SDR 2007UALA02939Oxygen System · leakingCREW O2 SUPPLY SLOWLY LEAKING. REPLACED O2 REGULATOR. NO REPEATS.SDR 2007UALA02886Bottle · reads lowDOOR 2L DOOR BOTTLE PRESSURE LOW. SERVICED DOOR 2L ASSIST BOTTLE- NO REPEATS SINCE ORIGINAL.SDR 2007UALA02887Extinguisher · reads lowLAV F FIRE EXTINGUISHER SYSTEM, SMOKE. CHECKED DETECTOR-OK, REPLACED LAV FIREXT.SDR 2007UALA02872Skin · buckledFUSELAGE SKIN BUCKLED, RT SIDE AFT OF PIT DOOR BETWEEN FR 59-61 STR 35-39. WHEN RIVETS REMOVED FROM CLIPS, FOUND GAP BETWEEN SKIN AND CLIPS EXCEEDING .031". MAJOR REPAIR ACCOMPLISHED: REPLACED 4 CLIPS AND INSTALLED DOUBLER REPAIR AT FRAME 59 AND STRINGER 35SDR 2007UALA02870Unknown · smokePOSSIBLE SMOKE IN THE CABIN. RECIRC FAN FAILURE- SHOP FINDINGS INDICATE ROUGH BEARINGS, WASHERS AND PACKINGS WORN. (WOULD NOT ROTATE) REPLACED FAN. NO REPEATS SINCE ORIGINAL.SDR 2007UALA02885Structure · dentedDOOR 2R DENTED ON THE BOTTOM. REMOVED DAMAGE AND INSTALLED DOUBLER.SDR 2007UALA02888Lamp · inoperativeDOOR 2R EMERGENCY LIGHT LAMP INOP. LAMP ASSY BELOW EXIT SIGN. REPLACED LIGHT ASSEMBLY.SDR 2007UALA02837Light · no testEMERGENCY AISLE LIGHTS AT SEAT ROWS 9&18 NOT ILLUMINATING ON TEST. DISCONNECTED CONNECTOR UNDER SEAT 9A. SECURED CONNECTOR AND RELAMPED THE LIGHT FIXTURE.SDR 2007UALA02851Power Supply · no testDURING OPERATIONAL TEST FOR THE EMERGENCY POWER SUPPLY UNITS, EPSU EXT LOAD AFT L IS SHOWN ON PTP PANEL (CIDS DIS). ELECTRICAL LEAD FAILURE IN 2L SLIDE PACK. REPLACED 2L SLIDE.SDR 2007UALA02852Sill · corrodedR2 DOOR SILL HAS CORROSION JUST FWD OF FRAME 66. REMOVED AND DRAIN AND FWD GIRT BAR PLATE. FABRICATED 2 REPAIR ANGLES. INSTALLED REPAIR. REINSTALLED DRAIN AND GIRT BAR PLATE.SDR 2007UALA02830Bottle · dischargedDOOR 1R ASSIST BOTTLE HAS ZERO PRESSURE. PRESSURE DISK FAILURE ON DOOR ASSIST BOTTLE. REPLACED THE R1 DOOR BOTTLE PRESSURE DIAPHRAGM AND SERVICED BOTTLE.SDR 2007UALA02832Steering Sys · inoperativePER FLT CREW: NOSE GEAR STEERING INOP. NOSE LANDING GEAR STEERING SERVO CONTROL UNIT INTERNAL GROUND SHORTED. REPLACED NLG SERVO CONTROL UNIT.SDR 2007UALA02836Mask · misinstalledREGUL LO PR DISPLAYED ON DOOR-OXY SYSTEM ECAM PAGE, DOOR-OXY. IMPROPER STOWAGE OF MASK. RESTOWED FIRST OFFICER'S MASK AND RESERVICED CREW O2 SYSTEM.SDR 2007UALA02809Extinguisher · reads lowFIRE EXTINGUISHER PSI IN COCKPIT LOW. LOSS OF PRESSURE IN BOTTLE (FIREXT) REPLACED HALON FIRE EXT IN COCKPIT.SDR 2007UALA02831Unknown · odorF/A REPORTS BURNING PLASTIC ODOR IN AFT GALLEY. INSPECTED OVENS AND COFFEE MAKERS NOTHING. PLASTIC STUCK TO BOTTOM OF AN OVEN TRAY LOADED INTO OVEN AND COOKED, REPLACED OVEN IN AFT GALLEY AS WELL AS CIRCUIT BREAKER PANEL FOR AFT GALLEY OVENS.SDR 2007UALA02762Diaphragm · faultyDOOR 1L SLIDE BOTTLE PRESSURE LOW. LOSS OF PRESSURE DUE TO DIAPHRAGM RUPTURED AND STRIKER PIN BROKEN. REPLACED DIAPHRAGM AND STRIKER PIN AND RECHARGED BOTTLE.SDR 2007UALA02763Battery Pack · faultyEMERGENCY LIGHT TEST FAULTED LEFT EMERGENCY LIGHT. FAULTY BATTERY PACK. REPLACED BATTERY PACK.SDR 2007UALA02761Wire · shortedEMERGENCY LIGHT TEST FAILED EPSU UNIT AFT LEFT. REPAIRED SHORTED WIRES IN EEL.SDR 2007UALA02757Fuel Feed · inoperativeAUTO FUEL FEED SYSTEM INOPERATIVE. FAULTY LOW LEVEL FUEL SENSORS IN RT WING TANK CAUSING LOGIC FAULT IN FQIC. REPLACED TWO LOW LEVEL SENSORS IN RT WING TANK.SDR 2007UALA02764Oxygen Mask · no testCAPTS O2 MASK WILL NOT TEST. FOUND FAULTY MASK & LEAKING HARNESS. REPLACED MASK.
SDR 2007UALA02756Steering Sys · inoperativeLOST NOSE WHEEL STEERING. REPLACED BOTH NWS GEARBOXES, TILLER AND SERVO CONTROL. NO REPEATS SINCE 7/19/07.SDR 2007UALA02738Power Supply · wrong partROWS 1, 2, 3 & 5 HAVE NO EEL LIGHTS. INSTALLED NEW PWR SUPPLY IN FWD POSITION WITH BORROWED PART FROM US AIRWAYS P/N 3214-54-10, S/N 2016, AND OPS CHECK GOOD.SDR 2007UALA02715Pressure Valve · failedAPU WENT INTO AUTO SHUTDOWN AND MESSAGE LP VALVE ON EICAS. APU FUEL LOW PRESSURE VALVE FAILURE. REPLACED APU FUEL LOW PRESSURE VALVE.SDR 2007UALA02732Hydraulic System · leakingFLIGHT DIVERTED DUE TO YELLOW RSVR LOW LEVEL DISPLAYED ON UPPER ECAM. GREEN SYSTEM DROPPING TOO. FOUND PTU SUPPLY CHECK VALVE LEAKING. REPLACED PTU SUPPLY CHECK VALVE.SDR 2007UALA02677Hose · brokenCAPTAIN`S O2 MASK WEB WILL NOT INFLATE INNER HOSE BROKEN. INNER HOSE BROKEN ON CAPTAINS O2 MASK. REPLACED MASK ASSY.SDR 2007UALA02695Skin · dentedEXTERNAL FUSELAGE SKIN DENT 7 INCHES FWD OF FRAME 28 STR 42R. MAJOR REPAIR ACCOMPLISHED: INSTALLED DOUBLER & TRIPLER AT SKIN LAP.SDR 2007UALA02696Stringer · corrodedSTR 42L HAS CORROSION AT FRAME 57. MAJOR REPAIR ACCOMPLISHED: INSTALLED STRINGER REPAIR.SDR 2007UALA03254O-Ring · leakingDURING TEST FLIGHT, NR 1 ENGINE WOULD NOT RELIGHT IN FLIGHT. HUNG START ECAMS. TRIED 3 WINDMILL AND 3 STARTER ASSIST FOUND FUEL LEAK AT FUEL FLOW INDICATOR REPLACED RING AND RAN ENGINE REF 73-31-17 AND JRH 2-40-1.SDR 2008UALA03896Unknown · malfunctionedAUTO FEED FAULT DISPLAYED ON UPPER ECAM SCREEN, 560 LBS IN CTR TANK WHICH WAS PREV EMPTY.SDR UALA2008111303896Warning Message · illuminatedAUTO FEED FAULT DISPLAYED ON UPPER ECAM SCREEN. 560 LBS IN CTR TANK WHICH WAS PREV. EMPTY. OPENED CROSS FEED. NOTICED BOTH ENGS APPEAR TO BE FED OFF LEFT MAIN TANK. WITH CROSS FEED OPEN PUMPS IN ONE TANK CAN OVER COME PUMPS IN OTHER AND CAUSE FUEL SPLIT. THSDR 2007UALA02675Reservoir · unknownCIDS CAUTION LIGHT ON AT THE F-AS PANEL. REPLACED LT OVERWING RESERVOIR AS PRECAUTION. NO CIDS CAUTION LIGHT.SDR 2007UALA02676Oxygen System · malfunctionedTWENTY SIX EA O2 COMPT DOORS DID NOT DEPLOY DURING TEST: FWD FLIGHT ATTENDANT, AFT FLIGHT ATTENDANT, LT SEAT ROWS (6, 9, 11, 13, 15) AND RT SEAT ROWS (1, 2, 3, 6, 9, 11, 13, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25, 26). RESET BREAKERS AND RETESTED. ALL RESDR 2007UALA02636Structure · corrodedFWD PIT HAS NUMEROUS CORRODED FASTENERS FROM FRAME 24B THROUGH FRAME 34 AND BETWEEN STR 38R & 38L. AREA WAS REPAIREDSDR 2007UALA02716Unknown · odorBURNING SMELL IN FWD GALLEY FOR SHORT TIME THEN NOTICED AUDIO INOP WITH C/B-PBS MUSIC LT POPPED.SDR 2007UALA02628Shear Tie · damagedSHEAR TIE AT FR 57 STR 42L IS DAMAGED. MAJOR REPAIR ACCOMPLISHED: REMOVED SHEAR TIE. FABRICATED & INSTALLED NEW SHEAR TIE.SDR 2007UALA02615Door · damagedRIGHT MLG MAIN DOOR & UPPER SIDE DOOR FOUND DAMAGED UPON ARRIVAL. REPLACED RT MLG FIXED AND SECONDARY HINGED FAIRINGS.SDR 2007UALA02618Radar · inoperativeRTFL DUE TO INOPERATIVE WEATHER RADAR. [08-24-07] REPLACED WX RADAR PN 622-5137-601. NO REPEATS SINCE 7/16/07.SDR 2007UALA02635Oxygen Mask · unwanted deployOXYGEN MASKS DEPLOYED 7DEF ON LANDING. BROKEN O2 LATCH AT ROW 7DEF. REPLACED O2 CONTAINER ASSY.SDR 2007UALA02637Electronic Unit · odorBURNING ODOR IN FWD GALLEY FOR SHORT TIME THEN NOTICED AUDIO INOPERATIVE W-CB-PBS MUSIC LT POPPED. REPLACED SEU UNDER SEAT 2ABC, MULTIPLEX BOX AT 3ABC AND CB 23MK. AS PRECAUTIONARY. ODOR WAS INTERMITTMENT AND POSSIBLY UNRELATED TO THE MTX PREFORMED. ODORSDR 2007UALA02642Bottle · lowEMERGENCY SLIDE HAS LOW BOTTLE PRESSURE. REPLACED SLIDE ASSY.SDR 2007UALA02576Attach Angle · crackedLEFTHAND & RIGHTHAND WHEEL WELL AREAS, BELLY FAIRING SUPPORT BRACKET UPPER ATTACH ANGLE IS CRACKED AT FRAME 46. MAJOR REPAIR ACCOMPLISHED: REPLACED ANGLE.SDR 2007UALA02578Skin · dentedLEFT FUSELAGE SKIN IS DENTED 6 INCHES ABOVE AND 18 INCHES AFT OF STATIC PORT, LOCATED WITHIN RVSM AREA. MAJOR REPAIR ACCOMPLISHED: INSTALLED DOUBLER REPAIR.SDR 2007UALA02590Smoke Detector · faultyLAV SMOKE DETECTOR FAULT. LAV SMOKE DETECTOR FAULTY. REPLACED LAV SMOKE DETECTOR. OPS CHECK GOOD.SDR 2007UALA02575Smoke Warning · unknownFLIGHT DIVERTED DUE TO AVIONICS ECAM MSG SHOWING SMOKE.SDR 2007UALA02577Shear Tie · corrodedSHEAR TIE CLIP CORRODED AT FRAME 31 BETWEEN STR 40R - 41R. MAJOR REPAIR ACCOMPLISHED: REMOVED & REPLACED SHEAR TIE.SDR 2007UALA02579Oxygen System · lowCREW OXYGEN LOW. SERVICED O2 SYSTEM, NO LEAKS NOTED.SDR 2007UALA02580Power Supply · faultyEMERGENCY LIGHT SYSTEM FAILS TEST, FAULTS PWR SUPPLY ABOVE DOOR 1L. [07-27-07] REPLACED BATTERY AND UNIT NOW CHECKS GOOD.SDR 2007UALA02537Display · malfunctionedLAV AND CARGO DETECTOR FAULT DISPLAYED ON UPPER ECAM SCREEN, SMOKE. REPLACED SCDU.SDR 2007UALA02554Servo Control · inoperativeNOSE WHEEL STEERING INOPERATIVE. FAULTY NOSE WHEEL STEERING CONTROL SERVO 6GC. REPLACED NOSE WHEEL STEERING SERVO CONTROL.SDR 2007UALA02555Solenoid · failedCREW REPORTS DURING ENG 1 START GOT START FAULT, ENG STALL, EGT OVERLIMIT FAULT, ENG AUTO CRANKED & S- DOWN, NO EGT LIMITS EXCEEDED. FOUND 7TH STAGE "A" CONTROL SOLENOID FAILED. REPLACED 7TH STAGE "A" CONTROL SOLENIOD.