SDR 2008UALA03848Wire Harness · shortedDURING 3SV EMERGENCY LIGHTING SYSTEM TEST EPSU EXT LOAD FWD L DISPLAYED. TEST ON FWD L POWER SUPPLY HAS SAME FAULT. FOUND SHORT IN HARNESS IN DOOR 1L SLIDE PACK. REPLACED DOOR 1L SLIDE PACK, OPS CHECKED NORMAL.
SDR YEN2008F00015Outflow Valve · failedAIR RETURN TO DEPARTURE, AVIONICS EXTRACT VALVE REMAINED FULLY OPEN AFTER TAKEOFF WHEN EXTRACT BUTTON WAS IN NORMAL AND OVRD. REMOVED AND REPLACED VALVE SKIN AIR OUTLET IAW AMM 21-26-53-04, OPS CK NORMAL, OK FOR SERVICE. (K)SDR 2008UALA03825Regulator · leakingOXYGEN LOST PSI INFLIGHT. FOUND LEAKING O2 REGULATOR. REPLACED O2 REGULATOR, SERVICED CREW O2 TO FULL AND LEAK CHECKED, ALL NORMAL.SDR 2008UALA03735Oxygen System · lowCREW O2 PRESSURE IS SHOWING AT 50 PSI. SERVICED BOTTLE TO 1600 PSI AND CHECKED ALL CREW MASKS FOR LEAKS. VERIFIED NO LEAKS AND AFTER 1 HR BOTTLE PRESSURE STILL AT 1600 PSI, ACFT IS OK FOR SERVICE.SDR 2008UALA03629Door · out of rigHEAVY MODERATE AIRFRAME VIBRATION FELT THROUGHOUT A/C. RTFL. NLG DOOR MISMATCH (FAIR). RE-RIGGED NLG DOORS, MISMATCH CORRECTED, NO REPEATS ON SUBSEQUENT FLIGHTS.SDR 2008UALA03634Fire Loop · false activationFIRE LOOP A FAULT DISPLAYED ON UPPER ECAM SCREEN - ENG 2. FDU FAILING INTERMITTENTLY. FIRE LOOP CHECK FOR CHAFING AND SHOOK WIRE BUNDLE AND WAS UNABLE TO DUPLICATE. ACP CHECK OF POST FLT REPORT AND PREVIOUS LEG REPORTS AND NO FAULTS NOTED. REPLACED FDU.SDR 2008UALA03633Battery Pack · faultyWHILE ACCOMPLISHING EMERGENCY LIGHT TEST "BATTERY EPSU RIGHT" DISPLAYED. *S/D* EPSU FAILURE. REPLACED EPSU.SDR 2008UALA03626Windshield · shortedODOR IN COCKPIT, FLIGHT DIVERTED. *S/D* FOUND WHC2 HAD OVERHEATED. REMOVED COVER AND FOUND CHARRED RESISTORS, THIS CAUSED BY AN INTERNAL SHORT WITHIN THE RT (F/O) WINDSHIELD. REPLACED WHC2, AND AND F/O WINDSHIELD, ALL OPS CHECKS NORMAL.SDR 2008UALA03594Unknown · odorFUMES SMELLED IN CABIN & COCKPIT. RTFL. OIL IN RECIRC PATH ACCOMPLISH PACK BURN OUTS AND CHANGED FILTERS (RECIR) CHECK OF GENERATOR FEEDER PINS ALSO REPLACED FILTERS RECIRC. CHECKED CABIN INTERCOM. RUN CREW REPORTED THE ODOR CAME FROM VENTS UNTILL PACK BURSDR 2008UALA03564Beam · corrodedBEAM 150 FOUND CORRODED. ACCOMPLISHED MAJOR REPAIR AT DEN-REMOVED BEAM 150, TRANSFERRED GALLEY MOUNT FITTING AND 5 CLAMP BRACKETS, PICKED UP HOLES FOR SPLICE AT FWD JOINT. COMPLETED BEAM 150 INSTALLATION.SDR 2008UALA03505Beam · corrodedBEAM NR 155 FOUND CORRODED. *S/D* ACCOMPLISHED MAJOR REPAIR AT DEN. REMOVED CORRODED BEAM 155 CONT OF AMIS ITEM 5142016. BEAM 155 BEGAN TRANSFER OF BRACKETS AND DRILLING MOUNTING HOLES. CONT OF AMIS ITEM 5142023 -INSTALLED BEAM 155.SDR 2008UALA03524Connector · looseTWO INCANDESCENT EMERGENCY ESCAPE PATH LIGHTS INOP AT SEATS 20A & 23A. LOOSE CONNECTOR, RE-SET WIRE CONNECTOR ON THE BOX CK OKSDR 2008UALA03591Oxygen System · reads lowCREW OXYGEN SYSTEM LOW. RECORD PRESSURE PRIOR TO SERVICING. *S/D* SERVICED CREW O2 TO FULL, NO LEAKS NOTED AT TIME OF SERVICE.SDR 2008UALA03504Beam · corrodedBEAM NR 175 FOUND CORRODED. *S/D* ACCOMPLISHED MAJOR REPAIR AT DEN. REMOVED BEAM CONT OF AMIS ITEM 5142012. REPLACED WITH NEW BEAM.SDR 2008UALA03506Frame · corrodedRIGHT CORNER LATERAL SHEAR PLATE SUPPORT FRAME FOUND CORRODED ON UPPER AND LWR SURFACES. *S/D* ACCOMPLISHED A MAJOR REPAIR IN DEN. REMOVED SHEAR PLATE SUPPORT FRAME FROM FR69 - FR70 RT SIDE. COMPLETED INSTALL OF SUPPORT FRAME.SDR 2008UALA03507Shear Plate · corrodedRIGHT CORNER LATERAL SHEAR PLATE BETWEEN FR69 AND FR70 FOUND CORRODED. *S/D* ACCOMPLISHED MAJOR REPAIR AT DEN. REMOVED RT SHEAR PLATE. CONT OF AMIS ITEM 5142020 -COMPLETED INSTALL OF RT SHEAR PLATE.SDR 2008UALA03508Beam · corrodedBEAM 145 FOUND CORRODED. *S/D* ACCOMPLISHED A MAJOR REPAIR AT DEN. REMOVED BEAM. PICKED UP HOLES FOR SPLICE PLATES AND INSTALLED TOP PLATES. BEAM BUILT UP, PAINTED AND READY TO INSTALL. INSTALLED BEAM 145.SDR 2008UALA03509Beam · corrodedBEAM 140 FOUND CORRODED. *S/D* ACCOMPLISHED A MAJOR REPAIR AT DEN. REMOVED BEAM CONT OF AMIS ITEM 5142025. INSTALLED FITTINGS ON NEW BEAM CONT OF AMIS ITEM 5142042. BEAM BUILT UP, PAINTED AND INSTALLED.SDR 2008UALA03510Beam · corrodedBEAM 90 FOUND CORRODED. *S/D* ACCOMPLISHED MAJOR REPAIR AT DEN. REMOVED BEAM AND ATTACHING BRACKETS. CONT OF AMIS ITEM 5142024 INSTALLED BRACKETS ON NEW BEAM PICKED UP HOLES FOR AFT SPLICE PLATE. BEAM BUILT UP, PAINTED AND INSTALLED.SDR 2008UALA03490Sill · corrodedDOOR 2L,CREW DOOR SILL BEAM FOUND CORRODED ON UPPER INBOARDD FLANGE AROUND 2EA NUT PLATE HOLES JUST FWD OF FR68. ACCOMPLISHED MAJOR REPAIR AT DEN--REMOVED CORROSION, REF SRM -53-41-14 AND REPLACED NUT PLATES.SDR 2008UALA03491Spacer · corrodedDOOR 2L AFT GIRT BAR FITTING SPACER PLATE FOUND CORRODED. REMOVED CORROSION, PRIMED AND PAINTED.SDR 2008UALA03502Oxygen Bottle · reads lowCOCKPIT OXYGEN BOTTLE LOW. *S/D* SERVICED CREW O2 TO FULL, NO LEAKS NOTED AT TIME OF SERVICE.SDR 2008UALA03511Sill · corrodedDOOR 2R, CREW DOOR SILL BEAM FOUND CORRODED. ACCOMPLISHED MAJOR REPAIR AT DEN. DOOR 2R, CREW DOOR SILL BEAM HAS EXCESSIVE MATERIAL REMOVED ON UPPER INBOARD FLANGE APPROX 4 INCHES FWD OF FR68 BY- 96274-MFG. SILL REPAIR PRIMED PAINTED, AND INSTALLED SRM 53-41SDR 2008UALA03512Beam · corrodedBEAM NR 130 FOUND CORRODED. REMOVED CORROSION.SDR 2008UALA03471Oxygen System · low pressureCREW OXYGEN SYSTEM LOW. RECORD PRESSURE PRIOR TO SERVICING. SERVICED CREW O2 TO FULL, NO LEAKS WERE NOTED AT TIME OF SERVICE.SDR 2008UALA03459Rod End · wornAIRFRAME VIBRATION ON CLIMBOUT. *S/D* LEFT OUTBOARD BLUE ELEVATOR ACT ROD END HAS PLAY. REPLACED LT OUTBOARD ELEV ROD.SDR 2008UALA03417Battery · faultyON EMERGENCY LIGHT TEST, FAULT KEEPS COMING UP EPSU BATT AFT L.SDR 2008UALA03418Oxygen System · low pressureCREW O2 LEVEL LOW.SDR 2008UALA03419Light · missingEMERGENCY EXIT LIGHTING AT 1L IS MISSING - BROKEN. FWD CLOSET DIVIDER AT DOOR 1L MISSING AISLE LENS CAP AND LAMP.SDR 2008UALA03372Floor Panel · corrodedAFT RIGHT FLOOR PANEL (TRIANGULAR) 262CF HAS CORROSION PITS AND MISSING METAL.SDR 2008UALA03420Power Supply · faultyEPSU L FWD FAULT. REPLACED EPSU (10WL). TESTS OKAY.SDR 2008UALA03472Light · inoperativeSEAT 10L EMERGENCY LIGHT INOP. RELAMPED SEAT 10L EMERGENCY LIGHT. OP CHECK GOOD.SDR 2008UALA03373Battery · faultyEPSU BATTERY FWD LEFT DISPLAYED AFTER CIDS EMERGENCY LIGHT TEST. REPLACED BATTERY ON 10WL EPSU. OP CHECKS OKAY.SDR 2008UALA03371Entertain Sys · malfunctionedELECTRICAL BURNING SMELL BACK OF THE AIRCRAFT. PAX ENT SYS DOES NOT TURN ON-OFF.SDR 2008UALA03270Sill · corrodedDOOR 2R SILL PAN NEEDS TO BE REPLACED DUE TO CORROSION.SDR 2008UALA03271Floorbeam · damagedFLOORBEAM 175 NEEDS REPLACEMENT FROM FR68 TO FR70.SDR 2008UALA03327Light · no testAIRCRAFT FAILS 3 SVC EMERGENCY LIGHTS TEST.SDR 2008UALA03293Computer · failedDUAL FMGC FAILURE. RTFL. *S/D* FMGC 2 FAILED-ARRINC INTERLOOP TEST FAILS. FMGC2 INOP UPON ARRIVAL. REPLACED FMGC2. PERFORMED AFS AND LAND TEST PER MM 22-96-00 AND MM 22-97-00. CHECKS GOOD.SDR 2008UALA03299Oxygen Mask · leakingO2 STILL SHOWS SLOW LEAK ABOUT 100 LBS PER 20 MIN. CAPT O2 MASK HAS PIN HOLE LEAK IN HOSE. REPLACED CAPT MASK ASSY, SERVICED CREW O2 TO FULL.SDR 2008UALA03300Oxygen Bottle · underservicedCREW OXYGEN BOTTLE NEEDS SERVICE. SERVICED CREW O2 TO FULL, NO LEAKS NOTED AT TIME.SDR 2008UALA03301Wire Harness · damagedEMERGENCY EEL LIGHTS AT ROWS 15A AND 24A ARE INOP. DAMAGED HARNESS TO ROW 15. REPAIRED DAMAGED HARNESS. ALL LIGHTS TEST GOOD.SDR 2008UALA03246Anti-Ice System · malfunctionedANTI ICE RIGHT WINDSHIELD ECAM WITH STRONG ODOR IN COCKPIT AND CABIN. RTFL.SDR 2008UALA03273Floorbeam · corrodedFLOORBEAMS 145 AND 140 REMOVED FROM FR 64 TO 69 FOR CORROSION.SDR 2008UALA03274Floorbeam · corrodedFLOORBEAM 150 REMOVED FROM FR65 TO FR70, FOR CORROSION.SDR 2008UALA03326Oxygen Mask · faultyF/O OXYGEN MASK WILL NOT PRESS TO TEST. MASK INFLATES AND WORKS BUT TEST FUNCTION INOP.SDR 2008UALA03268Bottle · low pressureCREW REPORT: DOOR 2R DOOR ASSIST BOTTLE PRESSURE LOW.SDR 2008UALA03222Transceiver · intermittentWEATHER RADAR SYSTEM INOP, RTFL. TRANSCEIVER IS INTERMITTENT. REPLACED TRANSCEIVER, OPS CHECK OK.SDR 2008UALA03192Battery · failedLEFT EPSU BATTERY FAILS EMERGENCY LIGHT CHECK. REPLACED EPSU BATTERY.SDR 2008UALA03193Battery · failedRIGHT EPSU BATTERY FAILS EMERGENCY LIGHT CHECK. REPLACED EPSU BATTERY.SDR 2008UALA03179Cover · missingSIDE WALL LIGHT COVER AT RIGHT OVERWING EXIT IS MISSING. REPLACED OVERWING SLIDE ARM SLIDE COVER.