SDR UALA2012102906200Failsafe · crackedPER ROUTINE TASK CARD 82400315, FOUND STA 1200 FAIL SAFE CHORD FASTENER HOLE CRACKED. CHORD REPAIRED PER SRM 51-71-11 REV 83 AND 53-10-99 PG 201 REV 156.SDR UALA2012102906201Structure · damagedNR 4 NACELLE O/B SIDE DOUBLER REPAIR AT NAC STA 224-234. MANUFACTURED AND INSTALLED REPAIR PARTS IAW SRM 54-50-01. RII ACCOMPLISHED.SDR UALA2012102906202Frame · crackedPERFORMED J-C 824003015 TENSION TIES INSPECTED FOUND STA 1200 RT FRAME TWO FASTENER HOLES CRACKED. REMOVED AND REPLACED NEW FRAME PER SRM 51-40-02 GEN REV 83.SDR UALA2012102906203Frame · crackedPERFORM J-C 824003015 TENSION TIES INSPECT FOUND ONE FASTENER HOLE CRACK ON STA 1120 LEFT FRAME. REMOVED AND REPLACED FRAME PER SRM.SDR UALA2012102906204Frame · crackedPERFORM J-C 824003015 TENSION TIES INSPECT FOUND STA 1120 RT FRAME TWO FASTENERS HOLES CRACK. REMOVED AND REPLACED FRAME PER SRM.SDR UALA2012102906205Shear Web · crackedWHILE PERFORMING ROUTINE TASK CARD 824003015 TENSION TIE INSPECT FOUND CRACK AT STA 1120 LEFT SHEAR WEB. REPAIRED PER AMM 53-10-99 REV 156.SDR UALA2012102906206Frame · crackedPERFORMED J-C 824003015 TENSION TIES INSPECT FOUND STA 1160 LEFT FRAME ONE FASTENER HOLE CRACK. MAJOR REPAIR ACCOMPLISHED: REMOVED AND REPLACED FRAME PER SRM 51-40-02 GEN REV 83.SDR UALA2012102906207Tension Tie · crackedPERFORM J-C 824003015 TENSION TIES INSPECT FOUND STA 1120 LEFT FORWARD TENSION TIES ONE FASTENER HOLE CRACKED. REMOVED DAMAGE, MADE REPAIR PARTS AND INSTALL PER SRM 53-40-30 R1 REV 83. RII ACCOMPLISHED.SDR UALA2012102906208Frame · crackedWHILE PERFORMING ROUTINE TASK CARD 824003015 TENSION TIE INSPECTION FOUND ONE FASTENER HOLE CRACKED AT STA 1160 RIGHT SIDE. CRACK REPAIRED BY REPLACING FRAME PER 51-40-02 REV 83.SDR UALA2012102906209Frame · damagedBS 1265 RIGHT FRAME INNER CHORD AND WEB INTERCOSTALS SPLICE ANGLES REPAIRED IAW ECRA 5312-01051. REPAIRS ACP PER ECRA.SDR UALA2012102906212Web · crackedBS 140 TO 160 & RBL 10 TO RBL 50 CRACKS WERE FOUND ON THE WEB, P/N 65B01870-60 OF FLOOR TO SKIN SHEAR TIE INSTALLATION 65B01870-231. REPAIRS ACP IAW ECRA 5320-02104.SDR UALA2012102906213Door Frame · crackedNR 4 LEFT MED FRAME CRACK REPAIRED IAW SRM 52-10-02.SDR UALA2012102906214Tension Tie · damagedSTA 1120 RIGHT FORWARD TENSION TIE REPAIR IAW SRM 53-40-30.SDR UALA2012102906215Tension Tie · crackedSTA 1200 LEFT FORWARD TENSION TIE ONE EACH FASTENER HOLE CRACK REPAIRED IAW SRM 53-40-30 REPAIR 1.SDR UALA2012102906216Tension Tie · crackedPERFORM J-C 824003015 TENSION TIES INSPECT FOUND STA 1120 LEFT FORWARD TENSION TIES ONE FASTENER HOLE CRACKED. REPAIRED PER SRM 53-40-30 REPAIR 1.SDR UALA2012102906217Door Frame · crackedNR 2 LEFT MED FORWARD LOWER CORNER FRAME CRACK REPAIRED IAW SRM. RII ACCOMPLISHED.SDR UALA2012102906230Fan · faultyGRINDING NOISE IN CABIN, RTFL. REPLACED BULK CARGO VENTILATION FAN, OPS CHECKED GOOD. PART AVAILABLE. VALVE WAS SHIPPED FROM DENVER.SDR UALA2012102906234Thermostat · unsecureCOCKPIT WINDOW 2R FREEZING OVER. HEAT ELEMENT IS BROKEN AND NOT ATTACHED. FOUND CONTROL THERMOSTAT DETACHED FROM RETAINER SPRING. SECURED THERMOSTAT ON POSITION AND ACP'D WINDOW HEAT TEST PER MM. NO FAULT FOUND. ALSO ACP'D 2R WINDOW INSPECTION PER MM. NOSDR UALA2012103106260Oxygen Mask · missingDOOR 3L O2 MASK MISSING. MASK REPLACED.SDR UALA2012103106270Module · failedNR 4 ENGINE SQUIB TEST FAILS TEST NR 2 REF NR 3 SVC. DEFERRED DUE TIME, COMPLIED WITH MEL 2621ZF. INTEGRITY TEST OK. REPLACED SQUIB TEST MODULE PER AMM. TESTS NORMAL.SDR UALA2012102906187Light · brokenTHE 49H SEAT MOUNTED EEL BROKEN. REPLACED EEL AT SEAT 49H PER MM, OPS CHECKED OKAY.SDR UALA2012102906177Light · looseEEL LIGHT AT SEAT 40HJK LOOSE. RELAMPED OK.SDR UALA2012102906178Light · faultyEMERGENCY CEILING LIGHT IN AT AFT CREW REST VERY DIM. REPLACED LAMPS.SDR UALA2012102906181Light · inoperativeEMERGENCY CEILING LIGHT IN FLIGHT DECK INOPERATIVE. RELAMPED, OPS NORMAL.SDR UALA2012102906182Light · inoperativeEEL LIGHT AT 57ABC INOPERATIVE. RELAMPED, OK.SDR UALA2012102906183Light · inoperativeEEL LIGHT AT 45ABC INOPERATIVE. RELAMPED, OKAY.SDR UALA2012102906184Light · inoperativeEEL LIGHT AT SEAT 45HJK INOPERATIVE. RELAMPED OK.SDR UALA2012102906179Light · inoperativeEEL LIGHT BETWEEN LAVS 111 AND 112 INOPERATIVE. REPLACED EEL LAMP AND REPAIRED EEL.SDR UALA2012102906180Light · inoperativeEMERGENCY LIGHT LOWER RIGHT CROSS AISLE AT DOOR 2 INOPERATIVE. RELAMPED AND REPLACED LENS OPS NORMAL.SDR UALA2012102606150Plate · crackedSTA 1120 LT TENSION TIE STEEL PLATE ONE FASTENER HOLE CRACKED. REMOVED AND REPLACED PLATE IAW SRM.SDR UALA2012102606159Shutoff Valve · faultyCREW REPORT: L ENGINE HPSOV AND LT ENGINE BLEED LIGHT LIGHT ON IDLE POWER ADVANCING POWER CLEARED LIGHT. INOP'D LEFT ENGINE HI STAGE VALVE PER MEL3611Q PROCEDURES. REPLACED NR 1 ENG HPSOV.SDR UALA2012102906222Generator · faultyDURING PUSHBACK, APU GENERATOR DROPPED OFF LINE. GEN COMES ON LINE FOR 5 SECONDS THEN DROPS OFF LINE. TROUBLESHOT AND FOUND OPEN FIELD ON T2-N,T-3-N. REMOVED AND REPLACED APU GENERATOR PER BOEING 767-300 AMM 24-21-01. OPS AND LEAK CHECKS GOOD.SDR UALA2012102506142Light · brokenDOOR 1L LOWER EMERGENCY LIGHT ON LAV IS BROKEN OFF. SPLICED ONE WIRE AND EPOXY SMALL EXIT SIGN ON LAV, TRIM PIECE WOULD NOT STAY ON, ADDED SMALL PIECE OF INVISIBLE TAPE TO TRIP PIECE, OP CHECKS GOOD ON GROUND.SDR UALA2012103006237Light · looseEMERGENCY LIGHT ON THE BOTTOM PANEL MAIN DECK BUSINESS CLASS ON THE SIDE OF LAV 102 LOOSE. SECURED BOTTOM EMERGENCY LIGHT AT LAV 102.SDR UALA2012102606160Pin · faultyNR 2 ENGINE STUCK IN FULL REVERSE. REV ISLN LIGHT ILLUMINATED. EICAS 'REV' DISPLAYED GREEN. FORWARD THRUST LEVERS COULD NOT BE ADVANCED. FRM CODE 78 34 08 CREW COMMENTS: R REV ISLN VAL ON EICAS. TRY TO OPERATE THRUST REVERSER, STUCK IN OPEN POS. AFTER TRSDR UALA2012102506138Light · looseEMERGENCY LIGHT ON THE BOTTOM PNL MAIN DECK BUSINESS CLASS ON THE SIDE OF LAV 102 LOOSE. SECURED BOTTOM EMERGENCY LIGHT AT LAV 102.SDR UALA2012102506139Light · brokenDOOR 1L LOWER EMERGENCY LIGHT ON LAV IS BROKEN OFF. SPLICED ONE WIRE AND EPOXY SMALL EXIT SIGN ON LAV, TRIM PIECE WOULD NOT STAY ON, ADDED SMALL PIECE OF INVISIBLE TAPE TO TRIP PIECE, OP CHECKS GOOD ON GROUND.SDR UALA2012102506109Skin · damagedBS 460-480 BETWEEN S14R & S16R ALTERNATE REPAIRS ACP IAW ECRA 5331-01642.SDR UALA2012102506110Light · inoperativeEMERGENCY LIGHT INOP: CREW REST CEILING. REPLACED LAMPS AND REPAIRED ASSY LEN.SDR UALA2012102506108Skin · damagedBS 460-480 BETWEEN S14L & S15L ALTERNATE REPAIRS ACP IAW ECRA 5331-01643.SDR UALA2012102506111Battery Pack · dischargedEMERGENCY LIGHTT INOP: DOOR 5 LEFT SLIDE ILLUM. REPLACED BATTERY PACKS.SDR UALA2012102506115Light · unsecureEMERGENCY WALL EEL INOP: MID GLY LEFT WALL. SECURED LOOSE EEL LIGHT.SDR UALA2012102506116Connector · defectiveEMERGENCY WALL EEL INOP: AFT WALL CROSS AISLE LEFT SIDE. REPAIRED DEFECTIVE CONNECTOR AND REPLACED EEL LAMP.SDR UALA2012102506112Light · inoperativeEMERGENCY LIGHT INOP: DOOR 5 RIGHT SLIDE ILLUM. REPLACED DEFECTIVE LAMPS.SDR UALA2012102506113Light · inoperativeEMERGENCY LIGHT INOP: SEAT 53 RIGHT EEL. REPLACED DEFECTIVE LAMPS.SDR UALA2012102506114Light · inoperativeEMERGENCY EXIT SIGN INOP: DOOR 4 RIGHT LWR EEL EXIT. REPLACED DEFECTIVE LAMPS.SDR UALA2012102506136Light · brokenON CM 8401 FOUND DOOR 5L EMERGENCY EXIT LIGHT BROKEN. REPLACED EMERGENCY EXIT LIGHT AND OPS CHECK OK.SDR UALA2012102506131Indicator · faultySTANDBY ALTIMETER IS 360 FEET HIGH AT FL320. REPLACED STANDBY AIRSPEED INDICATOR AND PERFORMED PITOT STATIC CHECK.SDR UALA2012102306066Cable · unsecureBEFORE PUSHBACK FLT ATTENDANT REPORT AFT GALLEY ONE PIGTAIL CABLE INOP. RE-SECURED CABLE OKAY.SDR UALA2012102206016Light · inoperativeEEL LIGHT INOP AT DOOR 2 GALLEY CEILING. RELAMPED, OPS NORMAL.
Back to Pratt & Whitney PW4056