SDR 2004UALA00774Screw · looseDOOR 2L GIRT BAR LIGHT DOES NOT ILLUMINATE WITH DOOR CLOSED AND ARMED. MOUNTING SCREW FOR FLOOR ATTACH FITTING WAS BACKED OUT AND DID NOT ALLOW GIRT BAR TO ENGAGE FLOOR FITTING. SCREW WAS SECURED AND DOOR ARMS NORMALLY.SDR 2004UALA00798Shear Web · corrodedAFT CABIN SHEAR WEB HAS AREA OF CORROSION AT APPROX BS 1681 THRU 1699 RBL 44 THRU 54. *S/D* MAJOR REPAIR ACCOMPLISHED. FABRICATED AND INSTALLED NEW WEB.SDR 2004UALA00799Floorbeam · corrodedAFT CABIN FLOORBEAM AT BS 1640 IS CORRODED RBL 18 THRU 58. *S/D* MAJOR REPAIR ACCOMPLISHED. FABRICATED NEW T-CAP AND REPAIR STRAPS.SDR 2004UALA00800Web · crackedFLIGHT DECK FLOOR WEB CRACKED ON VERTICAL LEG AT FIRST FASTENER AFT OF STA 199 BULKHEAD ON RT SIDE OF AIRCRAFT. MAJOR REPAIR ACCOMPLISHED. FABRICATED AND INSTALLED NEW WEB.SDR 2004UALA00771Indicator · inoperativeDOOR 3L SLIDE INDICATOR WILL NOT ILLUMINATE. REPLACED LAMP.SDR 2004UALA00738Connector · disconnectedEXIT INDICATOR LIGHTS AT DOORS 4L AND 4R INOPERATIVE. FOUND CONNECTORS D6634 AND D6674 DISCONNECTED FROM INVERTER M10834. RECONNECTED WIRING. SYSTEM OPERATES NORMALLY.SDR ASMF200408009A/C Pack · inoperativeCAPTAIN REPORTED, AFTER ENGINE STARTED (LT ENGINE BLEED) LIGHT TURNED ON AND LT AIR CONDITIONING PACKAGE WAS INOPERATIVE. ENGINE WAS ACCELERATED, BLEED SWITCH WAS RESEATED AND FAIL CONTINUE. ENGINE BLEED SWITCH WAS RESEATED AGAIN AND ENGINE WAS ACCELERATED, (SDR 2004UALA00731Relay · failedCABIN TEMPERATURE STUCK IN FULL HOT. RT PACK TEMP VLV WOULDN'T DRIVE COLD--RPL K56, REF WDM21-51-23 . VALVE WILL NOW DRIVE COLD.SDR 2004UALA00801Floor Support · corrodedCABIN STATION 365, CL TO RBL 15 FLOOR SUPPORT HAS CORROSION. MAJOR REPAIR ACCOMPLISHED. INSTALLED STRAP AND L-ANGLE REPAIR.SDR 2004UALA00802Floorbeam · corrodedAFT CABIN FLOORBEAM AT STA 1661, RBL 54 IS CORRODED. MAJOR REPAIR ACCOMPLISHED. INSTALLED STRAP REPAIR.SDR 2004UALA00803Floorbeam · corrodedMAIN CABIN AT STA 365, RBL 45 TO RBL 60, FLOORBEAM HAS CORROSION. MAJOR REPAIR ACCOMPLISHED. INSTALLED STRAP REPAIR.SDR 2004UALA00736Skin · damagedEXTERNAL FUSELAGE SKIN HAS 2 LIGHTNING STRIKES JUST BELOW FWD CARGO DOOR STA 582 AND 529 AT STR 27R, DEPTH WAS MEASURED TO BE .100. INSTALLED DOUBLER REPAIR.SDR 2004UALA00737Connector · disconnectedEMERGENCY EXIT LIGHT INOP ABOVE SEAT 16ABC. FOUND DISCONNECTED CONNECTOR UNDER OVERHEAD SEALING PANEL. RECONNECTED.SDR 0401505517Floor Support · corrodedDURING H-CHECK FOUND CORROSION ON FLOOR SUPPORT AT BS 377 RBL 45. REPAIRED IAW EA 55-200105.SDR 2004UALA00705Duct · leakingRETURN TO FIELD DUE TO SMOKE IN THE FLIGHT DECK. FOUND A LEAKAGE ON THE BLEED DUCT CLAMP OF THE NR 1 ENGINE INBOARD REVERSER HOLD OPEN ACTUATOR. THE ACTUATOR WAS REPLACED. A PACK BURN-OUT PROCEDURE VERIFIED PROPER FUNCTIONING OF ACTUATOR.SDR 2004UALA00706Warning Light · illuminatedCENTER HYDRAULIC SYSTEM EICAS QUANTITY LIGHT ILLUMINATED. QUANTITY INDICATES .40. EXCESSIVE LEAKING (CENTER SYSTEM HYDRAULIC FLUID) FROM LEFT AILERON INBOARD POWER CONTROL ACTUATOR (PCA). REMOVED AND REPLACED SUBJECT ACTUATOR WITH NEW SERVICEABLE ACTUATOR ANSDR 2004UALA00697Channel · corrodedAFT CABIN PRESS DECK HAT CHANNEL STA 1715 TO 1730 IS CORRODED. FABRICATED & INSTALLED NEW HAT CHANNEL.SDR 2004UALA00698Floorbeam · corrodedCABIN FLOORBEAM AT FS 365 RBL 10 TO RBL 15 CORRODED. FABRICATED & INSTALLED NEW WEB AND ANGLE REPAIRS.SDR 2004UALA00713Skin · delaminatedT/E WEDGE DELAMINATED, SLAT NR 5. REPLACED TRAILING EDGE WEDGE.SDR DL757040692Battery · unserviceableEMERGENCY ESCAPE LIGHTING IN F/C VERY DIM ON TEST. REPLACED BATTERY PACK IN EMERGENCY ESCAPE PATH PWR SUPPLY M9101 IAW AMM. CKS GOOD.SDR ASMF200407028Controller · failedCAPTAIN REPORTED RT AIR CONDITIONING (PACK OFF) LIGHT TURNED ON CONTINUALLY AFTER ENGINE START AND WHEN ENGINE WAS IN IDLE POSITION, PNEUMATIC BLEED OF RT ENGINE WAS SHUTDOWN. PILOT CONTROLLER OF 14TH STAGE WAS REPLACED IAW MM 36-11-19, TEST CORRECT.SDR 2004UALA00678Frame · dentedFRAME AT STA 1540 DENTED ABOVE STR 25R AND 25L. INSTALLED FILLER AND REPAIR J-ANGLE.SDR 2004UALA00679Frame · corrodedAFT FUSELAGE FRAME IS CORRODED AT STA 1681.8 AT STR 17R JUST AFT OF DOOR R-4 DOOR CUT OUT. INSTALLED REPAIR ANGLE FILLER AND STRAP REPAIR.SDR 2004UALA00680Frame · dentedAFT PIT FRAME 1420, DENTED BETWEEN STR 24L AND 25L. INSTALLED J-ANGLE REPAIR.SDR 2004UALA00681Frame · dentedAFT PIT FRAME AT STA 1400 ABOVE STR 25L IS DENTED. INSTALLED J-ANGLE REPAIR.SDR 2004UALA00682Frame · dentedFRAME AT STA 1500 ABOVE STR 25L IS DENTED. INSTALLED J-ANGLE REPAIR.SDR 2004UALA00683Frame · dentedFRAME STATION 1440 ABOVE STR 25L IS DENTED. INSTALLED J-ANGLE REPAIR.SDR 2004UALA00684Frame · dentedFRAME AT STA 1580 ABOVE STR. 25R IS DENTED. INSTALLED J-ANGLE REPAIR.SDR 2004UALA00685Frame · dentedFWD PIT STA. 640 FRAME HAS DENT BETWEEN STR 24R AND 25R. INSTALLED J-ANGLE REPAIR.SDR 2004UALA00686Fitting · gougedNR 1 PYLON AT NAC WL 160, AFT UPR DRAG FITTING IS GOUGED INSIDE BORE. OVERSIZED BORE AND INSTALLED OVERSIZE BUSHING.SDR 2004UALA00783Skin · bird strikeOUTBOARD END L/E SKIN DAMAGED BY BIRD STRIKE. REPLACED SECTION OF L/E SKIN.SDR 2004UALA00677Shear Tie · crackedSHEAR TIE BETWEEN STR 27L AND 28L AT BS 1400 IS CRACKED AND CORRODED. REPLACED SHEAR TIE.SDR 2004UALA00671Floorbeam · corrodedFWD CABIN FLOORBEAM AT BS 324 RBL 62 CORRODED. MAJOR REPAIR ACCOMPLISHED. INSTALLED NEW T-CAP.SDR 2004UALA00672Beam · corrodedR4 DOOR LWR SILL BEAMS CORRODED FROM STA 1640 TO 1681. MAJOR REPAIRS ACCOMPLISHED. INSTALLED NEW SILL BEAMS.SDR 2004UALA00664Frame · dentedFRAME FLANGE DENTED AT BS 1400, STR 26L. MAJOR REPAIR ACCOMPLISHED. INSTALLED NESTED J-ANGLE REPAIR.SDR 2004UALA00665Skin · damagedLT FWD CROWN AT STA 440 IS DAMAGED. MAJOR REPAIR ACCOMPLISHED. INSTALLED DOUBLER AND FILLER REPAIR.SDR 2004UALA00666Floor Support · corrodedDOOR 4R FLOOR SUPPORT INNER CHORD BROKEN OUT AND CORRODED AT BS 1681. MAJOR REPAIR ACCOMPLISHED. FLOOR SUPPORT REPAIR SPLICE.SDR 2004UALA00667Frame · dentedFRAME INNER FLANGE DENTED AT BS 1420, STR 26L. MAJOR REPAIR ACCOMPLISHED. INSTALLED NESTED J-ANGLE REPAIR.SDR 2004UALA00668Crease Beam · corrodedMAIN CABIN STA 760-770, CREASE BEAM AT LBL60 CORRODED. MAJOR REPAIR ACCOMPLISHED. INSTALLED AN EXTRUDED SECTION REPAIR.SDR 2004UALA00656Inverter · inoperativeEMERGENCY EXIT PATH LIGHT INOPERATIVE NEAR OVERWING EXIT. REPLACED INVERTER.SDR 2004UALA00655Intercostal · corrodedCABIN INTERCOSTAL CORRODED AT STA 1638 TO 1640, RBL 12. MAJOR REPAIR ACCOMPLISHED. REMOVED AND REPLACED INTERCOSTAL.SDR ASMF200407015Bleed Valve · failedCAPTAIN REPORTED WHEN STARTING CLIMB FROM FL350 TO FL390 THE RT ENGINE EPR'S INDICATION FLUCTUATE SEVERALLY AND ENGINE PANCAKING AND NOT CLIMBING. AIRCRAFT WAS SENT TO THE HANGAR AND BOROSCOPE INSPECTION AND FIM TESTS WAS PERFORMED TO RT ENGINE IAW MM 72-00-0SDR 2004UALA00651Floorbeam · corrodedCABIN FLOORBEAM IS CORRODED AT STA 1640, RBL 62 TO CREASE BEAM. MAJOR REPAIR ACCOMPLISHED. INSTALLED ANGLE AND STRAP REPAIR.SDR 2004UALA00652Floorbeam · corrodedCABIN FLOORBEAM AT AFT GALLEY STA 1681 LBL 36 CORRODED AROUND SCREW HOLES. MAJOR REPAIR ACCOMPLISHED. CUT OUT DAMAGE AND FABRICATED FLOORBEAM CAP AND INSTALLED.SDR 2004UALA00653Floorbeam · corrodedCABIN FLOORBEAM CORRODED AT STA 365 RBL 42 TO RBL 49. *S/D* MAJOR REPAIR ACCOMPLISHED. DAMAGE CUT OUT AND ANGLE AND STRAP REPAIR ACCOMPLISHED.SDR 2004UALA00654Floorbeam · corrodedCABIN FLOORBEAM CORRODED AT STA 324, RBL 62. MAJOR REPAIR ACCOMPLISHED. DAMAGE WAS CUT OUT ON THE UPPER T-CAP AND REPLACEMENT WAS FABBED AND INSTALLED.SDR 2004UALA00647Crease Beam · corrodedCREASE BEAM BETWEEN BS 960 AND 984 AND RBL 64R TO 70R CORRODED. MAJOR REPAIR ACCOMPLISHED. FABRICATED AND INSTALLED A REPAIR DOUBLER.SDR 2004UALA00648Shear Web · corrodedFLOOR SHEAR WEB FROM BS 1680 TO 1720 AFT OF DOOR 4 RIGHT IS CORRODED. MAJOR REPAIR ACCOMPLISHED. REPAIR DOUBLER INSTALLED.SDR 2004UALA00649Restraint · looseDOOR 1R WILL NOT ARM. SURVIVAL KIT RESTRAINT STRAP WAS DISPLACED FROM ITS CORRECT POSITION AT DOOR LINER AND INTERFERRED WITH GIRT BAR. IT IS POSSIBLE STRAP CAN BE DISLODGED FROM ITS VELCRO ATTACHMENT ON DOOR LINER. CORRECT POSITION OF STRAP IS CHECKED BEFOSDR 2004UALA00734Hydraulic System · leakingLANDED UNDER AMBER ALERT DUE TO LOSS OF HYDRAULIC PRESSURE. RIGHT HAND ALTERNATING CURRENT MOTOR PUMP ASSY FAILED. REPLACED PUMP.
Back to Pratt & Whitney PW2037