SDR UALA2008111305931Indicator · unknownABORTED T/O AT 100 KNOTS. ACCOUNT OF FLAG IN VIEW ON F/O'S AIRSPEED INDICATOR. CHECKED PER AMM05-51-07. BRAKE TEMP COOLED 54 MINUTES PER FIG 201. BRAKE TEMP RETURNED TO NORMAL, NO DAMAGE TO BRAKES.SDR 2008UALA05901Panel · damagedRIGHT WING INBOARD LWR FIXED T/E PANEL NEXT TO BODY FAIRING DAMAGED AT WBL 71.26. REPLACED PANEL.SDR 2008UALA05905Slide · out of positionDOOR 1R SLIDE GAUGE NOT VISIBLE. FOUND SLIDE IN PACK MISALIGNED. REMOVED SLIDE, REALIGNED SLIDE IN PACK SO GAUGE VISIBLE. REINSTALLED SLIDE. OK FOR SERVICE.
SDR 2008UALA05893Light · inoperativeFWD 1 FT SECTION OF CABIN FLOOR MOUNTED EMERGENCY ESCAPE PATH LIGHTING IS INOP. REPLACED SECTION OF EMERGENCY LIGHT. OP CHECKS GOOD.SDR 2008UALA05898Lamp · inoperativeAFT 15 FT OF CABIN FLOOR MOUNTED EMERGENCY ESCAPE PATH LIGHTING IS INOP. REMOVED, DRIED & REINSTALLED AFT THREE LAMPS. OP CHKS NORMAL.
SDR 2008UALA05899Fuse · inoperativeEXTERIOR EMERGENCY EXIT LIGHT INOP AT DOOR 2R. FOUND BLOWN FUSE ON POWER SUPPLY. REPLACED AT DOOR 2R. OP CHECKS NORMAL.SDR 2008UALA05889Fire Loop · faultyAPU FIRE BELL & HANDLE ILLUMINATE DURING TEST. APU FIRE DETECTOR FOUND FAULTY. REPLACED APU TAILPIPE OVERHEAT FIRE LOOP. APU FIRE DETECTION SYSTEM OPS CHECKS GOOD.SDR 2008UALA05745Csd · overservicedOIL TEMP INDICATION BOTH ENGINES. RTFL. FOUND NR 1 AND 2 CSD OIL LEVEL HIGH. DRAINED OIL TO PROPER LEVELS. REPLACED NR 1 OIL TEMP INDICATOR AND NR 2 CSD.
SDR 2008UALA05719Connector · underservicedF/O SIDE OXYGEN MASK COMM CONNECTOR DISCONNECTED. REPAIRED O2 BOX CONNECTOR.SDR 2008UALA05720Control Panel · faultyAFTER REPLACEMENT OF NR 2 CARGO FIRE BOTTLE, SQUIB ACTIVATED WHEN CIRCUIT BREAKER PUSHED BACK IN. FIRE BOTTLE AND SQUIB WILL REQUIRE REPLACEMENT. CONSTANT .5 VOLTS AT SQUIB CONNECTOR D9497 BETWEEN PIN 1 AND PIN 2. REPLACED CARGO FIRE CONTROL PANEL, NR 2 FIRSDR 2008UALA05699Switch · defectiveFOUND EMERGENCY LIGHT TOGGLE SWITCH ON P5 PANEL TO BE DEFECTIVE, MISSING PLUNGER FOR MICRO SWITCH IN CIRCUIT FOR NOT ARMED LIGHT WITH SWITCH IN OFF POSITION. INSTALLED NEW SWITCH ON THE P5 PANEL.SDR 2008UALA06216Slide · malfunctionedDOOR 1L PARTIAL SLIDE DEPLOYMENT. REMOVED SLIDE AND CONTAINER FROM L1 DOOR. INSTALLED NEW SLIDE.SDR 2008UALA05632Transceiver · faultyFIRST OBSERVERS OXYGEN MASK WILL NOT TRANSMIT WITH MASK ON. FOUND NR 3 TRANSCEIVER FOUND FAULTY. REPLACED TRANSCEIVER. OP CHECKS OKAY.SDR 2008UALA05633Inverter · inoperativeEMERGENCY LIGHT INOPERATIVE FROM ROW 14 TO BACK OF ACFT. FOUND FAULTY INVERTER. REPLACED INVERTER. TESTS OKAY.SDR 2008UALA06222Fan · faultyCREW REPORT: ALT EQUIP COOLING FAN INTERMITTENT AT FL250 SAMC TEXT: PACKS AND CABIN PRESSURIZATION NORMAL, ALT EQUIP COOLING EXHAUST FAN 'OFF' LIGHT FLICKERING ON INTERMITTANTLY. FOUND EXHAUST DUCT FORWARD OF MUFFLER CLOGGED WITH DUST AND DIRT RESTRICTING ESDR 2008UALA05638Audio Panel · failedUNABLE TO TRANSMIT ON ANY ACP SELECTIONS FROM CAPTAIN'S SIDE. RTFL. REPLACED THE CAPT'S ACP AND THE REMOTE ELECTRONICS UNIT.SDR 2008UALA05574Smoke Detector · failedFWD PIT FIRE DETECTOR LOOP -A SHOWS FAILED AND CANNOT BE RESET. FOUND FAULTY SMOKE DETECTOR. REPLACED FWD "A" LOOP FWD PIT SMOKE DETECTOR. OP CHECKS NORMAL. ACFT OK FOR SERVICE.SDR 2008UALA05566Oxygen Bottle · low pressureCREW O2 LOW. FOUND FAULTY O2 BOTTLE SUSPECT FAULTY O-RING. REPLACED O2 BOTTLE. AC OK FOR SERVICE.SDR UALA2008111305512B-Nut · looseCREW O2 AT 1550 PSI AND DROPPING. FOUND LOOSE B-NUT. FOUND AND REPAIRED THREE LEAKS ON HIGH PRESS SIDE. REPLACED 90 DEGREE ELBOWS AT BOTH ENDS OF HARD LINE FROM CROSS FITTING TO FILL VALVE. SECURED LEAKING B-NUT AT CROSS FITTING TO STEP DOWN REG SVCED SYSTSDR 2008UALA05513Inverter · faultyEMERGENCY PATH LIGHTING DOES NOT ILLUMINATE THE ENTIRE AIRCRAFT WITH SWITCH IN THE ON POSITION. SUSPECT INVERTER FAULTY. REPLACED INVERTER M1389 REFERENCE AMM 33-51-93. AC OK FOR SERVICE.SDR 2008UALA05514Lamp · inoperativeEMERGENCY LIGHT STRIP FOR SEAT ROWS 1 AND 2 IS INOPERATIVE. FOUND FAULTY LAMP STRIP. REPLACED LAMP STRIP OP CHECK GOOD. AC OK FOR SERVICE.
SDR 2008UALA05504Cap · missingEMER LIGHT STRIP END CAP MISSING AT 1B.SDR 2008UALA05476Light · unsecureEMERGENCY LIGHT INOPERATIVE ROW 16 AND AFT. SECURED EMERGENCY LIGHT AND OPS CHECKED GOOD. AC OK FOR SERVICE.SDR 2008UALA05488Check Valve · faultyPRESSURIZATION PROBLEM. RTFL. FAULTY CHECK VALVE. REPLACED CHECK VALVE.SDR 2008UALA05460Feeder Cable · damagedEMERGENCY LIGHTS ARE INOP FROM ROW 16 TO AFT GALLEY. REPLACED WALL FEEDER CABLE. EMERGENCY LIGHT BATTERY NEEDS TO CHARGE TO FINISH OPS CHECK.SDR 2008UALA05426Lamp · inoperativeEMERGENCY LIGHT LAMP INOP ROW 11. REPLACED EMERGENCY LIGHT LAMP.SDR 2008UALA04373Charger · inoperativeFWD OVERHEAD EMERGENCY EXIT SIGN AND 1L EMERGENCY EXIT SIGNS INOP. *S/D* REMOVED & REPLACED BATTERY CHARGER LT FWD.SDR 2008UALA05411Shutoff Valve · faultyANTI-SKID INOP LIGHT ON WITH SWITCH ON -CONSTANTLY. LIGHT ON WHEN PARK BRAKE ON, HOWEVER LIGHT GOES OFF AFTER PARK BRAKE RELEASED, PROG TEXT PARKING BRAKE SHUTOFF VALVE, OPS CHECKED NORMAL. AC OK FOR SERVICESDR 2008UALA04356Power Supply · faultyEMERGENCY EXIT LIGHT OVER DOOR 2L STAY ON WITH LIGHTS OFF. *S/D* REPLACED POWER SUPPLY & BATTERY. CHECKS NORMAL.SDR 2008UALA04357Light · inoperativeEXTERIOR EMERGENCY LIGHT AFT OF DOOR 1L IS INOP. *S/D* REPLACED LIGHT ASSEMBLY. OP CHECKS GOOD.SDR 2008UALA04327Connector · contaminatedFLOOR EMERGENCY EXIT LIGHTING INOP ROW 15 AND AFT. FOUND MOISTURE AT FLOOR STRIP CONNECTORS. DRIED AND CLEANED ALL CONNECTORS FROM ROWS 15 AFT. OP CHECKS OKAY.
SDR 2008UALA04284Feeder Cable · damagedEMERGENCY FLOOR MOUNTED STRIP LIGHTING ROWS 15-21 INOP. FOUND POWER FEEDER CABLE TO BE FAUTLTY. REPLACED POWER DISTRIBUTION STRIP AND ALL OPS NORMAL. ACFT OK FOR SERVICE.SDR 2008UALA04262Light · malfunctionedAFT DOOR GREEN EMERGENCY EXIT LIGHTS AND 2 STOW BIN LIGHTS STAYING ON.SDR 2008UALA04266Structure · dentedFUSELAGE ON LEFT SIDE FWD OF ENGINE IS DENTED.SDR 2008UALA04270Light · faultyAFT GALLEY EEL LIGHT STRIP NOT WORKING.SDR 2008UALA04241Retainer · deformedPRESSURIZATION INDICATION. RTFL. FOUND FOUND ZEE RETAINER ON FO'S SLIDING WINDOW DEFORMED AT LOWER AFT CORNER. STRAIGHTENED RETAINER AND AREA OF DISBOND IS WITHIN LIMITS. INSTALLED SMALL AMOUNT OF SPEED TAPE AT AREA OF DISBOND. PRESSURIZED ACFT AND FOUND NO SDR 2008UALA04253Coupling · leakingCREW OXYGEN SYSTEM LOW. RECORD PRESSURE PRIOR TO SERVICING. CREW COMMENTS: 1275 PSI AND SLOWLY DECREASING. FOUND THE JUMP SEAT MASK CONNECTION POINT TO ACFT O-RING DAMAGED. REPLACED WITH NEW MASK, OP CHECKED MASK, NORMAL. SERVICED O2 LEVELS. ACFT OK FOR SDR 2008UALA04258Lamp · damagedAFT GALLEY EEL LIGHT DAMAGED.SDR 2008UALA04254Slide · unsecureDOOR 1L SLIDE IS FALLING OUT. SUSPECT SLIDE IMPROPERLY INSTALLED. REINSTALLED SLIDE IAW MM 25-61-35 PG 201. AC OK FOR SERVICE.SDR 2008UALA04200Light · brokenEMERGENCY LIGHT STRIP IN AFT OF AC IS LOOSE. FOUND BROKEN LIGHT ASSEMBLY. REPAIRED LIGHTASSEMBLY OP CHECK GOOD. ACFT OK FOR SERVICE.SDR 2008UALA04207Inverter · inoperativeEMERGENCY LIGHTS INOP ROWS 9-15. REPLACED INVERTER M1388. OP TEST OKAY.SDR 2008UALA04171Window · crackedCREW REPORTS, THE CAPTAIN'S NR 4 WINDOW PANE IS CRACKED.SDR 2008UALA04173Unknown · unknownEQUIPMENT COOLING EXHAUST OFF LIGHT ILLUM. REPLACE MULTIPLE PARTS (ALT EXHAUST BLOWER, EXHAUST AIRFLOW DETECTOR, TURBOFAN VALVE)SDR 2008UALA04194O-Ring · leakingCREW O2 INDICATES 680 PSI. FOUND THE JUMP SEAT MASK CONNECTION POINT TO ACFT O-RING DAMAGED. REPLACED WITH NEW MASK, OPS MASK NORMALLY, SERVICED O2. ACFT OK FOR SERVICE.SDR 2008UALA04193Smoke Detector · inoperativePAX WAS SMOKING IN AFT LT LAV AND SMOKE DET DID NOT GO OFF. FOUND FAULTY SMOKE DETECTOR. REPLACED SMOKE DETECTOR, OP CHECKED GOOD.
SDR UALA2008111304171Window · crackedCREW REPORTS THE CAPTAIN'S NR 4 WINDOW PANE IS CRACKED. AWAITING SHOP FINDINGS. REPLACED WINDOW.SDR 2008UALA04177Quick Disconnect · leakingCOCKPIT O2 STILL LEAKING, LOST 200 LBS IN 2 LEGS. *S/D* FOUND 1ST OFFICER'S MASK LEAKING AT QUICK DISCONNECT FITTING IN O2 BOX. REPLACED 1ST OFFICER'S MASK. NO LEAKS DETECTED. CHECKED GOOD.
SDR 2008UALA04165Control Panel · malfunctionedCARGO DECT FWD PIT B-LOOP ON IN FLIGHT. TEST RESET SYSTEM, BEGAN TO FLICKER AGAIN. FOUND FAULTY FIRE PANEL. REPLACED FAULT ANNUNCIATION FIRE PANEL AS A PRECAUTIONARY ACTION. SYSTEM OPERATES NORMAL.SDR 2008UALA04164Lamp · inoperativeFLIGHT DECK EMERGENCY LIGHT INOP. *S/D* RELAMPED, OP CHECKS OKAY.SDR 2008UALA04166Lamp · inoperativeLEFT OVERWING HATCH ILLUMINATION EMERGENCY LIGHTS INOP. *S/D* RELAMPED WITH 2EA LAMPS.