Pratt & Whitney PW2037
Service difficulty reports · 12,810
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE engine_model_key = 'PW2037' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE engine_model_key = 'PW2037' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR UALA2009102103286Regulator · leakingOXYGEN PRESSURE REGULATOR FOUND LEAKING. REMOVED AND REPLACED CREW O2 PRESSURE REGULATOR. CHECKS NORMAL AT THIS TIME.SDR UALA2009102003265Gearbox · wornRIGHT T/E FLAP ANGLE TEE GEARBOX RATTLES AND CHATTERS THROUGHOUT RIGHT SIDE, UNABLE TO LOCATE SOURCE OF PROBLEM, LEFT SIDE IS SMOOTH AND QUIET, HYD POWER OR ELECTRIC MAKES NO DIFFERENCE, BUT SOUND IS MUCH LOUDER WITH ELECTRIC MOTOR. SUSPECT WORN OUTPUT GEAR OSDR UALA2009101903256Girt Bar · unsecureDOOR 1R WILL NOT TURN ON SLIDE LIGHT GIRT BAR APPEARS TO BE OUT OF POSITION. SECURED GIRT BAR FWD BAR LOCK ON DOOR 1R. OPS CHECK NORMAL.SDR UALA2009102003271Connector · unsecureEEL LIGHTS INOP ROWS 1 THRU 23 WHEN POWER LOST AT THE GATE (JUST ROW 15 INOP). SECURED LOOSE EEL LIGHT CONNECTOR AT ROW 14. OPS CHECKED ALL EEL LIGHTS IN CABIN. ALL LIGHTS WORKED NORMALLY.SDR UALA2009101903251Lamp · inoperativeEXTERIOR EVAC LIGHT INOP AT DOOR 2LT. RELAMPED EXTERIOR EVAC LIGHT.SDR UALA2009101903252Lamp · inoperativeEXTERIOR EVAC LIGHT INOP AT DOOR 1RT. RELAMPED EXTERIOR EVAC LIGHT.SDR DL75E091640Engine · bird ingestion20 MIN AFTER T/O FROM ABV FLT CREW STATED ENG VIBS ON NR 2 ENG REACHED 1.4 ON CLIMBOUT AND .5 ON NR 1 ENG. FLT CREW STATED THEY ALSO HEARD A THUMP FROM POSSIBLE BIRDSTRIKE. NO OTHER ABNORMAL ENGINE INDICATIONS NOTED. UPON ARRIVAL, AMT FOUND 3 DAMAGED FAN BLASDR DLM88091641Water Heater · overheatedAFT LT LAV SMOKE DETECTOR CHIRPING AT GATE. FOUND AFT LT LAV WATER HEATER OVERHEATING. FWD ITEM TO NEF 381.043 FOR REPLACEMENT-ALSO DETERMINED EXTERNAL START CART CONTRIBUTING FUMES INTO THE CABIN. REMOVED START CART (14138)-NO FURTHER ISSUES.SDR DL75E091639Engine · malfunctionedL ENG SEC CONT-NO OTHER MSGS OR INDICATIONS NOTED. FWD TO MCO/PLAC IAW MEL 73-21-01A. MEL PROCEDURES FOLLOWED CB PULLED AND SECURED. ETOPS CATEGORY 'E': PROBLEMS WITH SYS CRITICAL TO ETOPS.SDR UALA2009101403226Wire Harness · corrodedNR 1 GEN TRIPPED OFF LINE, FLIGHT DIVERTED. FOUND IDG WIRE HARNESS CORROSION AT NR 1 IDG. ONE PIN & SOCKET CORRODED AT FIREWALL CONNECTION. REPLACED TERMINAL BLOCK AT IDG. NR 1 IDG OPS CHECKED GOOD. REPLACED GCU. ALL OPS NORMAL.SDR UALA2009101403232Shutoff Valve · malfunctionedLEFT ENG START NORM, RT ENG START ONLY 5 PSI. FOUND LT ENG PRSOV NOT CLOSE WITH ENG RUNNING AND SWITCH OFF. REPLACED NR 1 PRSOV, STARTED AND RAN NR 1 ENG AND THEN STARTED NR 2 ENG. NORMAL ENG START ON BOTH ENGINES.SDR UALA2009101503234Light · inoperativeEEL PATH LIGHTS INOP ROWS 15, 22, & 25. SECURED CONNECTOR ROW 15, CHECKS OK. ROWS 22 & 25 NEED LIGHT ASSY. REPLACED EEL LIGHTS AT SEAT 22 AND 25.SDR UALA2009101203210Valve · faultyCREW REPORTS APU DUCT PRESS DROPS TO BELOW 10 PSI ON NR 2 ENG START. REPLACED APU SURGE VALVE. OPS CHECK OKAY.SDR UALA2009101203211Pdu · malfunctionedUNABLE TO DROP TRAILING EDGE FLAP ELEC. REMOVED TRAILING EDGE POWER DRIVE UNIT. INSTALLED NEW ALT FLAP DRIVE MOTOR. ACCOMPLISHED FUNCTIONAL TEST WITH NO PROBLEMS.SDR UALA2009101303217Light · unsecureROW 12 AND 13 EMERGENCY FLOOR LIGHTING COMING UP. SECURED LIGHTS.SDR UALA2009101303220O-Ring · leakingLOW BOTTLE. LEAKING FROM GAUGE LOCK NUT. IMPROPER GAUGE SPACING. REMOVED GAUGE AND REPLACED O-RING AND BACK UP O-RINGS AND RE-INSTALLED GAUGE.SDR UALA2009101403231Fuel/Oil Cooler · faultyNR 1 ENG HOC. RAN ENG AT 80 PERCENT NO LEAKS AT DRAINS. REPLACED NR 1 ENG FOC AND BYPASS VALVE. RUNS AND LEAK CHECKS GOOD. RE-SERVICED ENG OIL AND IDG. COWLS SECURED. ACP OP CHECK. NO OIL ADDED, SHOWS 21, TANK FULL. OK TO RETURN TO ETOPS SVC.SDR UALA2009101203189Lug · brokenPWR LOSS EICAS MSGS, RTFL. FOUND TERMINAL LUG BROKEN. REPLACED LUG AND SHRINK TUBING, OPERATION NORMAL.SDR UALA2009101203201Control Panel · malfunctionedELECTRICAL ODOR IN COCKPIT, FLIGHT DIVERTED. CREW REPORTED ELEC ODOR ON CAPT SIDE AROUND THE AREA OF GLARE SHIELD. INSPECTED FWD AND CENTER E&E COMPARTMENTS. FOUND NO BREAKERS OUT OR ANY ELECTRICAL ODOR. REMOVED CAPT VOR CONTROL PANEL, HAD SLIGHT BURN ODORSDR UALA2009101203208Shutoff Valve · malfunctionedLEFT ENG BLEED VALVE STUCK CLOSED. REPLACED PRSOV VALVE, BLEED OPS CHECKS NORMAL.SDR UALA2009101203214Skin · delaminatedNR 2 ENGINE OUTER REVERSER, RT UPPER BIFURCATION PANEL INNER SKIN DELAMINATED 36 BY 7 INCH APPROX 257 INCH. ACCOMPLISHED BIFURCATION REPAIR. REMOVED, RE-INSTALLED AND OP CHECKED REVERSER.SDR UALA2009101203193Light · missingSEAT MOUNTED EMERGENCY ESCAPE LIGHT SEGMENT MISSING. LOWER PART OF AISLE ARMREST OF SEAT 16C. REPLACED EMERGENCY LIGHT SEGMENT AND OPS CHECKS NORMAL.SDR UALA2009101203187Cover · damagedEXIT FLOOR LIGHTING IN AFT OF AIRCRAFT IS COMING UP. REPLACED DAMAGED COVER SECTION. EMERGENCY LIGHTS TEST GOOD.SDR UALA2009101203188Battery · inoperativeF/A REPORTS EMERGENCY FLASHLIGHT INOP AT AFT GALLEY. REPLACED BATTERY.SDR UALA2009101203206Light · inoperativeTWO (2) FOOT STRIP OF EMERGENCY EXIT LIGHTS OUT NEAR ROW 13C. REPLACED A STRIP OF EMERGENCY EXIT LIGHTS NEAR ROW 13C.SDR UALA2009101203207Relay · faultyEICAS MSG R GEN DRIVE DISPLAYED. GEN DRIVE LIGHT ILLUM. GEN DRIVE DISCONNECTED. NOTICED C/B 1 ON FACE OF R GCU WAS OPEN, LIKELY FROM IN FLT. SWAPPED LT & RT ENG GCU'S & RAN RT ENG AGAIN. C/B 1 POPPED AGAIN. BPCU MSGS ARE 28V TO CONTROL SW, GCB-WIRING-GCUSDR UALA2009101203209Oxygen Mask · no testCAPTAIN'S O2 MASK DOES NOT TEST. SWAPPED CAPTAIN'S O2 BOX AND MASK WITH 1ST OBSERVER. FIRST OBSERVER'S SEAT AND ASSOCIATED EQUIPMENT INOP. REPLACED 1ST OBSERVER O2 MASK, TESTS NORMAL.SDR UALA2009101403230Pump · leakingNR 1 ENG HYD PUMP LEAKING FROM SPLIT FLANGE. REPLACED PUMP, ONE MOUNT NUT AND PRESSURE FITTING. LEAK CHECKED OKAY.SDR DL75E091626Throttle · malfunctionedAFTER NORMAL ENG START ON LT ENG, NO RESPONSE TO ENG WHEN THROTTLE ADVANCED FOR TAXI. NO EICAS MSG. UPON RESTART AT THE GATE ALL INDICATIONS NORMAL, ENG RUN AT GATE. ALL INDICATIONS NORMAL. THROTTLE ADVANCE NORMAL, ETOPS CATEGORY 'E': PROBLEMS WITH SYS, CRSDR UALA2009101203180Light · inoperativeEXTERIOR EVAC LIGHT INOP AT DOOR 4LT. RELAMPED EXTERIOR EVAC LIGHT.SDR UALA2009101203204Oxygen Mask · faultyF/O OXYGEN MASK WILL NOT TRANSMIT VOICE. F/O OXYGEN MASK BOX ASSY, OPS GOOD.SDR UALA2009101203205Transmitter · malfunctionedFLAPS FAIL TO MOVE. EICAS MESSAGE 'TE FLAP ASYM' DISPLAYED. REPLACED RIGHT TRAILING EDGE FLAP TRANSMITTER, CHECKS OKAY.SDR UALA2009100903167Light · inoperativeEXTERIOR SLIDE LIGHT AT DOOR 2 LT INOP. RELAMPED LIGHT, OP CHECK GOOD.SDR UALA2009100703148Control Panel · faultyMCDP SHOWS NO LAST FLT FAULTS. NO FAULTS TEST 30. PASSES TEST 04 THAT INCLUDES SELECTING THE HDG SEL SWITCH. REPLACED AFCS MODE CONTROL PANEL AND PERFORMED CAT III CHECK, OP CHECKED OKAY. ACFT OK FOR CAT III SVC.SDR UALA2009100603135Oven · malfunctionedELECTRICAL ODOR IN CABIN, FLIGHT DIVERTED. SUSPECT ODOR FROM GALLEY OVEN. OFFERED EVIDENCE OF BURNING ODOR. REPLACED BOTH MID GALLEY OVENS. OP TEST SATISFACTORY.SDR UALA2009100603142Exciter · defectiveAPU HARD TO START. BITE BOX FAULTS NO LIGHT LRU IGNITER LOST. REPLACED IGNITER, LEAD AND EXCITER. ACCOMPLISHED SEVERAL START WITH NO FAULTS DISPLAYED.SDR UALA2009100703152Gcu · malfunctionedAT ABOUT 500FT' ON FINAL APPROACH L GEN TRIPPED OFF LINE. BITE TEST OF BPCU SHOWED "IDG HIGH RISE TEMP" AND "RPL GCU (D9)". MSGS CALL FOR RPL OF GCU. REPLACED LEFT ENG GCU. IDG OIL LEVEL WAS OK. IDG ELEC CONNECTOR WAS CLEANED. BITE TEST WAS GOOD AND MSGSSDR UALA2009100603133Battery Pack · faultyFLOOR LIGHTING MISSING END CAP DOOR 2L. REPLACED BATTERY PACK M732, GROUND CHECKED NORMAL.SDR UALA2009100503127Impeller · out of toleranceRT AFT PUMP OUT OF TOLERANCE. PERFORMED RESISTANCE CHECK OF REPLACEMENT PUMP. CHECKS OKAY. REPLACED MOTOR IMPELLER.SDR UALA2009100503116Battery Pack · no testMAIN CABIN EMERGENCY LIGHT AT ROW 13L INOP. TROUBLESHOT AND FOUND EMERGENCY LIGHT BATTERY PACK BAD. REPLACED BATTERY PACK AND OPS CHECKS GOOD.SDR UALA2009100503123Idg · malfunctionedL GEN DRIVE LIGHT NOT ON WITH ENGINES OFF. ACP'D ENG RUN WITH VERIFICATION OF GEN DRIVE EICAS MSG, RESET IDG RING. REPLACED NR 1 ENG IDG. OPS CHECK GOOD.SDR UALA2009100503126Eec · malfunctionedCREW REPORTS AFTER ENG START, RT ENG SEC CNTL EICAS MSG DISPLAYED, AND WOULD NOT CLEAR. REPLACED AND TESTED EEC ON NR 2 ENGINE. RAN ENGINE, NO MESSAGES.SDR UALA2009100203093Unknown · odorCREW REPORT: THREE MINUTES PRIOR TO LANDING F/A REPORTED ACRID SMELL IN LAST THREE ROWS, GONE ON LANDING. SAMC TEXT: FA'S REPORTED ACRID RUBBER TYPE SMELL IN LAST 3 ROWS OF COACH, NO SMELL IN AFT GALLEY NOTED. FLT CREW CHECKED AREA AFTER LANDING, NO DEFECTSDR UALA2009100503099Idg · faultyON TAXIOUT, THE LT GEN TRIPPED OFF LINE, DRIVE LITE ILLUMINATED. HAD CREW DISCONNECT IDG AND VERIFIED 0 VOLTS AND FREQS. SERVICED APU OIL PRIOR TO DEPT. SERVICED #1 IDG OIL FOUND FULL. RECONNECTED IDG, BUT STILL HAD DRIVE LIGHTS PRIOR TO ENG RUN FOR DEF. HADSDR UALA2009100503102Light · unsecureEMERGENCY FLOOR LIGHTING LOOSE AT ROW 13. SECURED AND TESTED FLOOR LIGHTING AT ROW 13.SDR UALA2009100103088Power Supply · dischargedMID FWD EMERGENCY LIGHTS OUT. REPLACED POWER SUPPLY AND BATTERY, OPS CHECK NORMAL.SDR UALA2009100103089Engine · fireNR 1 ENG SHUT DOWN DUE TO FLAME IN TAILPIPE. NR 1 ENGINE HAD FLAMES ON START UP, IDG LIGHT & DISCONNECT BY CREW AS WELL AS BLANK INDICATION ON N-1 THEN ALL INDICATIONS. ENGINE STOPPED WITHOUT STARTER SWITCH TURNED TO OFF. REPLACED NR1 ENGINE.SDR UALA2009100203090Lead · damagedK-LAV EMERGENCY LIGHT BAR INOP. SPLICED NEW LEAD-IN. OPS CHECKS GOOD.SDR UALA2009100203092Controller · malfunctionedRT ENG ANALOG N2 MESSAGE ON STATUS PAGE. RT ENG BLD PSI DROPPED TO 0 FOR 5 SEC. NOW NORMAL. REPLACED NR 2 ENG PMA. COMPLETED ENGINE RUN. PER TEST 3 ALL INDICATIONS NORMAL. RT ENG ANALOG N2 MSG DIDN'T RETURN DURING OR AFTER RUN.SDR UALA2009100203094Gcu · malfunctionedEICAS MSG L GEN OFF DISPLAYED AT FL 240. OPERATED NORMAL AFTER RESET. REMOVED AND REPLACED LEFT GENERATOR CONTROL UNIT AND TEST PERFORMED. FOUND GOOD.
Back to Pratt & Whitney PW2037