GOUGED AT L3L. FABRICATED INTERNAL DOUBLER AND INSTALLED.SDR WX0A071503Pan · crackedAFT CARGO DOOR INNER AND OUTER PAN IS CRACKED. REMOVED DAMAGED AREA, FABRICATED REAIR PANS AND INSTALLED.SDR WX0A071500Skin · gougedFORWARD CARGO PIT DOOR OUTER LOWER SKIN EDGE GOUGED. REMOVED DAMAGED AREA. HFEL - NO DEFECTS NOTED. FABRICATED REPAIR PARTS AND INSTALLED.SDR WX0A071499Frame · gougedRIGHT STATION 1510 CANT FRAME GOUGED AT LONGERON 9L. REMOVED DAMAGED AREA, HFEL. HFEL - NO DEFECTS NOTED. FABRICATED REPAIR ANGLE AND INSTALLED.SDR WX0A071498Web · corrodedAFT CARGO PIT LOWER DOOR SURROUND WEB IS CORRODED BETWEEN STATION 1155 TO 1173. BLEND AREA, HFEL. NO DEFECTS NOTED. FABRICATED REPAIR DOUBLER AND INSTALLED.SDR WX0A201301291496Skin · corrodedFUSELAGE SKIN DOUBLER AT E & E BAY DOOR CUTOUT FS 134.299 BETWEEN LONGERON 28L AND 28R CORRODED. BLENDED THE DAMAGED AREA HFEL AREA. NO DEFECTS NOTED. FABRICATED REPAIR PARTS AND INSTALLED.SDR WX0A071490Vane · chafedLEFT WING O/B FLAP I/B VANE L/E CHAFED. REMOVED DAMAGED AREA, FABRICATED REPAIR PARTS AND INSTALLED.SDR WX0A071489Frame · damagedAFT CARGO COMPARTMENT FRAME STATION 1136 UPPER LIP DAMAGED AT LONGERON 29L. REMOVED DAMAGED AREA, FABRICATED REPAIR PARTS AND INSTALLED.SDR WX0A071361Battery · dischargedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE BATTERIES IN THE POWER SUPPLY BATTERSDR WX0A071360Battery · dischargedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE BATTERIES IN THE POWER SUPPLY BATTERSDR WX0A071359Battery · dischargedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE BATTERIES IN THE POWER SUPPLY BATTERYSDR WX0A071358Battery · dischargedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE BATTERIES IN THE POWER SUPPLY BATTERSDR WX0A071228Battery · dischargedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE BATTERIES IN THE POWER SUPPLY BATTERSDR WX0A071184Battery · dischargedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE BATTERIES IN THE POWER SUPPLY BATTERSDR WX0A071148Battery · dischargedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE BATTERIES IN THE POWER SUPPLY BATTERSDR WX0A071133Battery · dischargedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE BATTERIES IN THE POWER SUPPLY BATTERSDR WX0A2012031371124Battery Pack · dischargedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE BATTERIES IN THE POWER SUPPLY BATTERSDR WX0A071079Battery Pack · dischargedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE POWER SUPPLY BATTERY PACK AND MADE ASDR WX0A070901Skin · damagedLEFT ELEVATOR MUST SIDE WHERE TAB FAIRING IS INSTALLED HAS DOUBLE DRILLED HOLES. REPAIRED LOWER SKIN AND INBOARD END OH LEFT ELEVATOR IAW EA 14439 REV I/R DATED 07/05/2011.SDR WX0A070611Engine · malfunctionedFLIGHT CREW PERSONNEL REPORTED AND ABORTED START NR 2 ENGINE, DID NOT LIGHT OFF. STARTING NR 1, GROUND CREW ADVISED FLAMES OUT OF NR 2. MOTORED ENGINE, RAN FIRE CHECK LIST. MAINTENANCE DEPARTMENT PERSONNEL REMOVED AND REPLACED THE RIGHT ENGINE IAW TASK CARDSDR WX0A070699Water Separator · malfunctionedFLIGHT CREW REPORTED, BURNING SMELL FROM LEFT PACK AFTER TAKEOFF AND DURING CLIMB. NOTE: SMELL WENT AWAY AFTER LEFT PACK TURNED OFF. MAINTENANCE PERSONNEL REMOVED AND REPLACED WATER SEPARATOR IAW AMM 21-20-02. PERFORMED OPERATIONAL CHECK AT HIGH POWER ENGISDR WX0A070590Water Separator · malfunctionedFLIGHT PERSONNEL REPORTED BURNING SMELL FROM LEFT PACK AFTER TAKEOFF AND DURING CLIMB. NOTE; SMELL WENT AWAY WHEN LEFT PACK TURNED OFF. MAINTENANCE PERSONNEL REMOVED AND REPLACED WATER SEPARATOR ASSY IAW AMM 21-20-02. PERFORMED OPERATIONAL CHECK AT HIGH POWSDR WX0A070588Engine · failedFLIGHT PERSONNEL REPORTED ON TAKEOFF ROLL JUST AT 30 KNOTS, HARD SHUDDER ON RIGHT ENGINE. THE "ART" FIRED AND POWER LOSS RIGHT SIDE. UPON INSPECTION SEVERAL ENGINE PARTS BLEW AFT AND SOME PARTS VISIBLE IN AFT SECTION. SMALL, FIRE CONTAINED, BURNED ABOVE 600 SDR WX0A070507ASkin · corrodedFOUND CRACKED SKIN AND CORROSION AT APPROXIMATELY STA 569 AND LONG 30. CUT OUT DAMAGED SKIN SECTION, FABRICATED AND INSTALLED NEW SKIN SECTION AS PER SRM 53-04 DIM 60X38X.250. ADDRESSED AS REQUIRED.SDR WX0A070506Bulkhead · crackedSTA 37 FORWARD BULKHEAD FORWARD FACE HAS A SMALL CRACK BELOW LEFT UPPER GUIDE PIN. CUT OUT DAMAGED AREA AND SPLICED IN A NEW SECTION AS PER SRM 51-70-5. ADDRESSED AS REQUIRED.SDR WX0A070510Battery Pack · inoperativeDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE BATTERIES IN THE POWER SUPPLY BATTERSDR WX0A070510ABattery Pack · inoperativeDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE BATTERIES IN THE POWER SUPPLY BATTER
Back to N893GA, cancelled Mar 19, 2018