N929FR, cancelled Nov 16, 2015
Service difficulty reports · 58
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N929FR' AND deregistration_id = 'N929FR-2015-11-16' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N929FR' AND deregistration_id = 'N929FR-2015-11-16' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR F3LA2014111001084Slide · defectiveAIRCRAFT DUE C 7 CHECK. DURING SCHEDULED OPERATIONAL CHECK OF R 2 DOOR SLIDE, LIGHTS DID NOT ILLUMINATE WHEN SLIDE DEPLOYED. R & R R2 DOOR SLIDE WITH SERVICEABLE UNIT IAW TASK CARD TC25831-03. ACFT DUE OUT OF C CHECK 11/11/2014.SDR F3LA2014090801063Bottle · dischargedLOUD NOISE & RUSH OF AIR IN AFT GALLEY AREA RT SIDE OVERHEAD. BLOCK RETURN. FOUND PORTABLE OXYGEN BOTTLE IN AFT CABIN POSITION TO HAVE SUDDENLY DEPRESSURIZED TO ZERO PSI. REPLACED AFT PORTABLE OXYGEN BOTTLE IAW AMM 35-32-42 PAGE BLOCK 401. FLIGHT ATTENDANTSDR F3LA2013050700849Lever · stuckRIGHT EMERGENCY EXIT SLIDE RELEASE LEVER ON DOOR WILL NOT RETURN TO NORMAL POSITION. INSTALLED RELEASE CABLE TEST TOOL AND PERFORMED TEST NUMEROUS TIMES. CABLE RELEASE LEVER NOW RETURNS TO NORMAL POSITION IAW AMM 25-62-43-400-003-A, PG 10 & 11 STEPS(B) THUR SDR F3LA2012121300818Battery Pack · inoperativeEMERGENCY LIGHT EPSU BATTERY 10WL FAILED TEST, HEAVY SERVICE. R & R BATTERY FOR 10WL EPSU. OPS CHECK OK, REF AMM 33-51 -38-000-002A AND 33-51-38-400-002A.SDR F3LA2010050600419Epsu · failedREFERENCE C-CHECK NON ROUTINE N0768. MULTIPLE EMERGENCY LIGHTS FOR SEAT ROWS INOPERATIVE. R & R EMERGENCY LIGHT HARNESS AT SEAT ROW 18 ABC IAW ESPM 20-33-11. R & R DEFECTIVE EPSU AT POSITION 11WL AND POSITION 13WL IAW AMM 33-51-38 PAGE BLOCK 401.SDR F3LA2010043100406Floor Panel · dentedREF HEAVY MX NON ROUTINE N0689. AFT CARGO PIT PANEL 151UG HAS NUMEROUS DENTS. OFF ACFT PART. FABRICATED PANEL 151UG IAW IRM 9701 REV G.SDR F3LA2010043100405Transition Panel · dentedHEAVY MX NON-ROUTINE N0688. AFT CARGO PIT TRANSITION PANEL 152UG HAS NUMEROUS DENTS THROUGHOUT ENTIRE PANEL . OFF ACFT PART. FABRICATED PANEL IAW IRM 9701 REV G.SDR F3LA2010043100404Transition Panel · puncturedREF C-CHECK NON ROUTINE N0686. AFT CARGO COMPARTMENT TRANSITION PANEL 161BF HAS (2) PUNCTURES. OFF ACFT PART. FABRICATED REPLACEMENT TRANSITION PANEL 161BF IAW IRM 9701 REV G.SDR F3LA2010043100403Floor Panel · delaminatedREF HEAVY MX NON-ROUTINE N0687. AFT CARGO PIT PANEL 152TG HAS SEVERAL AREAS OF EDGE DELAMINATION AND SEVERAL SMALL DENTS. OFF ACFT PART. FABRICATED PANEL 152TG IAW IRM 9701 REV G.SDR F3LA2010043100402Transition Panel · dentedREF C-CHECK NON ROUTINE N0682. AFT CARGO COMPARTMENT TRANSITION PANEL 151BE HAS (2) PUNCTURES AND NUMEROUS DENTS THROUGHOUT ENTIRE PANEL. OFF ACFT PART. FABRICATED REPLACEMENT PANEL 151BE IAW MCG IRM 9701 REV G.SDR F3LA2010043100401Transition Panel · delaminatedREF HEAVY MX NON-ROUTINE N0678. AFT CARGO TRANSITION PANEL 151FE HAS DELAMINATION AROUND EDGE. OFF ACFT PART. FABRICATED PANEL IAW IRM 9701 REV G.SDR F3LA2010043100400Transition Panel · dentedREFERENCE C-CHECK NON ROUTINE N0685 AFT CARGO COMPARTMENT TRANSITION PANEL 161CF HAS NUMEROUS DENTS AND BULGES THROUGHOUT PANEL. R & R PANEL 161CF IAW MCG IRM 9701 REV G.SDR F3LA2010043100399Floor Panel · delaminatedREFERENCE HEAVY MX NON-ROUTINE N00680. AFT CARGO PIT PANEL 162BF HAS AREAS OF DELAMINATION AROUND EDGE OF PANEL. FABRICATED PANEL IAW IRM 9701 REV G.SDR F3LA2010043100398Floor Panel · dentedREF HEAVY MX NON-ROUTINE N0679. AFT CARGO PANEL 151DE HAS NUMEROUS DENTS THROUGHOUT PANEL. R & R PANEL.SDR F3LA2010050200409Floor Panel · delaminatedREF C-CHECK NON ROUTINE N0587. CABIN FLOOR PANEL 222CF IS DELAMINATED. OFF ACFT PART. FABRICATED REPLACEMENT CABIN FLOOR PANEL 222CF IAW IRM 9701 REV G.SDR F3LA2010050600418Floorbeam · corrodedCORROSION ON FLOORBEAM JUST INBD OF Y765 AT FRAME 68. R & R FLOORBEAM IAW A319 SRM 51-42-11, PAGE 1, STEP A, 51-44-11, PAGE 1 AND 51-21-11 PAGE 1 TABLE 1.SDR F3LA2010050500417Floorbeam · corrodedREFERENCE C-CHECK NON ROUTINE N0479. CORROSION ON NUT PLATE HOLES AT SPLICE ON FLOORBEAM AT Y-1292 FRAME 69. UPPER AND LOWER SIDES OF BEAM. R & R FLOORBEAM IAW SRM 51-72-11.SDR F3LA2010050500416Floorbeam · corrodedREFERENCE C-CHECK NON ROUTINE N0481. CORROSION ON PREVIOUS REPAIR AT FLOORBEAM, Y1292, FRAME 66. R & R FLOORBEAM IAW SRM 51-72-11, SHEETS 1 THROUGH 6.SDR F3LA2010050500415Sill · corrodedREFERENCE C-CHECK NON ROUTINE N0480. CORROSION ON L-2 DOOR SILL PLATE AT SPLICE FRAME 66. REPAIRED L-2 DOOR SILL PLATE IAW SRM 53-41-11 FIGURE 201 REPAIR PRINCIPLE 6.SDR F3LA2010050400412Sill · corrodedC-CHECK NON ROUTINE N0482. CORROSION ON R-2 DOORSILL PLATE AT FRAME 66 SPLICE. R & R DOOR SILL AND 3 EACH SCUFF PLATES IAW SRM 51-72-11 AND AMM 53-45-15-400-001.SDR F3LA2010050200411Support Frame · corrodedREFERENCE C-CHECK NON ROUTINE N0551. RIGHT HAND CABIN FLOOR SHEAR PLATE EXTRUSION IS CORRODED. REPLACED EXTRUSION REF A319 SRM 41-42-11, SRM 51-21-11 AND 51-72-11.SDR F3LA2010050200410Floorbeam · corrodedREFERENCE HEAVY MX NON-ROUTINE N0534. CORROSION DISCOVERED ON NUTPLATE HOLES ON FLOORBEAM Y1292. R & R FLOORBEAM.SDR F3LA2010043100397Floorbeam · corrodedREF C-CHECK NON ROUTINE N0478. CORROSION IN (2) AREAS OF FLOORBEAM -Y765 AT FRAME 68. R & R FLOORBEAM IAW A319 SRM 51-42-11 PAGE 11.SDR F3LA2010050500414Shear Plate · corrodedREFERENCE C-CHECK NON ROUTINE N0318. SHEAR PLATE AT FRAME 69 TO FRAME 70 BETWEEN STRINGER 23 RT AND 24 RT HAS CORROSION IN 15 AREAS. R & R SHEAR PLATE IAW SRM 51-42-11 PARAGRAPH 6 AND 7 AND EO A0-53EO-31434.SDR F3LA2010050400413Shear Plate · corrodedREF C-CHECK NON ROUTINE N0317. SHEAR PLATE AT FRAME 69 TO 70 BETWEEN STRINGER 23 LT AND STRINGER 24 LT HAS 6 SQUARE INCHES OF CORROSION. R & R SHEAR PLATE IAW SRM 51-42-11 PARAGRAPH 6 AND 7 AND EO NR A0-53EO-31434.SDR F3LA2010050200408Transition Panel · delaminatedREF AERO FRAME HEAVY MX NON-ROUTINE N0336. TRANSITION PANEL 131BF HAS AREAS OF PUNCTURES DENTS AND EDGE DELAMINATION. OFF ACFT PART. FABRICATED PANEL IAW IRM 9701 REV G.SDR F3LA2010050200407Transition Panel · dentedREF C-CHECK NON ROUTINE N0299. FWD CARGO COMPARTMENT TRANSITION PANEL 131DG HAS NUMEROUS DENTS ACCROSS ENTIRE LENGTH OF PANEL. OFF ACFT PART. FABRICATED TRANSITION PANEL 131DG IAW MCG IRM 9701 REV G.SDR F3LA2010043100395Transition Panel · dentedREFERENCE HEAVY MX NON ROUTINE N0319. FWD CARGO PIT TRANSITION PANEL HAS NUMEROUS DENTS THROUGHOUT ENTIRE LENGTH OF PANEL. FABRICATED REPLACEMENT PANEL IAW IRM9701 REV G. R & R PANEL.SDR F3LA2010043000394Bracket · crackedREF C4/SI CHECK NON-ROUTINE N0215. LT WING L/E TAI DUCT CUT OUT UPPER SURFACE OTBD PANEL ATTACH ANGLE HAS A 1.5 INCH CRACK. R & R BRACKET.SDR F3LA2010043100396Floor Panel · dentedREFERENCE HEAVY MX NON-ROUTINE N0684. AFT CARGO PIT FLOOR PANEL 162CF HAS NUMEROUS DENTS. R & R PANEL.SDR F3LA2009062200089Servo Control · inoperativeFLIGHT CREW MADE AN UNSCHEDULED LANDING IN RSW DUE TO "SPOILER FAULT 4". THE AIRCRAFT RETURNED TO DEN ON A SPECIAL FLIGHT PERMIT. MAINTENANCE REMOVED AND REPLACED THE NR 4 RIGHT SPOILER SERVO AND PERFORMED RIG, OPERATIONAL AND LEAK CHECK PER AMM 27-64-51 PB SDR F3LA2009031100041Computer · smokeDURING THE BOARDING PROCESS, BOTH PILOTS DETECTED ELECTRONIC OVERHEAT ODOR. MAINTENANCE PERFORMED TROUBLESHOOTING USING REFERENCE TSM 24-00-00-810-823, ELECTRICAL BURNING SMELL OR FUMES FOUND IN THE CABIN, COCKPIT, CARGO, OR AVIONICS COMPARTMENT AND IDENTIFIESDR F3LA200800604Floor Panel · corrodedREF: NON ROUTINE C050752. DURING C3 C-CHECK, INSPECTION FOUND (1) MOUNT BUSHING CORRODED ON FLOOR PANEL 261DE. MAINTENANCE REMOVED AND REPLACED MOUNT BUSHING ON C-CHECK CARD NR C5341032. UPON COMPLETION OF THE REPAIR, IT WAS INSPECTED AND FOUND ACCEPTABLE. (KSDR F3LA200800601Floorbeam · corrodedDURING C3 C-CHECK, INSPECTION NOTED SEVERAL NUT PLATE HOLES ON FRAME Y-1292 BETWEEN FRAME 66 AND FRAME 68 HAS CORROSION. MAINTENANCE REMOVED AND REPLACED FLOORBEAM IN ACCORDANCE WITH A319 SRM 51-42-11.SDR F3LA200800600Floorbeam · corrodedREF NON ROUTINE C050600. DURING C3 C-CHECK, INSPECTION NOTED FWD NUT PLATE HOLE ON FRAME Y-1292 AT FRAME 66, HAD CORROSION. MAINT REMOVED CORROSION FROM HOLE, FABRICATED REPAIR BUSHING AND INSTALLED IAW WITH THE REQUIREMENTS OF ENGINEERING AUTHORIZATION NR A9SDR F3L2008F00005Floor Support · corrodedREF: NON ROUTINE C050602. DURING C3 C-CHECK, INSPECTION NOTED SEVERAL NUT PLATE HOLES ON FRAME Y-1292 BETWEEN FRAME 66 AND FRAME 68, HAD CORROSION. MAINTENANCE REMOVED AND REPLACED FLOORBEAM IAW WITH THE REQUIREMENTS OF A319 SRM 51-42-11. UPON COMPLETION OF THSDR F3LA200800599Floorbeam · corrodedREF NON ROUTINE C050605. DURING C3 C-CHECK, INSPECTION NOTED SEVERAL NUT PLATE HOLES ON FRAME Y-1292 BETWEEN FRAME 66 AND FRAME 68, HAD CORROSION. MAINT REMOVED CORROSION FROM HOLES, FABRICATED REPAIR PROFILE AND FILLER, AND INSTALLED IAW THE REQUIREMENTS OFSDR FELA200800597Floor Panel · corrodedREFERENCE NON ROUTINE C050515. DURING C3 C-CHECK INSPECTION NOTED FLOOR PANEL 261FF HAS CORROSION ON LOWER SURFACE. MX R&R FLOOR PANEL IN ACCORDANCE WITH THE REQUIREMENTS OF A319 AMM 53-42-12 PB 401. UPON COMPLETION OF THE REPAIR, IT WAS INSPECTED AND FOUNDSDR F3LA200800596Floor Panel · puncturedREFERENCE NON ROUTINE C050458. DURING C3 C-CHECK INSPECTION NOTED TRANSITION PANEL 131CF WAS PUNCTURED. MX REPAIRED CARGO COMPARTMENT TRANSITION PANEL IN ACCORDANCE WITH THE REQUIREMENTS OF A319 SRM 53-02-00 FIGURE 204. UPON COMPLETION OF THE REPAIR, IT WASSDR F3LA200800595Floor Panel · puncturedREFERENCE NON ROUTINE C050457. DURING C3 C-CHECK INSPECTION NOTED TRANSITION PANEL 131EG WAS PUNCTURED. MX REPAIRED CARGO COMPARTMENT TRANSITION PANEL IN ACCORDANCE WITH THE REQUIREMENTS OF A319 SRM 53-02-00 FIGURE 204. UPON COMPLETION OF THE REPAIR, IT WASSDR F3LA200800594Floor Panel · puncturedREFERENCE NON ROUTINE C050375. DURING C3 C-CHECK, INSPECTION NOTED TRANSITION PANEL 161CF WAS PUNCTURED. MX REPAIRED CARGO COMPARTMENT TRANSITION PANEL IN ACCORDANCE WITH THE REQUIREMENTS OF A319 SRM 53-02-00 FIGURE 204. UPON COMPLETION OF THE REPAIR, IT WASDR F3LA200800593Floor Panel · puncturedREFERENCE NON ROUTINE C050374. DURING C3 C-CHECK, INSPECTION NOTED TRANSITION PANEL 161BF WAS PUNCTURED. MX REPAIRED CARGO COMPARTMENT TRANSITION PANEL IN ACCORDANCE WITH THE REQUIREMENTS OF A319 SRM 53-02-00 FIGURE 204. UPON COMPLETION OF THE REPAIR, IT WASDR F3LA200800592Floor Panel · puncturedREFERENCE NON ROUTINE C050372. DURING C3 C-CHECK, INSPECTION NOTED TRANSITION PANEL I51FF WAS PUNCTURED. MX REPAIRED CARGO COMPARTMENT TRANSITION PANEL IN ACCORDANCE WITH THE REQUIREMENTS OF A319 SRM 53-02-00 FIGURE 204. UPON COMPLETION OF THE REPAIR, IT WASDR F3LA200800591Floor Panel · puncturedREFERENCE NON ROUTINE C050370. DURING C3 C-CHECK, INSPECTION NOTED TRANSITION PANEL I51UG WAS PUNCTURED. MX REPAIRED CARGO COMPARTMENT TRANSITION PANEL IN ACCORDANCE WITH THE REQUIREMENTS OF A319 SRM 53-02-00 FIGURE 204. UPON COMPLETION OF THE REPAIR, IT WASDR F3LA200800590Floor Panel · puncturedREFERENCE NON ROUTINE C050368. DURING C3 C-CHECK, INSPECTION NOTED TRANSITION PANEL I51TG WAS PUNCTURED. MX REPAIRED CARGO COMPARTMENT TRANSITION PANEL IN ACCORDANCE WITH THE REQUIREMENTS OF A319 SRM 53-02-00 FIGURE 204. UPON COMPLETION OF THE REPAIR, IT WASDR F3LA200800589Floor Panel · puncturedREFERENCE NON ROUTINE C050366. DURING C3 C-CHECK, INSPECTION NOTED TRANSITION PANEL I52UG WAS PUNCTURED. MX REPAIRED CARGO COMPARTMENT TRANSITION PANEL IN ACCORDANCE WITH THE REQUIREMENTS OF A319 SRM 53-02-00 FIGURE 204. UPON COMPLETION OF THE REPAIR, IT WASDR F3LA200800598Floor Panel · corrodedREFERENCE NON ROUTINE C050516. DURING C3 C-CHECK, INSPECTION NOTED FLOOR PANEL 262FF HAS CORROSION ON LOWER SURFACE. MX R&R FLOOR PANEL IN ACCORDANCE WITH THE REQUIREMENTS OF A319 AMM 53-42-12 PB 401. UPON COMPLETION OF THE REPAIR, IT WAS INSPECTED AND FOUNSDR F3LA200800602Hinge · damagedREF NON ROUTINE C050746. DURING C3 C-CHECK, INSP FOUND DAMAGE ON THE RT NR (4) SPOILER ANTI-ROTATION WEB. MAINT MACHINED AREA, FABRICATED REINFORCING PLATE AND PROTECTED AREA IAW EA NR A9-57R-30609. UPON COMPLETION OF THE REPAIR, IT WAS INSPECTED AND FOUND ACCSDR F3LA200800603Hinge · damagedREF: NOT ROUTINE C050745. DURING C3 C-CHECK, INSPECTION FOUND DAMAGE ON THE RT NR (2) SPOILER ANTI-ROTATION WEB. MAINT MACHINED AREA, FABRICATED REINFORCING PLATE AND PROTECTED AREA IAW ENGINEERING AUTHORIZATION NR A9-57R-30610. UPON COMPLETION OF THE REPAIR, SDR F3LA200800409Unknown · odorDURING FLIGHT, FLIGHT CREW NOTED AN ODOR OF GAS IN AFT GALLEY. MAINT INSPECTED AC FOR UNSATISFACTORY CABIN AIR QUALITY IAW TSM 21-00-00-810-802. NO ODOR OR SOURCE OF ODOR WAS NOTED. FIRE DEPARTMENT AND HAZMAT CREW INSPECTED THE CABIN AND CARGO COMPARTMENT,
Back to N929FR, cancelled Nov 16, 2015