Pratt & Whitney PW4056
Service difficulty reports · 12,595
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE engine_model_key = 'PW4056' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE engine_model_key = 'PW4056' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR 2002UALA00352Battery · dischargedFIRST CLASS LEFT SIDE ALL EEL LIGHTS DO NOT COME ON. REPLACED BATTERY, OPS CHECK GOOD.SDR 2002UALA00357Light · inoperativeSEAT 4E, 4F, 4J, & 5J AFT EEL ELEMENT IN SEAT IS INOP. REPLACED LIGHT ASSEMBLIES.SDR 2002UALA00358Light · inoperativeEEL AT SEAT 52 ABC IS INOP. REPLACED LIGHT ASSEMBLY.SDR 2002UALA00359Light · inoperativeEXTERIOR EMERGENCY LIGHT ON RIGHT SIDE 2ND FROM THE FRONT THE AFT BULB IS INOP. REPLACED LAMP.SDR 2002UALA00361Connector · looseALL STAIRCASE EEL LIGHTS ARE INOP. SECURED ELEC CONN AT THE TOP OF STAIRCASE.SDR 2002UALA00362Pin · brokenAFT EEL LIGHT SEAT 4F IS INOP BECAUSE THE HARNESS THAT IT CONNECTS UP WITH HAS BROKEN PIN ON ITS CONNECTOR. REPAIRED AND REINSTALLED CONNECTOR. TEST OK.SDR 2002UALA00346Light · inoperativeROW 22 LEFT SIDE EMERGENCY CEILING LIGHT IS INOP. REPLACED LAMP.SDR 2002UALA00344Connector · contaminatedBOTH SIDES SEAT AISLE EEL LIGHTS INOP IN B-ZONE. CLEANED WATER FROM SIDEWALL EEL LIGHTS CONNECTIONS AND REINSTALLED. OPS CHECKS OK.SDR 2002UALA00345Light · inoperativeDOOR 2 LEFT EMERGENCY LIGHT ON UPPER BUSTLE IS INOP. REPLACED LAMP.SDR 2002UALA00347Light · inoperativeSEAT 5A AFT EEL LIGHT ELEMENT INOP. REPAIRED EEL.SDR 2002UALA00348Light · inoperativeUPPER DECK EMERGENCY CEILING LIGHTS AT ROW S 13 & 17 INOP. REPLACED LAMP.SDR 2002UALA00349Light · inoperativeAFT EEL LIGHT IN CTR UPPER DECK CEILING PANEL INOP. REPLACED LAMP.SDR 2002UALA00350Light · inoperativeDOOR 1 RIGHT AND 4 RIGHT AFT DOOR SILL EEL LIGHTS INOP. REPLACED LAMP.SDR 2002UALA00351Light · inoperativeTHE FOLLOWING EEL CEILING LIGHTS INOP ROW 39 RIGHT SIDE, ROW 23 RIGHT SIDE, ABOVE LAV 102. REPLACED LAMP.SDR AUS20020154Fan Blade · separated(AUS) NR 3 ENGINE FAN BLADE SEPARATED. ASSOCIATED DAMAGE TO ENGINE. AIRCRAFT IS BRITISH REGISTERED.SDR 2002UALA00328Connector · contaminatedALL SEAT AISLE EEL LIGHTS INOP IN B-ZONE (BOTH SIDES). THIS DISCREPANCY WAS FOUND DURING THE COURSE OF A MAINTENANCE CHECK, (B-CK). CLEANED WATER FROM SIDEWALL EEL LIGHTS CONNECTIONS AND REINSTALLED. OPS CHECKS OK.SDR S02472004EngineB18271 DUE TO #1 ENG VIBRATION HIGH & EGT OVER LIMIT AFT 3 HRS DEPARTED FM BMM, #1ENG SHUT DOWN IN FLT & RETURN TO BKK.C/A:1.INITIAL INVESTIGATION:GROUND CHECK FOUND #4 BEARING PRESS TUBE BROKEN AT 7:00 CLOCK AND EDP PRESS OUTLET B-NUT LOOSEN. 2.INITAL ACTION:SDR 2002UALA00327Light · inoperativeFORWARD ASSEMBLY (RIGHT SIDE) EXTERIOR EMERGENCY LIGHT (FORWARD BULB) IS INOP. THIS DISCREPANCY WAS FOUND DURING THE COURSE OF A MAINTENANCE CHECK, (B-CK). RELAMPED.SDR 2002UALA00329Light · inoperativeOVERWING EMERGENCY ESCAPE LIGHTS THE FORWARD BULB IN THE MOST AFT ASSEMBLY ON THE RIGHT HAND SIDE IS INOP. THIS DISCREPANCY WAS FOUND DURING THE COURSE OF A MAINTENANCE CHECK, (B-CK). RELAMPED.SDR 2002UALA00726Compressor · faultyNR 3 ENGINE SURGED 3 TIMES DURING TAKEOFF WITH FLAMES PER CREW. CREW WRITE UP DURING T/O LAX NR 3 ENGINE VIBRATED WITH LOUD 3 TIME POPS. ENGINE EXPERIENCED A GROUP 3 SURGE (EXCESSIVE BLADE TIP CLEARANCES IN HPC REAR STAGES). ENGINE WAS REMOVED FOR COMPRESSOSDR 2002UALA00308Light · burnedBURNING PLASTIC SMELL REPORTED BY F/A IN UPPER DECK DURING DESCENT. FOUND AND REPLACED LAMPS IN FSB-NS SIGNS IN UPPER DECK THAT WERE BLACKENED-BURNT.SDR 2002UALA00309Light · inoperativeEMERGENCY CEILING LIGHTS ON RIGHT HAND AISLE AT ROW 8, 24, 48, & 53 ARE INOP. THIS DISCREPANCY WAS FOUND DURING THE COURSE OF A MAINTENANCE CHECK, (B-CK). RELAMPED CEILING LIGHTS.SDR 2002UALA00310Light · inoperativeEMERGENCY CEILING LIGHT AT UPPER DECK ROW 13 IS INOP. FOUND DURING MAINTENANCE CHECK, (B-CK). RELAMPED CEILING LIGHTS.SDR 2002UALA00311Light · inoperativeEMERGENCY CEILING LIGHT AT RIGHT HAND AISLE BETWEEN LAV 102 AND CLOSET IS INOP. THIS DISCREPANCY WAS FOUND DURING THE COURSE OF A MAINTENANCE CHECK, (B-CK). RELAMPED CEILING LIGHTS.SDR 2002UALA00312Wire Harness · damagedUPPER DECK STAIR PATHWAY LIGHTING (GOING FROM LOWER DECK TO UPPER DECK) ARE INOP AT 4TH AND 6TH FROM THE TOP POSITIONS. THIS DISCREPANCY WAS FOUND DURING THE COURSE OF A MAINTENANCE CHECK, (B-CK). REPAIRED OPEN HARNESS.SDR 2002UALA00313Light · inoperativeEMERGENCY CEILING LIGHTS ON LEFT HAND AISLE AT ROW 24, 34 & 61 ARE INOP. THIS DISCREPANCY WAS FOUND DURING THE COURSE OF A MAINTENANCE CHECK, (B-CK). RELAMPED CEILING LIGHTS.SDR 2002UALA00314Light · inoperativeEMERGENCY EXIT LIGHT INOP AT UPPER DECK STAIR CEILING. THIS DISCREPANCY WAS FOUND DURING THE COURSE OF A MAINTENANCE CHECK, (B-CK). RELAMPED WITH P/N 1317 AND TESTED OK.SDR 2002UALA00315Light · inoperativeEMERGENCY EXIT LIGHT INOP IN CENTER AFT UPPER DECK CEILING PANEL. THIS DISCREPANCY WAS FOUND DURING THE COURSE OF A MAINTENANCE CHECK, (B-CK). RELAMPED WITH P/N 1317 AND TESTED OK.SDR 2002UALA00145Control Handle · malfunctionedRETURNED TO THE FIELD DUE TO LANDING GEAR HANDLE WOULD NOT RAISE PAST LEVER LOCK AFTER TAKEOFF. NO EICAS MESSAGES APPEARED.SDR ANCF200200003Indicator · malfunctionedDURING FLIGHT WITH NORMAL FUEL FLOW THE RT TANK SHOWED DIFFERENCE BETWEEN TOTAL FUEL QTY AND FUEL QTY OF FMC ADDITIONALLY, WAS PRESENTED FUEL DISAGREE PROG 2, AND FUEL CONFIGURATION WAS PRESENT TWICE. CREW PROCEEDED TO RETURN TO EDR. CORRECTIVE ACTION: PERSDR 2002UALA00144Light · inoperativeEEL AT SEAT 34 HJK INOP. REPLACED LIGHT ASSEMBLY.SDR 2002UALA00146Hydraulic Line · collapsedRIGHT WING GEAR WOULD NOT RETRACT AFTER TAKEOFF. CYCLED GEAR, NO HELP. WING GEAR DID NOT RETRACT DUE TO LOW SYSTEM 4 PRESSURE. NR 4 HYDRAULIC SYSTEM FOUND CONTAMINATED DUE TO EDP OVERHEAT CONDITION. OVERHEAT CONDITION BELIEVED DUE TO PARTIALLY COLLAPSED EDSDR 2002UALA00128Light · inoperativeSEAT 53C EEL DAMAGED, INOP. REPLACED IN SEAT EEL STRIP. OPS CHECK GOOD.SDR 2002UALA00114Light · looseEEL LIGHT STRIP AT SEAT 5A IS COMING APART. SECURED EEL LIGHT.SDR 2002UALA00115Socket · corrodedEXTERIOR EMERGENCY LIGHT OVERWING RIGHT HAND SIDE THIRD ASSEMBLY AFT HAS FORWARD BULB INOP. REMOVED CORROSION INSIDE LAMP SOCKET, OPERATION CHECKS GOOD.SDR 2002UALA00117Light · inoperativeFORWARD EMERGENCY LIGHT AT DOOR 1R SILL INOP. RELAMPED, OPS CHECKS OK.SDR 2002UALA00119Connector · contaminatedEEL STRIP ON WALL JUST AFT OF COCKPIT DOOR INOP. CLEANED WATER FROM CONNECTION AND RESECURED. OPS CHECKS OK.SDR 2002UALA00094Battery Pack · dischargedEEL LIGHTING FROM SEATS 55ABC TO AFT LAV BULKHEAD LEFT HAND SIDE, INCLUDING DOOR 5L BLUE EEL SIGN ARE VERY DIM. REPLACED BATTERY PACK.SDR 2002UALA00093Light · inoperativeEEL LAMP IS INOP AT SEAT 58C. RELAMPED EEL LIGHT ASSY. OPS CHECKED OK.SDR 2002UALA00023Skin · crackedFORWARD CARGO DOOR AFT LOWER SKIN WAS CRACKED. MAJOR REPAIR WAS ACCOMPLISHED.SDR 2002UALA00020Element · looseEMERGENCY LIGHT STRIP AFT ELEMENT IS OUT AT SEAT 5A AND F. FWD ELEMENT IS LOOSE, REPAIRED.SDR 2002UALA00021Power Supply · dischargedDOOR 3 LEFT AFT GREEN EMERGENCY EXIT LIGHT INOP. REPLACED PWR SUPPLY ABOVE DOOR 3 LEFT. DOOR 3 LEFT AFT GRN EXIT LIGHT AND GALLEY WALL LIGHT ACROSS FROM DOOR 3 LEFT NOW WORKING.SDR 2002UALA00019Light · inoperativeEEL LIGHT INOP AT AFT GALLEY LEFT HAND NEXT TO LAV 117. REPLACED EEL STRIP NEXT TO LAV 117.SDR 2002UALA00022Fuse · blownBOTH FORWARD EXTERIOR OVERWING EMERGENCY LIGHT ASSEMBLY'S INOP ON LEFT HAND SIDE. REPLACED FUSE IN POWER SUPPLY.SDR 2001UALA02478Skin · crackedTHE TAIL CONE LOWER SKIN HAS CRACK AND DENT JUST AFT OF THE APU COMPARTMENT. MAJOR REPAIR ACCOMPLISHED INSTALLED REPAIR DOUBLER.SDR 2001UALA02427Stringer · damagedRIGHT HAND FUSELAGE STATION 760-1780 STRINGER 36 HAS REPAIR DOUBLER INSTALLED WITH INSUFFICIENT CIRCUMFERENTIAL FASTENER ROWS. MAJOR REPAIR ACCOMPLISHED. REPLACED DOUBLER.SDR 2001UALA02429Battery Pack · dischargedEMERGENCY LIGHTS FROM ROW 55 TO DOOR 5 RIGHT WILL NOT TURN OFF. REPLACED DOOR 4 RT AND 5 RT EMERGENCY LIGHT BATTERY PACKS.SDR 2001UALA02404Floorbeam · damagedSTATION 1700 FLOORBEAM UPPER CHORD HAS EXCESSIVE MATERIAL AT RBL 44. ANGLES AND STIFFENERS ANGLES INSTALLED.SDR S01430038Terminal · brokenB-18203 WINDOW HEAT IL MSG SHOW DUE TO POWER LINE BROKEN AND BURNED. C/A: 1. GROUND CHECK FOUND A15 CONTROL SENSOR WIRING BROKEN. 2. WIRING (P/N:CWC01-1210) REPLACED AND CMC BITE TEST PASSED. 3. GROUND CHECK MSG DISAPPEARED. 4. ACCOMPLISHMENT OF EO 744-30-SDR 2001UALA02357Skin · puncturedTHE RIGHT HAND EXTERIOR SKIN WAS PUNCTURED JUST AFT OF DOOR 5R. BODY STATION 2290, NEAR STRINGER 21R. MAJOR REPAIR ACCOMPLISHED, A DOUBLER REPAIR WAS INSTALLED.
Back to Pratt & Whitney PW4056