Pratt & Whitney PW4056
Service difficulty reports · 12,595
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE engine_model_key = 'PW4056' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE engine_model_key = 'PW4056' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR 2007UALA03744Oxygen Mask · no testCAPT O2 MASK TEST NOT CORRECT. EMERGENCY P-TO TEST BUTTON STICKS OPEN. 10-19-07 REPLACED CAPTAIN'S MASK ASSY, OPERATIONAL TEST OK.SDR 2007UALA03720Lamp · inoperativeLEFT OVERWING EMERGENCY LIGHT SECOND FROM BOTTOM ONE BULB INOP & SECOND FROM TOP ONE LIGHT INOP. 10-9-07 RELAMPED BOTH POSITIONS. EEL LIGHTS OP CHECKED OK FOR SERVICE.SDR 2007UALA03721Lamp · inoperativeCEILING UPPER DECK EMERGENCY LIGHTS INOP FROM ROW 12 UP TO ROW 16. 10-9-07 RELAMPED ALL POSITIONS. RESTORED EEL LIGHTS. OK FOR SERVICE.SDR 2007UALA03784Socket · brokenTHE 'ENG 1 FIRE LP A' EICAS STATUS MSG DISPLAYED. ENG 1 FIRE LOOP A FIRE OR FAULT OUTPUT. 0-16-07 AFTER TROUBLESHOOTING & REPLACING FIRE OVERHEAT DETECTION LOGIC CARD, DETERMINED THAT PROBLEM WAS A BROKEN SOCKET IN THE FIRE LOOP CIRCUIT. W4515-104-20R SDR 2007UALA03711Connector · unsecureEEL 4E, 5E, 5J INOPERATIVE. 10-9-07 SECURED EEL FEEDER CONNECTOR. OP CHECKS OK FOR SERVICE.SDR 2007UALA03712Connector · inoperativeEEL AT DOOR 1R GALLEY SIDEWALL INOP. 10-9-07 SECURED FEEDER CONNECTOR. EEL LIGHTS TESTED OK.SDR 2007UALA03737Warning Light · illuminatedTHE 'RUD RATIO SNGL' EICAS ADVISORY MESSAGE DISPLAYED. UPPER OR LOWER RUDDER RATIO FUNCTION FAIL. 10-9-07 REPLACED WITH NEW RUDDER RATIO CHANGER ACTUATOR PER MM27-21-12. PERFORMED CMC TEST. RUDDER RATIO CHANGER PASSED AND MSG GONE. A/C RETURNED TO SERVISDR 2007UALA03710Lamp · burned outLIGHT BULB NR 1 ENGINE FIRE HANDLE BURN OUT. 10-9-07 REPLACED LAMPS IN NR 1 ENG FIRE HANDLE. TESTS OK FOR SERVICE.SDR 2007UALA03713Light · looseTHE 17B EMERGENCY STRIP FALLING OFF. 10-9-07 REINSTALLED STRIP AND EEL CHECKED NORMALLY.SDR 2007UALA03714Line · leakingUNWANTED FUEL TRANSFER PROBLEM. 10-9-07 AFTER TROUBLESHOOTING, ISOLATED PROBLEM TO CRACKED & LEAKING LT SCAVENGE SYSTEM. INSTALLED NEW SCAVENGE LINE PN 343U1023-35 REF 28-00-00-0201. SCAVENGE SYS OP CHECKS OK FOR SERVICE.SDR 2007UALA03679Light · inoperativeEEL AT 39 ABC INOPERATIVE. 10-05-07 RELAMPED EMERGENCY LIGHT. OP CHECK NORMAL.SDR 2007UALA03680Light · inoperativeEEL AT AFT GALLEY XAISLE INOP. 10-5-07 RESECURED EMERGENCY LIGHT CONNECTOR. OP CHECKED NORMAL.SDR 2007UALA03681Light · inoperativeEMERGENCY CEILING LIGHTS INOP AT ROW 13 & ROW 32L. 10-5-07 RELAMPED EMERGENCY CEILING LIGHTS IN BOTH SEAT POSITIONS. OP CHECKS NORMALLY.SDR 2007UALA03660Fuse · inoperativeLEFT OVERWING EMERGENCY EXIT LIGHTS INOP, 4 EACH. 10-11-07 REPLACED FUSES, OP CHECKED OKSDR 2007UALA03631Light · unsecureEEL STRIPS ON SEATS 6A & 2J ARE FALLING OFF. 10-11-07 REINSTALLED EEL STRIPS IN BOTH SEAT POSITIONS AND CHKD OK FOR SERVICE.SDR 2007UALA03648Lamp · inoperativeEMERGENCY LIGHT AT ROWS 38 ABC, 43 ABC & 58 ABC ARE INOPERATIVE. 10-11-07 RELAMPED EMERGENCY LIGHT AT ALL SEAT POSITIONS. ALL OP CHECKED NORMALLY.SDR 2007UALA03649Connector · unsecureEMERGENCY EXIT SIGN AFT GALLEY UPPER WALL INOP. 10-11-07 RESECURED EMERGENCY LIGHT CONNECTOR. OP CHECKS NORMALLY.SDR 2007UALA03659Light · misinstalledEMERGENCY LIGHT STRIP ON UD STAIRS NOT PROPERLY ATTACHED. 10-11-07 REINSTALLED EMERGENCY LIGHT STRIP ALONG STAIRWAY. REPLACED EEL POWER SUPPLY CABLE TO SAME. CHECKED EMERGENCY LIGHTS IN STAIRWELL. CK OKSDR 2007UALA03643Light · inoperativeEMERGENCY EXIT EEL LIGHT INOPERATIVE AT SEATS 5A AFT & 44 ABC. 10-11-07 REPLACED LIGHT ASSY IN BOTH SEAT POSITIONS. OPS. CHECKS. NORMAL. OK FOR SERVICE.SDR 2007UALA03644Feeder Cable · damagedEMERGENCY EEL LIGHT INOP. JUST AFT OF DOOR 1R LOWER WALL. 10-11-07 REPLACED POWER FEEDER. EEL LIGHT OP CHECKS NORMALLY.SDR 2007UALA03645Power Supply · inoperativeEMERGENCY EXIT CEILING LIGHTS INOP, FROM DOOR 3R THRU 4R. 10-11-07 REPLACED ELECTRICAL POWER SUPPLY UNIT, AND BATTERY, CHECKED OKSDR 2007UALA03646Lamp · inoperativeEMERGENCY EXIT LIGHT INOP, AT DOOR 4R AFT SILL LIGHT. 10-11-07 REPLACED LAMP. OP CHECKED OK.SDR 2007UALA03647Light · inoperativeEMERGENCY EXIT CEILING LIGHTS INOP, FROM DOOR 3L THRU 4L. 10-11-07 REPLACED EPSU AND BATT, OP CHECKS OK FOR SERVICE.SDR 2007UALA03632Fuse · failedEMERGENCY LIGHT INOP, RIGHT OVERWING, BOTTOM 2. 10-11-07 REPLACED MODULE FUSE. AIRCRAFT OK FOR SERVICE.SDR 2007UALA03633Light · inoperativeEMERGENCY LIGHT AT SEAT 4A AFT INOP. 10-11-07 REPLACED EEL LIGHT ASSY. SYSTEM CHECKS OK.SDR 2007UALA03615Structure · damagedFWD CARGO PIT DOOR AFT LOWER CORNER APPEARS TO BE DAMAGED.SDR 2007UALA03625Charger · faultyAPU BATTERY DOES NOT SHOW ANY CHARGING AFTER STANDBY POWER CHECK. 10-11-07 REPLACED BATTERY CHARGER. SYSTEM SHOWS CHARGING ABILITY. AIRCRAFT OK FOR SERVICE.SDR 2007UALA03566Light · inoperativeEMERGENCY CEILING LIGHT INOP 5A.SDR 2007UALA03567Light · inoperativeEEL3J FWD & 33H ARE INOP.SDR 2007UALA03586Pseu · failedCMC MSG -R BODY GEAR DOWN ALTERNATE PROX SWITCH TARGET FAIL- (PSEU) ON 3 OF LAST 5 LEGS WITH HARD FAULTS.SDR 2007UALA03572Light · inoperativeEMERGENCY EEL LIGHTS INOP AT SEATS 1J AFT & SEAT 55 ABC.SDR 2007UALA03569Light · inoperativeTHE -A- ZONE, EEL'S INOP RIGHT ROW OF SEATS.SDR 2007UALA03570Light · inoperativeTHE -D- ZONE EEL'S INOP LT ROW OF SEATS.SDR 2007UALA03571Light · inoperativeUPPER DECK FWD RT SEATS, EEL'S INOP.SDR 2007UALA03568Light · inoperativeSEATS 3J AFT & 4F AFT EEL ARE INOPERATIVE. RELAMPED, OPS CHECK OKAY.SDR 2007UALA03453Connector · unsecureEEL LIGHT AISLE STRIPS AT ROWS 6-8 TURN OFF AND ON AT RANDOM. SECURED STRIPS CONNECTOR & CHECKED OK.SDR 2007UALA03454Fuse · failedEMERGENCY LIGHTS INOP: LEFT OVERWING 2 FWD ASSY'S. REPLACED FUSE IN EMERGENCY POWER SUPPLY UNIT, CHECKS OK.SDR 2007UALA03455Lamp · missingEEL INOP: ROW 17L 1EA MISSING. REPLACED LAMP.SDR 2007UALA03456Lamp · inoperativeEEL INOP: SEAT 44 HJK. REPLACED LAMP.SDR 2007UALA03457Loop · faultyEXISTING ACTIVE FAULT: FWD CARGO 1 LOOP A FAIL. MNT MSG 26160. RESET SYST, RETEST OF CMC GROUND TEST. SYSTEM PASSED. NO EXISTING FAULTS, NO STATUS MSG, FIRE TEST OKSDR 2007UALA03480Slide · faultyDOOR 5 RIGHT SLIDE CAME APART. DID NOT DEPLOYED.SDR 2007UALA03481Bottle · faultyDOOR 5 RIGHT SLIDE CAME OFF. DOOR ASSIST BOTTLE NEEDS REPLACEMENT.SDR 2007UALA03431Connector · unsecureEMERGENCY LIGHT ROW 33 LEFT INOP. RESECURED EMERGENCY LIGHT CONNECTION. OP CHECKS NORMALLY.SDR 2007UALA03432Lamp · inoperativeEMERGENCY LIGHT ROW 52 RIGHT INOP. RELAMPED EMERGENCY LIGHT. OP CHECKS NORMALLY.SDR 2007UALA03433Lamp · inoperativeEMERGENCY LIGHT AFT GALLEY RIGHT WALL INOP. RELAMPED EMERGENCY LIGHT. OP CHECKS NORMALLY.SDR 2007UALA03421Lamp · inoperativeUPPER DECK EMERGENCY EXIT CEILING LIGHT AT ROW 13 & CEILING LIGHT AT ROW 2 ARE INOPERATIVE. RELAMPED CEILING LIGHTS IN BOTH POSITIONS. OP CHECKS. NORMALLY.SDR 2007UALA03422Lamp · inoperativeEMERGENCY EXIT EEL LIGHTS INOP AT SEATS 3J AFT & 5E AFT. REPLACED LAMPS IN EEL FOR BOTH SEAT POSITIONS. BOTH CHECK OK FOR SERVICE.SDR 2007UALA03423Wire · damagedEMERGENCY EXIT EEL LIGHT INOP AT SEAT 2A BOTH LIGHT ASSY'S. REPAIRED WIRES AT CONNECTOR. OP CHECKS OK FOR SERVICE.SDR 2007UALA03424Power Supply · inoperativeRIGHT HAND EXTERIOR OVERWING EMERGENCY EXIT LIGHTS INOP 2 EA FWD LIGHT ASSY'S. REPLACED POWER SUPPLY. OP CHECKS NORMALLY.SDR 2007UALA03425Light · inoperativeEMERGENCY EXIT EEL LIGHT INOP AT SEAT 32 ABC. REPLACED LIGHT ASSY. OPERATES NORMALLY.
Back to Pratt & Whitney PW4056