SDR 2008UALA06107Cover · missingMAIN DECK SEAT 5F EMERGENCY EXIT MISSING COVER PLATE. EEL STRIP REPLACED AND OPS CHECK OK.SDR 2008UALA06108Light · inoperativeEMERGENCY EXIT LIGHT INOP UPPER DECK CEILING ROW 12. LIGHT IS UNSERVICEABLE. REPLACED LAMP. ALL CHECKS GOOD.SDR 2008UALA06109Light · inoperativeEMERGENCY EXIT LIGHT INOP UPPER DECK CEILING ROW 13. LAMP IS UNSERVICEABLE. REPLACED LAMP. OP CHECKS OKAY.SDR 2008UALA06110Light · inoperativeEMERGENCY EXIT LIGHT INOP UPPER DECK CEILING ROW 16. LIGHT IS INOPERABLE. REPLACED LAMP, CHECKS GOOD.SDR 2008UALA06111Light · inoperativeEMERGENCY EXIT EEL LIGHT INOP UPPER DECK SEAT 17AB FWD LIGHT ASSY. LAMP FOUND INOPERATIVE. REPLACED LAMP, ALL CHECKS GOOD.SDR 2008UALA06112Lamp · inoperativeEMERGENCY EXIT LIGHT INOP, MAIN STAIRS ILLUMINATION LIGHT. RELAMPED EMERGENCY LIGHT. CHECKS OKAY.SDR 2008UALA06113Light · inoperativeEMERGENCY EXIT LIGHT INOP, AT ROW 6 LEFT CEILING LIGHT. LIGHT IS INOPERATIVE. REPLACED LAMP, CHECK NORMAL.SDR 2008UALA06114Light · inoperativeEMERGENCY EXIT EEL LIGHT INOP AT ROW 2A AFT LIGHT ASSY. LIGHT FOUND DEFECTIVE. REPLACED LAMP, OP CHECKS NORMAL.SDR 2008UALA06115Light · inoperativeEMERGENCY EXIT EEL LIGHT INOP AT SEAT 57 RIGHT. LIGHT IS FAULTY. REPLACED LAMP, OP CHECKS NORMAL.SDR 2008UALA06116Light · inoperativeEMERGENCY EXIT EEL LIGHT INOP AT DOOR 5 LEFT AFT LOWER WALL EEL. RELAMPED EMERGENCY LIGHT.SDR 2008UALA06117Battery Pack · defectiveEMERGENCY BATTERIES DISCHARGE QUICKLY AT DOOR 1 LT AND DOOR 1 RT. BATTERIES ARE DEFECTIVE. REPLACED BATTERY PACKS, OP CHECKS OKAY.SDR 2008UALA06118Battery Pack · defectiveDOOR 1 LT AREA EMERGENCY LIGHT NOT ON. BATTERY FOUND DEFECTIVE. REPLACED BATTERY PACK, OP CHECKS OKAY.SDR 2008UALA06119Lamp · inoperativeSLIDE EMERGENCY LIGHT NOT ON AT DOOR 1 LT. LIGHT FOUND INOPERATIVE. REPLACED LAMP, OP CHECK OKAY.SDR 2008UALA06073Wire · brokenFOUND AFT GALLEY EMERGENCY LIGHT WIRE BROKEN. REPLACED AFT GALLEY LOWER SIDE WALL EMERGENCY LIGHT AND SECURED RIBBON CABLE. EMERGENCY EMERGENCY LIGHTS OP CHECKS NORMAL.
SDR 2008UALA06080Light · inoperativeEMERGENCY LIGHT SEAT 24ABC INOP. LIGHT IS INOPERATIVE. REPLACED EMERGENCY LIGHT. OP CHECK NORMAL.
SDR 2008UALA06081Cable · defectiveEMERGENCY LIGHT ROW 45-55 ABC INOP. CABLE HAS MALFUNCTIONED. REPLACED EEL CABLE. OP CHECK NORMAL.
SDR 2008UALA06085Frame · crackedAFT CARGO BS 1560 LBL 20-30 FRAME UPPER CHORD CRACKED. MAJOR REPAIR ACCOMPLISHED. REMOVED DAMAGE, INSTALLED ANGLE REPAIR.SDR 2008UALA06079Light · inoperativeEMERGENCY FWD GALLEY LIGHT INOP. RELAMPED EMERGENCY LIGHT, OP CHECK NORMAL.
SDR 2008UALA06082Light · inoperativeEMERGENCY LIGHT FWD AFT AND LT WALL IN THE AFT GALLEY INOP. REPLACED FWD AND AFT LAMP, OP CHECKS NORMAL.
SDR 2008UALA06095Shutoff Valve · malfunctionedLT ENG REACHED 490 DEG DURING SLUGGISH START. TAXI TEMPS ELEVATED ALSO CLIMB/CRUISE NORMAL. REPLACED NR 1 ENG HPSOV & HP CONTROLLER. OPS CHECK GOOD. REPLACED NR 1 ENGINE.
SDR 2008UALA06056Light · missingFLOOR EEL LIGHT MISSING SEAT 54 HJK. LIGHT DISCOVERED MISSING. REPLACED SEAT EEL LAMP. OPS CHECK OK.SDR 2008UALA06057Light · missingFLOOR EEL LIGHT MISSING SEAT 56HJK. REPLACED EEL LAMP SEAT. OPS CHECK OK.SDR 2008UALA06058Wire · damagedAFT GALLEY LWR LEFT TWO EEL LIGHTS INOP. REPLACED DAMAGED SUPPLY WIRE DUE. OPS CHECK OK.SDR 2008UALA06059Wire · damagedFLOOR EEL LIGHTS INOP SEAT 45 TO 53 ABC. REPLACED BAD AND WET SUPPLY WIRE FOR EEL LIGHT SYS. OPS CHECK OK.SDR 2008UALA06060Regulator Valve · faultyC-HYD DEM PUMP EICAS AND PRESS LIGHT ILLUM WITH AIR DEM PUMP SWITCH IN ON POSITION ONLY WITH POWER AT IDLE. SUSPECT MAYBE C1 DEMAND PUMP LOW OUTPUT. REPLACED ADP, NO HELP. SUSPECT OVERSPEED CARD. REPLACED SPEED CARD, NO HELP. REPLACED ADP PRESSURE REGULATOSDR 2008UALA06062Light · inoperativeEEL LIGHT SEAT 42 ABC INOP. LIGHT INOPERATIVE. REPLACED LAMP, OPS NORMAL.SDR 2008UALA06063Light · inoperativeEMERGENCY CEILING LIGHT AFT OF DOOR 1 LEFT INOP. LAMPED FOUND INOPERATIVE. REPLACED LAMP, OPS NORMAL.SDR 2008UALA06064Connector · contaminatedFLOOR EEL LIGHTS INOP SEAT 54 TO 60 HJK. FOUND CONNECTION AT DOOR 5 CROSSAISLE FOR EMERGENCY LIGHT, WET AND SHORTING CONNECTION. DRIED AREA & CONNECTION. ALL OPS NORMAL.SDR 2008UALA06065Light · shortedFLOOR EEL LIGHTS INOP SEAT 33 TO 43 HJK. FOUND SHORTED EMERGENCY LIGHT AT 36 HJK. REPLACED LIGHT. ALL OPS NORMAL.
SDR 2008UALA06066Battery · dischargedTHE 1L FLASHLIGHT NO BLINKY. REPLACED BATTERY, OPS OKAY.SDR 2008UALA06043Light · damagedEEL STRIP DAMAGED AT SEAT 16H. REPLACED LIGHT STRIP, TEST OK.SDR 2008UALA06044Connector · damagedCREW REPORT: EMERGENCY EXIT LIGHT INOP ROW 45 ABC THRU 57ABC. DISCONNECTED CONNECTOR & FOUND DAMAGE TO SUPPLY WIRE. RECONNECTED LOOSE EMERGENCY LIGHT CONNECTOR. REPLACED BAD & WET SUPPLY WIRE FOR EMERGENCY LIGHT SYSTEM. OPS CK OK.SDR 2008UALA06045Electronic Unit · malfunctionedREPORT OF SMOKE ODOR AT 41-42 ABC. OCCURRED WHEN COVE LIGHT CAME ON AND READING LIGHT WENT OUT. ODOR DISSIPATED AFTER A WHILE. FOUND OVERHEAD DECODER ABOVE SEAT 41ABC SHORTED, DEACTIVATED OVERHEAD DECODER. NOW ROWS 41 AND 42 ABC WITH NO RESIDING LIGHTS. RSDR 2008UALA06033Pump · malfunctionedEDP HYD OVERHEAT LIGHT ILLUM EICAS MSG (L, R) PRIM HYD OVERHEAT DISPLAYED. PUMP WAS DEACTIVATED. POS 1 (01=L,02=R). SAMC TEXT: AFTER EDP SECURED SEVERAL MINUTES LATER LT QTY DROPPED TO ZERO AND EMDP WAS TURNED OFF. REPLACED LT ENG HYD PUMP AND CASE DRAIN SDR 2008UALA06038Light · inoperativeTHE 29HJ EEL LIGHT INOP. REPLACED LAMP. TEST OK.SDR 2008UALA06039Light · inoperativeTHE 15AB EEL LIGHT INOP. REPLACED LAMP. TEST OK.SDR 2008UALA06040Connector · looseLT MID LAV EEL LIGHT INOP. SECURED CONNECTOR TEST OK.SDR 2008UALA06051Panel · delaminatedRIGHT OVERWING SLIDE PANEL HAS A FOOTBALL SIZE DELAMINATION. DELAMINATED PANEL REMOVED & ROUTED TO SHOP. DOOR ASSY 416T2009-7 ON ORDER FROM BOEING. REPLACED RT OVERWING SLIDE DOOR. RIGGED AND ADJUSTED. REPLACED KEEPERS. EG EVALUATED THE FLUSHNESS CONDITION ANSDR 2008UALA06014Aspirator · damagedASPIRATOR DAMAGED & ROTOR STATOR BLADES. FOREIGN OBJECT GOT INSIDE ASPIRATOR AND DAMAGED BARREL AND ROTOR STATOR BLADES. REPLACED ASPIRATOR.SDR 2008UALA05992Connector · looseEMERGENCY LIGHT SEAT 50 RT INOP. RE-SECURED EEL CONNECTOR. OP CHECK NORMAL.SDR 2008UALA05993Light · inoperativeEMERGENCY LIGHT SEAT 3A AFT INOP. REPLACED EEL LAMP. OP CHECK NORMAL.SDR 2008UALA05994Light · inoperativeEMERGENCY CEILING LIGHT ROW 12 INOP. RELAMPED EMERGENCY LIGHT, OP CHECK NORMAL.SDR 2008UALA05995Light · inoperativeEMERGENCY LIGHT SEAT 37 LT INOP. RELAMPED, OP CHECKS NORMAL.SDR 2008UALA05996Light · inoperativeEMERGENCY LIGHT ROW 55 LT INOP. RELAMPED EMERGENCY LIGHT, OP CHECK NORMAL.SDR 2008UALA05997Light · inoperativeEMERGENCY CEILING LIGHT ROW 2 INOP. RELAMPED EMERGENCY LIGHT, OP CHECK NORMAL.SDR 2008UALA06003Guard · out of adjustEMERGENCY LIGHTS EICAS PROG TEXT: - ITEM ROLLED FORWARD. ADJUSTED GUARD ON EMERGENCY LIGHT SWITCH AT DOOR 1L. LIGHTS OPERATE NORMAL AND NO MESSAGE.SDR 2008UALA06010Nose Cowl · damagedNR 2 ENG NOSE COWL DAMAGED BY RAMP LD-2 CONTAINER. REPLACED NOSE COWL.SDR 2008UALA05984Light · damagedTHE 47H EEL LIGHTS ARE DAMAGED. REPLACED EEL LAMP. OP CHECK NORMAL.SDR 2008UALA06028Oxygen System · low pressureCOCKPIT OXYGEN QUANTITY DECREASED TO BELOW 1540 INFLIGHT. SERVICED TO 1760 AT 17DEG C. LEAK CHECKED CREW O2 BOTTLE AREA FITTINGS OK. CHECKED FLIGHT DECK O2 MASKS OKAY. INBD CREW O2 AT 1580 PSI.SDR 2008UALA05971Light · inoperativeAFT GALLEY AISLE EMERGENCY LIGHT INOP. LIGHT FOUND DEFECTIVE. REPLACED LAMP, OP CHECK OKAY.