N894GA, cancelled Feb 18, 2014

Service difficulty reports · 24

Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.

Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy
  FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet'
  WHERE n_number = 'N894GA' AND deregistration_id = 'N894GA-2014-02-18'
  ORDER BY difficulty_date DESC"

Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.

SDR WX0A2013042271566Battery Pack · dischargedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE POWER SUPPLY BATTERY PACK AND MADE AApr 20, 2013 · N894GA · Doug DC982 · Emergency LightingSDR WX0A071480Battery · dischargedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE BATTERIES IN THE POWER SUPPLY BATTERJan 3, 2013 · N894GA · Doug DC982 · Emergency LightingSDR WX0A071454Battery · dischargedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE BATTERIES IN THE POWER SUPPLY BATTERDec 19, 2012 · N894GA · Doug DC982 · Emergency LightingSDR WX0A071193Battery · dischargedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE BATTERIES IN THE POWER SUPPLY BATTERApr 27, 2012 · N894GA · Doug DC982 · Emergency LightingSDR WX0A071054Power Supply · inoperativeDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE POWER SUPPLY BATTERY PACK AND MADE ADec 19, 2011 · N894GA · Doug DC982 · Emergency LightingSDR WX0A070955Battery · dischargedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE BATTERIES IN THE POWER SUPPLY BATTERSep 22, 2011 · N894GA · Doug DC982 · Emergency LightingSDR WX0A070898Battery · dischargedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE BATTERIES IN THE POWER SUPPLY BATTERJun 20, 2011 · N894GA · Doug DC982 · Emergency LightingSDR WX0A070559Light · inoperativeIT HAS BEEN REPORTED BY THE FLIGHT CREW THE EMERGENCY EVACUATION LIGHTING SYSTEM HAS BEEN FOUND TO BE DEFECTIVE. AISLE LIGHT WIRES HAVE BECOME EXPOSED, FLOOR PATH LIGHTING STRIP IS INOPERATIVE AND REPLACED ESCAPE PATH FLOOR LIGHTING STRIP. MAINTENANCE DEPARTApr 23, 2010 · N894GA · Doug DC982 · Emergency LightingSDR WX0A070544Battery Pack · dischargedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE LIGHT BATTERY PACK AND MADE ALL REQUMar 26, 2010 · N894GA · Doug DC982 · Emergency LightingSDR WX0A070339Battery Pack · inoperativeDURING A ROUTINE OVERNIGHT SERVICE CHECK INSP, MX REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYS WOULD NOT TEST. MX REMOVED AND REPLACED THE APPROPRIATE BATTERIES IN THE POWER SUPPLY BATTERY PACK. A SATISFACTORY OPS CHECK WAS ACCOMPLISHED IAW AMJun 27, 2009 · N894GA · Doug DC982 · Emergency LightingSDR WX0A070337Battery Pack · inoperativeDURING A ROUTINE OVERNIGHT SERVICE CHECK INSP REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYS WOULD NOT TEST. MX PERSONNEL REMOVED AND REPLACED THE APPROPRIATE BATTERIES IN THE PWR SUPPLY BATTERY PACK. A SATISFACTORY OPS CHECK WAS ACCOMPLISHED IAWJun 18, 2009 · N894GA · Doug DC982 · Emergency LightingSDR WX0A070311Shear Tie · crackedSHEAR TIE CRACKED AT BOTTOM END BETWEEN L13-L14, LEFT AT STATION 1380. REPAIRED PER ESO 80559 / AARD 53-10-20, REF E58 6278265.May 14, 2009 · N894GA · Doug DC982 · Fuselage Internal Mounting StructureSDR WX0A070309Seat Track · corrodedNR 6 SEAT TRACK CORRODED AT SPLICE AT STATION 798 REF E58 6278336. REPLACED SECTION OF NR 6 SEAT TRACK FROM STATION 798 TO STATION 909 PER SRM 53-05 FIG 4 SHEET 5 PAGE 36.May 14, 2009 · N894GA · Doug DC982 · Fuselage, Seat/Cargo Attach FittingsSDR WX0A070308Shear Tie · crackedSHEAR TIE CRACKED AT STATION 1401 BELOW APU EXHAUST DUCT.May 12, 2009 · N894GA · Doug DC982 · Fuselage Internal Mounting StructureSDR WX0A070288Battery Pack · inoperativeDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE POWER SUPPLY BATTERY PACK. A SATISFApr 16, 2009 · N894GA · Doug DC982 · Emergency LightingSDR WX0A070277Battery Pack · inoperativeDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE BATTERIES IN THE POWER SUPPLY BATTERFeb 26, 2009 · N894GA · Doug DC982 · Emergency LightingSDR WXO2008F00007Battery Pack · failedDURING A ROUTINE OVERNIGHT SERVICE CHECK, INSP REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINT REMOVED AND REPLACED THE APPROPRIATE POWER SUPPLY BATTERY PACK. A SATISFACTORY OPERATIONAL CHECK WAS ACCOMPLISHED IAW AMM 33-50Aug 21, 2008 · N894GA · Doug DC982 · Emergency LightingSDR WX0A070222Battery · failedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE BATTERIES IN THE POWER SUPPLY BATTERJul 23, 2008 · N894GA · Doug DC982 · Emergency LightingSDR 070173Longeron · corrodedFOUND LONGERON AT STA 1155 CORRODED. REMOVED AND REPLACED LONGERON P/N 5936037-501 AT STATION 1155 L-29R IAW SRM 51-30-05 AND 51-30-02.Oct 24, 2007 · N894GA · Doug DC982 · Fuselage Main, Longeron/StringerSDR 070174Frame · corrodedFRAME AT STA 1155 CORRODED. REMOVED AND REPLACED FRAME P/N 5AA9936073-9 AT STATION 1155 L27R AND 28R IAW SRM 51-30-05 AND 51-30-02.Oct 24, 2007 · N894GA · Doug DC982 · Fuselage Main, FrameSDR 070166Shear Tie · damagedAFT CARGO COMPARTMENT SHEAR TIE HAS CORROSION AT STATION 1150 BETWEEN L29R AND L30R. FABRICATED FORMER FROM 7075-T6 .063 AND REPAIR SPLICE FROM 7075-T6 .063 PER SRM 53-03 FIGURE 3.Sep 26, 2007 · N894GA · Doug DC982 · Fuselage Internal Mounting StructureSDR 070165Structure · crackedHORIZONTAL STABILIZER LEFT SIDE CRACKED AT REAR UPPER INBOARD SIDE BETWEEN UPPER AND LOWER BOLTS AT STATION XH8.50. HORIZONTAL STABILIZER SENT TO VENDOR FOR REPAIR. REPAIRED IAW ESO 80559 AND BOEING DRAWING 5R09550027. HORIZONTAL STABILIZER OK FOR CONTINUEDAug 29, 2007 · N894GA · Doug DC982 · Horizontal Stabilizer StructureSDR 070164Skin · gougedAFT CARGO DOOR HAS A GOUGE BELOW DOOR HANDLE. ORIGINAL SKIN THICKNESS .050". REMOVED .011", OUT OF LIMITS PER SRM 53-04 FIG 38. AREA MEASURES 2.7" BY 1.7" BY .011". FABRICATED INTERNAL REPAIR DOUBLER 2024 T3, .032". CARGO DOOR OK FOR CONTINUED SERVICE.Aug 28, 2007 · N894GA · Doug DC982 · Cargo/Baggage DoorsSDR 070163Skin · gougedAFT CARGO PIT DOOR HAS GOUGE ON 3RD STRINGER FROM BOTTOM OF DOOR. ORIGINAL SKIN THICKNESS .050". REMOVED .015" OUT OF LIMITS PER SRM 53-04 FIG 38. AREA MEASURES 2" BY 1" BY .015. FABRICATED INTERNAL REPAIR DOUBLER 2024 T3 .032". DOOR SKIN OK FOR CONTINUEDAug 20, 2007 · N894GA · Doug DC982 · Cargo/Baggage Doors
Back to N894GA, cancelled Feb 18, 2014