Pratt & Whitney PW4056
Service difficulty reports · 12,595
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE engine_model_key = 'PW4056' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE engine_model_key = 'PW4056' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR UALA2012062203306Controller · faultyAIRCRAFT HAVING TROUBLE ACCEPTING FUEL. MANIFOLD NOT OPENING. REPLACED NR 3 REFUEL VALVE CONTROLLER.SDR UALA2012062203309Light · inoperativeUPPER DECK CEILING EMERGENCY LIGHT NEAR 15AB IS INOP. RELAMPED UPPER DECK CEILING EMERGENCY LAMP NEAR 15AB. CHECKS NORMAL.SDR UALA2012062203310Light · inoperativeUPPER DECK SEAT EMERGENCY LIGHT 13AB IS INOP. RELAMPED UPPER DECK SEAT EMERGENCY LAMP, CHECKS NORMAL.SDR UALA2012062203311Light · inoperativeUPPER DECK SEAT EMERGENCY LIGHT 14AB IS INOP. RELAMPED UPPER DECK SEAT EMERGENCY LAMP, CHECKS NORMAL.SDR UALA2012062203312Light · inoperativeSTAIRWAY CEILING EMERGENCY LIGHT ONE LAMP INOP. RELAMPED ONE EACH CEILING LAMP 1317. CHECKS NORMAL.SDR UALA2012062203313Light · inoperativeSEAT EMERGENCY LIGHT 19A IS INOP. RELAMPED SEAT EMERGENCY LAMP, CHECKS NORMAL.SDR UALA2012062203314Wire Harness · disconnectedSEAT EMERGENCY LIGHT 60ABC IS INOP. FOUNDED DISCONNECTED. RECONNECTED. SECURED HARNESS. CHECKS NORMAL.SDR UALA2012062203315Light · brokenEMERGENCY EXIT STRIP LIGHTT ON 2H BROKEN OFF. TAPED DEFERRED STICKER OVER MISSING LIGHT AREA. REPLACED EEL STRIP, OPS CHECK OK.SDR UALA2012062203307Wire Harness · disconnectedSEAT EMERGENCY LIGHT 48HJK IS INOP. FOUND DISCONNECTED. RECONNECTED. SECURED HARNESS. CHECKS NORMAL.SDR UALA2012062203308Light · inoperativeSEAT EMERGENCY LIGHT 25 HJK IS INOP. REPLACED SEAT EMERGENCY LAMP 7867-1 AND SECURED. CHECKS NORMAL.SDR UALA2012062203302Light · unsecureSEAT 6H HAS PLACARD HANGING IN THE AISLE. AISLE SEAT 6H EEL STRIP NEEDS ADHESIVE OR REPLACE. UNABLE TO SECURE. REMOVE EEL STRIP. FIRST AVAIL, NEED 5.5 INCH EEL STRIP. REPLACED SEAT MOUNTED EEL LIGHT AT SEAT 6H FWD LIGHT, OPS CHECK OK.SDR UALA2012062203316Light · missingEEL LIGHT MISSING OFF OF SEAT 23AB. SECURED LIGHT TO SEAT.SDR UALA2012062203356Light · inoperativeCABIN EEL IS INOP AT ROWS 1-6 ON RIGHT SIDE OF CABIN. FOUND FWD EEL AISLE STRIP FWD OF SEAT 1HJ SHORTED DISC AT SEAT 1HJ SEAT ROWS 1HJ THRU 6HJ OPS OK. REPAIRED SHORTED AREA, REINSTALLED CONNECTION AT 1HJ AND OP CKD GOOD.SDR UALA2012062203336Connector · unsecureEEL STRIP INOP ON FLOOR IN FRONT OF RIGHT OVERWING LAV AND ON SEAT 26HJ (ONLY). SECURED CONNECTOR UNDER SEAT 26HJ & SECURED EEL STRIP CONNECTOR UNDER SEAT 19HJ WHICH FIXED STRIP IN FRONT OF LAV, OPS OK.SDR UALA2012062203334Connector · looseEMERGENCY LIGHT ROW 51HJK INOP. FOUND CONNECTOR LOOSE, RECONNECTED AND OP CHECKED NORMAL.SDR UALA2012062203303Light · missingSEAT 4B AFT SEAT MOUNTED EEL LIGHT MISSING. REPLACED SEAT MOUNTED EEL LIGHT AT SEAT 4B AFT LIGHT, OPS CHECK OK. COMPLETED IDT INSPECTION AND OPS CHECK OKAY.SDR UALA2012062203304Light · inoperativeSEAT ROW 4 RIGHT SEAT MOUNTED EEL INOP. REPLACED EEL LIGHT AT SEAT ROW 4 RIGHT AFT SEAT MOUNTED LIGHT, OPS CHECK OK. COMPLETED IDT INSPECTION AND OPS CHECK OKAY.SDR UALA2012062203333Cable · defectivePIGTAIL P43 SPARKED WHEN IT WAS PLUGGED INTO THE GALLEY CART MODULE. DEACTIVATED FOOD CART CONTROLLER N43, BREAKER PULLED AND WRAPPED WITH DF STICKER. COLLARED BREAKER AND SECURED PIGTAIL END. REPLACED THE PIGTAIL P43 NEW TECH CART CABLE PER AMM. TESTED THSDR UALA2012061503279Skin · corrodedSTA 990-1000 S45R-S46R EXT FUSE SKIN DOUBLER CORROSION AT WATER TANK FILL VALVE. MAJOR REPAIR ACCOMPLISHED. REMOVED DAMAGE. MFG NEW DOUBLER PER DRAWING 65B09637-1 AND INSTALLED. NON ROUTINE 0290082.SDR UALA2012062203318Cable · sparksPIGTAIL P43 SPARKED WHEN IT WAS PLUGGED INTO THE GALLEY CART MODULE. DEACTIVATED FOOD CART CONTROLLER N43, BREAKER PULLED AND WRAPPED WITH DF STICKER. COLLARED BREAKER AND SECURED PIGTAIL END. PARTS: 561-2282 9F21904-503 CABLE.SDR UALA2012061503281Doubler · crackedBS 2521 UPPER LOBE LEFT DOUBLER P/N 65B92966-1 CRACK REPAIRED IAW ECRA 5313-01043. INSPECTION REQUIRED AT 4,000 FLIGHT CYCLE INTERVAL WITH A THRESHOLD OF 14,927 AIRFRAME TOTAL CYCLES. TEXT IS INCOMPLETE, SEE ECRA 5313-01043. REPAIRED IAW ECRA 5313- 01043. SDR UALA2012061503282Doubler · crackedBS 2521 UPPER LOBE RIGHT DOUBLER P/N 65B29266-2 CRACK REPAIRED IAW ECRA 5313-01044. INSPECTION REQUIRED AT 4,000 FLIGHT CYCLE INTERVAL WITH A THRESHOLD OF 14,927 AIRFRAME TOTAL CYCLES. TEXT IS INCOMPLETE, SEE ECRA 5313-01044. REPAIRED IAW ECRA 5313- 01044. SDR UALA2012061503284Structure · misrepairedBS 460-480 BETWEEN S14R & S16R, SHORT EDGE MARGIN, SHORT FASTENER SPACING, FASTENER INTERFERENCE, AND FASTENER LAYOUT IS INCORRECT. REF ECRA 5331-01601. REPAIRED IAW ECRA 5331- 01601. RE-INSPECTION REQUIREMENT INCORPORATED IN TO MAINT PROGRAM AND EQ6982 WILLSDR UALA2012062203321Skin · corrodedSTA 990-1000 S45R-S46R EXT FUSE SKIN DOUBLER CORROSION AT WATER TANK FILL VALVE. MAJOR REPAIR ACCOMPLISHED. REMOVED DAMAGE. MFG NEW DOUBLER PER DRAWING 65B09637-1 AND INSTALLED. NON ROUTINE 0290082.SDR UALA2012061403270Web · crackedWEB CRACKED BS 140-160 BL 0 TO RBL 50 FLOOR TO SKIN SHEAR TIE INSTALLATION 65B01870-231. BS 140-160 BL 0 TO RBL 50 FLOOR TO SKIN SHEAR TIE INSTALLATION CRACK REPAIRED IAW ECRA 5311-01552. INSPECTION REQUIRED AT 3,000 FLIGHT CYCLE INTERVAL WITH A THRESHOLD OFSDR DALA12001946301Panel · separatedDURING WALKAROUND INSPECTION, FOUND PYLON PANEL FROM NUMBER 3 ENG INBEDED INTO NUMBER 4 ENG LEFT FAN COWL. MAINTENANCE REPAIRED DAMAGE PER ERA 504512.SDR UALA2012061503291Fmu · faultyRIGHT ENGINE WILL NOT START. NO FUEL FLOW. RT FUEL VALVE EICAS AND ENGINE VALVE CAUTION LIGHT. REPLACED FMU PER MM. ACCOMPLISHED ENGINE GROUND RUN TEST NR 3 PER MM. ACCOMPLISHED TWO STARTS, ALL OPS & INDICATIONS NORMAL AND NO LEAKS NOTED.SDR UALA2012061403266Light · inoperativeEEL K SEAT LIGHT ROW 25 RIGHT INOP. REPLACED LIGHT ASSY.SDR UALA2012061403267Bottle · dischargedMED 2L - DURING MAINTENANCE ASSIST BOTTLE DISCHARGED, DOOR DID NOT FULLY OPEN AND SLIDE DID NOT DEPLOY. REMOVED 2L DOOR EMERGENCY POWER RESERVOIR. NEW RESERVOIR ON HAND AT DOOR. CONT OF AMIS ITEM 5152009. SUSPECT LOOSE OR BROKEN CONNECTION AT PWR ACTUATOR.SDR UALA2012061403268Light · saturatedEMERGENCY AT LEFT SEAT ROWS 45-53 INOP. FOUND WHOLE AREA AT GALLE Y 4 WET. DRIED AREA. DRIED EEL STRIPS. NOW OPS NORMAL.SDR UALA2012061403269Wire · saturatedEMERGENCY LIGHTS AT AFT GALLEY LEFT SIDE ENTRANCE INOP. FOUND AREA WET ALL AROUND GALLEY 4 WET. DRIED AREA AND DRIED EEL WIRING. NOW OPS NORMAL.SDR UALA2012061503275Light · inoperativeEMERGENCY CEILING LIGHT INOP AT SEATS 25 RIGHT, 32 LEFT AND 16 INOP. REPLACED LAMPS AT LOCATIONS.SDR UALA2012061503276Light · inoperativeEMERGENCY EEL AT DOOR 2 GALLEY LOWER RIGHT WALL INOP. RELAMPED, OPS NORMAL.SDR UALA2012061503290Slide · unserviceableREPLACE DOOR 5L ESCAPE SLIDE. REMOVED SLIDE FOR DOOR 5L PER MM.SDR UALA2012061303257Connector · looseEMERGENCY LIGHT AT SEAT 36L IS INOP. SECURED EMERGENCY CONNECTOR, OPS CHECK GOOD.SDR UALA2012061403271Light · inoperativeEMERGENCY LIGHT AT AFT 4R DOOR SILL IS INOP. RELAMPED, OPS NORMAL.SDR UALA2012061203244Structure · crackedBS 140-160 BL 0 TO RBL 50 FLOOR TO SKIN SHEAR TIE INSTALLATION CRACK REPAIRED. INSPECTION REQUIRED AT 3,000 FLIGHT CYCLE INTERVAL WITH A THRESHOLD OF 25,927 AIRFRAME TOTAL CYCLES. ACCOMPLISH DETAILED VISUAL INSPECTION IAW PART 2 OF ECRA 5311-01552 BEGINNING SDR UALA2012061203245Skin · crackedRIGHT NR 2 MED EXTERNAL SKIN CRACK AT UPPER HINGE CUTOUT. CATEGORY B REPAIR ACP IAW SRM 52-10-01 REPAIR 3. PER SRM TABLE 2, INSPECTION REQUIRED EVERY 3,000 CYCLES. REMOVABLE STRUCTURAL COMPONENT (RSC) MARKED PER 51-00-80. CF STICKER APPLIED. INSPECTIONS TSDR UALA2012061203240Light · failedEMERGENCY LIGHTS DIM FROM ROW 45 UP TO ROW 53 LEFT SIDE AND GALLEY LOWER WALL INOPERATIVE. REMOVED WATER UNDER CARPET AND REPLACED EMERGENCY LIGHT AT LOWER WALL.SDR UALA2012061203241Lamp · inoperativeFLIGHT DECK EMERGENCY LIGHT INOPERATIVE. RELAMPED, OPS CHECKED NORMAL .SDR UALA2012061203242Lens · missingEEL LIGHT AT SEAT 4K MISSING LENS. REPLACED LENS COVER AT 4K. OPS NORMAL.SDR UALA2012061203243Fuse · blownEEL LIGHT INOP RIGHT LOWER TWO WING SLIDE ASSY. REPLACED FUSE IN POWER SUPPLY ABOVE DOOR 3R. LIGHT OPS CHECK NORMAL.SDR UALA2012062203349Shear Tie · crackedBS 140-160 BL 0 TO RBL 50 FLOOR TO SKIN SHEAR TIE INSTALLATION CRACK REPAIRED IAW ECRA 5311-01552. INSPECTION REQUIRED AT 3,000 FLIGHT CYCLE INTERVAL WITH A THRESHOLD OF 25,927 AIRFRAME TOTAL CYCLES. ACCOMPLISH DETAILED VISUAL INSPECTION IAW PART 2 OF ECRA 5SDR UALA2012061103230Structure · damagedLIGHTNING STRIKE DAMAGE AT FASTENER LOCATED AT STRINGER 11R STA 154. REPAIRED PER SRM 51-00-01.SDR UALA2012061103231Structure · damagedLIGHTNING STRIKE DAMAGE LOCATED AT FASTENER STRINGER 11R STA 157. REPAIRED PER SRM 53-00-01.SDR UALA2012061103223Lamp · inoperativeEMERGENCY EXIT LIGHTS INOPERATIVE. RELAMPED, EMERGENCY LIGHTS OPS CHECKED NORMAL.SDR UALA2012061103224Lamp · inoperativeEMERGENCY LIGHT INOPERATIVE IN FLIGHT DECK CEILING. RELAMPED, OPS CHECKED NORMAL.SDR UALA2012061103225Lamp · inoperativeEMERGENCY LIGHT INOPERATIVE SEAT ROW 23 RIGHT. RELAMPED, OPS CHECKED NORMAL.SDR UALA2012061103226Lamp · inoperativeFWD STAIRWELL CEILING EMERGENCY LIGHT INOPERATIVE, RELAMPED, OPS CHECKED NORMAL.SDR UALA2012061103227Power Supply · inoperativeEMERGENCY LIGHTS VERY DIM SEAT ROWS 33 THRU 43 LEFT. REPLACED POWER SUPPLY, OPS CHECKED NORMAL.
Back to Pratt & Whitney PW4056