Pratt & Whitney Canada PW306B
Service difficulty reports · 257
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE engine_model_key = 'PW306B' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE engine_model_key = 'PW306B' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR CMRR200610015Power Supply · failedTHE NR 2 MFD DISPLAY UNIT REFERENCED HEREIN FAILED DURING GROUND OPERATIONS. THE SUSPECTED SPECIFIC COMPONENT FAILURE IS THE HIGH VOLTAGE POWER SUPPLY UNIT P/N:7018704-902 INSTALLED INSIDE THE CRT DISPLAY UNIT. FURTHER INSPECTION WILL BE REQUIRED TO VERIFY TSDR CMRR200610016Power Supply · failedTHE EICAS DISPLAY UNIT REFERENCED HEREIN FAILED DURING GROUND OPERATIONS. THE SUSPECTED SPECIFIC COMPONENT FAILURE IS THE HIGH VOLTAGE POWER SUPPLY UNIT P/N:7018704-902 INSTALLED INSIDE THE CRT DISPLAY UNIT. FURTHER INSPECTION WILL BE REQUIRED TO VERIFY THE SDR CMRR200610017Power Supply · failedTHE NR 4 MFD DISPLAY UNIT REFERENCED HEREIN FAILED DURING GROUND OPERATIONS. THE SUSPECTED SPECIFIC COMPONENT FAILURE IS THE HIGH VOLTAGE POWER SUPPLY UNIT P/N:7018704-902 INSTALLED INSIDE THE CRT DISPLAY UNIT. FURTHER INSPECTION WILL BE REQUIRED TO VERIFY TSDR CMRR200610018Power Supply · failedTHE NR 5 PFD DISPLAY UNIT REFRENCED HEREIN FAILED DURING GROUND OPERATIONS. THE SUSPECTED SPECIFIC COMPONENT FAILURE IS THE HIGH VOLTAGE POWER SUPPLY UNIT P/N:7018704-902 INSTALLED INSIDE THE CRT DISPLAY UNIT. FURTHER INSPECTION WILL BE REQUIRED TO VERIFY THSDR CMRR200610020Power Supply · failedTHE NR 5 PFD DISPLAY UNIT REFERENCED HEREIN FAILED DURING GROUND OPERATIONS. THE SUSPECTED SPECIFIC COMPONENT FAILURE IS THE HIGH VOLTAGE POWER SUPPLY UNIT P/N:7018704-902 INSTALLED INSIDE THE CRT DISPLAY UNIT. FURTHER INSPECTION WILL BE REQUIRED TO VERIFY TSDR CMRR200610021Power Supply · failedTHE NR 1 PFD DISPLAY UNIT REFERENCED HEREIN FAILED DURING GROUND OPERATIONS. THE SUSPECTED SPECIFIC COMPONENT FAILURE IS THE HIGH VOLTAGE POWER SUPPLY UNIT P/N:7018704-902 INSTALLED INSIDE THE CRT DISPLAY UNIT. FURTHER INSPECTION WILL BE REQUIRED TO VERIFY TSDR CMRR200610023Power Supply · failedTHE NR 4 MFD DISPLAY UNIT REFERENCED HEREIN FAILED DURING GROUND OPERATIONS. THE SUSPECTED SPECIFIC COMPONENT FAILURE IS THE HIGH VOLTAGE POWER SUPPLY UNIT P/N:7018704-902 INSTALLED INSIDE THE CRT DISPLAY UNIT. FURTHER INSPECTION WILL BE REQUIRED TO VERIFY TSDR CMRR200610019Power Supply · failedTHE EICAS DISPLAY UNIT REFERENCED HEREIN FAILED DURING GROUND OPERATIONS. THE SUSPECTED SPECIFIC COMPONENT FAILURE IS THE HIGH VOLTAGE POWER SUPPLY UNIT P/N:7018704-902 INSTALLED INSIDE THE CRT DISPLAY UNIT. FURTHER INSPECTION WILL BE REQUIRED TO VERIFY THE SDR CMRR200610022Power Supply · failedTHE NR 2 MFD DISPLAY UNIT REFERENCED HEREIN FAILED DURING GROUND OPERATIONS. THE SUSPECTED SPECIFIC COMPONENT FAILURE IS THE HIGH VOLTAGE POWER SUPPLY UNIT P/N:7018704-902 INSTALLED INSIDE THE CRT DISPLAY UNIT. FURTHER INSPECTION WILL BE REQUIRED TO VERIFY TSDR CMRR200611025Power Supply · failedTHE EICAS DISPLAY UNIT REFERENCED HEREIN FAILED DURING GROUND OPERATIONS. THE SUSPECTED SPECIFIC COMPONENT FAILURE IS THE HIGH VOLTAGE POWER SUPPLY UNIT P/N:7018704-902 INSTALLED INSIDE THE CRT DISPLAY UNIT. FURTHER INSPECTION WILL BE REQUIRED TO VERIFY THE SDR CMRR200611024Power Supply · failedTHE NR 1 PFD DISPLAY UNIT REFERENCED HEREIN FAILED DURING GROUND OPERATIONS. THE SUSPECTED SPECIFIC COMPONENT FAILURE IS THE HIGH VOLTAGE POWER SUPPLY UNIT P/N:7018704-902 INSTALLED INSIDE THE CRT DISPLAY UNIT. FURTHER INSPECTION WILL BE REQUIRED TO VERIFY TSDR CMRR200611028Power Supply · failedTHE NR 4 MFD DISPLAY UNIT REFERENCED HEREIN FAILED DURING GROUND OPERATIONS. THE SUSPECTED SPECIFIC COMPONENT FAILURE IS THE HIGH VOLTAGE POWER SUPPLY UNIT P/N 7018704-902 INSTALLED INSIDE THE CRT DISPLAY UNIT. FURTHER INSPECTION WILL BE REQUIRED TO VERIFY TSDR CMRR200611027Power Supply · failedTHE NR 5 PFD DISPLAY UNIT REFERENCED HEREIN FAILED DURING GROUND OPERATIONS. THE SUSPECTED SPECIFIC COMPONENT FAILURE IS THE HIGH VOLTAGE POWER SUPPLY UNIT P/N 7018704-902 INSTALLED INSIDE THE CRT DISPLAY UNIT. FURTHER INSPECTION WILL BE REQUIRED TO VERIFY TSDR CMRR200611026Power Supply · failedTHE NR 2 MFD DISPLAY UNIT REFERENCED HEREIN FAILED DURING GROUND OPERATIONS. THE SUSPECTED SPECIFIC COMPONENT FAILURE IS THE HIGH VOLTAGE POWER SUPPLY UNIT P/N 7018704-902 INSTALLED INSIDE THE CRT DISPLAY UNIT. FURTHER INSPECTION WILL BE REQUIRED TO VERIFY TSDR CA061006014Blade · damaged(CAN) ON CLIMB, THE ENGINE EMITTED A LOUD NOISE AND FLAMED OUT. SUBSEQUENT INSPECTION REVEALED HPT1 BLADE DAMAGE. P&WC WILL INVESTIGATE THE EVENT AND WILL ADVISE OF ROOT CAUSE ONCE ESTABLISHED. (TC NR 20061006014)SDR S2YA06007Bracket · brokenIMMEDIATELY AFTER TAKEOFF OF FLIGHT 2343, THE RT GROUND SPOILER DEPLOYED. THE CREW DECLARED AN EMERGENCY AND IMMEDIATELY RETURNED TO DEPARTURE. OUTSTATION MX FOUND THE RT GROUND SPOILER’S ACTUATING BRACKET BROKEN.SDR CA060906020Fan Blade · damaged(CAN) DURING CLIMB THE ENGINE WAS REPORTED TO EMIT A LOUD NOISE ACCOMPANIED BY AN UNCOMMANDED REDUCTION IN POWER. THE ENGINE WAS SHUT DOWN, AN EMERGENCY DECLARED AND THE AIRCRAFT DIVERTED TO POINT OF DEPARTURE. SUBSEQUENT INSPECTION REVEALED METAL DEBRIS IN SDR DXTA200601538Fire Detector · brokenRT ENG FIRE DETECT ILLUMINATED DURING CRUISE FLIGHT. TROUBLESHOT AND CONFIRMED DISCREPANCY. FOUND RT ENGINE ZONE 2 OVERHEAT DETECTOR BROKEN. REMOVED AND REPLACED RT ENGINE ZONE 2 OVERHEAT DETECTOR WITH NEW DETECTOR IAW G-200 M/M CHAP 26-10-10. OPS CHECK GOODSDR DXTA200601533Engine · failedAT 41000 FEET, THE RIGHT ENGINE MADE A VERY LOUD BANG FOLLOWED BY HIGH ITT ON THE RIGHT ENGINE WITH SEVERE VIBRATION. THE RT ENGINE HAS UNCOMMANDED SHUT DOWN. ACCOMPLISHED EMERGENCY LANDING AT CID. ON GROUND FOUND ENGINE HD SEVERE INTERNAL FAILURE. REMOVEDSDR CA060905010Bearing · fractured(CAN) DURING CRUISE THE ENGINE EMITTED A LOUD NOISE ACCOMPANIED BY AN INCREEASE IN INTER-TURBINE TEMPERATURE AND VIBRATIONS AND A CHIP DETECTOR INDICATION. THE ENGINE WAS SHUTDOWN IN FLIGHT AND AN UNSCHEDULED LANDING CARRIED OUT. SUBSEQUENT INSPECTION REVEALSDR S2YA06004Engine · smokeDURING FLIGHT 2290 MKE-YYZ THE FLIGHT CREW REDUCED POWER FOR DESCENT. SHORTLY AFTER THE FLIGHT ATTENDANT REPORTED THE CABIN WAS FILLING WITH AN OIL SMELLING SMOKE. SHORTLY AFTER THAT THE FIRE DETECT SENSOR IN THE LAVATORY WENT OFF. THE CREW DECLARED AN EMERSDR CA060704015Smoke · detected(CAN) ON DESCENT THE CREW REPORTED SMOKE IN THE CABIN AIR. AN EMERGENCY WAS DECLARED AND THE AIRCRAFT LANDED AT POINT OF DESTINATION. P&WC WILL INVESTIGATE THE EVENT AND ADVISE OF ROOT CAUSE ONCE DETERMINED. (TC# 20060704015)SDR CA060601003Packing · misinstalled(CAN) THE ENGINE LOW OIL PRESSURE WARNING ACTIVATED IN CRUISE AND THE ENGINE WAS SHUTDOWN IN FLIGHT. SUBSEQUENT INSPECTION REVEALED OIL LOSS ASSOCIATED WITH A MISINSTALLED OIL CAP O-RING PACKING. (TC NR 20060601003)SDR CMRR200606012Power Supply · failedTHE NR 1 MFD DISPLAY UNIT REFERENCED HEREIN FAILED DURING GROUND OPERATIONS PRIOR TO FLIGHT. THE SUSPECTED SPECIFIC COMPONENT FAILURE IS THE HIGH VOLTAGE POWER SUPPLY UNIT PN: 7018704-902 INSTALLED INSIDE THE CRT DISPLAY UNIT. FURTHER INSPECTION WILL BE REQUIRSDR CMRR200606013Power Supply · failedTHE NR 1 PFD HONEYWELL DISPLAY UNIT REFERENCED HEREIN FAILED DURING GROUND OPERATIONS PRIOR TO FLIGHT. THE SUSPECTED SPECIFIC COMPONENT FAILURE IS THE HIGH VOLTAGE POWER SUPPLY UNIT PN:7018704-902 INSTALLED INSIDE THE CRT DISPLAY UNIT. FURTHER INSPECTION WILSDR CA060531022Seal · damaged(CAN) DURING CRUISE, THE ENGINE LOW OIL PRESSSURE WARNING ACTIVATED. THE ENGINE WAS SHUTDOWN IN FLIGHT AND THE AIRCRAFT DIVERTED TO POINT OF DEPARTURE. SUBSEQUENT INVESTIGATION REVEALED A DAMAGED AND LEAKING ACCESSORY GEARBOX LIP SEAL. (TC NR 20060531022)SDR CMRR200604010Power Supply · failedTHE NR 1 PFD DISPLAY UNIT REFERENCED HERE IN FAILED DURING TAXI OPERATIONS PRIOR TO FLIGHT. THE SUSPECTED SPECIFIC COMPONENT FAILURE IS THE HIGH VOLTAGE POWER SUPPLY UNIT PN:7018704-902 INSTALLED INSIDE THE CRT DISPLAY UNIT. FURTHER INSPECTIONS WILL BE REQUIRESDR CMRR200604011Power Supply · failedTHE NR 1 MFD DISPLAY UNIT REFERENCED HERE IN FAILED DURING TAXI OPERATIONS PRIOR TO FLIGHT. THE SUSPECTED SPECIFIC COMPONENT FAILURE IS THE HIGH VOLTAGE POWER SUPPLY UNIT PN:7018704-902 INSTALLED INSIDE THE CRT DISPLAY UNIT. FURTHER INSPECTIONS WILL BE REQUIRSDR CMRR200603009Power Supply · failedTHE EICAS HONEYWELL DU-870 DISPLAY UNIT REFERENCED HEREIN FAILED DURING TAXI PRIOR TO FERRY. THE SUSPECTED SPECIFIC COMPONENT FAILURE IS THE HIGH VOLTAGE POWER SUPPLY UNIT PN:7018704-902 INSTALLED INSIDE THE CRT DISPLAY UNIT. THIS PARTICULAR DU POSITION WAS PSDR DXTA200601317Engine · warning messageUPON APPLICATION OF TAKEOFF POWER, HAD A MASTER WARNING INDICATION. IT APPEARED TO BE THE BLEED PRESS/TEMP HI MESSAGE. MESSAGE WENT OUT IMMEDIATELY WHEN RETARDING THE THROTTLES. RAN APE FOR 30 MINS. RAN BOTH ENGINES FOR 20 MINS. ADVANCED BOTH ENGINES INDISDR CA060403016Engine · making metal(CAN) DURING CLIMB, THE ENGINE EMITTED A LOUD NOISE FOLLOWED BY AN UNCOMMANDED POWER REDUCTION. THE ENGINE WAS SHUTDOWN IN FLIGHT. SUBSEQUENT INSPECTION REVEALED METAL DEBRIS IN THE ENGINE EXHAUST. MFG WILL INVESTIGATE THE EVENT AND ADVISE OF ROOT CAUSE ONCSDR CMRR200603004Power Supply · overtempTHE NR 1 PFD HONEYWELL DU-870 DISPLAY UNIT REFERENCED HEREIN FAILED DURING GROUND OPERATIONS. THE SUSPECTED SPECIFIC COMPONENT FAILURE IS THE HIGH VOLTAGE POWER SUPPLY P/N:7018704-902 INSTALLED INSIDE THE CRT DISPLAY UNIT. FURTHER INSPECTION WILL BE REQUIREDSDR CMRR200603005Power Supply · overtempTHE NR 2 MFD HONEYWELL DU-870 DISPLAY UNIT REFERENCED HEREIN FAILED DURING GROUND OPERATIONS PRIOR TO FERRY. THE SUSPECTED SPECIFIC COMPONENT FAILURE IS THE HIGH VOLTAGE POWER SUPPLY P/N:7018704-902 INSTALLED INSIDE THE CRT DISPLAY UNIT. FURTHER INSPECTION WSDR CMRR200603006Power Supply · overtempTHE NR 1 MFD HONEYWELL DU-870 DISPLAY UNIT REFERENCED HEREIN FAILED DURING GROUND OPERATIONS PRIOR TO FERRY. THE SUSPECTED SPECIFIC COMPONENT FAILURE IS THE HIGH VOLTAGE POWER SUPPLY P/N:7018704-902 INSTALLED INSIDE THE CRT DISPLAY UNIT. FURTHER INSPECTION WSDR CMRR200603007Power Supply · overtempTHE NR 2 PFD HONEYWELL DU-870 DISPLAY UNIT REFERENCED HEREIN FAILED DURING GROUND OPERATIONS PRIOR TO FERRY. THE SUSPECTED SPECIFIC COMPONENT FAILURE IS THE HIGH VOLTAGE POWER SUPPLY P/N:7018704-902 INSTALLED INSIDE THE CRT DISPLAY UNIT. FURTHER INSPECTION WSDR CMRR200603008Power Supply · overtempTHE EICAS HONEYWELL DU-870 DISPLAY UNIT REFERENCED HEREIN FAILED DURING GROUND OPERATIONS PRIOR TO FERRY. THE SUSPECTED SPECIFIC COMPONENT FAILURE IS THE HIGH VOLTAGE POWER SUPPLY P/N:7018704-902 INSTALLED INSIDE THE CRT DISPLAY UNIT. FURTHER INSPECTION WILLSDR 2006FA0000406Transponder · malfunctionedDEPARTED AND WAS TOLD BY DEPARTURE CONTROL THEY DID NOT HAVE A TARGET ON US. SWITCHED TO SECOND TRANSPONDER WITH SAME RESULT. BOTH TRANSPONDERS APPERARED TO BE IN NORMAL OPS. LANDED AT AND WENT TO A BLACK AIRCRAFT(COMPLETE SHUTDOWN). RESTARTED AND ALL WAS SDR CMRR200602002Power Supply · overtempTHE HONEYWELL DU-870 DISPLAY UNIT REFERENCED HEREIN FAILED JUST PRIOR TO TAKEOFF. THE SUSPECTED SPECIFIC COMPONENT FAILURE IS THE HIGH VOLTAGE POWER SUPPLY P/N:7018704-902 INSTALLED INSIDE THE CRT DISPLAY UNIT. FURTHER INSPECTION WILL BE REQUIRED TO VERIFY TSDR CA060228017Oil System · lowFOLLOWING TAKEOFF ENGINE OIL PRESSURE DECREASED AND THE ENGINE WAS SHUT DOWN IN FLIGHT. THE AIRCAFT DIVERTED FOR AN UNSCHEDULED LANDING. P&WC WILL INVESTIGATE THE INCIDENT AND ADVISE OF ROOT CAUSE ONCE DETERMINED.SDR DXTA200601261Engine · malfunctionedRIGHT ENG EXPERIENCED LOW OIL PRESSURE INFLIGHT. NOTED GRADUAL DECREASE IN OIL PRESSURE. ALL OTHER ENG INDICATIONS WERE NORMAL. NO FLUCTUATIONS ON RT ENG. N1 / N2 WERE NORMAL. THROTTLE WAS BELOW CRUISE DETENT. AS OIL FLUCTUATES BETWEEN 30-60 PSI. ON POST FLIGSDR CMRR200602003Power Supply · overtemp+THE NR 1 PFD DU-870 DISPLAY UNIT REFERENCED HERE IN FAILED DURING GROUND OPERATIONS. THE SUSPECTED SPECIFIC COMPONENT FAILURE IS THE HIGH VOLTAGE POWER SUPPLY PN 7018704-902 INSTALLED INSIDE THE CRT DISPLAY UNIT. FURTHER INSPECTION WILL BE REQUIRED TO VERIFYSDR 2006FA0000194Power Supply · failedHONEYWELL DU-870 EFIS DISPLAY UNIT FAILURE IN FLIGHT. HONEYWELL PN:7014300-902.SDR 2006FA0000195Power Supply · failedHONEYWELL DU-870 EFIS DISPLAY UNIT FAILURE IN FLIGHT. HONEYWELL PN:7014300-902.SDR 2006FA0000196Power Supply · failedHONEYWELL DU-870 EFIS DISPLAY UNIT FAILURE IN FLIGHT. HONEYWELL PN:7014300-902.SDR 2006FA0000197Power Supply · failedHONEYWELL DU-870 EFIS DISPLAY UNIT FAILURE IN FLIGHT. HONEYWELL PN:7014300-902.SDR 2006FA0000199Power Supply · failedDU-870 DISPLAY UNIT REFERENCE FAILED DURING FLIGHT. THE COMPONENT FAILURE IS THE HIGH VOLTAGE POWER SUPPLY.SDR 2006FA0000093Shear Pin · brokenCREW REPORTED DURING GEAR RETRACTION THEY HEARD AND FELT A VIBRATION FROM NOSE GEAR DOOR NOT CLOSING FULLY. DURING INSPECTION THE RIGHT HAND FORWARD GEAR DOOR BREAKING ROD ASSEMBLY WAS FOUND TO HAVE A BROKEN SHEAR PIN.SDR DXTA200601195Bleed Valve · inoperativeTHE HP VALVE FAIL LEFT EICAS MESSAGE DISPLAYED WHEN TROTTLE WAS ADVANCED TO THE TAKEOFF DETENT. THE TAKEOFF WAS ABORTED AND VALVE RESET WAS ATTEMPTED AS PER THE CHECKLIST. THE SAME EICAS MESSAGE DISPLAYED ON THE SECOND ABORTED TAKEOFF. REMOVED AND REPLACED SDR CA060129011Engine · shutdown(CAN) ON ROLL OUT FOLLOWING LANDING, THE PILOT REPORTED AN UNCOMMANDED ENGINE SHUT DOWN. THE ENGINE BLEED VALVES AND BLEED VALVE SOLENOID WERE SUBSEQUENTLY REPLACED. (TC NR 20060129011)SDR CA060129014Engine · odor(CAN) THE ENGINE WAS REPORTED TO EXHIBIT OIL SMELL IN CABIN AIR ACCOMPANIED BY HIGH OIL CONSUMPTION. MFG WILL INVESTIGATE THE EVENT AND ADVISE OF ROOT CAUSE ONCE DETERMINED. (TC NR 20060129014)
Back to Pratt & Whitney Canada PW306B