SDR UALA2012080704234Skin · dentedDENT ON LT SIDE OF FUSELAGE 6 INCHES AFT AND 6 INCHES BELOW REGISTRATION NUMBER. REMOVED DAMAGED AREA, INSTALLED REPAIR PARTS PER ECRA 5330-04279.SDR UALA2012080704235Skin · crackedLOWER FUSELAGE SKIN, CRACKED AT THE CRITICAL ROW LOCATED BETWEEN BS 500 AND 520, BETWEEN STR 28 AND 29R. REMOVED DOUBLER AND TRIMMED AFFECTED SKIN, NDT CHECKED CUT. INSTALLED REPAIR PARTS PER EC RA 5330-042177.SDR UALA2012081304381Girt Bar · damagedDOOR 2L ARM LIGHT IS OUT AFTER PUSH BACK PRIOR TO TAXI. OPENED DOOR FOR THE OUTSIDE OF ACFT AND THE FORWARD END OF THE GIRT BAR APPEARS TO BE DAMAGED. ACCOMPLISHED ADJUSTMENT OF L2 DOOR IAW AMM, OPS CHECKED GOOD.SDR UALA2012081304383Deck Plate · corrodedCORROSION FOUND ON AFT CABIN PRESSURE DECK FLOOR AT BS 1681, LBL 8 TO RBL 62. REMOVED DAMAGED AREAS, FABRICATED REPAIR PARTS. INSTALLED REPAIR PER ECRA 5330-04259.SDR UALA2012081304384Floorbeam · corrodedBS 1640 FLOORBEAM HAS CORROSION, OUT OF SRM LIMITS IAW SCAL LP 9974488. ACCOMPLISHED UPPER CHORD REPLACEMENT IAW ECRA 5310-05536 REPAIR 5.SDR UALA2012081304385Floorbeam · corrodedSTA 1661 FLOORBEAM HAS CORROSION OUT OF SRM LIMITS IAW SCAL LP 9974514. FLOORBEAM UPPER CHORD REPLACEMENT IN REF TO ECRA 5310-05536 REPAIR 4. ACCOMPLISHED REPAIR, RII INSPECTED.SDR UALA2012081304386Floorbeam · corrodedBS 1600 FLOORBEAM HAS CORROSION OUT OF SRM LIMITS. REPAIRED FLOORBEAM UPPER TEE BETWEEN BL 0 AND RBL 11 IAW ECRA 5310-05556. ACCOMPLISHED REPAIR, RII INSPECTED.SDR UALA2012081304391Floorbeam · damagedBS 1620 FLOORBEAM, AT RBL 44 HAS DAMAGE. REMOVED DAMAGED UPPER TEE, ACCOMPLISHED HFEC. FABRICATED AND INSTALLED REPAIR PARTS PER ECRA 5310-05536.SDR UALA2012081304393Floorbeam · corrodedBS 1681 FLOORBEAM HAS CORROSION OUT OF SRM LIMITSACCOMPLISH RII INSPECTION OF AMIS ITEM 2342115. ACCOMPLISHED FLOORBEAM UPPER TEE REPLACEMENT IN REF TO ECRA 5310-05557.SDR UALA2012081304387Pressure Deck · corrodedBS 1681 AFT PRESSURE DECK WEB HAS CORROSION OUT OF LIMITS. PRESSURE DECK REPAIRED.SDR UALA2012081304388Frame · corrodedAFT CARGO, FRAME BS 1460 HAS CORROSION ON FWD SIDE AT LWR ATTACH POINT FOR THE SHEAR TIE BETWEEN BL 0 AND RBL 4. ACCOMPLISH RII INSPECTION OF AMIS ITEM 2342110. INSTALLED INTERIM REPAIR PER ECRA 5310-05547.SDR UALA2012081304389Frame · corrodedAFT CARGO FRAME HAS CORROSION ON UPPER CAP BS 1480 JUST OB OF RT TRANS PANEL. ACCOMPLISH RII INSPECTION OF AMIS ITEM 2342111. INSTALLED INTERIM RPR PER ECRA 5310-05555.SDR UALA2012081304390Skin · corrodedRIGHT HORIZONTAL STAB SKIN AT HSBL 229 ABOVE THE REAR SPAR HAS CORROSION OUT OF SRM LIMITS. ACCOMPLISH RII INSPECTION OF AMIS ITEM 2342112. INSTALLED INTERIM REPAIR PER ECRA 5510-02241.SDR UALA2012081304392Door Frame · corrodedBS 1681 R4 DOOR FRAME HAS CORROSION OUT OF SRM LIMITS. ACCOMPLISH RII INSPECTION OF AMIS ITEM 2342114. INSTALLED INTERIM REPAIR IN REF TO ECRA 5310-05554.SDR UALA2012080604187Floorbeam · corrodedBS 1640 FLOORBEAM HAS CORROSION OUT OF SRM LIMITS. ACCOMPLISHED UPPER TEE REPLACEMENT IAW ECRA 5310-05536 REPAIR 5.SDR UALA2012080604177Light · inoperativeFOUND AFT EMEGENCY LIGHT NOT WORKING. REPLACED EMERGENCY LIGHT.SDR UALA2012080604181Frame · corrodedBS 1681 FRAME LOWER SECTION HAS CORROSION OUT OF SRM LIMITS IAW SCAL LP 9974494. INSTALLED PERMANENT REPAIR.SDR UALA2012080604183Skin · damagedCARGO DOOR EXTERIOR SKIN HAS TWO DRILL MARKS 24 INCHES FROM BOTTOM, AND 1 INCH FROM TRAILING EDGE. REMOVED DAMAGED AREA, FABRICATED AND INSTALLED REPAIR PARTS PER SRM 52-30-01 REPAIR 4.SDR UALA2012080604184Skin · damagedCARGO DOOR HAS PREVIOUS BLEND AREA ON EXTERIOR SKIN 12 INCHES FROM BOTTOM AND 10 INCHES FROM TRAILING EDGE. REMOVED DAMAGED AREA, FABRICATED AND INSTALLED REPAIR PARTS PER SRM 52-30-01 REPAIR 4.SDR UALA2012080604186Floorbeam · corrodedBS 1681 FLOORBEAM HAS CORROSION OUT OF SRM LIMITS. ACCOMPLISHED FLOORBEAM UPPER TEE REPLACEMENT IAW ECRA 5310-05557.SDR UALA2012080604188Floorbeam · corrodedBS 1661 FLOORBEAM HAS CORROSION OUT OF SRM LIMITS. ACCOMPLISHED FLOORBEAM UPPER TEE REPLACEMENT IAW ECRA 5310-05536 REPAIR 4.SDR UALA2012080604189Floorbeam · corrodedBS 1600 FLOORBEAM HAS CORROSION OUT OF SRM LIMITS. ACCOMPLISHED FLOORBEAM UPPER TEE REPAIR BETWEEN BL 0 AND RBL 11 IAW ECRA 5310-05556.SDR UALA2012080604190Pressure Panel · corrodedBS 1681 RBL 33 AFT PRESSURE DECK WEB HAS CORROSION OUT OF SRM LIMITS. ACCOMPLISHED PRESSURE DECK REPAIR IAW ECRA 5330-04259.SDR UALA2012080604221Wire · crimpedNR 1 AUDIO SELECTOR PANEL LIGHTING FAULTY (VOLUME CONTROL, ETC). (01=CAPT, 02=FO, 03=OBS). SUPPLEMENTAL DATA UPDATE, TROUBLESHOT SYSTEM. FOUND FAULTY CRIMP ON WIRE NR W2297-001-16, RETERMINATED WIRE AT TB159. CAPTAIN AUDIO SELECT PANEL TESTED OK.SDR UALA2012080704249Unknown · odorINTERMITTENT STRONG ELECTRICAL ODOR EMANATING FROM AREA FROM 2L TO MID CABIN. FLIGHT ATTENDANT DETECTED AN ELECTRICAL OR RUBBER ODOR, NO SMOKE, LOCALIZED AT DOOR 2L AND MID LAV, ODOR INTERMITTENT LIGHTS WERE OFF. INSPECTED LAVATORY AND SIDEWALL BALLAST AND GSDR UALA2012081304461Door Frame · corrodedBS 1681 R4 DOOR FRAME HAS CORROSION OUT OF SRM LIMITS. INSTALLED INTERIM REPAIR IN REF TO ECRA 5310-05554.SDR UALA2012080704258Module · faultedSTABILIZER TRIM EICAS ILLUMINATED ON SHORT FINAL WENT OUT ON TAXI IN WITH CENTER STABILIZER SWITCH IN CUTOUT. MOVING THE STABILIZER USING THE RIGHT HYDRAULIC SYSTEM STABILIZER TRIM LIGHT ILLUMINATES. PERFORMED FIM 27-09-00 FIG 103. NO MSG PER SHEET 8 BLOCK SDR UALA2012080604159Relay · malfunctionedSTATUS MESSAGE POWER TRANSFEER UNIT. TROUBLESHOT PER FIM 29-22-00 FIG 1 04. REPLACED RELAY RAN BOTH ENGINES AND NO EICAS MESSAGE.SDR UALA2012080604168Idg · failedLEFT GENERATOR DRIVE DISCREPANCY, RETURNED TO FIELD. LEFT ENGINE FUEL-OIL HEAT EXCHANGER REMOVED PER MM THRU PAGE 410 PARA 8. INSTALLED LT FUEL-OIL HEAT EXCHANGER PER MM. CHECKED DPI AND FILTER FOUND DPI NOT EXTENDED OR CONTAMINATION IN FILTER OR OIL. INSTSDR UALA2012080604171Frame · corrodedAFT CARGO LWR LOBE FRAME STA 1460 HAS CORROSION ON FWD SIDE AT LWR ATTACH POINT FOR THE SHEAR CLIP BTWN BL- 0 AND RBL-4. INSTALLED PERMANENT REPAIR.SDR UALA2012080604173Frame · corrodedAFT CARGO FRAME HAS CORROSION ON UPPER CAP STA 1480 JUST OUTBOARD OF RT TRANS PANEL. INSTALLED PERMANENT REPAIR.SDR UALA2012080604175Skin · corrodedRT HORIZONTAL STAB SKIN AT HSBL 229 ABOVE THE REAR SPAR HAS CORROSION OUT OF SRM LIMITS. ACCOMPLISHED A PERMANENT REPAIR.SDR UALA2012080704243Module · faultyCREW REPORTS STAB TRIM EICAS MSG. REPLACED RT STAB TRIM POSITION MODULE PER MM, OP CHECKED OK. PERFORMED MCDP GND TEST 65 STAB TRIM OP CHECKED OK. PERFORMED MCDP GND TEST 30 PER MM 22-00-03 FIG 117, OP CHECKED OKAY.SDR UALA2012080304150Detector · faultedFWD CARGO DET 1 AND 2 BOTH LOOPS SHOW FAULT, CYC BREAKERS. NO MESSAGE .SDR UALA2012080804313Circuit Card · wrong partGEN DRIVE DISC LIGHTS ON OVERHEAD PANEL ARE ILLUMINATED DIMLY, BUT GENS WORK NORMALLY. FOUND WRONG CIRCUIT CARDS INSTALLED ON DRIVE LIGHT SWITCHES (S1&S2). INSTALLED CORRECT (LED) CIRCUIT CARDS. DIM LIGHT WITH ENGINES RUNNING PROBLEM IS CORRECTED.SDR UALA2012080604220Circuit Card · wrong partGENERATOR DRIVE DISCONNECT LIGHTS ON OVERHEAD PANEL ARE ILLUMINATED DIMLY, BUT GENS WORK NORMALLY. FOUND WRONG CIRCUIT CARDS INSTALLED ON DRIVE LIGHT SWITCHES (S1 AND S2). INSTALLED CORRECT (LED) CIRCUIT CARDS. DIM LIGHT WITH ENGINES RUNNING PROBLEM IS CORRSDR UALA2012080304151Fan · odorSMOKE IN FWD GALLEY OVEN, FLIGHT DIVERTED. FOUND OVEN NR 107 UPPER FAN WITH BURNT ELECTRICAL SMELL. REMOVED OVEN AND CHECKED PINS FOR ANY DAMAGE, FOUND NONE. CHECKED GALLEY CIRCUIT BREAKERS IN COCKPIT AND IN E/E COMPARTMENT, NONE WERE TRIPPED. OPERATED REMSDR UALA2012080604214Liner · damagedNR 2 ENGINE FAN SOUND ABSORBING LINER HAS A HOLE IN IT AT THE 4 O'CLOCK POSITION IT IS .750 INCH BY .750 INCH, THE HOLE IS ALSO .825 INCH DEEP. SUPPLEMENTAL DATA UPDATE, LARGE AMOUNT OF SOFT AND HARD POTTING MATERIAL IN HOLE FROM EARLIER ATTEMPS TO REPAIR. WSDR UALA2012080604213Generator · faultedLEFT GENERATOR OFF CHRONIC PROBLEM RESET OKAYSDR UALA2012080604215Skin · delaminatedNR 5 SLAT TRAILING EDGE WEDGE HAS DELAMINATION ON INBOARD AFT END, SIZE IS 8 INCH-8 INCH. REMOVED NR 5 SLAT P/N 114N30 02-79A SN A1-0291. WAITING ON INSPECTION OF TRACKS AND AREA CLEARANCE TO INSTALL NEW FLAP. INSTALLED SLAT. COMPLETED INSTALL AND RIG PESDR UALA2012080104129Light · looseEMERGENCY LIGHT STRIP IN FRONT OF LAV AT DOOR 2L IS PULLED LOOSE. CHECKED EMERGENCY ESCAPE LIGHTING IN FRONT OF MID LAV DOOR. FOUND STRIP SECURE AND OPERATIONAL.SDR UALA2012073104123Floor Panel · puncturedTWO PUNCTURES IN AFT CARGO BAY FLOOR PANEL AT STA 1402. FIRST HOLE 4X5 AND SECOND HOLE 2.5 X .5. REPAIRED DAMAGED FLOOR PANEL PER MM 53-30-98 REPAIR 4.DSDR UALA2012073004116Exciter · inoperativeAPU HAD SHUTDOWN, FAULT LIGHT ILLUMINATED AND EICAS MESSAGE. APU FAULT DISPLAYED. THREE FAILED START ATTEMPTS ALL HUNG AT 25 PCT RPM BEFORE AUTO ABORT. FOUND NO SPARK ON APU ENGINE START, REPLACED EXCITER BOX AND LEAD, OPS CHECKED GOOD.SDR UALA2012073004108Light · faultyR1 DOOR SLIDE LIGHT DOES NOT ILLUMINATE WHEN DOOR IS ARMED. REPLACED LIGHT ASSY. SYSTEM OPS, CHECKED NORMAL.SDR UALA2012080804265Light · looseEMERGENCY LIGHT LOOSE SEATS 11C AND 12C. SECURED LOOSE LIGHT.SDR UALA2012080804266Light · brokenEMERGENCY LIGHTS INOPERATIVE FROM ROW 3 TO DOOR 2L. REPAIRED BROKEN EMERGENCY LIGHT AT DOOR 2L TO ROW 3. OPS CHECKED NORMAL.SDR UALA2012080804267Control Head · failedACARS CONTROL HEAD ON PEDESTAL FAILS TO DIM BRIGHT CORRECTLY. REPLACED CONTROL HEAD PER AMM. OPS CHECKED GOOD.SDR UALA2012080804270Cover · missingAT DEPARTURE, CAPTAIN REPORTED SLIDING WINDOW UNDERNEATH THE LOCK HANDLE TRACK COVER MISSING. REPLACED MISSING LOCK HANDLE TRACK COVER.SDR UALA2012080804268Seal · leakingPRESSURE LEAK R10DOOR FROM TOP L AFT TO TOP MID DOOR. SECURED SEAL AND PRESSURIZE AIRCRAFT. FOUND NO LEAK AT 4.TO 5.SDR UALA2012073004111Frame · damagedAFT CARGO COMPARTMENT LOWER BILGE STRUCTURE, FWD FACE OF FRAME EXFOLIATED BS 1400, RBL 0-RBL 24. ACCOMPLISHED INTERIM REPAIR PER TIMCO REO-G15110 REV C AND ECRA 5362-01022. REPAIR BS 1400 FRAME WEB, BTWN S27R-S30 MUST RECEIVE NEW ACCOMPLISHED ON NR 40369. P
Back to Pratt & Whitney PW2037