SDR UALA2013053003757Fire Loop · shortedFIRE LOOP B FAULT DISPLAYED ON UPPER ECAM SCREEN. PERFORMED MT 26-001 AND TSM 26-12-00-810-808-A, FOUND FAN DETECTOR LOOP "B" HIGH RESISTANCE READING OUT OF LIMITS. R & R NR 2 ENG FAN LOOP ASSY. OPS CHECKED GOOD.SDR UALA2013053003750Oxygen Mask · damagedF/O OXYGEN HARNESS FAILS TO INFLATE (IS LEAKING). ANCHOR PIN ON HARNESS ON THE TOP LEFT IS SHEARED OFF. REPLACED F/O O2 MASK, OPS CHECKS GOOD NO LEAKS.SDR UALA2013052303588Structure · damagedAFT PIT METAL EXPOSED. COLD WORK METAL BACK INTO SHAPE AND RETAPED. ALL OK.SDR UALA2013052403617Floorbeam · crackedAFT CARGO FLOORBEAM SECTION ABOVE FRAME 56 FOUND CRACKED. REPAIRED.SDR UALA2013052303584Shade · tornCAPTAIN`S SIDE WINDOW SCREEN RIPPED AT HANDLE. MYLAR PULL OUT SUN SHADE DAMAGED CAPT SIDE AFT OF SLIDING WINDOW SHADE, INOPERATIVE NOT USABLE. REPLACED CAPTAIN'S SIDE WINDOW SCREENSDR UALA2013052303587Cover · crackedR2 DOOR SLIDE DECORATIVE COVER HAS A 14 INCH CRACK HORIZONTALLY IN OUTER LAYER 4 INCHES FROM BOTTOM. ALSO, HAS 4 INCH CRACK IN OUTER LAYER EXTENDING 4 INCHES VERTICALLY. VISUAL INSPECTION ACCOMPLISHED, NO ADDITIONAL DAMAGE. BUSTLE IS RIGID. INSTALLED ONE 8SDR UALA2013052303589Oxygen Mask · frayedFIRST OFFICER`S O2 MASK HOSE IS FRAYED. REPLACED O2 MASK IAW AMM, OPS CHECKED GOOD.SDR UALA2013052303590Overheat Loop · shortedTROUBLESHOT LEFT WING LEAK DETECTOR LOOP "B". FOUND SEGMENT 61HF CENTER CONDUCTOR SHORTING TO GROUND. R & R LOOP 61HF IAW, OPS CK GOOD IAW AMM.SDR UALA2013052203551Attach Fitting · damagedINTERCOSTAL ATTACH FITTING, AT FRAME C58 BETWEEN STR 2 AND 3R HAS ONE MISDRILLED HOLE IN FRAME C58. REPAIRED INTERCOSTAL ATTACH FITTING AT FRAME C58 BETWEEN STR 2 & 3R IAW ECRA 5340-01493 & EA130125. REPAIRED CEILING PANEL. INSPECTED REPAIR IAW ECRA 5340-0SDR UALA2013052303580Switch · looseCAPTAIN`S MICROPHONE TRIGGER ON SIDE STICK IS LOOSE. REPLACED IAW AMM AND ACCOMPLISHED OP TEST OF SIDE STICK ASSY, OPS NORMAL.SDR UALA2013052203548Trunnion · wornLEFT INBD FLAP TRUNNION WORN AT AREA D. BLENDED OUT DAMAGED AREA.SDR UALA2013052303585Shroud · crackedRIGHT OVERWING SLIDE CRACKED SHROUD. REPLACED UNIT.SDR UALA2013052203545Wire Harness · faultedFLAPS FAULT DISPLAYED ON UPPER ECAM SCREEN. REPLACED FLAP WIRING AND OPS CHECKED GOOD.SDR UALA2013052303591Actuator · out of adjustRT ELEVATOR DURING GROUND CONTROL CHECK IN FULL UP POSITION SAGGED BUT WAS STILL IN BOX. CREW ALSO REPORTED ENROUTE, RT ELEVATOR NOW BELOW LEVEL BOX. PLANE FLYS NORMAL. COMPLIED WITH DDP. INDICATION PROBLEM ONLY. FOUND RIGHT ELEVATOR IS SAGGING, WHEN GREEN HYSDR UALA2013052303582Floor Panel · delaminatedAFT CARGO FLOOR PANEL 151ZG FOUND DELAMINATED MEASURING ABOUT 17" X 24" EQUALING ABOUT 408 SQUARE INCHES. REMOVED FLOOR PANEL 151ZG AND CLEANED AREA IAW REPLACED AFT FLOOR PANEL 151ZG.SDR UALA2013052303583Floor Panel · delaminatedAFT CARGO FLOOR PANEL 151VG FOUND DELAMINATED MEASURING ABOUT 45" X 24" EQUALING ABOUT 1,080 SQ INCHES. REMOVED AFT CARGO FLOOR PANEL 151VG AND CLEANED AREA IAW MM. INSTALLED AFT CARGO FLOOR PANEL 151VG.SDR UALA2013052303581O-Ring · leakingEVIDENCE OF HYDRAULIC LEAK AT MLG AREA. CLEANED EXTERNAL PANELS & INSIDE RT MLG AREA. FOUND YELLOW HYD MODULE NEAR YELLOW HYD RESERVOIR LEAKING THREE DROPS IAW MINUTE. REPLACED O-RING ON YELLOW SYS HYD PRESSURE TRANSDUCER. OPS & LEAK CHECKED GOOD.SDR UALA2013052003473Seat Back · looseF/O SEATBACK LT SIDE HAS LOOSE CONNECTION. REPLACED F/O SEAT.SDR UALA2013052003472Computer · faultedECAM FLAP FAULT. POST FLIGHT REPORT SHOWS SFCC-1. REPLACE COMPUTER, SLAT FLAP CONTROL IAW AMM.SDR UALA2013052303592Pedal · lack of lubeF/O RUDDER PEDALS FAILED TO SPRING FWD FROM THE EXTENDED POSITION WHEN LEVER PULLED. RUDDER PEDAL ADJUSTMENT IS SERVICEABLE BUT REQUIRES UPGRADE. F/O PEDALS MOVE SLOWER THAN EXPECTED TO THE RETRACTED POSITION. LUBED AND OPS CHECKED OK IAW AMM.SDR UALA2013052003456Seal · chafedL2 DOOR HAS CHAFING OF DOOR SEAL AT UPPER FWD CORNER OF DOOR. REPAIRED CHAFED DOOR SEAL CORNER IAW AMM. PRESSURIZED ACFT IAW MT52-020. NO LEAKS FOUND.SDR UALA2013052003455Valve · faultyCREW REPORTED LOSING CABIN PRESSURE ON DESCENT. FAULTS INDICATE CABIN PRESSURE SAFETY VALVE HAS FAILED OPEN, ECAM 21-31, CABIN PRESSURE LOW DIFFERENTIAL PRESSURE, ECAM 21-31 CABIN PRESSURE SAFETY VALVE, REFER TO TSM 21-31-00-810-808, TSM 21-31-00-810-810. ACSDR UALA2013052303586Oxygen Mask · leakingCAPTAIN`S O2 MASK LEAKS. SWAPPED MASK WITH SECOND OBSERVER'S. MASK DOES NOT LEAK WHILE STOWED. R & R O2 MASK.SDR UALA2013051603381Mount · brokenSEAT 12DEF INBD AFT SEAT MOUNT BROKEN FASTENER. REPLACED AFT MOUNT.SDR UALA2013051403344Contact · damagedEVACUATION ALARM CHIRPS DURING POWER TRANSFERS. REPLACED GEN LINI CONTACT OR 9-XU2, TESTED OK.SDR UALA2013051403356Cover · missingSEAT TRACK COVER MISSING AT ROW 27DEF. INSTALLED NEW SEAT TRACK COVER.SDR UALA2013051403332Rub Strip · unsecureRUBBER STRIP HANGING DOWN AT ROW 22. SECURED STRIP AT ROW 22, OK FOR SERVICE.SDR UALA2013051303322Sensor · faultyWHEEL NW STRG FAULT ECAM. ACCOMPLISHED CHECKLIST. CYCLED A-SKID N-W STRG SW OFF THEN ON. R & R RT NW STEERING FEEDBACK SENSOR IAW MM, OPS CHECKED GOOD.SDR UALA2013051403331Warning Light · false activationALTERNATE LAW DISPLAYED AFTER ENGINE START. ADR1 FAULTED ON CFDS, NO ECAM CAUTIONS OR ADVISORIES , OR FAULT LIGHTS DISPLAYED. REACTIVATED ADIRU NR 2 AND ACCOMPLISHED TEST AMM 34-10-00-040-002 AND SFCC 1&2 AND ADR 1 & 2 TESTS, NO FAULTS. AFS LAND III TEST 2SDR UALA2013051403355Sliding Window · delaminatedF/O SLIDING WINDOW'S VISIBILITY IS AFFECTED BY DEFECTS. DELAMINATING UPPER LEFT. R & R FO'S SLIDING WINDOW PANE IAW AMM, CHECKED GOOD.SDR UALA2013051003268Epsu · faultyEPSU EMERGENCY LIGHT FAULT DISPLAYED. REPLACED EPSU #11-WL PER AMM.SDR UALA2013051403354Power Supply · faultyEPSU EMERGENCY LIGHT FAULT DISPLAYED. REPLACED EPSU 11-WL PER AMM 33-51-28-000-001-A.SDR UALA2013051303308Cylinder · leakingLEFT MAIN GEAR UNLOCK ACTUATOR IS LEAKING. REPLACED LEFT MLG LOCK STAY ACTUATOR CYLINDER IAW AMM, CHECKED OK.SDR UALA2013051003270Battery Pack · failedFORWARD FLIGHT ATTENDANT CIDS PANEL FAILED EMERGENCY LIGHT TEST. REPLACED BATTERY PACK.SDR UALA2013051003269B-Nut · leakingNR 2 ENGINE LEAK CHECK FOUND IDG OIL COOLER RETURN LINE LEAKING. FOUND B-NUT LEAKING, TIGHTENED AND RAN ENGINE NO ACTIVE LEAKS NOTED AT THIS TIME.SDR CALA2013082690764Power Supply · faultyEPSU EMERGENCY LIGHT FAULT DISPLAYED. REPLACED EPSU NR 11-WL IAW AMM 33-51-28-000-001-A.SDR UALA2013050903264Controller · faultedNR 1 PACK OUTLET TEMPERATURE INDICATION INOPERATIVE ON BLEED SYSTEM ECAM PAGES. SWAPPED PACK CONTROLLERS 1 & 2 FOR TROUBLESHOOTING AND PROBLEM MOVED, RETURNED TO ORIGINAL CONFIG REF MM 21-61-34. PACK OPERATION IS NORMAL ONLY INDICATION ISSUE. REPLACED NR 1 SDR UALA2013050803234Tail Cone · crackedNR 1 ENGINE TAIL CONE HAS AN ELEVEN INCH CRACK REPORTED BY RAMP. REPLACED TAIL CONE PER AMM.SDR UALA2013050703186Closeout Panel · crackedRIGHT WING INBD SLAT CLOSING PLATE CRACKED. RPL- :INSTALLED PANEL.SDR UALA2013050703213Radome · damagedDURING BIRD STRIKE INSPECTION FOUND 14 IN DIA. BY 4 IN DEPTH. DENT ON CENTER OF RADOME. REPLACED RADOME IAW AMM 53-15-11-000-001A.SDR UALA2013050703214Paint · damagedBIRD STRIKE ON APPROACH. FOUND DAMAGE TO WEAR ABRASION RESISTANT PAINT ON LEFT WING OTBD FLAP INBD LEADING EDGE NEAR INBD FLAP FAIRING. NO OTHER DAMAGE NOTED.SDR UALA2013050703215Ptu · inoperativeWHILE TROUBLESHOOTING NOISE FOUND PTU INOP. REPLACED PTU REF AMM TASK 29-23-41-000-001-A.SDR UALA2013050703171Gcu · no testEMERGENCY GENERATOR FAILED TEST PER EQ3022. REPLACED GCU. OPS CHECKED GOOD.SDR UALA2013050903239Control Unit · faultedRECORDER SYSTEM FAULT ECAM PRESENT. POST FLT MESSAGES RECORDER SYS FAULT, FDIU, DFDR. REPLACED FDIU.SDR UALA2013050603154Actuator · leakingCREW REPORTS NR 1 ENGINE LEAKING OIL. FBO REPORT LEAK IS HYDRAULIC FLUID FROM THRUST REVERSER INBD LOWER LOCKING ACTUATOR PISTON SEAL AT A RATE OF 8-10 DR OPS PER MIN. REF AMM 78-32-43-200-010-A OK TO CARRY FORWARD.SDR UALA2013050703203Floor Panel · delaminatedAFT CARGO BAY FLOOR PANEL 151VG DELAMINATED 34 INCHES X 17 INCHES. REPLACED AFT FLOOR PANEL IAW AMM 53-42-16 & 53-42-14.SDR UALA2013050703188Transceiver · faultyVHF 1 NOT TRANSMITTING ON 135.22. REPLACED NR 1 VHF.SDR UALA2013050703187Oxygen System · low pressureCREW OXYGEN SYSTEM LOW. SERVICED OXYGEN SYSTEM IAW TASK 35-11-41 AND TASK 12-14-35-600-001-A. NO LEAKS NOTED. BOTTLE SAFTIED AND ACCESS SECURED. OK FOR SERVICE.SDR UALA2013050203070Contactor · defectiveBCL 2 FAULT DISPLAYED ON UPPER ECAM SCREEN. ELEC ECAM MSG CAME ON INTERMITTENTLY. CFDS ATA 243800 CHECK CONTACTOR 6PB2-BCL2 CIRCUIT. ID:BCL2. REFER TO TSM24-38-00-810-813-A, FAILURE OF THE BATTERY 2 CONTACTOR PSBL CAUSES: 6PB2 565-0010, 1PB2 565-0073. REPLSDR UALA2013050203081Floor Panel · delaminatedAFT CARGO PIT FLOOR PANEL 151ZG IS DELAMINATED 24 INCH BY 22 INCH, 7.5 INCH FROM FWD EDGE AND 4 INCH FROM DOOR EDGE. IPC REF 53-42-04-22X ITEM 90, P/N BF530014-103. SRM REF 53-02-00 PG 120. REMOVED AFT CARGO PIT FLOOR PANEL IAW IPC 53-42-04-22X FLOOR PNL 110
Back to IAE V2522-A5