N922UP, cancelled Jan 8, 2008
Service difficulty reports · 173
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N922UP' AND deregistration_id = 'N922UP-2008-01-08' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N922UP' AND deregistration_id = 'N922UP-2008-01-08' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR UPS96220191Hinge · corrodedINSPECTION TYPE-C, R/W I/B AILERON CENTER AND O/B TAB HINGE FITTINGS ARE CORRODED AILERON SIDE. REMOVED AND REPLACED CENTER AND O/B TAB FITTINGS ON R/W, I/B AILERON IAW SRM 51-30-02.SDR UPS96220190Skin · corrodedINSPECTION TYPE-C, CORROSION ON SKIN AT STA 1180 STR 7 LT WL 260. CORROSION FOUND TO BE OUT OF LIMITS IAW SRM 53-30-1. REPAIRED SKIN AT STA 1180 STR 7 LT WL 260 IAW SRM 53-30-1.SDR UPS96220189Stiffener · corrodedINSPECTION TYPE-C, CORROSION ON TOP DOGHOUSE BEAM AT BS 336 LBL 15. REMOVED CORROSION, REWORKED OUT OF LIMITS IAW SRM 53-10-1, REMOVED AND REPLACED STIFFENER, BEAM IAW SRM 51-30-2.SDR UPS205112Eel Assy · inoperativeWHILE ON GROUND, MAINTENANCE FOUND FLIGHT DECK EMERGENCY EXIT LIGHT INOP. REMOVED AND REPLACED THE LIGHT ASSEMBLY. OPS CHECK GOOD.SDR UPS204454Eel · malfunctionPILOT REPORTED, EMERGENCY EXIT LIGHTS ILLUMINATED ON TAXI OUT WITH ARMING SWITCH ARMED. LIGHT WENT OUT WHEN SWITCH PLACED IN OFF POSITION, THEN ON WHEN ARMED. RESECURED EMERGENCY EXIT LIGHT ASSY, CHECK OK.SDR UPS203099Rib · crackedWHILE IN C-CHECK, MAINTENANCE FOUND A CRACK IN THE RIB UPPER CHORD AT BL 70.5 AND STATION 760.95. MAINTENANCE CUT OUT DAMAGE AND REPAIRED IAW SRM 51-10-6 AND UPS EO 727-5710-1271F AND UPS EO 727-5710-6865A.SDR UPS203098Channel · corrodedWHILE IN C-CHECK, MAINTENANCE FOUND CORROSION ON THE FORWARD SIDE AND BASE OF THE FLOOR SUPPORT IN THE LAV AREA AT STATION 342 FROM RBL 13 TO 20. MAINTENANCE FABRICATED AND REPLACED THE SUPPORT CHANNEL IAW SRM 51-30-2 AND 51-10-1.SDR UPS203097Spar · crackedWHILE IN C-CHECK, MAINTENANCE FOUND A CRACK IN THE VERTICAL STABILIZER RIGHT HAND REAR SPAR CHORD AT STATION 0 TO 12. MAINTENANCE REPAIRED THE ONE INCH CRACK STOP AT FASTENER HOLE.SDR UPS203096Spar · crackedWHILE IN C-CHECK, MAINTENANCE FOUND A CRACK IN THE VERTICAL STABILIZER REAR SPAR LEFT HAND CHORD AT STATION 0 TO 12. MAINTENANCE STOP DRILLED AND INSTALLED THE REPAIR KIT.SDR UPS203095Angle · crackedWHILE IN C-CHECK, MAINTENANCE FOUND A CRACK IN THE RIGHT HAND SKIN SUPPORT ANGLE AT FS 1345 AND FIN STATION 22.5. MAINTENANCE CUT OUT THE DAMAGED AREA AND INSTALLED FABRICATED SECTION AND SPLICE IAW SRM 51-40-3 AND 51-30-2.SDR UPS203094Rib · crackedWHILE IN C-CHECK, MAINTENANCE FOUND A CRACK IN THE RIGHT HAND RIB FLANGE AT STATION 1365 AND WL 250. MAINTENANCE CUT OUT THE DAMAGED AREA, FABRICATED AND INSTALLED REPAIR PART PER SRM 57-40-3 AND 51-30-2.SDR UPS203093Web · crackedWHILE IN C-CHECK, MAINTENANCE FOUND A CRACK IN THE RIGHT HAND WEB AT THE INBOARD CHORD AT STATION 1223 AND WL 230. MAINTENANCE CUT OUT THE DAMAGED AREA, FABRICATED AND INSTALLED REPAIR IAW SRM 53-10-2.SDR UPS203092Channel · corrodedWHILE IN C-CHECK, MAINTENANCE FOUND CORROSION ON THE AFT CENTER CHANNEL AT STATION 1342 AND WL 250. MAINTENANCE REMOVED AND REPLACED THE CHANNEL IAW SRM 51-10-1, 51-30-2 AND UPS EO 727-5530-4601B.SDR UPS203091Chord · corrodedWHILE IN C-CHECK, MAINTENANCE FOUND CORROSION ON THE FORWARD CENTER CHORD AT STATION 1342 AND WL 250. MAINTENANCE REMOVED AND REPLACED THE CHORD IAW SRM 51-10-1, 51-30-2 AND UPS EO 727-5530-4601B.SDR UPS203090Chord · corrodedWHILE IN C-CHECK, MAINTENANCE FOUND CORROSION ON THE RIGHT HAND OUTBOARD CHORD AT STATION 1342, RBL 30 AND WL 250. MAINTENANCE REMOVED AND REPLACED THE CHORD PER SRM 51-30-2.SDR UPS203089Chord · corrodedWHILE IN C-CHECK, MAINTENANCE FOUND CORROSION ON THE LEFT HAND OUTBOARD CHORD AT STATION 1342, LBL 30 AND WL 250. MAINTENANCE REMOVED AND REPLACED THE CHORD IAW SRM 51-30-02.SDR UPS203088Channel · corrodedWHILE IN C-CHECK, MAINTENANCE FOUND CORROSION ON THE RIGHT HAND CHANNEL AT STATION 1342, RBL 18 AND WL 247. MAINTENANCE REMOVED AND REPLACED THE CHANNEL PER SRM 51-30-2.SDR UPS203087Channel · corrodedWHILE IN C-CHECK, MAINTENANCE FOUND CORROSION ON THE LEFT HAND CHANNEL AT STATION 1342, LBL 18 AND WL 247. MAINTENANCE REMOVED AND REPLACED THE CHANNEL PER SRM 51-30-2.SDR UPS203086Frame · corrodedWHILE IN C-CHECK, MAINTENANCE FOUND CORROSION ON THE RIGHT HAND LOWER FRAME CHORD AT STATION 1342 AND RBL 24. MAINTENANCE REMOVED AND REPLACED THE CHORD PER SRM 51-30-2.SDR UPS203085Frame · corrodedWHILE IN C-CHECK, MAINTENANCE FOUND CORROSION ON THE LEFT HAND LOWER FRAME CHORD AT STATION 1342 AND LBL 24. MAINTENANCE REMOVED AND REPLACED THE CHORD IAW SRM 51-30-2.SDR UPS203084Frame · corrodedWHILE IN C-CHECK, MAINTENANCE FOUND CORROSION ON THE RIGHT HAND FRAME CHORD AT STATION 1342 AND RBL 20. MAINTENANCE REMOVED AND REPLACED THE CHORD.SDR UPS203083Frame · corrodedWHILE IN C-CHECK, MAINTENANCE FOUND CORROSION ON THE LEFT HAND FRAME CHORD AT STATION 1342 AND LBL 20. MAINTENANCE REMOVED AND REPLACED THE CHORD IAW SRM 51-30-2.SDR UPS202244Eel · inopMAINTENANCE REPORTED EMERGENCY EXIT LIGHT OVER MAIN CABIN DOOR INOP. REMOVED AND REPLACED LIGHT ASSY. OPS CHECKED GOOD.
Back to N922UP, cancelled Jan 8, 2008