N957R, cancelled Apr 24, 2002
Service difficulty reports · 122
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N957R' AND deregistration_id = 'N957R-2002-04-24' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N957R' AND deregistration_id = 'N957R-2002-04-24' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR RRXA003351Panel · delaminatedDURING A MAINTENANCE VISIT FOUND A DELAMINATED PANEL ON THE LT WING LWR T/E AT STA XW 5.00 TO XW 98, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.SDR RRXA003350Panel · delaminatedDURING A MAINTENANCE VISIT FOUND DELAMINATION AND A DENTED HOLE TO THE LT WING LWR SURFACE T/E PANEL UNDER HYD TANK, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.SDR RRXA003349Panel · delaminatedDURING A MAINTENANCE VISIT FOUND DELAMINATION TO THE LT WING LWR SURFACE T/E PANEL AT STA 98, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.SDR RRXA003348Panel · delaminatedDURING A MAINTENANCE VISIT FOUND DELAMINATION TO THE LT WING LWR SURFACE T/E PANEL AT STA XW 98 TO XW 138, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.SDR RRXA003347Panel · delaminatedDURING A MAINTENANCE VISIT FOUND DELAMINATION TO THE LT WING LWR SURFACE T/E PANEL AT STA 138 TO 214, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.SDR RRXA003346Skin · delaminatedDURING A MAINTENANCE VISIT FOUND DELAMINATION TO THE LEFT WING LWR SURFACE T/E PANEL NR 577B, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.SDR RRXA003345Skin · crackedDURING A MAINTENANCE VISIT FOUND A CRACK TO THE O/B FLAP O/B EXHAUST GATE FLANGE, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.SDR RRXA003344Angle · crackedDURING A MAINTENANCE VISIT FOUND A CRACK TO THE TOP RIB ANGLE AT THE LEFT O/B FLAP I/B SCISSOR LINK, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.SDR RRXA003343Skin · crackedDURING A MAINTENANCE VISIT FOUND A CRACK TO THE SKIN AT THE LEFT I/B FLAP BOTTOM, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.SDR RRXA003342Channel · crackedDURING A MAINTENANCE VISIT FOUND A CRACK TO THE LEFT I/B FLAP I/B TRAILING EDGE WEDGE CHANNEL, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.SDR RRXA003341Floor Panel · crackedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE AND A CRACK TO THE COCKPIT FLOOR PANEL NR 677, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.SDR RRXA003340Floor Panel · crackedDURING A MAINTENANCE VISIT FOUND CORROSION AND A CRACK TO THE TOP AND BOTTOM OF THE COCKPIT FLOOR PANEL 679, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.SDR RRXA003339Floor Panel · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO BOTH SIDES OF THE COCKPIT FLOOR PANEL UNDER F/E''S DESK, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.SDR RRXA003338Floor Panel · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE COCKPIT FLOOR PANEL UNDER FE''S CONSOLE, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.SDR RRXA003337Fitting · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE CIRCUMFERENTIAL FRAME FITTING AT STA 1480 AND L21R, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.SDR RRXA003336Fitting · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMGE TO THE FRAME TO CUSP FITTING AT STA 1460 AND L21R, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.SDR RRXA003335Finger Doubler · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE AND POPPED RIVET HEADS TO THE UPPER SURFACE W/W FINGER DOUBLER BETWEEN STA 902 - 920 AND LBL 4 LBL -4 Z AXIS -10, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.SDR RRXA003334Panel · delaminatedDURING A MAINTENANCE VISIT FOUND THE COCKPIT FLOOR SEPARATED AT STA -12 TO -32, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.SDR RRXA003352Skin · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE ALONG THE MOUNTING SURFACE OF THE NR 2 ADF AT STA 145 - 170 AND L36 TO L35L, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.SDR RRXA003290Rib · crackedDURING A MAINTENANCE VISIT FOUND CORROSION AT RIGHT I/B FLAP-RIB-LOC AT STA XW 64 18 - 20 INCHES AFT OF FLAP FRONT SPAR, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.SDR RRXA003289Angle · crackedDURING A MAINTENANCE VISIT FOUND A CRACK TO THE ATTACH ANGLE AT THE RIGHT W/W AT STA XWO ABOVE L24R, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.SDR RRXA003291Fitting · misdrilledDURING A MAINTENANCE VISIT FOUND A DRILLED AREA TO THE CIRCUMFERENTIAL FRAME FITTING AT STA 640 AND L21R, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.SDR RRXA003292Fitting · crackedDURING A MAINTENANCE VISIT FOUND A CRACK TO THE INTERCOSTAL ATTACH FITTING BETWEEN MLG DOORS AT STA 930, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.SDR RRXA003299Stringer · chafedDURING A MAINTENANCE VISIT FOUND A CHAFED STRINGER SIDEWALL AND HOLES ELONGATED ON THE NR 4 THRUST REVERSER, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.SDR RRXA003298Bulkhead · crackedDURING A MAINTENANCE VISIT FOUND A CRACK AND MISSING FASTENERS TO THE A & B PIT CENTER DIVIDER WALL, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.SDR RRXA003297Intercostal · crackedDURING A MAINTENANCE VISIT FOUND A CRACKED INTERCOSTAL BETWEEN MLG DOORS AND LT AND RT ATTACH FITTINGS AT STA 902, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.SDR RRXA003296Intercostal · crackedDURING A MAINTENANCE VISIT FOUND A CRACK TO THE INTERCOSTAL BETWEEN MLG DOORS AT STA 940, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.SDR RRXA003295Fitting · crackedDURING A MAINTENANCE VISIT FOUND A CRACK TO THE INTERCOSTAL ATTACH FITTINGS BETWEEN MLG DOORS AT STA 960, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.SDR RRXA003294Fitting · crackedDURING A MAINTENANCE VISIT FOUND A CRACK TO THE INTERCOSTAL ATTACH FITTING BETWEEN MLG DOORS AT STA 950, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.SDR RRXA003293Fitting · crackedDURING A MAINTENANCE VISIT FOUND A CRACK TO THE INTERCOSTAL ATTACH FITTINGS BETWEEN MLG DOORS AT STA 890, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.SDR RRXA003308Web · tool damageDURING A MAINTENANCE VISIT FOUND DRILL HOLES AND DRILL STARTS IN WEB AT STA 1340 RT, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.SDR RRXA003307Frame · misdrilledDURING A MAINTENANCE VISIT FOUND A DRILL START AT FLOOR LEVEL AT STA 1280 RT, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.SDR RRXA003306Longeron · misdrilledDURING A MAINTENANCE VISIT FOUND DRILL STARTS AND HOLES IN STRINGER AT STA 440 RT, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.SDR RRXA003305Web · misdrilledDURING A MAINTENANCE VISIT FOUND HOLES IN WEB BETWEEN STA 260 - 280 LT, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.SDR RRXA003304Link · wornDURING A MAINTENANCE VISIT FOUND EXCESSIVE PLAY IN THE LEFT O/B FLAP MID SCISSOR LINK BOLT, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.SDR RRXA003303Link · wornDURING A MAINTENANCE VISIT FOUND EXCESSIVE PLAY TO THE LEFT O/B FLAP LWR SCISSOR LINK BOLT, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.SDR RRXA003302Structure · crackedDURING A MAINTENANCE VISIT FOUND A CRACKED CORNER AT RIVET HOLE TO THE RT MAIN GEAR DOOR FWD LWR END, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.SDR RRXA003301Panel · delaminatedDURING A MAINTENANCE VISIT FOUND A DELAMINATED AND DETERIORATED PANEL 632 TOP AND O/B SIDE, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.SDR RRXA003300Longeron · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE BETWEEN STA 1080 - 1100 AND L36, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.SDR RRXA003212Skin · dentedDURING A MAINTENANCE VISIT FOUND SEVERAL DING AREAS ON THE LEFT I/B FLAP BOTTOM, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.SDR RRXA003176Structure · wornDURING A MAINTENANCE VISIT FOUND A WORN EDGE ON THE AFT NR 2 ENGINE LT PYLON SKIRT, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.SDR RRXA003175Frame · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE FRAME LOWER CHORD IN -A- PIT AT STA 160 AND L36, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.SDR RRXA003174Frame · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE FRAME IN -A- PIT AT STA 180 AND L36L TO L35L, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.SDR RRXA003173Floorbeam · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE AND POPPED RIVETS AT BEAM LOWER CHORD/WEB AT STA 702 LBL 45 TO 52.5 & LBL 55.5 TO 61 Z AXIS -7 FWD AND AFT SIDE OF BEAM, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.SDR RRXA003177Mount · gougedDURING A MAINTENANCE VISIT FOUND A GOUGED FWD MOUNT ON THE NR 3 ENGINE, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.SDR RRXA003180Bracket · crackedDURING A MAINTENANCE VISIT FOUND A CRACK TO THE RIGHT I/B LWR SCISSOR PANEL SUPPORT BRACKET, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.SDR RRXA003179Web · crackedDURING A MAINTENANCE VISIT FOUND A CRACK IN WEB WHERE WEDGE ATTACH POINT IS ON THE RIGHT I/B FLAP AT STA XW 75, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.SDR RRXA003178Floorbeam · crackedDURING A MAINTENANCE VISIT FOUND CORROSION EXFOLIATION TO THE FLOORBEAM AT STA 702 AND X+50, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.SDR RRXA003099Frame · crackedDURING A MAINTENANCE VISIT FOUND A CRACK TO THE LEFT WING O/B FLAP I/B FRAME, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.SDR RRXA003098Link · gougedDURING A MAINTENANCE VISIT FOUND A GOUGE TO THE SUPPORT AFT LINK ON THE LEFT I/B FLAP SUPPORT AT STA 98 LT, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.
Back to N957R, cancelled Apr 24, 2002