SDR UALA2012010300017Sleeve · malfunctionedLEFT THRUST REVERSER TRANSLATING SLEEVE, FOR THE NR 2 ENGINE, WILL NOT COMPLETELY STOW, CAUSING A REVERSER FAULT. ACCOMPLISHED MANUAL EXTEND AND STOW OF REVERSER. REVERSER DID STOW PROPERLY. ACCOMPLISHED TEST OF REVERSER PER AMM, TESTED GOOD.SDR UALA2012010300018Stator Vane · lack of lubeNR 2 ENG COMPRESSOR VANE MESSAGE ON TAXI OUT. DUAL CHANNEL CFDS FAULT VARIABLE STATOR VANE ACTUATOR HC-EEC2. LOWER LEVEL FAILURE MESSAGE. REF AMM TASK 'INSPECTION OF THE VSV SYSTEM', AND AMM TASK 'LUBRICATION OF THE VSV SYSTEM' LUBE PCN 843-0086. ACCOMPLISSDR UALA2012010300019Stator Vane · malfunctionedNR 2 ENGINE COMPRESSOR VANE MESSAGE AFTER ACCOMPLISHMENT OF CHECK AND LUBE OF THE VSV SYSTEM, ACCOMPLISH AN ACCEL-DECEL CHECK OF THE ENGINE REF JRH 2-40-64. TO ENSURE SYSTEM IS PERFORMING CORRECTLY. ACCOMPLISHED ACCELL RUN PER JRH. ACCELL CHECKED GOOD.SDR UALA2012010300052Buffer · malfunctionedCAPTAIN'S RUDDER PEDALS DO NOT SPRING. RUDDER MOVEMENT AND BRAKE DEFLECTION IS OTHERWISE NORMAL. REPLACED CAPTAIN'S RUDDER PEDAL ADJUSTMENT BUFFER. OP CHECKED OKAY.SDR UALA2012010300053Container · brokenPAX O2 MASKS DEPLOYED 37DEF BY PAX WHO THOUGHT IT WAS UNDEPLOYED TV SCREEN. TAPED UP. INSPECT LATCH AND VERIFY OXYGEN GENERATOR HAS NOT BEEN FIRED. OXYGEN PANEL WILL NOT RE-ENGAGE TO LOCK, TAPED SECURE IN CLOSED POSITION. PLACARD SEATS 37 D, E, AND F 'INOPSDR UALA2011122807136Oxygen Mask · out of positionO2 MASK FELL AT 37DEF.SDR UALA2011123007163Pin · out of adjustO2 MASK FELL AT 37DEF. :UNABLE TO PROPERLY SECURE DOOR IN FULLY CLOSED POSITION. ADJUSTED LATCHING PIN.SDR UALA2012010300047Battery · failedEMERGENCY LIGHT TEST FAILED EPSU 2L AFT. REPLACED 2L EMERGENCY BATTERY. ACCOMPLISHED EMERGENCY LIGHT TEST, TESTED GOOD.SDR UALA2011122807132Lens · missingCOVER MISSING FROM EMER EXIT LIGHTS SEATS 2 AND 3. REPLACED LENS COVERS, ACCOMPLISHED TEST OF CABIN EMERGENCY LIGHTING OPS CHECKED NORMAL.SDR UALA2011122707110Warning System · activatedENG 1 OVSPD FAULT DISPLAYED ON UPPER ECAM ON SHUTDOWN.SDR UALA2011122707111Accumulator · leakingCREW REPORTED INFLIGHT LOSS OF YELLOW SYS HYDRAULIC LOSS. FOUND LEAK NEAR PARKING BRAKE ACCUMULATOR. REMOVED & REPLACED YELLOW SYS BRAKE ACCUMULATOR IAW AMM. OPS AND LEAK CHECKED GOOD.SDR UALA2011122207069Module · faultedLOST NOSE WHEEL STEERING A 2ND TIME. REPLACED BSCU NO HELP, CFDS FAULTS 6GC STEERING ELECTRO HYD MODULE, PARTS ON HAND. WILL RPL TERMINAL WORKING.SDR UALA2011122107041Rotary Actuator · failedFCTL FLAPS FAULT WITH FLP1 SYSTEM JAM CHECK FLP MECH DRIVE AND FLP2 SYSTEM JAM CHECK FLP MECH DRIVE FAILURE MESSAGES. REFERENCE TSM 27-51-00-810-810. RECORD PPU ANGLES PRIOR TO RESETTING ANY CB'S OR MOVING FLAP-SLAT HANDLE. REPLACED NR 2 LT FLAP ROTARY ACTSDR UALA2011122107047Fastener · looseCREW REPORT: FUEL SEEPAGE ON RIGHT WING BY ACCESS PANEL JUST OTBD OF FUELING PANE. SAMC TEXT: FUEL ACCESS PLATE. TORQUED FASTENERS FOR PANEL 640NB, NO LEAKS NOTED.SDR UALA2011122107006Actuator · malfunctionedC-B C14 ON OH PANEL OPENED IN CRUISE. HYD FIRE VALVE Y ENG 2. REPLACED THE RIGHT ENGINE PUMP FIRE VALVE ACTUATOR IAW AMM. ACCOMPLISHED FUNCTIONAL CHECK OF THE HYDRAULIC FIRE SHUT-OFF VALVE IAW AMM, ALL CHECKS GOOD.SDR UALA2011122107034Connector · looseENG 2 FIRE LOOP B FAULT. DEFERRED PER SAMC. :LM INFO: NDS INITIAL TS AND UPDATE IF NOT FIX. THX. SEC: ACP VISUAL INSPECTION OF NR 2 FAN LOOPS. FOUND CON FOR 'B' LOOP LOOSE. CLEANED AND SECURED 'B' LOOP CON. ACP FCU 2 BIT TEST, OPS CHECKED NORMAL.SDR UALA2011122107038Fan · seizedEXTRACT FAN FAULT 18HQ SEIZED. SAMC TEXT: MAINT VERIFIED EXTRACT FAN IS SEIZED. DEF PER MEL, INSTALLED DF STICKER ADJ TO EXTRACT PB. LM INFO: FAN LOB RQSTD FOR MSP-19. RMV'D & RPLC'D AEVC EXTRACT FAN (18HQ) IAW AMM. OPS TEST NORMAL. RPLC'D AEVC 10HQ. BITESDR GTIA20111218314Cylinder · low pressureR1 DOOR ASSIST ACUMM PRESS LOW. SERVICED R1 DOOR ASSIST ACCUMULATOR TO PROPER PRESSURE IAW AMM 52-10-00-614-001.SDR UALA2011122107003Valve · leakingNR 1 ENG PUMP FIRE VALVE LEAKING. LEAK FOUND WHILE TROUBLESHOOTING LM2480. REPLACED NR 1 ENG PUMP FIRE VALVE REF MM. NEW VALVE FAILED OP CHECK DUE TO INDICATION ON LOWER ECAM DID NOT WORK. INDICATION ON VALVE WORKS NORMAL LT. REPLACED VALVE, NO LEAKS NOTESDR UALA2011121906932Skin · dentedACCOMPLISHED VISUAL INSPECTION OF L1 DOOR DENTED AT LOWER DOOR EDGE. DOOR OPENS AND CLOSES WITH NO OBSTRUCTIONS, IS FAIRED AND SITS SQUARELY IN THE OPENING. REPAIRED PER SRM.SDR UALA2011121906982Starter · faultySPARKS DURING NR 2 ENGINE START. REPLACED STARTER, ENGINE RUN-UP CHECKED GOOD.SDR GTIA20111217313Cylinder · low pressureAFT LT PAX DOOR ASSIST BOTTLE LOW ON PRESSURE. SERVICED AFT LT PAX DOOR BOTTLE IAW AMM 52-10-00-614-001-A.SDR UALA2011121906977Battery · dischargedEPSU BAT R MESSAGE FOUND DURING EEL TEST. REPLACED RT OVERWING EPSU BATTERY.SDR UALA2011121506895Light · inoperativeEMERGENCY LIGHT INOP AT SEAT 10 ABC. REMOVED AND REPLACED BULB SUSPECT WIRING ISSUE.SDR UALA2011121906950Proximity Sensor · failedAFTER TAKE OFF MLG DID NOT RETRACT. ECAM DOORS NOT CLOSED & GEAR NOT UPLOCKED ILLUMINATED. RECYCLED OK. REPLACED NLG PROXIMITY SENSOR PER MM. OPERATED NOSE GEAR PER MM, ALL INDICATIONS NORMAL.SDR UALA2011121506886Oxygen Mask · unwanted deployO2 MASKS DEPLOYED AT 20ABC. SECURED O-2 MASKS AT SEAT 20ABC DEF FOR OPS CHECK.SDR UALA2011121506887Mask · unsecureCREW REPORT: ROW 24 O2 PANEL MASKS HANGING DOWN. FOUND RUBBER HOSE SEALING SECTION BETWEEN OXY MASK CONTAINER AND COVE LIGHT DANGLING: SECURED REF MM 25-23-48. UPDATE: RIGHT SIDE ROW 24.SDR UALA2011121406834Ram Air Turb · no testRAT FAILS CHECK, NO GREEN LIGHT. RAM AIR TURBINE ASSY OPS CHECKED GOOD, NO LEAKS.SDR UALA2011121406855Computer · malfunctionedCAPTAIN'S WINDSHIELD HEAT IS INOPERATIVE WITH ECAM MESSAGE. REPLACED WINDOW HEAT COMPUTER PER AMM. OPS CHECKEDD GOOD. MESSAGE CLEARED.SDR UALA2011121206786Light · false indicationDURING TEST OF EMERGENCY EXIT LIGHTS, RECEIVED MESSAGE FOR LT AFT BATTERY. REPEATED TEST SEVERAL TIMES WITH SAME RESULT. ACCOMPLISHED SUCCESSFUL SYSTEM TEST OF EMERGENCY LIGHTS, TEST OK DISPLAYED, NO FAULTS. OBSERVED AFT EMERGENCY LIGHTS ILLUMINATE.SDR UALA2011121206809Unknown · odorODOR IN AREA OF ROWS 33-34DEF. COULD NOT LOCATE SOURCE. CHECKED READING, CEILING, SIDEWALL LIGHTS. OPS CHECKED PACKS. CHECKED LAV WATER HEATERS AND GALLEY EQUIPMENT. CHECKED SEAT DPCU'S FROM ROW 31 AFT FOR VOLUME AND CH FUNCTIONS. NO DEFECTS, FAULTS OR ANSDR UALA2011121206815Microphone · inoperativeFIRST OFFICER'S OXYGEN MASK MICROPHONE INOPERATIVE. REPLACED OBSERVER O2 MASK.SDR UALA2011121206816Fire Warning · false indicationAT GATE HAD A FALSE INDICATION OF A AFT CARGO FIRE. CYCLED BREAKERS. BITE TESTED PER AMM. TESTED OKAY.SDR UALA2011121206817Oxygen Mask · dislodgedO2 MASKS FELL DOWN AT ROW 28. RESTOWED MASKS, NO EVIDENCE OF O2 ACTIVATION AND LATCH OPERATES NORMAL, OK TO CF PER MT 35-003.SDR GTIA20111209307Cylinder · low pressureR1 DOOR LOW AIR PRESSURE. SERVICED R1 DOOR TO PROPER AIR PRESSURE IAW AMM 52-10-00-614-001.SDR UALA2011121206776Feeder Cable · damagedWHILE T-S ENG TO FADEC STATUS MESSAGE. FOUND 5 DAMAGED CABLES AT 6 O'CLOCK POS LEADING TO FMU. REPLACED WIRE HARNESS. ROUTED WIRE BUNDLE TO CORRECT POSITION. CLAMPED AND TIE WRAPPED BUNDLE.SDR UALA2011120806740Epsu · inoperativeACCOMPLISHED SLIDE TEST ON BOTH FWD LT AND RT SLIDES, NO HELP. TEST FAULTS 'EPSU EXT LOAD FWD L' TROUBLESHOT PER TSM, NO HELP. CONTINUE WITH WIRING CHECKS PARA E. REPLACED EPSU 11WL AND BATTERY PER MM, SELF TEST NORMAL. DOORS 1L & 1R SLIDES WERE REMOVED FOSDR UALA2011120806744Seal · missingGREEN SEAL ON RESUSCITATOR MISSING. REPLACED RESUSCITATOR.SDR UALA2011120806749Coupling · leakingCAPT O2 MASK LEAKING AT HOSE ATTACH POINT. REPLACED O2 MASK. OPS NORMAL.SDR UALA2011120706731Turbine Blades · damagedAPU AUTOSHUTDOWN UNDER BOOST CONDITIONS. APU 2ND STAGE TURBINE BLADES HAS SEVERE BLADE TIP DAMAGE. REPLACING APU.SDR UALA2011120806737Turbine Blades · damagedAPU 2ND STAGE TURBINE BLADES HAVE SEVERE BLADE TIP DAMAGE. REPLACED APU.SDR UALA2011120806746Servo Valve · faultedWHEN GEAR WAS LOWERED, RECEIVED AN AUTO BRAKE FAULT ECAM MESSAGE. CLEARED AFTER 2ND EXTENTION. REPLACED NORMAL BRAKING SERVO VALVE, LEAK OP CHECKED NORMAL.SDR UALA2011120806747Door · out of adjustO2 PANEL OPEN AND MASK NOT DEPLOYED AT SEAT 7E. O2 DOOR WILL NOT STAY SHUT, TAPED CLOSED. ADJUSTED AND SECURED PANEL AND TESTED OPERATION OF DOOR PER MM.SDR UALA2011120806752Spring · deformedRT NOSE GEAR DOWN LOCK SAFETY SPRING SHOWS SIGNS OF UNUSUAL DEFORMATION. THERE IS ONLY ONE WRAP HOLDING SPRING ON CLEVIS. REPLACED RT NOSE DOWN LOCK SPRING.SDR UALA2011120606695Control Unit · malfunctionedLAVATORY AND CARGO SMOKE DETECTION FAULT ECAM. SYSTEM RESET, NO HELP. REPLACED SDCU PER MM.SDR UALA2011120606706Toilet Seat Lid · stuckLAVATORY TOILET SEAT COVER DAMAGED AT FWD CAB LT LAVATORY. UNJAMMED TOILET SEAT COVER, OPS CHECKS OKAY.SDR UALA2011120506645Computer · faultyGROUND SPOILER FAULT, FLT DIVERTED. CFDS SHOWS "GND SPLR 3X4 FAULT". NO OTHER FLT CONTROL PAGE FAULTS NOTED. SAMC TEXT: CONTACT TOMC BEFORE SIGN OFF. OPBLM - CREW REPORTS SPOILERS DID NOT WORK ON LANDING: BEFORE NEXT FLT PERFORM TSM 27-60-00-810-806, REPLASDR UALA2011120206621Battery Pack · inoperativeCABIN EMERGENCY LIGHT TEST FAILED. REPLACED BATTERY PACK.SDR UALA2011113006583Light · defectiveEMERGENCY EXIT LIGHT AT LOWER AFT OF 2 LEFT, LENSE WILL NOT STAY ON. REPLACED LIGHT ASSY.SDR UALA2011113006589Rudder · vibrationRUDDER VIBRATION ISSUE.
Back to IAE V2527-A5