Pratt & Whitney PW4056
Service difficulty reports · 12,595
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE engine_model_key = 'PW4056' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE engine_model_key = 'PW4056' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR CALA2014031990647Cover · out of adjustAISLE EMERGENCY GUIDANCE LIGHTS ON WHEN NOT COMMANDED TO BE ON. ROWS 54 - 60 RT SIDE ADJUSTED DOOR 1L SWITCH COVER.SDR CALA2014031990646Connector · dirtyENG 2 SQUIB TEST USING TEST SW NR 2 DOES NOT ILLUMINATE GREEN SQUIB TEST LIGHT. CLEANED & RESEATED SQUIB CONNECTORS DM228B & DM229B IAW SSM26-21-02. SQUIB TESTED NORMAL IAW AMM26-21-00.SDR CALA2014031290587Connector · unsecureSEAT 51 HJK EMERGENCY EXIT LIGHT STRIP INOPERATIVE. SECURED CONNECTOR IAW MM 33-51-12-201-C03, OPERATIONS CHECKED OK.SDR CALA2014031290597Connector · unsecureSEAT 51HJK EMERGENCY EXIT LIGHT STRIP INOPERATIVE. SECURED CONNECTOR IAW MM 33-51-12-201-C03, OPERATIONS CHECKED OK.SDR CALA2014031090580Battery · dischargedEMERGENCY LIGHT STRIPS ON INTERMITTENTLY ROW 51 TO 61. REPLACED BATTERY ASSEMBLY.SDR CALA2014031290590Altimeter · splitSPLIT ALTIMETER BETWEEN CAPTAIN & FIRST OFFICER. CAPTAIN 33000 & FIRST OFFICER 32800, ALTIMETER DISAGREE EICAS & LIGHT ON.SDR CALA2014030790549Unknown · malfunctionedON LANDING GOT EICAS OUTFLOW VLV RT. VLV HAS BEEN DEACTIVATED, CLOSED REMAINING VLV. OPERATED NORMALLY ON AUTO & MAN CB`S P6 PANEL RT. CABIN PRESS CONTROL RT ICU & PANEL 414 CABIN PRESS ICU RT ARE OPEN & SAFE TIED.SDR CALA2014030790550Chine · missingNR 2 ENG INLET COWL CHINE INBD SIDE MISSING, ATTACHING BOLTS ALSO MISSING. INSTALLED NR 2 ENG INLET COWL CHINE INBD SIDE IAW AMM 71-11-02, OKAY.SDR CALA2014030390533Light · inoperativeEMERGENCY CEILING LIGHT INOPERATIVE & LENS MISSING ROW 13. RELAMPED IAW MM 33-51-07- 201 & ORDERED LIGHT ASSEMBLY 585-1836 FOR LENS.SDR CALA2014030390534Light · inoperativeAFT SEAT EMERGENCY LIGHT INOPERATIVE SEAT 15AB. RELAMPED IAW MM 33-51-12- 201-C03.SDR CALA2014030390535Light · inoperativeLT CEILING EMERGENCY LIGHT ROW 6 INOPERATIVE. RELAMPED IAW MM 33-51-07- 201.SDR CALA2014030390528Pump · malfunctionedMOTORING RT ENG CAUSED LT SYS PRESS TO DROP TO 20 PSI, LT ELEC DEMAND PUMP SHEDS OK FOR SERVICE IAW AMM 29 -11-00 PAGE 1 ITEM 2 B ON GROUND. THE LT SYS ACMP IS INHIBITED DURING STARTING OF EITHER ENG TO REDUCE ELEC LOADS ON THE APU GENERATOR.SDR CALA2014030390531Unknown · malfunctionedEMERGENCY LIGHTS ON WHEN SWITCH IN OFF POSITION. SWITCH CYCLED, OPERATIONS CHECKED OK.SDR CALA2014030390526Ballast · inoperativeROWS 37KL & 38KL LOWER SIDEWALL LIGHT INOPERATIVE DUE TO BAD BALLAST. REPLACED BALLAST M764 ON CEILING ABOVE SEAT 38KL IAW WDM 33-21-35. SIDEWALL LIGHTS BY SEATS 37KL & 38KL OPERATIONS CHECKED NORMAL.SDR CALA2014030390529Skin · crackedNR 1 PYLON RT SIDE SKIN AT NACELLE STATION 244, ACCESS PANEL 452ER CUTOUT AFT LOWER CORNER CRACKED. REPAIRED IAW ECRA 5450-02149.SDR CALA2014030390530Skin · crackedNR 1 PYLON RT SIDE SKIN AT NACELLE STATION 244, ACCESS PANEL 482ER CUTOUT AFT LOWER CORNER CRACKED. REPAIRED IAW ECRA 5450-02150.SDR CALA2014030390532Socket · damagedELECTRICAL BURNING SMELL AT ROW 16 UPPER DECK. FOUND MELTED SOCKET AT SIDE WALL LIGHT 15A. REMOVED FLUORESCENT LIGHT BULB TO ISOLATE EVIDENCE OF SMELL, INSPECTED AREA IAW FIM 21-00-810, NO MORE SMELL NOTED. REPLACED BURNED SOCKET & RELAMPED, LIGHTS INOPERATSDR CALA2014022790491Ballast · defectiveROWS 37KL & 38KL LOWER SIDE WALL LIGHT INOPERATIVE DUE TO BAD BALLAST.SDR CALA2014022790492Light · inoperativeOVERWING EMERGENCY SLIDE LIGHTS INOPERATIVE. FOUR EACH, UPPER TWO SLIDE LIGHTS ON THE RT SIDE & LOWER TWO SLIDE LIGHTS ON THE LT. CHANGED POWER SUPPLIES FOR BOTH SIDES, NO HELP. RELAMPED BOTH SIDES, NO HELP. CHANGED NR 3 LT SLIDE LIGHT ASSEMBLY, NO HELP. SDR CALA2014022590483Valve · malfunctionedLT ENG PRV EICAS MESSAGE AFTER ENG START. REPLACED PRV IAW MM 36-11 -18 & TESTED NORMAL, STATUS MESSAGE CLEARED.SDR CALA2014022790496Unknown · smokeSMOKE IN THE CABIN, SMOKE OCCURRED AT DEPARTURE. CUSTOMERS WERE DEPLANED.SDR CALA2014022590477Battery · dischargedSLIDE TEST LIGHTS DO NOT ILLUMINATE DURING TEST. REPLACED OVERWING BATTERIES & POWER SUPPLIES IAW MM 25-65-17, SYS OPERATIONS NORMAL.SDR CALA2014022590440Aileron · damagedLT AILERON TE HAS SPEED TAPE PEELING OFF, .6 INCHES OF THE REPAIR MATERIAL MISSING & 3 INCHES PEELING OFF. NO DELAMINATION ON LOWER UPPER SURFACE OF AILERON TE. REMOVED DAMAGED CONDUCTIVE STRIP & REPLACED WITH NEW FABRICATED PART IAW AMM57-51-03P80 1. MEASURSDR CALA2014022190425Holder · burnedBUS CLASS GALLEY AFT CELLING LIGHT WITH BURNT LAMP HOLDER. REMOVED LAMPS TWO EACH CB IS PULLED & COLLARED.SDR CALA2014022190426Power Supply · inoperativeTWO EACH EMERGENCY LIGHTS INOPERATIVE AT SIDEWALL OF LAVATORY 101. REPLACED EMERGENCY POWER SUPPLY, OPERATIONS CHECKED GOOD.SDR CALA2014022190427Feeder Cable · damagedEMERGENCY LIGHTS INOPERATIVE AT AFT GALLEY CROSS AISLE. REPAIRED EMERGENCY EXIT LIGHT FEEDER CABLE GOING TO LIGHT IAW AMM 33-51-12-201 C2, OPERATIONS CHECKED GOOD.SDR CALA2014022190428Trim Panel · defectiveEMERGENCY LIGHTS AT LAVATORY 102 SIDEWALL WIRES EXPOSED. REPLACED CORNER TRIM.SDR CALA2014022190429Shroud · crackedON CM CHECK FOUND 49F, 40B, 43C, 50K, 56K, 60H & 50J DPCU SHROUD CRACKED. REPLACED & CHECKED OKSDR CALA2014021390377Priority Valve · faultyAIR RETURN TO EWR DUE TO RT BLEED LT & RT ENG PRV EICAS MESSAGE DURING CRUISE. IAW MANUAL, FLIGHT CREW SHUTDOWN ASSOCIATED PACK. NO EMERGENCY. R & R PRV VLV, PRV CONTROLLER & OVER PRESS SWITCH IAW AMM 36-11-18,36- 21-03,36-11-19.SDR CALA2014021290370Tank · leakingMAJOR FUEL SPILL 500 USG DURING REFUELING OPERATION. FUEL WAS DRAINING FROM THE SURGE TANK.SDR CALA2014021090354Connector · dirtyCAPTAIN & FIRST OFFICER`S PFD RADIO ALTITUDE READING OUT OF LIMITS. CAPTAIN`S READS 2 &, FIRST OFFICER`S READS 2. CLEANED LT TRANSMIT ANTENNA CONNECTOR & CLEANED RT TRANSMIT & RECEIVE ANTENNA CONNECTORS, NOW WITHIN TOLERANCE, GND TEST PASSED.SDR CALA2014021090355Cooling Fan · failedFAINT ODOR IN FLIGHT DECK & POSSIBLY AROUND DOOR 1R. FOLLOWED CHECKLIST 5.1 SHUTOFF TRIM AIR, NR 2 PACK & SHUTOFF BLEED ISOLATION VLVS TO ISOLATE BLEED SYSTEM AS WELL AS SHUTTING DOWN UTILITY BUSSES. FLIGHT ATTENDANT BROUGHT IN TO CONFIRM PRESENCE OF ODOR DSDR CALA2014020690318Carrier Assy · unsecureEMERGENCY EXIT LIGHTS FLICKERING ENROUTE OVER EXITS 1L 1R. SECURED REMOTE EMERGENCY LIGHT CARRIER AT 1L POSITION NOW NORMAL.SDR CALA2014020690321Flap · malfunctionedEICAS MESSAGE TE FLAP DISAGREE DISPLAYED, TE LIGHT ILLUMINATED, WHEN ANY TE FLAP POSITION SELECTED. FLAPS FAIL TO MOVE TO SELECTED POSITION.SDR CALA2014020690298Radar · failedWEATHER RADAR FAILURE WHILE ENROUTE.SDR CALA2014020690316Fireseal · damagedE2 OTBD THRUST REVERSER UPPER FWD FIRE SEAL DAMAGED. REPLACED E2 OTBD UPPER FWD FIRE SEAL IAW CMM 71-11-56, ALL CHECKED NORMAL.SDR CALA2014020690317Probe · faultyENG 2 EGT INDICATING 24F INFLIGHT. ALL OTHER ENG 2 PARAMETERS NORMAL. REPLACED EGT PROBE AT THE 1 O'CLOCK POSITION. CREW RAN ENG & EGT INDICATIONS NORMAL.SDR CALA2014020390293Light · unsecureEXIT LIGHT DISLODGED 1R. SECURED LIGHT ASSEMBLY.SDR CALA2014020390294Lead · looseENG 2 EGT INDICATION INOPERATIVE. CREW ACCOMPLISHED 2 EA STARTS BOTH WITH NO EGT INDICATION. SECURED LOOSE THERMOCOUPLE EGT LEADS AT 4:30 O'CLOCK POSITION IAW MM 77-21-02. RAN ENG INDICATION NR 2 ENG EGT CHECKED OK IAW FLIGHT CREW.SDR CALA2014020390296Radar · unknownAPPROXIMATELY 200NM SOUTH OF IAH, FLIGHT LOST WEATHER RADAR, DUE TO THUNDERSTORMS IN SOUTH AMERICA. CAPTAIN ELECTED TO AIR RETURN IAH.SDR CALA2014013190269Spindle · corrodedLT OTBD TE FLAP, INBD ACTUATOR ATTACH FITTING, SPINDLE, INNER BORE IS RUSTED & PITTED. REPLACED SPINDLE IAW 27-51 -46, OPERATIONS TESTED GOOD.SDR CALA2014013190276Warning System · activatedEICAS MESSAGE CAPTAIN`S PITOT HEAT DISPLAYED.SDR CALA2014012490227Warning System · activatedRT AUXILIARY PITOT WARNING LIGHT ON & EICAS MESSAGE.SDR CALA2014012290212Autoland Sys · malfunctionedAUTO LAND UNSATISFACTORY EXCESSIVE WING ROCKING ON SHORT FINAL. WINDS GUSTING TO 20 KTS MINIMAL CROSS WIND. UNSUCCESSFUL AUTO LAND REPORTED, PERFORMED TEST 30 IAW MM 22-00-00. ALL TESTED GOOD AT THIS TIME, OK TO CONTINUE.SDR CALA2014012490228Warning Message · activatedCREW REPORTS EICAS NR 1 ENG LOW OIL PRESS MESSAGE.SDR CALA2014012090195Tape · peelingLT AILERON TE HAS SPEED TAPE PEELING OFF. 6 INCHES OF THE REPAIR MATERIAL MISSING & 3 INCHES PEELING OFF. NO DELAMINATION ON LOWER UPPER SURFACE OF AILERON TE. ACP ECRA 5751-01179, INTERIM REPAIR LT OTBD AILERON STATIC DISCHARGE CONDUCTING STRIP.SDR CALA2014012490223Warning System · false activationCREW REPORTS HEAT PITOT STATIC LT AUXILIARY EICAS MESSAGE. NO STS MESSAGE AFTER ENG SHUT DOWN, NO MESSAGE IN CMC. ENG GND RUN ACP AT ABOVE 50%N2, NO MESSAGES. CMC GND TEST ACP, OK.SDR CALA2014012090196Circuit Card · unsecureSTATUS PAGE SHOWS HYD PRESS DEM 4, CMC SHOWED FCU L HYDIM 4 INTERFACE FAIL MESSAGE 29507. RERACKED HYDIM 4 CARD & FCU L, CYC LED FLAPS TO 30 DEG WITH NORMAL DEMAND 4 PUMP OPERATION WITH SW IN ON & AUTO POSITIONS. EICAS MESSAGE EXTINGUISHED, NR 4 HYD DEM SYS SDR CALA2014012090197Skin · corrodedFUSELAGE EXTERIOR SKIN WAS FOUND CORRODED ON INNER SURFACE BETWEEN STATION 480 - 500 & STRINGER 46R TO 47R, IN THE AREA COMMON TO THE TCAS ANTENNA. REPAIR WAS ACCOMPLISHED.SDR CALA2014012090198Stiffener · corrodedUPPER DECK LT HAND DOOR LOWER MAIN SILL STIFFENER WAS FOUND CORRODED AT STRINGER 13L FROM STATION 707 TO 714. REPAIR WAS ACCOMPLISHED IAW ECRA5310-05959.
Back to Pratt & Whitney PW4056