Pratt & Whitney PW2037
Service difficulty reports · 12,810
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE engine_model_key = 'PW2037' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE engine_model_key = 'PW2037' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR UALA2012061103210Control Panel · malfunctioned1ST OBSERVER S O2 MASK MICROPHONE INOPERATIVE. SWAPPED CAPTAIN`S AND 1ST OBSV AUDIO SELECT PANEL, O2 MASK MICROPHONE OPS NORMAL. REPLACED 1ST OBSV AUDIO SELECT PANEL, O2 MASK MICROPHONE SYS NORMAL.SDR UALA2012061103199Girt Bar · disengagedDOOR 4R ARMED WITH NO SLIDE LIGHT. FOUND FWD SIDE OF GIRT BAR NOT ENGAGED. SECURED GIRT SLIDERS AND ACCOMPLISHED, OPS CHECK PER MM 52-22-96. SLIDE OPS NORMAL.SDR UALA2012061103229Unknown · unknownFUEL TRANSFER FROM RT WING TO CENTER TANK AT CRUISE, WENT FROM 14.5-0-14.5 AT TOP OF CLIMB. ACCOMPLISHED BITE OF FQIS. NO FAULTS FOUND. SELF TEST GOOD. ALL THREE TANKS DRIPPED AND FOUND WITHIN TOLERANCE PER MM.SDR UALA2012061103194Pitot Line · chafedMAIN CABIN, STA 760 RT SIDE ABOVE THE G2A GALLEY, THE NR 1 PITOT PRESSURE LINE IS CHAFED THROUGH. REMOVED PITOT LINE ABOVE G2A GALLEY RT SIDE PER MM 20-10-09. REPAIRED PITOT LINE USING 2 SLEEVES P/N BACS13AP6, 1 P/N MS21921-6, AND 1 IAW MM 20-10-09. REPAIRESDR UALA2012061103195Carriage · looseLEFT TRAILING EDGE OUTBOARD FLAP, OUTBOARD CARRIAGE, FWD MOUNT ATTACH FASTENERS MISSING AND LOOSE AT FLAP FWD SPAR. REMOVED LT OUTBOARD TRAILING EDGE FLAP PER MM 27-51-14. REMOVED CARRIAGE FWD MOUNT ATTACH FITTING. FOUND NEGLIGIBLE WEAR ON FLAP FRONT SPAR WSDR UALA2012061103196Floorbeam · corrodedMAIN CABIN FLOORBEAM CORRODED AT BS 365.25, BL 0 TO RBL 63. TEE FITITNG FOUND OUT OF LIMITS. REMOVED DAMAGED SECTION OF TEE AND FABRICATED A NEW TEE, REPAIR ANGLES AND STRAPS AND INSTALLED PER SRM 53-00-51.SDR UALA2012061103207Lamp · inoperativeEMERGENCY LIGHTS FROM ROW 8 TO 14 ARE INOPERATIVE. RELAMPED IAW AMM 33-51-11. OPS CHECKED GOOD.SDR UALA2012060803130Ground Wire · brokenCONTROL CABIN TEMP FAULTY, FLIGHT DIVERTED. REPLACED LEFT PACK TEMP CONTROL VALVE PER AMM. RAN BOTH ENGINES WITH ENG BLEED AIR OPS CHECKED NORMAL. RAN BOTH PACKS AND NOTED LEFT PACK TEMPS HIGH. TRIM AIR SYSTEM OP CHECKS NORMAL. SWAPPED PACK CONTROLLERS SDR UALA2012060803140Indicator · trippedSLOWING FOR APPROACH, RECEIVED TRAILING EDGE FLAP DISAGREE EICAS. SUPPLEMENTAL DATA UPDATE, FLAPS LOCKED AT 21 WHEN FLAP. HANDLE WAS MOVED TO 25, RAN QRH CHECKLIST TO SUCCESS. ACCOMPLISHED INSPECTION OF FLAP OVER LOAD INDICATORS, FOUND NR 1 INDICATOR POPPSDR UALA2012060803134Floorbeam · corrodedMAIN DECK FLOORBEAM UPPER CAP CORRODED, BS 1640, BL-0 TO RBL 5. MAJOR REPAIR ACCOMPLISHED: REMOVED DAMAGE SPLICED IN NEW SECTION OF UPPER CAP PER SRM.SDR UALA2012060803159Counterbalance · defectiveMAIN ENTRY DOOR 4R BODY TORQUE TUBE COUNTER BALANCE MAKES POPPING NOISE DURING OPENING & CLOSING. REPLACED COUNTER BALANCE.SDR UALA2012060803160Shim · migratedRIGHT MLG FWD TRUNNION SUPPORT FITTING MIGRATED SHIM AT AFT OUTBOARD END. REPLACED MIGRATED SHIM WITH SOLID SHIM PER ECRA 5750-04450. NON-ROUTINE 32697.SDR UALA2012060803161Shim · migratedRIGHT WING RETRACT ACTUATOR SUPPORT, (RSS 292) HAS SHIM MIGRATION AT LOWER CORNER. SUPPLEMENTAL DATA UPDATE, REPLACED MIGRATED SHIM WITH SOLID SHIM PER ECRA 5750-04451.SDR UALA2012060503113Packing · leakingFLAP SLAT DEPRESS VALVE LEAKING. REPLACED PACKINGS, OPS CHECKED NORMAL. RESERVE SYSTEM HYD, NO LEAKS.SDR UALA2012061103208Connector · damagedLEFT ELECTRIC HYDRAULIC PUMP INOPERATIVE. RAN FLAPS UP AND DOWN WITH LEFT ELECTRIC PUMP. CREW REPORTED LOW PRESSURE LIGHT WAS ON WITH PUMP ON. SECURED PIN 2 ON CONNECTOR D3100.SDR UALA2012060803128Skin · delaminatedNR 5 LE SLAT HAS 7 FOOT LONG DELAMINATION AFT OF LEADING EDGE. REMOVED NR 5 LE SLAT. REPAIRED SLAT PER MM.SDR UALA2012060803149Skin · damagedLEFT FUSELAGE SKIN CRACKED AND DENTED BS 255 TO 288. ACCOMPLISHED MAJOR REPAIR PER ECRA 5310-05519 REV A.SDR UALA2012060503117Service Panel · faultyABNORMAL NOISE, VIBRATION IN CENTER MAIN CABIN FLOOR. NOTICEABLE VIBRATION FELT ON CLIMB. PASSENGER IN 9C NOTED A LOUD THUMPING AND VIBRATION BELOW FLOOR. ACCOMPLISHED THE REPLACEMENT OF THE RT OVERWING SERVICE PNL. REPLACED OVERWING SERVICE PNL HINGE PER SDR UALA2012060303070Intercostal · crackedMAIN CABIN L2 DOOR FWD CUTOUT INTERCOSTAL CRACKED AT BS 690, STR 12L. MAJOR REPAIR ACCOMPLISHED, INSTALLED NEW INTERCOSTAL REF SRM 51-40-02.SDR UALA2012060303071Intercostal · crackedINTERCOSTAL CRACKED AT BS 675 BELOW S11R. INSTALLED NEW INTERCOSTAL REF SRM 51-40-02 AND DWG 143N8338. MAJOR REPAIRSDR UALA2012060303073Harness · frayedMAIN CABIN R1 DOOR SLIDE HARNESS FRAYED, LOWER CENTER ATTACH POINT. REPLACED SLIDE HARNESS.SDR UALA2012060303074Harness · frayedMAIN CABIN R2 DOOR SLIDE HARNESS FRAYED, CENTER LOWER ATTACH POINT. REPLACED SLIDE HARNESS.SDR UALA2012060303075Harness · frayedMAIN CABIN L4 DOOR SLIDE HARNESS, LOWER ATTACH POINT FRAYED. REPLACED SLIDE HARNESS.SDR UALA2012060303076Harness · frayedMAIN CABIN L1 DOOR SLIDE HARNESS CENTER LOWER ATTACH POINT FRAYED. REPLACED SLIDE HARNESS.SDR UALA2012060303077Cable · looseMAIN CABIN R4 DOOR EMERGENCY POWER SPRING CARTRIDGE RED BAND RECESSED CABLE LOOSE. ADJUSTED CABLE TO ALIGN RED BAND ON PISTON.SDR UALA2012060303084Switch · damagedLEFT ENGINE OVERHEAT LIGHT DOES NOT ILLUMINATE DURING FIRE TESTS. REPLACED LEFT ENGINE OVERHEAT SWITCH BASE, FIRE TEST AND LIGHT TEST OK.SDR UALA2012060103039Actuator · faultyLEFT ENGINE SPAR VALVE LIGHT ILLUMINATED, WITH ENGINE SHUT DOWN. REPLACED LEFT ENGINE SPAR VALVE ACTUATOR PER MM, OPS CHECKED NORMAL.SDR UALA2012060303060Connector · unsecureEMERGENCY FLOOR LIGHTING NOT SECURE REAR OF AIRCRAFT. SECURED EMERGENCY PATH LIGHT CONNECTION AT FWD AFT LAV AT L4 DOOR AND SECURED PATH LIGHT COVER. EMERGENCY LIGHTS OP NORMAL.SDR UALA2012060103056Ballast · defectiveELECTRICAL BURNING SMELL NEAR DOOR 2. FOUND AFT FWD LAV MIRROR LIGHT BALLAST DEFECTIVE & LIGHTS OUT. SMELL DISSIPATED. BALLAST CONNECTOR REMOVED, TAPED & SECURED. DEFER ITEM ENTERED IN ERROR. SMC 01 CREATED FOR THIS DEFECT. BALLAST AND BULBS REPLACED, RASDR UALA2012060103053Window · crackedCAPTAIN'S WINDOW IS SHATTERED ON OUTER LAYER. CAPTAINS' WINDOW REPLACED.SDR UALA2012060103054Window · delaminatedWINDOW 3R HAS A DELAMINATION ABOUT 18 INCHES LONG AND 2 TO 3 INCHES WIDE. CREW STATES WINDOW DELAMINATION DOES DECREASE VISUAL QUALITY. WINDOW WILL NEED TO BE REPLACED. REPLACED NR 3R WINDOW.SDR UAL2012F00003Ballast · defectiveELECTRICAL BURNING ODOR NEAR DOOR 2. FOUND AFT FWD LAVATORY MIRROR LIGHT BALLAST DEFECTIVE AND LIGHTS OUT. ODOR DISSIPATED. BALLAST AND BULBS REPLACED, RAN BOTH ENGINES AND FOUND NO BURNING ODOR.SDR UALA2012053103031Warning Message · false activationLEFT EICAS COMPUTER STATUS MESSAGE CAME ON AT POWER CHANGE. WILL NOT CLEAR, CYCLED 'LT EICAS ' CIRCUIT BREAKER, OPS NOW SATISFACTORY.SDR UALA2012053103034Charger · faultedAPU WON'T START, THREE ATTEMPTS. GET FAULT LIGHT EACH TIME. ACCOMPLISHED APU BITE CHECK FOUND NO ACTIVE FAULTS. STARTED APU NORMAL, OBSERVED APU BATTERY VOLTAGE DROPPED TO 16V, SHUTDOWN APU AND OBSERVERED APU BATTERY CHARGER. AMPS LESS THAN 38.5 AMPS. REPLSDR UALA2012060103038Blade · damagedNR 2 ENGINE BLADE NR 1 IS DAMAGED AT THE BLADE TIP. BLENDED BLADE.SDR UALA2012052903022Rudder Control · malfunctionedEICAS MESSAGE 'RUDDER RATIO' DISPLAYED, RUDDER RATIO LIGHT ILLUMINATED ON GROUND. RUDDER RATIO LIGHT ON TAKEOFF ROLL AND IN FLIGHT CROSS WIND LIMITED TO 15 KNOTS. REPLACED RUDDER RATIO CHANGER.SDR UALA2012052802999Module · faultyELEVATOR FEEL STATUS MESS ON TAKEOFF ROLL. DUE REPEAT, RECOMMEND TO ACP SVC TIP MM. PITOT LEAK CHECK AND POSSIBLY WILL NEED ELEVATOR FEEL COMP REPLACED.SDR UALA2012052903021Pressure Switch · faultyRIGHT CENTER PUMP FUEL PUMP EICAS MESSAGE NOT WORKING. PUMP WORKS BUT NO EICAS MESSAGE. REPLACED RT OVERRIDE PRESSURE SWITCH PER AMM, OPS CHECKED GOOD.SDR UALA2012052903023Engine · hung startNUMBER 2 ENGINE HUNG START ON TWO ATTEMPTS. ATTEMPTED SECOND START WITH BOTH IGNITIONS ENGINE START PARAMETERS NORMAL, STARTS OKAY.SDR UALA2012052903019Overheat Sensor · looseEICAS MSG-EQPT OVHT & EQPT CLG FAN- OVERHEAT LIGHT ILLUMINATED. OVERHEAT LIGHT REMAINED ILLUMINATED WHEN ALTN WAS SELECTED. RIGHT PAC DISCHARGE TEMP BECAME LOOSE FROM DUCT CAUSING PAC TO OVERHEAT, AFTER TEMP INSTALLATION OF SENSOR PAC TEMP NORMAL AND EQT COOSDR UALA2012052702975Cap · missingROW 12 AND ROW 40 FLOOR EMERGENCY EXIT LIGHTS MISSING END OF STRIP. REPLACED END CAPS 2 AT ROW 12 AND ROW 40 (PCN 160-7705).SDR UALA2012052702984Angle · crackedNR 2 ENGINE PYLON LT SIDE ANGLE CRACKED AT NACELLE STA 156.00 AND STA 161.00. MAJOR REPAIR ACCOMPLISHED: REMOVED AND FABRICATED NEW ANGLE. INSTALLED NEW ANGLE PER SRM 51-40-02.SDR UALA2012052702988Bearing · wornVIBRATION AND HUM IN FLIGHT AT ROWS 10, 11, AND 21. ROWS 11, 22 AND 28 THE NOISE SEEMS TO BE GETTING LOUDER. EARLIER IN DESCENT THE NOISE WAS LESS BUT VIBRATION STILL THE SAME IN ROWS 11, 22 AND 28. FOUND RIGHT RAM AIR HEAT SINK OUTLET DOOR HINGES WORN WITSDR UALA2012053103035Circuit Card · malfunctionedLEFT ENGINE BLEED OFF LIGHT ILLUMINATED WITH LT ENG BLEED OFF EICAS MESSAGE WITH ENGINE RUNNING. CYCLED BLEED SWITCH SEVERAL TIMES AND ENGINE POWER INCREASED TO 50% N1 TWICE WITH NO HELP. RESEATED LEFT ECS ENGINE BLEED CARD. PERFORMED PNEU SYSTEM TEST PER JSDR UALA2012052702976Relay · faultyRIGHT ENGINE PROBE HEAT STATUS MESSAGE BEFORE DISPATCH. RERACK SPEED CARD AND RIGHT ENGINE PROBE RELAY K10478. CLEARED MESSAGE.SDR UALA2012052702987Skin · delaminatedFOUND DELAMINATION ON NR 5 LEADING EDGE SLAT INBD TRAILING EDGE WEDGE, APPROX 19 X 7 1-2 INCH AREA. TOP AND BOTTOM DELAMINATION. ACCOMPLISHED MM 27-81-01 THRU STEP D (13) PAGE 403. REMOVED AND REPLACED SLAT FOR REPAIR. INSTALLED SLAT 3 MAIN TRACK BOLTS ANDSDR UALA2012052702961Bulb · inoperativeEMERGENCY LIGHT IN STOW BIN AT SEAT 30C INOPERATIVE. RELAMPED 1317 BULB. TESTED USING AFT FLIGHT ATTENDANT EMERGENCY LIGHT SWITCH. NORMAL OPERATION OBSERVED.SDR UALA2012052702968Floorbeam · corrodedMAIN CABIN BS 324 FLOORBEAM UPPER CHORD HAS CORROSION FROM RBL 46 TO RBL 55. MAJOR REPAIR ACCOMPLISHED: PERFORMED REPAIR TO MAIN CABIN STA 324 FLOORBEAM PER ECRA 5310-05518 AND EA PT57-53- 006.SDR UALA2012052702973Battery · inoperativeEEL PATH LIGHT AND STOWBIN EMERGENCY LIGHT INOPERATIVE ROW 25 TO 35. FOUND BATTERY AT POS M735 BAD REPLACED PER MM.SDR UALA2012052702960Switch · brokenDOOR 2L EMERGENCY LIGHT TEST SWITCH INOPERATIVE. FOUND TERMINAL BLADE BROKEN OFF OF SWITCH S10293 REF WDM 33-51-13 (PCN 564-0147) REPLACED SWITCH. FOUND WIRE TERMINAL SPADE CRACKED. REPLACED TERMINAL (PCN 562 -1675) REF SWPM20-30-15. TESTED EMERGENCY LIGHT
Back to Pratt & Whitney PW2037