N912FR, cancelled Feb 5, 2016
Service difficulty reports · 62
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N912FR' AND deregistration_id = 'N912FR-2016-02-05' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N912FR' AND deregistration_id = 'N912FR-2016-02-05' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR F3LA2015031101118Battery Pack · failedEPSU EMER LIGHT BATTERY 12WL, MIDDLE RT FAILED CAPACITY TEST ON A6 CHECK. R & R EPSU BATTERY 12WL IAW AMM 33-51-38-000-002A & 33-51-38-400-002A. OPERATIONS CHECKED GOOD. OK FOR SERVICE.SDR F3LA2014100101073Battery · dischargedAFT EPSU BATTERY FAILED A CHECK TASK CARD FFT-335100-03-1, CAPACITY CHECK. R & R BATTERY ASSEMBLY IAW AMM 33-51-39-000-005A & AMM 33-51-39-400-005-A.SDR F3LA2014013001004Skin · saturatedAIRCRAFT OUT OF SERVICE DUE TO C8 52 CHECK. RT ELEVATOR SN CC2574 THERMO GRAPHIC INSPECTION REVEALED INDICATIONS ON UPPER PANEL IRREGULAR IN SHAPE & BLACK IN COLOR. REPAIRED RT ELEVATOR UPPER PANEL AT 13 EACH AREAS OF LIQUID INGRESS IAW A319 SRM 55-20-00, PBSDR F3LA2014013001003Shear Plate · crackedAIRCRAFT OUT OF SERVICE DUE TO C8 S2 CHECK. MAIN CABIN RT SIDE SHEAR PLATE FR 69 TO FR 70 IS CRACKED. REMOVED RT SHEAR PLATE FROM FR 69 - FR 70, REPLACED WITH NEW SHEAR PLATE IAW AIRBUS A319 SRM 51-42-11 PG 6 & 7.SDR F3LA2014013001002Floorbeam · corrodedAIRCRAFT OUT OF SERVICE DUE TO C8 S2 CHECK. MAIN CABIN AFT FLOOR SUPPORT BEAM AFT OF SEAT TRACK BEAM Y 1732 HAS CORROSION AT FR 68. REMOVED CORROSION ON AFT CABIN FLOOR SUPPORT BEAM IAW SRM 51-74-00 & FOUND TO BE OUT OF LIMITS IAW SRM 53-00-14 PB 101 FIG 102SDR F3LA2014013001001Floorbeam · corrodedAIRCRAFT OUT OF SERVICE DUE TO C8 S2 CHECK. MAIN CABIN FLOOR BEAM Y 1292 HAS CORROSION AT FR 16. R & R MAIN CABIN FLOOR BEAM LAW A319 SRM 51-72-11 PARA 5 & 6.SDR F3LA2014013001000Floorbeam · corrodedAIRCRAFT OUT OF SERVICE FOR C8 S2 CHECK. AFT CABIN FLOOR SUPPORT BEAM INBD OF SEAT TRACK BEAM Y 765 6 INCHES FWD OF FR 66 HAS CORROSION. R & R FLOOR BEAM AT AFT CABIN INBD OF SEAT TRACK Y 765 6 INCHES FWD OF FR 66 IAW A319 SRM 51-42-11.SDR F3LA2014013000959Shear Plate · corrodedAIRCRAFT OUT OF SERVICE DUE TO C8 S2 CHECK. AFT CABIN LT LATERAL SHEAR PLATE CRACKED AT FRAME 69. R & R LT LATERAL SHEAR PLATE WITH NEW PART IAW SRM 51-42-11, PAR 6, 7 & 13.SDR F3LA2014013000958Floorbeam · corrodedAIRCRAFT OUT OF SERVICE FOR C8 S2 CHECK. MAIN CABIN FLOOR BEAM Y 254 HAS CORROSION AT FR 18. REMOVED CORROSION AT MAIN CABIN FLOOR BEAM Y 254, FR L8 IAW SRM 51-74-00, 6 B ORIGINAL THICKNESS .079 INCHES, REMOVED .022 INCHES FOUND TO BE WITHIN LIMITS IAW SRM 5SDR F3LA2014013000957Floorbeam · corrodedAIRCRAFT OUT OF SERVICE DUE TO C8 S2 CHECK. FLOOR SUPPORT BEAM AFT OF SEAT TRACK Y 1292 HAS CORROSION AT FR 68. REMOVED FLOOR SUPPORT BEAM Y 1292 AT FR 68. REPLACED WITH NEW FLOOR SUPPORT BEAM PN D5347218920400 IAW A319 SRM 51-42-11 PG 7.SDR F3LA2012083100782Actuator · intermittentACFT LEFT C-CHECK AFTER COMPLETE SET LANDING GEAR TIME, DEPARTED. NLG DID NOT LOCK UP, GEAR DOORS DID NOT CLOSE. ACFT WAS PREPPED FOR GEAR DOWN FERRY FLIGHT. FERRY FLIGHT DID NOT OCCUR. DISCREPANCY WAS WORKED AT AIRPORT, ADJUSTMENTS MADE, REF NR 43936. OCF USDR F3LA2011022200609Support · corrodedC-CHECK: NON ROUTINE 2994; LATERAL SHEAR PLATE, FRAME 69 - 70 RIGHT, HAS OUT OF LIMITS CORROSION AT FASTENER HOLES. REMOVED AND REPLACED SHEAR PLATE IAW AO-53EO-31434.SDR F3LA2011022200608Support · corrodedC-CHECK: NON ROUTINE # 29844; LATERAL SHEAR PLATE, FRAME 69 - 70 LEFT, HAS OUT OF LIMITS CORROSION AT FASTENER HOLES. REMOVED AND REPLACED SHEAR PLATE IAW AO-53EO-31434.SDR F3LA2011022200610Frame · corrodedC-CHECK: NON ROUTINE 29941; FRAME 69 -Y765 HAS OUT OF LIMITS CORRORION AT FASTER HOLES, PER SRM 53-00-14 FIG 102. REMOVED AND REPLACE BEAM IAW A319 SRM 51-42-1.SDR F3LA2010033000377Thermostat · inoperativeCAPTAIN REPORTED BLEED 2 FAULT AND LOSS OF CABIN PRESSURISATION. MAXIMUM CABIN ALTITUDE 10,500. FLIGHT NR 963 DIVERTED FOR AN UNSCHEDULED LANDING. MX TROUBLESHOOT NR 2 ENGINE BLEED AIR SYS IAW AMM 36-11-00-720-005 AND R & R THE NR 2 ENGINE FAN AIR VALVE THERMSDR F3LA2009121600258Epsu · malfunctionedTHE FLIGHT CREW NOTED THAT THE EMERGENCY EXIT LIGHTS AND ESCAPE PATH LIGHTS IN CABIN ARE CONTINUOUSLY ON WITH THE EMERGENCY EXIT LIGHT SWITCH IN THE ARM POSITION. MX PERFORMED AN OPS TEST OF THE EMERGENCY LIGHTING SYS AND THE OPS CHECK WAS GOOD IAW AMM 33-51-SDR F3LA2009040100070Window · crackedAT FL 390, PILOT REPORTED THE RIGHT SLIDING WINDOW CRACKED IN BOTH PANES. MAINTENANCE REMOVED AND REPLACED THE RIGHT SLIDING WINDOW AND PERFORMED LEAK CHECK IAW AMM 56-12-11 PB 401.SDR F3LA200800010Cabin Pressure · fluctuatesTHE FLIGHT CREW REPORTED, DURING CLIMB-OUT, PRESSURIZATION FLUCTUATED 200 FEET PER MINUTE BETWEEN FLIGHT LEVEL 350 UP TO AND LEVELING AT FLIGHT LEVEL 380. AT THE SAME TIME, THE R2 DOOR PRESSURE LIGHT FLASHED AND THE SLIDE "DISARM" ILLUMINATED, ON THE LOWER ECSDR F3LA200700404Floor Panel · corrodedDURING C4/S1 CHECK, INSPECTION REPORTED FLOOR PANEL 262FF CORRODED ON LOWER SURFACE. REMOVED AND REPLACED FLOOR PANEL 262FF IAW EO A0-53T-11996.SDR F3LA200700393Fastener · corrodedDURING C4/S1 CHECK, INSPECTION REPORTED CORRODED FASTENERS THAT SECURE LIGHT TO RT WING-TO-BODY FAIRING 192DT. REMOVED AND REPLACED RT UPPER WING LIGHT COVER MOUNTING SCREWS ON PANEL NR 192DT.SDR F3LA200700392Fastener · corrodedDURING C4/S1 CHECK, INSPECTION REPORTED RT WING-TO-BODY FAIRING 192DT HAD CORRODED FASTENERS AT LOWER SEAL. REMOVED AND REPLACED RT WING UPPER WING-TOO-BODY FAIRING PANEL NR 192DT LOWER SEAL MOUNTING SCREWS IAW 51-42-11.SDR F3LA200700403Plate · damagedDURING C4/S1 CHECK, INSPECTION REPORTED AFT CARGO COMPARTMENT AFT BULKHEAD CROSSOVER BEAM HAD FASTENERS PULLING THROUGH THE CENTER PLATE. REMOVED AND REPLACED AFT CARGO COMPARTMENT AFT BULKHEAD CROSSOVER BEAM CENTER PLATE IAW SRM 51-42-11.SDR F3LA200700391Plate · corrodedDURING C4/S1 CHECK, INSPECTION REPORTED L2 DOOR FWD GIRT BAR LATCH FLOOR FILLER HAD A SMALL SPOT OF CORROSION. REMOVED AND REPLACED L2 DOOR FWD GIRT BAR LATCH FILLER PANEL IAW AMM 53-42-12-PB401.SDR F3LA200700390Plate · corrodedDURING C4/S1 CHECK, INSPECTION REPORTED R2 DOOR AFT GIRT BAR LATCH FILLER CORRODED. REMOVED AND REPLACED R2 DOOR AFT GIRT BAR LATCH FILLER PANEL IAW AMM 53-42-12-PB401.SDR F3LA200700389Plate · corrodedDURING C4/S1 CHECK, INSPECTION REPORTED L2 DOOR AFT GIRT BAR LATCH FILLER CORRODED. REMOVED AND REPLACED L2 DOOR AFT GIRT BAR LATCH FILLER IAW AMM 53-42-12-PB401.SDR F3LA200700402Blanking Plate · corrodedDURING C4/S1 CHECK, INSPECTION REPORTED F1 DOOR AFT GIRT BAR STOP LEVER FITTING BLANKING PLATE CORRODED ON BOTTOM SIDE. REMOVED AND REPLACED R1 DOOR AFT GIRT BAR STOP LEVER FITTING BLANKING PLATE IAW AMM 53-12-12-PB401.SDR F3LA200700397Floorbeam · corrodedDURING C4/S1 CHECK, INSPECTION REPORTED FLOORBEAM AT FR16, STA Y254, CORRODED ON THE TOP CAP. DETERMINED CORROSION TO BE OUT OF LIMITS IAW SRM 53-11-14. REMOVED AND REPLACED FLOORBEAM FROM FR12 THRU FR24, STA 254, IAW SRM 52-42-11 AND 51-72-11.SDR F3LA200700388Floor Panel · corrodedDURING C4/S1 CHECK, INSPECTION REPORTED FLOOR PANEL 221FF (L1 DOOR) CORRODED ON BOTTOM SIDE. REMOVED AND REPLACED FLOOR PANEL 221FF IAW AMM 53-12-12-PB401.SDR F3LA200700387Floor Panel · corrodedDURING C4/S1 CHECK, INSPECTION REPORTED FLOOR PANEL 222FF (R1 DOOR) CORRODED ON BOTTOM SIDE. REMOVED AND REPLACED FLOOR PANEL 222FF IAW AMM 53-12-12-PB401.SDR F3LA200700386Dummy Rail · corrodedDURING C4/S1 CHECK, INSPECTION REPORTED DUMMY RAIL AT Y503.2, FR 12 TO FR 16, CORRODED ON TOP. CORROSION FOUND TO BE OUT OF LIMITS IAW SRM 53-11-14. REMOVED AND REPLACED DUMMY RAIL IAW SRM 51-42-11 AND 51-44-11.SDR F3LA200700384Floorbeam · corrodedDURING C4/S1 CHECK, INSPECTION REPORTED CORROSION ON FLOORBEAM AT Y1292 AND FR16, AT ATTACH POINT. REMOVED AND REPLACED FLOORBEAM AT Y1292 IAW SRM 51-42-11.SDR F3LA200700401Support Beam · bentDURING C4/S1 CHECK, INSPECTION REPORTED AFT CARGO FWD BULKHEAD PANEL SUPPORT BEAM AT APPROX STR 42L, FR47 TO FR51, BENT. REMOVED, FABRICATED AND INSTALLED REPLACEMENT SUPPORT BEAM IAW SRM 51-42-11, SRM 51-44-11, 51-75-12 AND DRAWING D53974679.SDR F3LA200700400Lock Fastener · corrodedDURING C4/S1 CHECK, INSPECTION REPORTED L2 DOOR SILL AFT GIRT BAR FITTING CORRODED AT LOCK FASTENER. REMOVED AND REPLACED FASTENER IAW SRM 51-42-11.SDR F3LA200700399Shear Plate · corrodedDURING C4/S1 CHECK, INSPECTION REPORTED SHEAR PLATE AT Y1292, BETWEEN FR69 AND FR70, CORRODED. REMOVED AND REPLACED SHEAR PLATE AND FLOORBEAM IAW SRM 51-42-11 AND EA A9-53R-12329.SDR F3LA200700398Floorbeam · corrodedDURING C4/S1 CHECK, INSPECTION REPORTED FLOORBEAM AT Y765, FR68, CORRODED. DETERMINED CORROSION TO BE OUT OF LIMITS IAW 53-00-14. REMOVED AND REPLACED FLOOR BEAM AT Y768 IAW SRM 51-42-11.SDR F3LA200700396Floorbeam · corrodedDURING C4/S1 CHECK, INSPECTION REPORTED FLOORBEAM AT Y1292, FR68, CORRODED. DETERMINED CORROSION TO BE OUT OF LIMITS IAW SRM 53-00-14, PAR 4 B. REMOVED AND REPLACED FLOORBEAM Y1292 AT FR 68-69 IAW SRM 51-42-11 AND 51-44-11.SDR F3LA200700395Sill · corrodedDURING C4/S1 CHECK, INSPECTION REPORTED L2 DOOR SILL CORRODED AT VARIOUS LOCATIONS BETWEEN FR 66 AND FR 68. REMOVED AND REPLACED L2 DOOR SILL PLATE IAW SRM 51-42-11, 51-44-11, DRAWING D53480505 AND EA A9-53R-12330.SDR F3LA200700394Floorbeam · corrodedDURING C4/S1 CHECK, INSPECTION REPORTED FLOORBEAM AT Y1292, FR66, CORRODED AT NUTPLATE HOLES. REMOVED AND REPLACED FLOORBEAM AT Y1292, FR66, IAW SRM 51-42-11.SDR F3LA200700383Attach Bolt · corrodedDURING C4/S1 CHECK, INSPECTION REPORTED LWR ATTACHMENT BOLT ON INBD AFT CORNER OF LAV "A" SEVERELY CORRODED. REMOVED AND REPLACED BOLT IAW AMM 25-41-41-PB401.SDR F3LA200700381Shear Plate · corrodedDURING C4/S1 CHECK, INSPECTION REPORTED SHEAR PLATE AT BS -Y1292 BETWEEN FR 69 AND FR 70 CORRODED. CORROSION FOUND TO BE OUT OF LIMITS IAW SRM 53-41-14-101. REMOVED AND INSTALLED REPLACEMENT SHEAR PLATE IAW SRM 51-42-11, SRM 51-44-11 AND EA A9-53R-12329.SDR F3LA200700380Floorbeam · corrodedDURING C4/S1 CHECK, INSPECTION REPORTED FLOORBEAM AT BS -Y1292 HAD CORROSION AT NUT PLATE HOLES BETWEEN FR 68 AND FR 69. FOUND CORROSION TO BE OUT OF LIMITS IAW SRM 53-00-14, FIG. 102. REMOVED AND REPLACED FLOORBEAM IAW SRM 51-42-11.SDR F3LA200700378Rivet · shearedDURING C4/S1 CHECK, INSPECTION REPORTED SHEARED RIVETS ON WEB AT STA. -Y1292 BETWEEN FR68 AND FR69. REMOVED AND REPLACED RIVETS IAW A319 SRM 51-44-11, 51-46-11 AND EA A9-53R-12329.SDR F3LA200700405Mount Bolt · corrodedDURING C4/S1 CHECK, INSPECTION REPORTED LAV E LOWER FLOOR MOUNT BOLTS CORRODED. REMOVED AND REPLACED CORRODED FLOOR MOUNT BOLTS IN LAV E IAW AMM 25-43-42-PB401.SDR F3LA200700382Bolt · corrodedDURING C4/S1 CHECK, INSPECTION REPORTED LAV "D" MOUNT BOLTS CORRODED. REMOVED AND REPLACED CORRODED MOUNT BOLTS IAW AMM 25-43-41-PB401.SDR F3LA200700410Battery Pack · no testDURING C4/S1 CHECK, INSPECTION REPORTED AFT EMERGENCY LIGHT BATTERY FAILED CAPACITY CHECK. REMOVED AND INSTALLED SERVICEABLE AFT EMERGENCY LIGHT BATTERY PACK IAW AMM 33-51-38-000-002. PERFORMED BITE TEST OF AFT EMERGENCY LIGHT EPSU/BATTERY PACK IAW AMM 33-51SDR F3LA200700409Battery Pack · failedDURING C4/S1 CHECK, INSPECTION REPORTED LT OVERWING EMERGENCY LIGHT BATTERY FAILED CAPACITY CHECK. REMOVED AND INSTALLED SERVICEABLE BATTERY IN LT OVERWING EPSU IAW AMM 33-51-38-420-052. PERFORMED BITE TEST IAW AMM 33-51-38-400-002 AND TESTED GOOD.SDR F3LA200700408Battery Pack · failedDURING C4/S1 CHECK, INSPECTION REPORTED RT OVERWING EMERGENCY LIGHT BATTERY FAILED CAPACITY CHECK. REMOVED AND INSTALLED SERVICEABLE BATTERY PACK IN RT OVERWING EPSU IAW AMM 33-51-38-400-002. PERFORMED BITE TEST OF RT OVERWING EMERGENCY LIGHT EPSU/BATTERY PASDR F3LA200700407Battery Pack · failedDURING C4/S1 CHECK, INSPECTION REPORTED FWD EMERGENCY LIGHT BATTERY FAILED CAPACITY CHECK. REMOVED AND INSTALLED SERVICEABLE BATTERY IN FWD EPSU (10WL) IAW AMM 33-51-38-400-002. PERFORMED A BITE TEST OF THE FWD EMERGENCY LIGHT EPSU/BATTERY PACK IAW AMM 33-51SDR F3LA200700406Release Cable · inoperativeDURING C4/S1 CHECK, INSPECTION REPORTED RT OVERWING EXIT SLIDE RELEASE CABLE WOULD NOT RETRACT. REMOVED AND REPLACED RT OVERWING SLIDE RELEASE CABLE IAW AMM 25-62-43-PB401.SDR F3LA200700377Release Cable · inoperativeDURING C4/S1 CHECK, INSPECTION REPORTED LT OVERWING EMERGENCY EXIT SLIDE RELEASE CABLE WOULD NOT RETRACT. REMOVED AND REPLACED LT OVERWING EXIT SLIDE RELEASE CABLE IAW AMM 25-62-43-000-001. COMPLETED ADJUSTMENT AND OPERATIONAL CHECK OF SLIDE RELEASE CABLE IA
Back to N912FR, cancelled Feb 5, 2016