N919NK, cancelled Oct 16, 2026
Service difficulty reports · 29
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N919NK' AND deregistration_id = 'N919NK-2026-10-16' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N919NK' AND deregistration_id = 'N919NK-2026-10-16' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR GTIA2025050138894Filter · odorFUME EVENT FWD CABIN DURING DESCENT. MUSTY/DIRTY SOCKS SMELL. REF AIR QUALITY REPORTING FORM. DESCRIPTION OF ODOR/FUMES: CONTINUOUS AND DISCOMFORTABLE, DIRTY SCOKS SMELL. APPARENT CABIN SOURCE: CABIN AIR SUPPLY VENTS. FWD AND MID CABIN. NO VISIBLE SMOKE/HAZE. SDR GTIA2025042138867Unknown · odorDURING LANDING IN MCO A CHANGE IN ORDOR WAS PRESENT IN THE FLIGHT DECK AND CABIN FOR 5-10 SEC PERIOD. NOT FUME BUTA STRONG ORDOR CHANGE. DESCRIPTION OF ODOR/FUMES: TEMPORARY, UNKNOWN ODOR. APPARENT CABIN SOURCE: CABIN AIR SUPPLY VENTS. AFT CABIN, FWD CABIN, ASDR GTIA2024093038401Unknown · fumesFUME EVENT ON DESCENT-PERFORMED TSM 05-50-00-810-831-A. NO FUMES NOTED AT THIS TIME. AC OK FOR CONT SVC. MOC 119255SDR GTIA2024052138131Unknown · odorWET DIRTY SOCK SMELL IN CABIN DURING CLIMB, CRUISE AND DESCENT. -PERFORMED TSM 05-50-00-810-831-A. APU OPERATED WITH PACKS NO SMELL. RAN ENG 1 & 2 SEPARATELY NO SMELL. NO SMELL UPON ARRIVAL OF A/C. A/C OK FOR CONTINUE SERVICE.SDR GTIA2024030237961Bottle · low pressurePASSENGER / CREW DOOR R #2 DOOR ASSIST BOTTLE NEEDS SERVICING-SERVICED PASSENGER / CREW DOOR R # 2 IAW AMM 52-10-00-614-001-ASDR GTIA2024020237822Bottle · low pressureR1 AND R2 PASSENGER DOOR ASSIST BOTTLES NEED SERVICING-SERVICED R1 AND R2 PASSENGER DOOR IAW AMM 52-10-00SDR GTIA2023112137637Unknown · unknownBEFORE THE DESCENT FLIGHT ATTENDANT REPORT ODOR LIKE BURNING EYES BETWEEN ROWS 20-23 LEFT SIDE.WE FOLLOW THE PROCEDURE OF ODOR/FUMES IN THE CABIN AND WITH PACK 1 OFF IT WAS CONTAINED-PERFORMED INSPECTION OF PACK #2 AC SYSTEM IAW TSM 49-00-00. OPERATED PACKS FSDR GTIA2023070637310Unknown · unknownL2 AND R2 DOOR ASSIST BTLS REQUIRES SERVICING-SERVICED L2 AND R2 DOOR ASSIST BTLS PER AMM 52-10-00 TO PROPER LEVELSDR GTIA2023052237201Bottle · low pressureR2 DOOR ASSIST BOTTLE REQIURES SERVICING -SERVICED R2 DOOR ASSIST BOTTLE IAW AMM 52-10-00SDR GTIA2022110736761Bottle · dischargedR1 DOOR ASSIST BOTTLE LOW PRESSURE.-SERVICED DOOR ASSIST BOTTLE I.A.W AMM 52-10-00-614-001-A.SDR GTIA2022101336718Flashlight · inoperativeREF LOGPAGE 2799859-1 L2 P/A FLASHLIGHT BLINKING RED -R&R FLASHLIGHT ASSBLY IAW CMM 25-60-02. THIS CLOSES DMI 2799859-1. MOC NOTIFIED. PLACARD REMOVEDSDR GTIA2022100336692Epsu · no testEPSU BATTERY (13WL) FAILED ON TEST SDR REQD. REF. NR # 5001184122-0010.-VERIFIED NR # 5001184122-0010, EPSU BATTERY (13WL) WAS REPLACED AS PER AMM 33-51-38 REV. 74. TEST OK. SDR CREATED.SDR GTIA2022100336691Epsu · no testEPSU BATTERY (10WL) FAILED TEST. REF. NR # 5001184122-0010. SDR REQUIRED-VERIFIED NR # 5001184122-0010, EPSU BATTERY (10WL) WAS REPLACED AS PER AMM 33-51-38 REV. 74, TEST OK. SDR CREATED.SDR GTIA2022100336690Epsu · no testEPSU BATTERY (11WL) FAILED ON TEST. REF. NR # 5001184122-0010, SDR REQUIRED-VERIFIED NR # 5001184122-0010, EPSU BATTERY (11WL) WAS REPLACED AS PER AMM 33-51-38 REV. 74, TEST OK. SDR CREATED.SDR GTIA2022100336689Epsu · no testEPSU BATTERY (12WL) FAILED ON TEST. REF. NR# 5001184122-0010. SDR REQUIRED.-VERIFIED NR # 5001184122-0010, EPSU BATTERY (12WL) WAS REPLACED AS PER AMM 33-51-38 REV. 74, TEST OK. SDR CREATED.SDR GTIA2022070136502None · noneL1 DOOR ASSIST BOTTLE REQUIRES SERVICING-SERVICED L-1 DOOR ASSIST BOTTLE TO PROPER LEVEL IAW AMM 52-22-00SDR GTIA2022051236420None · noneR1 DOOR ASSIST BOTTLE PRESSURE LOW.-SERVICED THE R1 DOOR ASSIST BOTTLE TO PROPER PRESSURE IAW AMM 52-10-00SDR GTIA2021121336169None · noneR1 DOOR ASSIST BOTTLE LOW PRESSURE. -SERVICED THE R1 DOOR ASSIST BOTTLE TO PROPER PRESS. IAW AMM 52-10-00SDR GTIA2021072935894Bottle · low pressureR1 DOOR ASSIST BOTTLE BELOW WEEKLY LIMIT-AVC R1 DOOR ASSIST BOTTLE TO PROPER PSI AS PER AMM 52-10-00.SDR GTIA2021070135837Bottle · low pressureR2 DOOR ASSIST BOTTLE REQUIRES SERVICING -SERVICED R2 DOOR ASSIST BOTTLE IAW AMM 52-10-00SDR GTIA2021061035793Bottle · low pressureR1 DOOR ASSIST BOTTLE REQUIRES SERVICING-SERVICED R1 DOOR ASSIST BOTTLE IAW AMM 52-10-00. LEAK CHECK GOOD.SDR GTIA2021040135662Megaphone · inoperativeFWD MEGAPHONE INOP-R/R MEGAPHONE IAW SPIRIT EMER EQUIP DRAWING. OPS CHECK GOODSDR GTIA2021012535567Bottle · low pressureR1 DOOR ASSIST BOTTLE LOW. SERVICE R1 DOOR ASSIST BOTTLE, IAW AMM 52-10-00.SDR GTIA2020113035480Bottle · low pressureR1 DOOR ASSIST ACCUMULATOR LOW. SERVICED R1 DOOR ASSIST ACCUMULATOR TO PROPER PRESSURE, IAW AMM 52-10-00.SDR GTIA2020101235390Bottle · low pressureR1 DOOR ASSIST BOTTLE REQUIRES SERVICING. SERVICED R1 DOOR ASSIST BOTTLE, IAW AMM 52-10-00.SDR GTIA2020090735348Bottle · low pressureR1 DOOR BOTTLE ASSISTANCE REQUIRE SERVICE. SERVICE R1 DOOR BOTTLE ASSISTANCE TO PROPEL LEVEL IAW AMM 52-10-00.SDR GTIA2020061535202Bottle · low pressureR1 DOOR DAMPER ASSIST BOTTLE REQUIRES SERVICE. SERVICED R1 ASSIST BOTTLE IAW AMM 52-10-00.SDR GTIA2020030935078Assist System · low pressureDURING WEEKLY R1 DOOR ASSIST REQUIRES SERVICE-SVCD R1 DOOR ASSIST IAW AMM 52-10-00SDR GTIA202002034988Bottle · low pressureR1 DOOR ASSIST REQUIRES SVC-SERVICED RI DOOR ASSIST BOTTLE IAW AMM 52-10-00