SDR 2008UALA02624Battery Pack · inoperativeEEL LIGHTS INOP LEFT SIDE FIRST CLASS. REPLACED BATTERY PACK. TEST OK.SDR 2008UALA02545Skin · gougedON ARRIVAL AT HKG, FOUND 3.5 DIA GOUGE AT FUSELAGE SKIN STA 2193 AND WL 200. DAMAGED AREA REPAIRED AS EVA-71460B AND INSPECTION CHECKED SATISFACTORY.SDR 2008UALA02544Light · inoperativeEEL LIGHT INOP AT G2 GALLEY SIDE WALL. REPLACED EEL LIGHT. OP CHK GOOD.SDR 2008UALA02536Controller · faultyAPU STARTED AND THEN QUIT. REPLACED CONTROLLER PER MM 49-61-05 OPS NORMALAC OK FOR SERVICE.SDR 2008UALA02499Pin · brokenEEL CABLE PIN BROKEN AT SEAT 46ABC. REPLACED CABLE ASSY. OP CHK GOOD.SDR 2008UALA02500Lamp · burned outSTAIRWAY EMERGENCY LIGHT INOP. SUSPECT FAULTY LAMP. REPLACED LAMP OPS CHECKED GOOD. AC OK FOR SERVICE.SDR 2008UALA02501Light · inoperativeRT OW EMERG LIGHT INOP 1ST AND 2ND POS. REPLACED LAMPS AND FUSES. OP CHK'D GOOD.SDR 2008UALA02502Light · brokenSEAT 58C EEL LIGHT BROKEN. REPLACED EEL LIGHT. OP CHK GOOD.SDR 2008UALA02503Switch · brokenEMERGENCY LIGHT SWITCH GUARD SPRING BROKEN AND SW ASST BROKEN AT L1 ATTENDANT SEAT HANDSET CRADLE. REPLACED SW AND GUARD OP CHK GOOD PER WDM 33-51-11, AMM33-51-00 PB 500 CONFIG 1 PARA 3. AC OK FOR SERVICE.SDR 2008UALA02523Connector · looseEMERGENCY EXIT LIGHTING TURNED ON MID FLIGHT ROWS 6-8. SUSPECT LOOSE CONNECTION. SECURED CONNECTION AT BATTERY PACK OP CHECK OK. AC OK FOR SERVICE.SDR 2008UALA02480Slide · misinstalledDOOR SLIDE 2RH SLIDE PACK COMING UNHOOKED ON FWD SECTION OF SLIDE PACK. IMPROPERLY INSTALLED DOOR SLIDE. REPLACED SLIDE PACK ASSY REF MM 25-66-01. AC OK FOR SERVICE.SDR 2008UALA02465Light · inoperativeEMERGENCY LIGHT ROW 3A AFT INOP. REPLACED LIGHT CABLE. OP CHECKS OK.SDR 2008UALA02466Light · inoperativeEMERGENCY LIGHT ROW 4A AFT INOP. RELAMPED, OP CHECKS OK.SDR 2008UALA02467Light · inoperativeEMERGENCY LIGHT ROW 32ABC INOP. REPLACED CABLE. OP CK NORMAL.SDR 2008UALA02468Battery · inoperativeDR 4 LT EMERGENCY SILL LIGHTS INOP. REPLACED BATTERY ON CHARGER. OP CK NORMAL.SDR 2008UALA02469Wire · disconnectedEMERGENCY LIGHT ROW 1J AFT INOP. FOUND LOOSE CONNECTION. SECURED CONNECTION OP CHECKED GOOD. AC OK FOR SERVICE.SDR 2008UALA02470Feeder Cable · inoperativeEMERGENCY LIGHT ROW 61 RH INOP. REPLACED EEL CABLE. OP CK NORMAL.SDR 2008UALA02471Relay · faultedGALLEY 415 ALL ELECTRICAL PANELS VERY HOT 1HR INTO FLT. SECURED GALLEY EMERGENCY POWER SWITCH PANELS COLD. FOUND FAULTY CHILLER RELAY. REPLACED RELAY OP CHECKED GOOD. AC OK FOR SERVICE.SDR 2008UALA02413Bottle · lowCREW AND PASSENGER OYXGEN LOW AT 1620 AND 1590 PSI RESPECTIVELY . SERVICED OXYGEN SYSTEM NO LEAKS NOTED. AC OK FOR SERVICE.SDR 2008UALA02414Lamp · inoperativeEEL LT INOP, ROW 58 LT. FOUND FAULTY LAMP. REPLACED LAMP OP CHECK GOOD. AC OK FOR SERVICE.SDR 2008UALA02415Connector · looseEEL LT INOP, ROW 36 RT. FOUND LOOSE CONNECTION. SECURED CONNECTION OP CHECKED OK. AC OK FOR SERVICE.SDR 2008UALA02416Lamp · inoperativeEXT EMERGENCY LT INOP: LT OVERWING 2ND AFT ASSY FWD BULB. RELAMPED. CHECKS GOOD.SDR 2008UALA02417Lamp · inoperativeEXT EMERGENCY LT INOP:RT OVERWING 3RD ASSY AFT BULB. RELAMPED. CHECKS GOOD.
SDR 2008UALA02427Apu · inoperativePRIOR TO DEPARTURE APU FAILED TO START.SDR 2008UALA02380Lamp · inoperativeSEAT 1A FWD EMERGENCY LIGHT IS INOP. REPLACED LAMP, CHKS NORMAL.SDR 2008UALA02381Light · inoperativeSEAT 46-52ABC EMERGENCY LIGHTS IS INOP. REPLACED EMERGENCY LIGHT BATTERY PACK. CHECKS NORMAL.SDR 2008UALA02382Lamp · inoperativeZONE B CEILING EMERGENCY LIGHTS 2 EACH IS INOP. RELAMPED, CHECKS NORMAL.SDR 2008UALA02383Lamp · inoperativeDOOR 5 RIGHT SILL EMERGENCY LIGHT IS INOP. REPLACED LAMP OPS CHECKED GOOD. AC OK FOR SERVICE.SDR 2008UALA02384Lamp · inoperativeFLIGHT DECK CEILING EMERGENCY LIGHT IS INOP. RELAMPED. CHECKS NORMAL.SDR 2008UALA02353Lamp · inoperativeEMERGENCY EXIT LIGHT INOP AT DOOR 4 RIGHT AFT SILL. FOUND FAULTY BULB. REPLACED LAMP OP CHECKED NORMAL. AC OK FOR SERVICE.
SDR 2008UALA02354Light · inoperativeEMERGENCY EXIT EEL LIGHT INOP AT ROW 50 RIGHT. FOUND LOOSE CONNECTION. SECURED CONNECTION LIGHT OP CHECKED GOOD. AC OK FOR SERVICE.SDR 2008UALA02357Lamp · inoperativeEMERGENCY EXIT LIGHT INOP, AT DOOR 2 LEFT FWD SILL. FOUND FAULTY BULB. REPLACED LAMP OPS CHECKED GOOD. AC OK FOR SERVICE.
SDR 2008UALA02358Power Supply · inoperativeLEFT WING EXTERIOR OVERWING EMERGENCY EXIT LIGHTS INOP, MOST FWD TWO LIGHT ASSY'S. FOUND FAULTY POWER SUPPLY. REPLACED POWER SUPPLY OVERWING LIGHTS OPS. CK. NORMAL. AC OK FOR SERVICE.SDR 2008UALA02361Connector · looseF/A REPORTS EMERGENCY LIGHTS AT FC RT SIDE SEATS ON J SIDE ARE INTERMITTENT. FOUND LOOSE CONNECTION. RECONNECTED BATTERY PACKS. AC OK FOR SERVICE.SDR 2008UALA02368Skin · crackedDAMAGE FOUND RT BS 2210 WL 200 FUSELAGE. SCRATCH MARK WITH CRACKED 3.5 INCH BY 3.5 INCH. SUSPECT GROUND EQUIPMENT DAMAGE. DAMAGED AREA REPAIRED AS EVA-71460B AND INSPECTION CHECKED SATISFACTORY. ACFT OK FOR SERVICE.SDR 2008UALA02351Lamp · inoperativeEMERGENCY EXIT LIGHT INOP, RIGHT SIDE CEILING BY LAV 101. REPLACED LAMP. OP CKS NORMAL.SDR 2008UALA02352Lamp · inoperativeEMERGENCY EXIT LIGHT INOP, ROW 26 RIGHT CEILING. REPLACED LAMP. OP CKS NORMAL.SDR 2008UALA02355Lamp · inoperativeEMERGENCY EXIT LIGHT INOP, UPPER DECK CEILING ROW 13. REPLACED LAMP. OP CKS NORMAL.SDR 2008UALA02356Lamp · inoperativeEMERGENCY EXIT LIGHT INOP UPPER DECK ROW 17 CEILING. REPLACED LAMP. OP CKS NORMAL.SDR 2008UALA02309Oxygen System · reads lowCREW OXYGEN IS LOW AT 1630 PSI, PASS OXYGEN IS GOOD AT 1760 PSI. SERVICED O2 SYSTEM TO PROPER LEVEL IAW MM12-15-08. AC OK FOR SERVICE.
SDR 2008UALA02359Power Cable · failedLAPTOP POWER OUTLET INOPERATIVE AT 6D. CREW COMMENTS, OUTLET SMOKING WITH NEW POWER CABLE. SUSPECT FAULTY RECEPTACLE. REPLACED OUTLET & CHECKED WIRING OP CHECKED GOOD. AC OK FOR SERVICE.SDR 2008UALA02360Lamp · brokenEEL LIGHT BROKEN AT SEATS 33HJK. REPLACED LAMP ASSY ON SEAT 33H. OPERATION CHECKS OKAY.SDR 2008UALA02281Panel · damagedMOST INBOARD LOWER RT LEADING EDGE PANEL INBD CORNER BROKEN OFF. APPROX. 3 INCH BY 1-2 INCH REINFORCED LEADING EDGE SECTION MISSING. REMOVED FOR REPAIR. REPAIRED BY SHOP. REINSTALLED PANEL. ACFT OK FOR SERVICE.SDR 2008UALA02308Oxygen Bottle · leakingPASSENGER OXYGEN PRESSURE READS LOW. BOTTLE LEAK AT REGULATOR.
REPLACED 2 EACH OXYGEN BOTTLES PRESSURE CHECKED GOOD. AC OK FOR SERVICE.
SDR 2008UALA02310Lamp · inoperativeEMERGENCY EXIT EEL LIGHT INOP, ACROSS DOOR 4 RIGHT LOWER WALL EEL. REPLACED LAMP OPS CHECKED GOOD. AC OK FOR SERVICE.SDR 2008UALA02311Light · inoperativeEMERGENCY EXIT LIGHT INOP, AT DOOR 4 RIGHT BUSTLE LIGHT. REPLACED BUSTLE LIGHT ASSEMBLY. OP CHECKS OK. ACFT OK FOR SERVICE.SDR 2008UALA02312Light · inoperativeEMERGENCY EXIT EEL LIGHT INOP, LEFT SIDE LOWER WALL BY LAV 111. SUSPECT FAULTY LIGHT ASSEMBLY. REPLACED LIGHT ASSEMBLY OP CHECKED GOOD.AC OK FOR SERVICE.
SDR 2008UALA02313Wire · looseEMERGENCY EXIT EEL LIGHT INOP AT SEAT 40 RIGHT. SECURED CONNECTION OP CHECKED GOOD. AC OK FOR SERVICE.SDR 2008UALA02314Wire · disconnectedEMERGENCY EXIT EEL LIGHT INOP AT SEAT 39 RIGHT. SECURED CONNECTION OP CHECKED GOOD. AC OK FOR SERVICE.SDR 2008UALA02319Oxygen System · reads lowPASSENGER O2 SHOWS 1520. SERVICED O2 SYSTEM TO FULL. AC OK FOR SERVICE.