Pratt & Whitney PW4056
Service difficulty reports · 12,595
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE engine_model_key = 'PW4056' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE engine_model_key = 'PW4056' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR UALA2011011700285Light · inoperativeEMERGENCY EXIT LIGHT AT DOOR 2 GALLEY AREA FWD LOWER WALL AT RIGHT SIDE INOP AND CENTER LIGHT LENS MISSING. SUPPLEMENTAL DATA UPDATE, REPLACED LENS AND RELAMPED.SDR UALA2011011700286Light · inoperativeEMERGENCY EXIT LIGHT INOP CEILING ROW 20 RIGHT. RELAMPED, CHECKS OKAY.SDR UALA2011011700287Light · inoperativeEMERGENCY EXIT EEL LIGHT INOP SEAT ROW 55 RIGHT. RELAMPED, CHECKS OKAY.SDR UALA2011011700288Light · inoperativeEMERGENCY EXIT LIGHT INOP DOOR 3 RIGHT BUSSLE. SUPPLEMENTAL DATA UPDATE RELAMPED, CHECKS OKAY.SDR UALA2011011700289Feeder Cable · out of toleranceEMERGENCY EXIT EEL LIGHTS INOP SEAT ROWS 45 THRU 54 LEFT, DOOR 4 LEFT FWD EXIT SIGN, DOOR 4 RIGHT AFT EXIT SIGN, LOWER WALL EEL ACROSS DOOR 4 LEFT, AND DOOR 4 GALLEY AREA LOWER WALL EEL. THIS IS A REPETITIVE PROBLEM IN THIS SPECIFIC AREA ON 84XX AIRCRAFT. SUSDR UALA2011011700265Light · inoperativeEMERGENCY CEILING LIGHT IN ROW BETWEEN SEATS 19GFE AND 19KJH IS INOP. SUPPLEMENTAL DATA UPDATE, RELAMPED EMERG CEILING AT THE ABOVE STATED POSITION. OPS CHK NORMAL.SDR UALA2011011700266Light · inoperativeEMERGENCY CEILING LIGHT IN ROW BETWEEN SEATS 46 AND 47 ABC IS INOP. RELAMPED EMERGENCY CEILING LAMP IN LT ROW BETWEEN SEATS 46 ABC AND 47 ABC. OPS CHK NORMAL.SDR UALA2011011700267Light · inoperativeAFT GALLEY CROSS OVER LIGHT NEAR FLOOR IS INOP. REPLACED CROSS OVER EEL LIGHT NEAR FLOOR ON LT SIDE IN AFT GALLEY. OPS CHK NORMAL.SDR UALA2011011700268Battery · faultyEXIT SIGN AT DOOR 1R IN ROW IS BLINKING. ACCOMPLISHED TROUBLESHOOTING PER DW. REPLACED BATTERY AND POWER SUPPLY.SDR UALA2011011700269Light · damagedEMERGENCY LIGHT ON SEAT 4K IS INOP. REPAIRED.SDR UALA2011011700270Light · inoperativeEMERGENCY LIGHT ON SEAT 1K IS INOP. REPAIRED.SDR UALA2011011700271Light · inoperativeEMERGENCY LIGHT ON SEAT 3K IS INOP. REPAIRED.SDR UALA2011011700260Scavenge Pump · faultyCTR TANK DID NOT SCAVANGE COMPLETELY, .8 USEABLE FUEL AFTER PUMP OFF. AIR MODE SCAVENGE SYST TEST FAILED. SCAVANGE PUMP WAS REPLACED AND LEAKED CHECKED. SCAV PUMP CB PULLED & COLLARED IN P414 PANEL. THIS SCAVG TEST WILL TAKE APPPOX 3-4 HRS. ADJUSTED TO REFLSDR UALA2011011400236Latch · contaminatedF/A REPORTS ODOR OF HOT OIL IN AFT GALLEY. CLEANED RESIDUAL OIL FROM COMPARTMENT LATCH AT 523.SDR UALA2011011400237Dau · malfunctionedINTERMITTENT SATCOM LOST AND ACARS NO COMM. REPLACED SATELLITE DATA UNIT PER MM.SDR UALA2011011400238Structure · puncturedDOOR 1R SLIDE BUSTLE AFT SIDE HAS TWO EACH PUNCTURES APPROX 3-4 INCH DIAMETER EA. ACCOMPLISHED REPAIR ON BUSTLE. GOUGE LESS THAN THREE INCHES LONG AND DOES NOT GO THROUGH BUSTLE.SDR UALA2011011400221Hinge Fitting · crackedLEFT WING INBOARD FLAP ASSY HAS CRACK ON CENTER AFT FLAP HINGE FITTING. MAJOR REPAIR ACCOMPLISHED: CUT-OUT DAMAGED AREA AND FABRICATED A REPAIR ANGLE AND FILLERS AND INSTALLED PER SRM, REPAIR 1, ON NON ROUTINE.SDR UALA2011011400233Light · inoperativeSEAT 4H FWD EMERGENCY LIGHT IS INOPERATIVE. REPLACED OP CHECKED GOOD.SDR UALA2011011400234Pin · bentAPU WON'T START. REPLACED BATTERY, CHARGER TWICE AND K116 ALL NO HELP. CAL BATTERY CHARGER REMOVED AND RETURNED TO CAL. FOUND PIN 9 OF D302 BENT AND SHORTING CAUSING BATTERY CHARGER TO SHUT OFF. REPAIRED PIN AND CHARGING SYSTEM CHECKS OKAY.SDR UALA2011011400228Lamp · inoperativeDOOR 4 LEFT BUSTLE. RELAMPED.SDR UALA2011011400229Lamp · inoperativeSEAT 45 LEFT. RELAMPED.SDR UALA2011011400230Lamp · inoperative33HJK SEAT EMERGENCY LIGHT INOPERATIVE. RELAMPED.SDR UALA2011011400231Lamp · inoperativeEMERGENCY LIGHT AT 33 LEFT INOPERATIVE. REPLACED LAMP ASSY.SDR UALA2011011400227Light · corrodedDOOR 4 GALLEY LWR WALL LIGHT IS FAULTY. REPLACED CORRODED POWER EEL STRIPPING.SDR UALA2011011200185Seat Track · corrodedSEAT TRACK DAMAGED AND CORRODED BEYOND SRM LIMITS FROM STA 1208-1439 AT RBL 88.5. MAJOR REPAIR ACCOMPLISHED: REMOVED AND REPLACED SEAT TRACK PER SRM.SDR UALA2011011200186Seat Track · corrodedCABIN SEAT TRACK HAS CORROSION AND DAMAGE BEYOND LIMITS FROM STA 1230 TO STA 1362 AT LBL 88.5. MAJOR REPAIR ACCOMPLISHED: REMOVED AND REPLACED SEAT TRACK ASSY PER SRM.SDR UALA2011011200187Floorbeam · corrodedFLOORBEAM CORRODED NEAR DOOR R1 AT STATION 287 RBL 80. MAJOR REPAIR ACCOMPLISHED: REPAIR TO FLOORBEAM AT STA 287 AT RBL 80 ON EA NR PD67-53-027 ON NR 2389N00 676.SDR UALA2011011200189Battery Pack · faultyFWD GALLEY FLOOR EMERGENCY LIGHT INOPERATIVE. REPLACED FWD GALLEY EMERGENCY LIGHT ASSY AND BATTERY PACK, CHECKS GOOD.SDR UALA2011011200190Connector · unsecureSEAT 20AB EMERGENCY LIGHT INOPERATIVE. SECURED UNDER SEAT CONNECTOR, CHECKS GOOD.SDR UALA2011011200191Feeder Cable · disconnectedLEFT MID LAV FLOOR EMERGENCY LIGHT INOPERATIVE. RECONNECTED FEEDER CABLE, CHECKS GOOD.SDR UALA2011011200192Feeder Cable · disconnectedIN FRONT OF SEATS 21DEF FLOOR EMERGENCY LIGHT INOPERATIVE. RECONNECTED AT FEEDER CABLE, CHECKS GOOD.SDR UALA2011011200193Feeder Cable · damagedEMERGENCY LIGHT ROW 45 THROUGH 53 INOP. REPLACED EMERGENCY CABLE. OP CHECKED NORMAL.SDR UALA2011011200194Feeder Cable · faultedEMERGENCY LIGHT FWD AND SIDE OF MAIN GALLEY WALL ON L4 DOOR INOPERATIVE. REPLACED EMERGENCY CABLE ALONG FWD WALL GALLEY. OP CHECKED NORMAL.SDR UALA2011011200195Lamp · inoperativeEMERGENCY LIGHT ALONG DR2 RT AISLE INOP. RELAMPED. OP CHECKED NORMAL.SDR UALA2011011200196Lamp · inoperativeEMERGENCY CEILING LIGHT ABOVE ROW 12 INOP. RELAMPED OPS NORMALSDR UALA2011011200197Lamp · inoperativeEMERGENCY CEILING LIGHT ABOVE ROW 15 INOPERATIVE. RELAMPED, OPS NORMAL.SDR UALA2011011200198Feeder Cable · inoperativeEMERGENCY LIGHT GALLEY WALL R5 DOOR INOPERATIVE. REPLACED POWER FEEDER CABLE AND LIGHT ASSY. OPS CHECKED NORMAL.SDR UALA2011011200199Lamp · inoperativeEMERGENCY LIGHT ON SEAT 14 LT INOP. RELAMPED, OPS NORMAL.SDR UALA2011011200200Lamp · inoperativeEMERGENCY CEILING LIGHT ABOVE ROW 45 RT INOPERATIVE. RELAMPED, OPS NORMAL.SDR UALA2011011200201Lamp · inoperativeEMERGENCY CEILING LIGHT ABOVE ROW 17 INOP. RELAMPED, OPS NORMAL.SDR UALA2011011300214Structure · damagedDURING C08 CHECK A DAMAGED FASTENER HOLE WAS FOUND ON THE RT INBD MAIN FLAP AT STA 108, AFFECTING 3 SEPARATE PARTS, THE FLAP LOWER NL, INBD END RIB LWR FLANGE AND LOWER STRAP. REPAIR WAS ACCOMPLISHED PER EVA 80458.SDR UALA2011011300218Reservoir · low pressureLT UPPER DECK DOOR AFT SLIDE RESERVOIR PRESSURE IS BELOW GREEN BAND AT APPROX 2600 PSI. DEFERED PER MEL, DOOR BLOCKED OFF AND PLACARDED. REPLACED AFT LT UPPER DECK RESERVOIR.SDR UALA2011011200176Bleed Valve · faultyLEFT ENG HIGH STAGE BLEED VALVE WON`T OPEN. ONLY 5 PSI AT IDLE. LOCKED LEFT ENG HIGH STAGE BLEED CLOSE. REPLACED NR 1 ENGINE HPSOV PER MM, OPS CHECKED GOOD, 33 PSI AT IDLE, 28 PSI WITH A SINGLE PACK OPERATING AND 21 PSI WITH TWO PACKS OPERATING.SDR UALA2011011200164Light · unsecure21HJK SEAT MOUNTED EMERGENCY LIGHT STRIP ADRIFT. SECURED EMERGENCY LIGHT. OPS NORMAL.SDR UALA2011011200165Lavatory · underservicedLAVS INOP, FLIGHT DIVERTED. APPEARS FWD TANKS (LT AND RT) ARE SHUTDOWN. NO AHM DATA SHOWING ANY FAILURES. SENSOR "INOP" LIGHTS ARE ILLUMINATED ON ACCESS PANEL (R2 DOOR) FOR LAV BOTH FWD LAV TANKS. LAVATORY TANKS SERVICED PROPERLY AND ALL LIGHTS WENT OUT WISDR UALA2011011000149Lamp · inoperativeSEAT 43L EMERGENCY LIGHT INOPERATIVE. RELAMPED CKS OK.SDR UALA2011011000150Lamp · inoperativeSEAT 45R EMERGENCY LIGHT INOPERATIVE. RELAMPED, CHECKS OKAY.SDR UALA2011011000151Lamp · inoperativeRT EMERGENCY CEILING LIGHT INOP ACROSS FROM FIRST CLASS GALLEY. RELAMPED, CHECKS OKAY.SDR UALA2011011000152Fuse · inoperativeLEFT OVERWING 2 AFT EMERGENCY LIGHTS INOPERATIVE. REPLACED FUSE, CHECKS OKAY.SDR UALA2011011200161Valve · faultyAPU DUCT PSI DOES NOT INCREASE FOR ENG START. TAKES TWO MINS TO REACH STARTER CUTOUT APU BLEED VALVE CONFIRMED CLOSED. FOUND SURGE VALVE STUCK PARTIALLY OPEN. REPLACED SURGE VALVE. OPS AND LEAK CHECKED GOOD.
Back to Pratt & Whitney PW4056