Pratt & Whitney PW2037
Service difficulty reports · 12,810
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE engine_model_key = 'PW2037' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE engine_model_key = 'PW2037' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR UALA2011050202163Pump · faultyLEFT HYD ELECTICAL PUMP EICAS CAME ON AGAIN WITH LOW PRESSURE LIGHT IN SWITCH. TURNED OFF PER CHECKLIST. REPLACED L-ELEC HYD PUMP PRESSURE SWITCH. ALSO CHECKED ALL DELTA P'S. NONE WERE POPPED PRESSURIZED SYS, ALL PARAMETERS NORMAL. RAN GEAR DOORS UP AND DSDR UALA2011050202150Control Panel · faultyMCP IAS-MACH SWITCH INOP STAYS IN MACH ONLY. REPLACED MCP PER MM, ACP CATIII TEST PER MM. TEST PASSED.SDR UALA2011050202158Starter · faultyNR 2 ENG START, N2 FAILED TO ROTATE. GND SW AND VALVE LIGHT OK. REPLACED STARTER, ROTATED NORMAL, DUCT PRESSURES NORMAL.SDR UALA2011050202108Smoke Detector · inoperativeFWD LAV SMOKE DETECTOR INOPERATIVE. REMOVED AND REPLACED FWD LAV SMOKE DETECTOR PER MM AND OPS CHECKED GOOD.SDR UALA2011050202157Starter · failedAPU WILL NOT START. STARTER WOULD NOT ENGAGE CHECKED FADEC. FOUND REVERSE FLO MESSAGE CLEARED. STILL NO START. APU DID NOT START 4 TIMES, APU NOT CRANKING. REPLACED APU STARTER PER AMM AND REPLACED APU CRANK CONTACTOR PER AMM. DID APU BITE TEST AND RAN APU TSDR UALA2011050202144Control Panel · failedALTITUDE CONTROLLER HAS FROZEN DIGITS IN LANDING ALT WINDOW. REPLACED CABIN PRESSURE SELECTOR PANEL AND PERFORMED OPS CHECKED PER MM.SDR UALA2011050202156Control Valve · failedWEAK APU PRESS FOR ENG START. 10 PSI DURING START. CROSSBLEED START OKAY. VALVE OPENS AND CLOSES NORMAL. LOW DUCT PRESS FROM APU. INOPED PER MEL PROCEDURES. REPLACED SURGE CONTROL VALVE PER MM. OP CHECKED OKAY.SDR UALA2011042902101Hinge Fitting · damagedRIGHT ELEVATOR OTBD HINGE FITTING HAS EVIDENCE OF LIGHTNING STRIKE DAMAGE. REMOVED RT OTBD HINGE FITTING. NEW HINGE ON AOG M1904. REPLACED RT OTBD HINGE FITTING.SDR UALA2011042902102Skin · damagedLIGHTENING BURN HOLE IN SKIN STA 206, 6 INCHES ABOVE STR 27L. REMOVED RIVET, HFEC ACP. NO DEFECT NOTED. PERFORMED SOLID RIVET REPAIR PER SRM.SDR UALA2011042902103Bleed Valve · faultyNR 2 ENG PWR FLUX. REPLACED HIGH STAGE PILOT AND HIGH PRESSURE SHUTOFF VALVE.SDR UALA2011042702052Printer · failedACARS PRINTER FAILED. REPLACED ACARS PRINTER, OPS CHECKED GOOD.SDR UALA2011042702053Filter · out of toleranceCOCKPIT AIR NOISE IS EXCESSIVE. REPLACED RECIR FAN FILTERS PER MM AND EQUIPMENT COOLING FILTER PER MM.SDR UALA2011042702060Radome · crackedRADOME OPENED FOR INSPECTION AFTER BIRD STRIKE. FOUND RADOME CRACKED & DELAMINATED AT UPPER LEFT EDGE (LOOKING AFT) BY BIRD STRIKE, LATCHED 2-EA MIDDLE LOCKS FOR TAXI TO HANGAR. REPLACED RADOME.SDR UALA2011042802071Skin · damagedLOW FREQUENCY EDDY CURRENT HAS INDICATION AT REPAIR DOUBLER ABOVE STRINGER 14L, STA 627, (ABOVE FWD FASTENER IN TOP ROW). REMOVED THE SPLICE STRAP TRIPLER, ACCOMPLISHED HFEC AND LFEC PER NDT 6-51-00-19 AND NO DEFECTS NOTED. FABRICATED AND INSTALLED A NEW TRIPLSDR UALA2011042702038Shaft · defectiveMAIN CABIN DOOR 2L EXTERNAL HANDLE DOES NOT RETRACT. INSTALLED NEW CENTER SHAFT, CLEANED INTERNAL CNTR SHAFT, CLUTCH COLLAR AND INNER SHAFT. OPS CHECKED NORMAL.SDR UALA2011042602034Skin · gougedLEFT SIDE FUSELAGE APPROX STA 610.0 AND WL 206.0. A DENT WITH GOUGE APPROX 3.0 X 2.0 INCHES IN AREA AND .50 DEEP WITH DISPLACED METAL. INITIAL NDT INSP INDICATED SKIN AT 0.063IN WITH A MAX LOST OF 0.010IN AT A READING OF SKIN THICKNESS OF 0.053IN. THIS INSPESDR UALA2011042702050Guard · looseEMERGENCY LIGHT SWITCH COVER ON OVERHEAD PANEL LOOSE. REPLACED GUARD ON EMERGENCY LIGHT SWITCH ON COCKPIT OVERHEAD PANEL IAW MM.SDR UALA2011042501976Fan · noisyRT RECIRC FAN TOO LOUD. PLZ WORK WITH CH1637. ACP COCKPIT GROUND NOISE LEVEL CHECK IAW AMM. VERIFIED BOTH PACKS IN LOW FLOW WITH MCDU. RT RECIRC FAN ON: 108DB. RT RECIRC FAN OFF: 107DB. NOTE - THIS IS ONE OF THE QUIETER 757(S) IN UA FLEET ON GROUND. CLEASDR UALA2011042501987Structure · corrodedCORROSION ON FLOOR JUST INSIDE AFT CARGO COMPARTMENT.SDR UALA2011042501966Girt Bar · damagedL-4 ENTRY DOOR EMERGENCY ESCAPE SLIDE GIRT BAR FITTING END, LEAF SPRING HOLES ELONGATED. REMOVED AND REPLACED L-4 DOOR EMERGENCY ESCAPE SLIDE GIRT BAR PER MM ON NON ROUTINE.SDR UALA2011042501967Fitting · out of adjustMAIN CABIN DOOR 2R ARM AND DISARM LEVER BINDS. ADJUSTED GIRT BAR FLOOR FITTINGS. OPS CHECKED NORMAL.SDR UALA2011042501974Yaw Damper · leakingFLUID DRIPPING FROM ELEV CTRL ACCESS DOOR AND BOTH SIDES OF TAIL CONE. FOUND LEFT YAW DAMPER LEAKING AT 5-10 DROPS PER MINUTE, WITHIN LINE MAXIMUM DISPATCH LIMITS, CARRY FORWARD LEAKAGE LIMITS PERMIT CONTINUED AIRCRAFT OPERATION FOR A MAXIMUM OF 75 FLT HOURS,SDR UALA2011042602024Cover · missingEXPOSED WIRES BEHIND 6F. COSMETIC COVER MISSING AT END OF EMERGENCY LIGHT STRIP. SECURED WITH APPROVED TAPE. INSTALLED NEW COVER OVER END OF EMERGENCY LIGHT STRIP AT SEAT 6F. EMERGENCY LIGHTS OPS CHECKED GOOD.SDR UALA2011042602023Proximity Sensor · faultyDOOR 4L SLIDE GIRT BAR ENGAGED LIGHT DOES NOT GO OUT. SLIDE GIRT BAR MUST BE VERIFIED ENGAGED BY MAINT BEFORE EACH FLIGHT. REPLACED FWD GIRT BAR PROX SENSOR S10216. CHECKED OKAY.SDR UALA2011042501973Structure · dirtyCANNOT ARM DOOR 2R. CLEANED LOWER DOOR AREA DISARM AND ARM DOOR, OPS CHECKED NORMAL.SDR UALA2011042501985Sliding Window · scratchedF/O SLIDING WINDOW IS HEAVILY SCRATCHED IMPAIRING VISION. REPLACED F/O OPENABLE WINDOW PER MM.SDR UALA2011042502002Bottle · low pressureFOUND 1 RT DOOR SLIDE BOTTLE PRESSURE IN RED. REPLACED IR DOOR SLIDE PER MM OPS CHECK NORMAL. 1R MED SLIDE PERFORMED RII INSPECTION OF SLIDE INSTALLATION ASSY. NO DEFECTS FOUND.SDR UALA2011042502003Oxygen Mask · leakingCAPTAIN'S O2 MASK HEADBAND HAS A LEAK. DATA REPLACED CAPTAIN'S MASK PER MM, OPS CHECKED & LEAK CHECKED GOOD.SDR UALA2011042501993Light · inoperativeFLOOR EMERGENCY LIGHTS INOP, ALL FIRST CLASS. REPLACED SHORTED EMERGENCY LIGHT AT MID CABIN FLOOR, OPS CHECKED OKAY.SDR UALA2011042501996Gusset · corrodedCORROSION AT ATTACH GUSSET STA 1681, RBL 33, MAIN CABIN. REMOVED AND REPLACED GUSSET PER SRM.SDR UALA2011042501997Tee Fitting · corrodedCORROSION ON T-FITTING STA 1720, RBL 53 IN THE MAIN CABIN. MAJOR REPAIR ACCOMPLISHED: REMOVED AND REPLACED T-FITTING PER SRM.SDR UALA2011042502014Feeder Cable · defectiveEEL LIGHTING INOP, INTERMITTENT BETWEEN MID LAV AND OVERWING EXIT. REPLACED EEL LIGHT FEEDER CABLE AT OVERWING AREA. OPS TESTED NORMAL.SDR UALA2011042501995Intercostal · corrodedCORROSION ON MAIN CABIN FLOOR INTERCOSTAL AT STA 1650. MAJOR REPAIR ACCOMPLISHED: REMOVED AND REPLACED INTERCOSTAL PER SRM.SDR UALA2011042501998Channel · corrodedHAT CHANNEL ON AFT CABIN PRESSURE DECK CORRODED BETWEEN STA 1688 - 1706 ON RT FLANGE. MAJOR REPAIR ACCOMPLISHED: INSTALLED 4 FREEZE PLUGS IN DISCREPANT LOCATIONS PER PEMCO PWI 809UA178, FABBED AND INSTALLED HAT CHANNEL PER SRM.SDR UALA2011042201956Light · inoperativeEEL LIGHT INOP AT SEATS 14C, 10C AND MID LAV. REPLACED TWO EEL LIGHTS P/N 36262-4, AND ONE STRIP P/N 6025-2. OPS CHECK OKAY.SDR UALA2011042201964Filter · faultyFLT DECK NOISE. DUE TO CHRONIC FLT DECK NOISE ISSUES WITH REPORTS OF BLOCKAGE IN THE CABIN OVERHEAD DISTRIBUTION DUCTS AND THE CABIN SIDEWALL OUTLETS NEED TO ACP THE FOLLOWING: CLEAN THE CABIN OVERHEAD DUCTS. CLEAN THE CABIN SIDEWALL OUTLETS, VALIDATE SIDEWALSDR UALA2011042201960Spacer · missingMAIN CABIN, DOOR 4R DOOR EMERGENCY POWER BOTTLE LINKS HAVE INSUFFICIENT CLEARANCE WITH TRIGGER LEVER ATTACH RIVET, SPACERS MISSING. INSTALLED SPACERS AT UPPER AND LOWER LINKS ON MAIN CABIN, R-4 DOOR EMERGENCY POWER BOTTLE RESERVOIR PER MM ON NON ROUTINE.SDR UALA2011042201961Spacer · missingMAIN CABIN, DOOR 2R DOOR EMERGENCY POWER BOTTLE LINKS ATTACH BOLT TO SPRING CYLINDER SHANKED OUT. *SUPPLEMENTAL DATA UPDATE* GAP BETWEEN LINK AND SPRING CYLINDER. INSTALLED SPACER BETWEEN LOWER LINKAGE AND SPRING CYLINDER AT MAIN CABIN R-2 DOOR EMERGENCY PSDR UALA2011042201962Plate · misalignedMAIN CABIN, DOOR R1 DOOR EMERGENCY POWER BOTTLE SERRATED PLATE NOT ALIGNED WITH CABLE TERMINAL SERRATIONS. ALIGNED MAIN CABIN DOOR R-1 EMERGENCY POWER BOTTLE SERRATED PLATE WITH CABLE TERMINAL SERRATIONS PER MM ON NON ROUTINE.SDR UALA2011042502008Wire Harness · disconnectedAT 16ABC EMERGENCY EXIT LIGHTS DETACHED. FOUND LOOSE CONNECTION IN EMERGENCY LIGHT WIRE HARNESS, RECONNECTED AND ALL OPS CHECKED NORMAL.SDR UALA2011042201955Light · inoperativeEMERGENCY FLOOR PATH LIGHTING HAS SECTION INOP JUST AFT OF ROW 6 TO MID LAV APPROX 27 INCHES INOP. JUST AFT OF ROW 6 TO MID LAV APPROX 27 INCHES INOP. REPLACED EEL LIGHT ASSY, OPS CHK NORMAL.SDR UALA2011042201958Circuit Board · faultyAFT 1 FWD 2 CARGO DET EICAS REMAIN ON AFTER FIRE TEST. NO TIME. AFT CARGO DET 1 WILL BE DEFERRED ON THIS ITEM. SEPARATE WRITE-UP WILL BE MADE FOR FWD CARGO DET 2. REPLACED CIRCUIT BOARD M10 427PER MM.SDR UALA2011042201959Circuit Card · faultyFWD CARGO DET 2 STATUS MSG AFTER FIRE TEST. NO TIME TO T/S. REPLACED CIRCUIT CARD M10427 PER MM. OPS NORMAL.SDR UALA2011042101946Light · faultyBEFORE CABIN CREW MOD STARTED, FOUND EMERGENCY LIGHT STRIP IN FRONT OF THE MID LAV AT STATION 740 IS NOT WORKING. REPAIRED EMERGENCY LIGHT STRIP.SDR UALA2011042201951Floorbeam · corrodedCORROSION AT STA 1640 ON MAIN CABIN FLOORBEAM FROM RBL 54 - RBL 45. MAJOR REPAIR ACCOMPLISHED: REMOVED CORROSION, FABRICATED AND INSTALLED T-CHORD AND 2 ANGLES PER SRM.SDR UALA2011042101928Valve · out of toleranceINTERMITTENT THUMPING NOISE IN COCKPIT WHEN EITHER LEFT OR RIGHT PACK TURNED ON OR OFF. RECIRC OFF DOESN'T HELP. LEFT A-C PACK FLOW CONTROL VALVE, UPPER SUPPORT ROD ASSY FOUND TO BE WORN OUT. SUSPECT CAUSE OF HUMMING SOUND WHEN PACK IS TURNED ON. REPLACED SDR UALA2011042101948Reservoir · low pressureDOOR 1R SLIDE PRESS GAUGE NOT IN GREEN BAND. REPLACED EMERGENCY POWER RESERVOIR PER MM. PRESSURE IS OKAY.SDR UALA2011042001918Structure · crackedFLOORBEAM STA 700 CRACKED AT LBL 45. RPRD PER SRM 53-00-51, RPR. 3 AND UA EVA 80770, ON SMB W-U F6397E.SDR UALA2011042101921Floorbeam · corrodedAFT CABIN FLOORBEAM CORRODED AT STA 1660, RBL 3 TO RBL 5. REPLACED FLOORBEAMS FROM RBL 3 TO RBL 24 PER SRM. ACP ON PEMCO NR 2537N00118, BY MECH AND INSPECTOR.SDR UALA2011042101937Heat Shield · damagedHEAT SHIELD HAS DAMAGE. REPLACED HEAT SHIELD PER MM.
Back to Pratt & Whitney PW2037