Pratt & Whitney PW4056
Service difficulty reports · 12,595
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE engine_model_key = 'PW4056' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE engine_model_key = 'PW4056' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR UALA2010060902007Terminal Block · faultyRH 3RD OVERWING EMERGENCY LIGHT TERMINAL BLOCK (GROUND) BROKEN. REPLACED LIGHT ASSY. OP CK NORMAL.SDR UALA2010060902009Lamp · inoperativeEMERGENCY EXIT LIGHT INOP. UPPER DECK CEILING ROW 13. RELAMPED. OPS. CKS. NORMALSDR UALA2010060902011Lamp · inoperativeEMERGENCY EXIT LIGHT INOP. SEAT ROW 54 LEFT. RELAMPED. OPS. CKS. NORMALSDR UALA2010060902013Controller · faultySTATUS MESSAGE: BLEED HP ENG 1. NO TIME FOR T-S. HP VALVE SECURED IN CLOSED POSITION. HIGH PRESSURE CONTROLLER LOCATED IN LOB ABOVE DOOR 2L. REPLACED HPC. OPS ARE NORMAL.SDR UALA2010060902014Slide · reads lowMED 5R SLIDE PSI IS LOW. REPLACED SLIDE RAFT AT DOOR 5R. ACCOMPLISHED INSPECTION OF DOOR 5RT SLIDE INSTALLATION PER MM.SDR UALA2010061102053Slide · failedDURING OVER PRESSURE TEST, SLIDE BLEW AT THE RAMP SECTION ON THE RT. UPPER SIDE. CHECKED ASPIRATORS, NO DAMAGE.SDR UALA2010061002034Charger · malfunctionedMAIN BAT CHGR STATUS WILL NOT ERASE. REPLACED MAIN BATTERY CHARGER AND CKD IAW MM. CKD NORMAL.SDR UALA2010061002035Battery · faultyEICAS MSG MAIN BATTERY CHARGER. REPLACED BATTERY, OPS GOOD.SDR UALA2010060902018Generator · faultyAPU INOP ELECTRICAL. UNABLE TO LOAD GENERATOR. REPLACED APU GENERATOR.SDR UALA2010060801998Light · corrodedEMERGENCY LIGHTS INOP AT SEATS 45-53 ABC IN ADDITION TO 4L EXIT EXIT AND 4R EXIT AND LOWER EMERGENCY LIGHT WALL ACROSS 4L AND 4L LOWER GALLEY AREA. REPAIRED WET AND CORRODED EMERGENCY LIGHTING.SDR UALA2010060701978Connector · unsecureEMERGENCY EXIT LIGHTS INOP. FIRST CLASS AREA SEAT ROWS 2 THRU 4 INBD SEATS. SECURED CONNECTOR. OPS CKS NORMAL.SDR UALA2010060701976Lamp · inoperativeEMERGENCY EXIT LIGHT INOP. DOOR 2 GALLEY AREA RT LOWER WALL. RELAMPED. OPS NORMAL.SDR UALA2010060701977Light · inoperativeEMERGENCY EXIT EMERGENCY LIGHT INOP. SEAT ROW 56 LT. REPLACED LIGHT ASSY OPS CKS. NORMAL.SDR UALA2010060701979Feeder Cable · saturatedEMERGENCY EXIT LIGHTS INOP. SEAT ROWS 45 THRU 53 LT, DOOR 4 LT FWD EXIT SIGN, DOOR 4 RT AFT EXIT SIGN, LOWER WALL EMERGENCY LIGHT ACROSS DOOR 4 LT AND DOOR 4 GALLEY AREA LOWER WALL EMERGENCY LIGHT. THIS IS A REPETITIVE PROBLEM IN THIS SPECIFIC AREA ON ACFT. FSDR WRLA20100607364Door Frame · crackedCRACK - LEFT NR 5 ENTRY DOOR FWD CENTER FRAME CRACK. NRC U05069 ISSUED. TRIM OUT THE DAMAGE FRAME AND KEEP 0.5 INCH RADIUS PER NDT MANUAL PART 6 51-00-00, FIG 23 ENSURE THE TRIM OUT AREA FREE OF CRACK.SDR WRLA20100607393Stiffener · wornNR 1 ENG RT CORE COWL HAS ANGLE WEAR NEAR SUPPORT ROD END. REMOVED DAMAGE PARTS AND FABRICATE NEW PARTS IAW EI W2010P548-1283 REV 00. RE-INSTALLED NEW PARTS IAW SRM 51-40-02 REV 76. JOB COMPLETED AND CONDITION CHECK NORMAL.SDR WRLA20100607388Attach Angle · crackedCRACK - FOUND NR 3 ENG LEFT T/R TORQUE BOX ATTACH BRACKET CRACK AT 8 O'CLOCK POSITION. REMOVED THE CRACK BRACKET IAW 747-400 SRM 51-40-02 REV 76. PERFORMED E/I W2010P78B-1235 REV 00 FABRICATION - BRACKET (P/N: 315T3633-39) OF NR 3 ENGINE LEFT T/R TORQUE BOXSDR WRLA20100607390Angle · crackedCRACK - CRACK WAS FOUND ON ANGLE (P/N 69B13824-5) OF RT WING T/E RIB INSTALLATION AT STA WBL 432.65. FABRICATE & INSTALL NEW ANGLE PER DWG 69B13824. NOTE: THIS SDR IS A DUPLICATE OF SDR WRLA20100604387.SDR UALA2010060701970Receptacle · failedGROUND POWER RECEPTICAL FAILED NO-GO GAUGE TEST. UNABLE TO ACP DURING A-CK VISIT. ORDERED RECEPTACLE. PART NOT STOCKED HNL. REPLACED RECEPTACLE. TASK COMPLETED.SDR UALA2010060701982Pump · leakingNR 2 ENGINE DRIVEN PUMP IS LEAKING HYDRAULIC FLUID. REMOVED & REPLACED LEAKING ENGINE DRIVEN PUMP. OPS NORMAL.SDR WRLA20100604387Bracket · crackedCRACK - BRACKET, RIB-ASSY - INBOARD T/E COMPARTMENT WBL 432.65 RT WING. REMOVED THE ANGLE IAW SRM 51-40-02 REV 76. PERFORMED E/I W20/OP57B-1231 REV 00 INSTALLATION AT STA WBL 432.65. INSTALLED THE ANGLE IAW SRM 51-40-02 REV 76. CONDITION CHECK NORMAL AND SDR WRLA20100604389Attach Bracket · crackedCRACK - BRACKET, LANDING GEAR SUPPORT BEAM FRONT SPAR, WBL 130, RIGHT WING. REPLACED THE BRACKET, LANDING GEAR SUPPORT BEAM FRONT SPAR WBL 130 RIGHT WING IAW SRM 51-40-02 REV 76. JOB COMPLETED AND COND CHECK NORMAL.SDR UALA2010060301939Charger · inoperativeLT OVERWING 2 BOTTOM EMERGENCY LIGHT INOPERATIVE. REPLACED BATTERY CHARGER. OP CK NORMAL.SDR UALA2010060301940Battery · faultyR1 DOOR AFT EXIT SIGN INOPERATIVE. REPLACED BATTERY ABOVE DR1 RT. OPS CK NORMAL.SDR UALA2010060301941Battery · faultyR1 DOOR GALLEY SIDEWALL EMERGENCY LIGHT INOP. REPLACED BATTERY. OP CK NORMAL.SDR UALA2010060301942Lamp · inoperativeL2 DOOR FWD GALLEY ONE EMERGENCY WALL LIGHT INOPERATIVE. RELAMPED OPS GOOD.SDR UALA2010060301943Wire · inoperativeEMERGENCY LIGHT SEAT 45-53 LT INOP. CLEANED AND SECURED WET EMERGENCY LIGHT WIRING.SDR UALA2010060301944Wire · faultyMAIN GALLEY EMERGENCY WALL LIGHT FWD AND SIDE INOP. CLEANED AND SECURED WET EMERGENCY LIGHT WIRING. OPS ARE OK.SDR UALA2010060401953Light · unsecureLAV 101 ON LT SIDE EMERGENCY LIGHT FALLING OUT. SECURED EMERGENCY LIGHT IN PLACE, OPS OK.SDR UALA2010060401954Tension Tie · crackedCRACK- 8 EACH FWD TENSION TIE HOLES AT STA 1200 LT. MAJOR REPAIR ACCOMPLISHED: REMOVED DAMAGED TENSION TIE. HFEC-NO CRACKS. FABRICATED AND INSTALLED REPAIR PARTS IAW SRM.SDR UALA2010060301912Lamp · inoperativeSEAT 6AB EMERGENCY CEILING LIGHT INOPERATIVE. RELAMPED EMERGENCY AISLE LIGHT AT SEAT ROW 6AB. PERFORMED GOOD OPS CHECK.SDR UALA2010060301913Light · inoperativeEMERGENCY LIGHT AT SEAT 40 RT SIDE, INOPERATIVE. R & R LIGHT AT SEAT 40 RT, OPS CHECK GOOD.SDR UALA2010060301914Battery · faultyRT ROW 15-28, EMERGENCY CEILING LIGHTS INOP. R &R BATTERY, OPS CHECK GOOD.SDR UALA2010060301915Regulator · out of toleranceAPU OIL COOLER NEEDS REPLACEMENT. REPLACED APU OIL COOLER IAW JIC. OPS NORMAL.SDR UALA2010060301925Lamp · inoperativeEMERGENCY EXIT LIGHT INOP. CEILING ABOVE LAV 101. RELAMPED. OPS. NORMAL.SDR UALA2010060301926Lamp · inoperativeEMERGENCY EXIT LIGHTS INOP. DOOR 2 GALLEY AREA LOWER WALL CTR AND RT LIGHTS. RELAMPED. OPS NORMAL.SDR UALA2010060301927Connector · unsecureEMERGENCY EXIT LIGHT INOP. SEAT ROW 36 LT. SECURED CONNECTOR. OPS CK NORMAL.SDR UALA2010060301928Light · inoperativeEMERGENCY EXIT LIGHT INOP, SEAT ROW 46 RT. REPLACED LIGHT ASSY. OPS CK NORMAL.SDR UALA2010060301929Feeder Cable · saturatedEMERGENCY EXIT LIGHTS INOP, SEAT ROWS 45 THRU 53 LT, DOOR 4 LT FWD EXIT SIGN, DOOR 4 RT AFT EXIT SIGN, LOWER WALL EMERGENCY LIGHT ACROSS DOOR 4 LT, AND DOOR 4 GALLEY AREA LOWER WALL EMERGENCY LIGHT. FOUND WATER PUDDLING IN GALLEY AREA UNDER GALLEY FLOOR MAT ASDR UALA2010060301930Smoke Detector · faultyCARGO FWD-1 LOOP-B ON STATUS PAGE. HAS PREVIOUS HITS, MSG26161. REPLACED CARGO SMOKE DETECTOR.SDR UALA2010060301931Wire · openEMERGENCY EXIT LIGHT INOP, DOOR 1 LT BUSSLE. FOUND OPEN WIRE FROM TB205 TO DX317 SLIDE LT DOOR 1L, REPLACED WIRE FROM TB205 TO DX317 PIN 2. INSTALLED AND SECURED WIRING REF WDM. EMERGENCY LTS CHECK GOOD OPERATE NORMAL.SDR UALA2010060101881Light · inoperativeEMERGENCY EXIT LIGHT INOP. SEAT ROW 23 LEFT. REPLACED.SDR UALA2010060101883Floorbeam · crackedCRACKED UPPER DECK FLOORBEAM STA 440 RBL 58. REMOVED DAMAGE. HFEC. FABRICATED AND INSTALLED REPAIR IAW KAL FIELD REPAIR RECORD UAL-744-0637 REVISION 00 DATED 27 MAY, 2010.SDR UALA2010060101884Lamp · inoperativeEMERGENCY EXIT LIGHT INOP, DOOR 2 GALLEY AREA CTR LOWER WALL. RELAMPED, OPS NORMAL.SDR UALA2010060101885Feeder Cable · saturatedEMERGENCY EXIT LIGHTS INOP. SEAT ROWS 45 THRU 53 LT, DOOR 4 LT FWD EXIT SIGN, DOOR 4 RT AFT EXIT SIGN, LOWER WALL EMERGENCY LIGHT ACROSS DOOR 4 LT, AND DOOR 4 GALLEY AREA LOWER WALL EMERGENCY LIGHT. THIS IS A REPETITIVE PROBLEM IN THIS SPECIFIC AREA ON 84XX SDR UALA2010060301903Light · missingEMERGENCY EXIT LIGHT STRIP MISSING SEAT 10B. R & R LIGHT ASSY AND OPS CHECK GOOD.SDR UALA2010060301904Light · inoperativeEMERGENCY LIGHT AT SEAT 40HJ INOPERATIVE. R & R PATH LIGHT AT SEAT ROW 40HJ, OPS CHECK GOOD.SDR UALA2010060301905Strap · looseR-1 DOOR SLIDE SAFETY STRAPS ARE LOOSE, 4 OF 5 CABLE BALL ENDS ARE NOT SECURE IN SLIDE FRAME ON AFT END. REMOVED R-1 DOOR SLIDE AND RESECURED SLIDE CABLE ENDS. REINSTALLED DOOR SLIDE.SDR UALA2010060301906Stiffener · crackedFLOORBEAM AT BS 246, FWD FACE STIFFENER CRACKED AT LBL 26. MAJOR REPAIR ACCOMPLISHED: R & R FLOORBEAM STIFFENER AT BS 246, LBL 26.SDR UALA2010060301907Bracket · crackedFLOORBEAM AT BS 246, FWD FACE PULLEY SUPPORT BRACKET IS CRACKED AT LBL 4. MAJOR REPAIR ACCOMPLISHED: R & R BRACKET.
Back to Pratt & Whitney PW4056